- All
- Favorite
- Popular
- Most rated
| Brand | Pegasor |
|---|---|
| Origin | Finland |
| Model | Mi2 |
| Instrument Type | Online |
| Detection Principle | Electrostatic Detection with Integrated Heated Sampling |
| Particle Size Range | ~1 nm – 2.5 µm |
| Mass Concentration Range | 1 µg/m³ – 250 mg/m³ (at T = −20°C to +700°C) |
| Number Concentration Range | 10² – 10⁸ particles/cm³ (derived) |
| Sampling Frequency | 100 Hz (24-bit ADC) |
| Response Time | ≤ 0.2 s |
| Heated Sampling Line | 2 m, maintained at 200 °C |
| Operating Ambient Temperature | −20 °C to +55 °C |
| Power Supply | 24 VDC / 16 A (Mi2 unit) |
| Dimensions (L×W×H) | 798 × 484 × 208 mm |
| Weight | ~29 kg |
| Display | 4-inch color touchscreen |
| Outputs | 4-channel 4–20 mA analog |
| Interface | USB for PPS software connectivity |
| Auto-zero function | Yes |
| Compliance | Designed for EN 16454, ISO 8502-12, and EPA Method 202–compatible deployment in regulatory-grade exhaust monitoring |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | AFM1600D |
| Measurement Range | 0–25% O₂ |
| Accuracy | ±0.2% absolute |
| Calibration | ambient air (20.95% O₂) |
| Output | 0–5 V linear analog |
| Power Supply | 11–28 VDC |
| Operating Temperature | −20 to +85 °C |
| Sensor Thread | M18×1.5 |
| Dimensions | 68 mm × 32 mm × 100 mm |
| Weight | 125 g |
| Sensor Type | Bosch LSU 4.2 wideband lambda sensor |
| Cable Length | 3 m |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-204-W |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | 5 °C to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Range Options | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (auto/manual switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Enclosure Dimensions | 310 mm (W) × 250 mm (H) × 285 mm (D) |
| Cable Length | Standard 3 m, up to 300 m optional |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LF-TD 180 |
| Instrument Type | Thermo-Hygrometer |
| Humidity Range | 0–100 % RH |
| Temperature Range | –20 °C to +180 °C |
| Humidity Accuracy | ±2.0 % RH (10–90 % RH) |
| Temperature Accuracy | ±0.3 °C (+10 to +60 °C) |
| Output Signals | Dual 4–20 mA (RH and Temp, separately scaled) |
| Power Supply | 12–29 VDC (nominal 24 VDC) |
| Sensor Head Material | Stainless steel |
| Electronics Housing Material | Anodized aluminum |
| IP Rating | IP65 |
| Probe Dimensions | Ø12 mm × 100 mm |
| Electronics Dimensions | 70 mm (W) × 32 mm (H) × 120 mm (D) |
| Cable Length | 1 m (5-pin sensor connector) |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | NOx/NH3 5241 |
| Detection Principle | Electrochemical Sensing |
| Measurement Range | NOx/NO/NO₂: 0–5000 ppm |
| NH₃ | 0–2000 ppm (λ > 1 only) |
| O₂ | 0–25% vol |
| λ | 0.4–25 |
| AFR | 6–364 |
| φ | 0.04–2.5 |
| Accuracy | NOx/NO/NO₂/NH₃: ±5 ppm (0–1000 ppm), ±1% FS (other) |
| O₂ | ±0.2% abs |
| λ/AFR/φ | ±0.8% at stoichiometric, ±1.8% avg |
| Response Time | <1 s (NOx/NO/NO₂/NH₃), <150 ms (O₂/λ/AFR/φ) |
| Operating Temperature | –40°C to +85°C (electronics), up to 950°C (sensor tip) |
| Power Supply | 11–28 VDC |
| Analog Outputs | Six 0–5 V linearized channels |
| Communication | High-speed CAN (configurable protocol) |
| Sensor Interface | M18×1.5 threaded probe |
| Dimensions (H×W×D) | 64 × 105 × 165 mm |
| Weight | 676 g (main unit), 244 g (sensor module) |
| Cable Length | Standard 4 m, extendable to 100 m |
| Optional Accessories | Pressure compensation kit, mounting bracket, calibration station, NOx/NH₃ sensor simulator, extended cable, AC/DC adapter |
| Brand | Ratfisch |
|---|---|
| Origin | Germany |
| Model | RS200 |
| Instrument Type | Online Analyzer |
| Typical Configuration | TVOC Analyzer |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.01 ppm |
| Accuracy | < ±2% of full scale |
| Response Time (T90) | < 5 s |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | Lambda 5220 |
| Type | Online Analyzer |
| Detection Principle | Electrochemical (Zirconia-based Wideband Sensor) |
| Max. Permissible Error | ±0.5% of reading |
| Zero Drift | ±1% FS/24h |
| Span Drift | ±1% FS/24h |
| Repeatability | ±0.2% FS |
| Measurement Ranges | λ 0.4–25, AFR 6–364, Φ 0.04–2.5, O₂ 0–25% vol, Pressure 0–517 kPa (optional) |
| Accuracy | λ ±0.005 (at λ=1), ±0.008 (λ=0.8–1.2), ±0.009 (elsewhere) |
| Response Time | <150 ms (t₉₀) |
| Operating Temperature | −40 °C to +85 °C |
| Power Supply | 11–28 VDC |
| Analog Outputs | Six isolated 0–5 V linearized channels |
| Communication Interfaces | CAN 2.0B (user-configurable protocol), USB, RS-232 |
| Sensor Interface | M18×1.5 (Lambda probe), 1/4" NPT (pressure transducer) |
| Max. Cable Length | 100 m (sensor to analyzer) |
| Fuel Composition Parameters | Adjustable H:C, O:C, N:C, H₂ ratios |
| Compliance | Designed for R&D and production environments requiring traceable calibration per ISO/IEC 17025 practices |
| Brand | CMC (HimSi) |
|---|---|
| Origin | Germany |
| Model | TMA-404 |
| Type | In-line Dew Point / Moisture Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | 5–50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Range | 0–1 / 10 / 100 / 1000 ppmᵥ (auto/manual range switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Power Supply | 80–230 VAC, 50–60 Hz |
| Enclosure Options | Rack-mount (482 × 133 × 350 mm), Wall-mount (300 × 260 × 280 mm), Bench-top (257 × 160 × 316 mm) |
| Weight | ~6 kg |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMS-SS-P-20-F |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Electrolytic (P2O5) Method |
| Operating Temperature | +5 °C to +50 °C |
| Accuracy | ±1% of reading |
| Sensor Cell Material | Stainless Steel |
| Electrode Material | Platinum |
| Substrate | Glass |
| Sealing Ring Material | Viton |
| Sample Gas Temperature Range | 5–50 °C |
| Flow Rate | 20 NL/h |
| Operating Pressure Range | 0.1–0.5 barg |
| Gas Inlet/Outlet Fitting | 6 mm Swagelok®-compatible stainless steel compression fitting |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | EGR 5230 |
| Instrument Type | Online Analyzer |
| Detection Principle | Electrochemical Sensing |
| Maximum Permissible Error | ±0.5% |
| Repeatability | 0.5% |
| Measurement Range | EGR 0–100% |
| Response Time | <1 s (%EGR) |
| Output | 6-channel linearized 0–5 V analog |
| Power Supply | 11–28 VDC |
| Operating Temperature | −40 °C to +85 °C |
| Sensor Mounting | 18 mm × 1.5 mm threaded O₂ sensors |
| Dimensions | 105 mm (W) × 64 mm (H) × 165 mm (D) |
| Weight | 676 g (main unit), 244 g (sensor module) |
| Cable Length | Standard 4 m, optional up to 100 m |
| Brand | SAXON |
|---|---|
| Origin | Germany |
| Model | DPM1.0 |
| Instrument Type | Aerosol Detector |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | 40 nm – 10 µm |
| Range | 0–300 mg/m³ |
| Resolution | 0.1 mg/m³ |
| Repeatability | ≤ ±3% |
| Accuracy | ≤ ±5% of full scale up to 150 mg/m³ |
| Exhaust Gas Temperature Limit | < 800 °C |
| Probe Melting Point Limit | < 70 °C |
| Sampling Probe | 400 mm flexible stainless-steel probe with 2 m heated sampling line |
| Response Time (T90) | < 15 s (with 2 m heated line) |
| Heating Time | < 10 min |
| Zero Calibration Time | 20 s |
| Built-in Functions | Automatic zero adjustment, internal data logger |
| Communication Interfaces | RS232, USB, Bluetooth |
| Display | Color touchscreen |
| Language Support | English, German |
| Operating Ambient Temperature | 5–40 °C |
| Relative Humidity | ≤ 95% RH (non-condensing) |
| Power Supply | 230 VAC / 50 Hz, max. 250 VA (including probe) |
| Dimensions (W×H×D) | ~190 × 275 × 330 mm |
| Weight | ~7.5 kg |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-202-19"-Ex |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -10 °C to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Range Options | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (auto/manual switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–50 °C |
| Environmental Operating Range | 5–65 °C |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Intrinsic Safety | Integrated Zener barrier |
| Enclosure | 19" rack-mount (482 mm W × 133 mm H × 350 mm D) |
| Cable Length | Standard 3 m, optional up to 300 m |
| Brand | CMC (HimSi) |
|---|---|
| Origin | Germany |
| Model | TMA-202-W |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -10 °C to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Range Options | 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–2,500 ppm (auto/manual switching) |
| Sensitivity | 0.1% of full scale |
| Analog Output | 4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–50 °C |
| T₅₀ Response Time | <8 s |
| Ambient Temperature Range | 5–65 °C |
| Cable Length | Standard 3 m (up to 300 m optional) |
| Dimensions | 300 mm (W) × 260 mm (H) × 280 mm (D) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASI-150 |
| Pricing | Available Upon Request |
| Measurement Principle | Lead Acetate Tape Detection |
| Range | 0–1 ppm / 0–50 ppm / 0–500 ppm |
| Resolution | 1 ppb |
| Accuracy | ±2% of reading |
| Repeatability | ±1% of reading |
| Linearity | ±1% of full scale |
| Zero Drift | <0.01 ppm/24h |
| Temperature Coefficient | 0.01%/°C |
| Response Time (T90) | 0.75 s |
| Weight | 4.5 kg |
| Dimensions | 25.4 × 30.5 × 15.2 cm |
| Power Supply | 220 VAC, 50 Hz or 12/24 VDC |
| Operating Temperature | 5–50 °C |
| Storage Temperature | 0–70 °C |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | LambdaCAN |
| Input Channels | Up to 8 lambda sensors + up to 8 optional pressure sensors |
| Lambda Range | 0.40–25 |
| AFR Range | 6.0–364 |
| O₂ Range | 0–25% |
| Pressure Range (optional) | 0–517 kPa |
| Lambda Accuracy | ±0.005 at λ=1, ±0.008 at λ=0.8–1.2, ±0.009 elsewhere |
| AFR Accuracy | ±0.1 at 14.6, ±0.2 at 12–18, ±0.5 elsewhere |
| O₂ Accuracy | ±0.2 (0–2% O₂), ±0.4 (other) |
| Pressure Accuracy | ±5.2 kPa |
| Response Time | <150 ms |
| Fuel Composition Parameters | Configurable H:C, O:C, N:C, and H₂ ratios |
| CAN Interface | High-speed CAN per ISO 11898 |
| Operating Temperature | −40 °C to +105 °C |
| Power Supply | 11–28 VDC |
| Sensor Thread | 18 mm × 1.5 mm (lambda), 1/4" NPT (pressure) |
| Module Dimensions | 145 mm × 120 mm × 40 mm |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-204-W |
| Instrument Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | −10 °C to +50 °C |
| Accuracy | ±1% of Full Scale |
| Repeatability | ±0.1% of Full Scale |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–2,500 ppm (Auto-ranging or Manual Selection) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–50 °C |
| Display | Touchscreen with Multilingual Interface (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 Relay Outputs |
| Enclosure Dimensions | 300 mm (W) × 260 mm (H) × 280 mm (D) |
| Standard Cable Length | 3 m (up to 300 m optional) |
| Brand | Ratfisch |
|---|---|
| Origin | Germany |
| Model | RS55-T |
| Measurement Principle | Catalytic Combustion (Flame Ionization Detection alternative configuration available per customization) |
| Range | 0–10 / 100 / 1,000 / 10,000 / 100,000 ppm C₃H₈ (propane-equivalent) |
| Linearity | ±2% of full scale up to 10,000 ppm |
| Cross-sensitivity to O₂ | <±2% of full scale |
| Detection Limit | <2% of lowest full-scale range |
| Zero Drift | <2% FS/week |
| Span Drift | <4% FS/week |
| Response Time (T₉₀) | ~1–2 s (sample line excluded) |
| Sample Flow Rate | ~220 L/h |
| Operating Temperature | +5 °C to +35 °C |
| Power Supply | 230 V / 50 Hz, 800 W |
| Dimensions | 483 mm (W) × 267 mm (H) × 500 mm (D) |
| Weight | ~26.5 kg |
| Certified Compliance | TÜV-certified per German 17. BImSchV |
| EPA Method Compatibility | Compliant with EPA Method 25A and 25B requirements for THC monitoring |
| Output Signals | 0–10 V analog, 0/4–20 mA isolated current loop |
| Status Contacts | Pre-alarm, Alarm, Range Identification, Flame-Out Indication, Calibration Mode (Zero/Gas), System Health (Pressure/Temperature/Flame Monitoring) |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | NOxCAN |
| Sensor Type | NTK Ceramic NOx Sensor (1), Optional Pressure Sensor (1) |
| Measurement Range | NOx: 0–5000 ppm (λ ≥ 1) |
| Lambda | 0.40–25 |
| AFR | 6.0–364 |
| O₂ | 0–25% vol |
| Pressure | 0–517 kPa (0–75 psia) |
| Accuracy | NOx: ±30 ppm (0–1000 ppm), ±3% FS (other) |
| Lambda | ±0.008 (λ = 1), ±0.016 (λ = 0.8–1.2), ±0.018 (other) |
| AFR | ±0.15 (14.6), ±0.4 (12–18), ±1.0 (other) |
| O₂ | ±0.4% (0–2% O₂), ±0.8% (other) |
| Pressure | ±5.2 kPa (±0.75 psia) |
| Response Time | <700 ms (NOx), <150 ms (Lambda/AFR/O₂) |
| Fuel Composition Parameters | Configurable H:C, O:C, N:C, and H₂ ratios |
| CAN Interface | High-Speed CAN per ISO 11898, User-Assignable Node ID, Multi-Module Bus Support |
| Operating Temperature | −55 °C to +125 °C |
| Dimensions | 145 mm × 120 mm × 40 mm |
| Power Supply | 11–28 VDC |
| Sensor Mounting | 18 mm × 1.5 mm thread (NOx), 1/4" NPT (pressure) |
| Cable Length | Standard 1 m (2 m optional) |
| Calibration | Onboard EEPROM in sensor connector for zero/span calibration data storage |
| Software | PC-based configuration, real-time control, calibration, and parameter monitoring (CAN adapter required, sold separately) |
| Optional Accessories | Analog-output display head (supports up to two NOxCAN modules) |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | Lambda PRO |
| Instrument Type | Portable |
| Detection Principle | Electrochemical Sensor (NTK Wideband) |
| Measurement Range | AFR 8.0–25.5 |
| Accuracy | ±1% of stoichiometric value, ±2% for non-stoichiometric conditions |
| Response Time | <150 ms |
| Calculation Interval | 2 ms |
| Fuel Compatibility | Gasoline, Methanol, and other combustible fuels (with appropriate sensor calibration) |
| Analog Output | Linearized 0–5 V DC, BNC female connector |
| SEGO Sensor Interface | Supported |
| Data Logging | Min/Max AFR and λ values |
| Power Supply | 11–28 VDC |
| Dimensions | 190.5 × 101.6 × 30.5 mm (W × H × D) |
| Weight | 340 g |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MCA03 |
| Price Range | USD 42,000–70,000 |
| Instrument Type | Extractive In-Situ Flue Gas Analyzer |
| Measurement Accuracy | ≤ ±2% of Full Scale |
| Repeatability | Not Specified |
| Response Time | ≤10 s |
| Stability | Not Specified |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | 5240 |
| Measurement Range | NOx 0–5000 ppm, NH₃ 0–1000 ppm, O₂ 0–25% vol, λ 0.4–25, AFR 6–364, φ 0.04–2.5 |
| Accuracy | NOx ±5 ppm (0–1000 ppm), ±1% FS (other) |
| Response Time | <1 s (NOx/NH₃), <150 ms (O₂/λ/AFR/φ) |
| Output | 6 × 0–5 V analog, CAN 2.0B, USB 2.0 |
| Power | 11–28 VDC |
| Sensor Thread | M20×1.5 or M18×1.5 |
| Dimensions (H×W×D) | 64 × 105 × 165 mm |
| Weight | 676 g (main unit), 244 g (sensor module) |
| Operating Temp. | −40 to +85 °C (electronics), up to 950 °C (sensor tip) |
| Optional | Pressure compensation kit, extended cable (up to 100 m), AC/DC adapter |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-204-W-Ex |
| Product Type | In-line Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | 5–50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Range Options | 0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–2500 ppm (auto/manual switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Enclosure Rating | ATEX/IECEx certified for Zone 1/21 (Ex d ia IIC T4 Ga / Ex tD A21 IP66 T80°C) |
| Dimensions | 310 × 250 × 285 mm (W × H × D) |
| Cable Length | Standard 3 m (up to 300 m optional) |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | NOxCANt |
| Communication | High-Speed CAN (ISO 11898) |
| Input | 1× NTK T-type ceramic NOx sensor (18 mm × 1.5 mm thread) + optional pressure sensor (1/4" NPT) |
| Measurement Range | NOx: 0–5000 ppm (λ ≥ 1 and λ < 1) |
| Lambda | 0.40–25 |
| AFR | 6.0–364 |
| O₂ | 0–25% vol |
| Pressure | 0–517 kPa (0–75 psia) |
| Accuracy | NOx: ±20 ppm (0–1000 ppm), ±2% FS (remaining range) |
| Lambda | ±0.008 @ λ=1, ±0.016 @ λ=0.8–1.2, ±0.018 (elsewhere) |
| AFR | ±0.15 @ 14.6, ±0.4 @ 12–18, ±1.0 (elsewhere) |
| O₂ | ±0.4% (0–2% O₂), ±0.8% (elsewhere) |
| Pressure | ±5.2 kPa (±0.75 psia) |
| Response Time | <1 s (NOx), <150 ms (Lambda/AFR/O₂) |
| Fuel Composition Configurability | H:C, O:C, N:C, H₂ ratios user-definable |
| Operating Temperature | −55 °C to +125 °C |
| Dimensions | 145 mm × 120 mm × 40 mm |
| Power Supply | 11–28 VDC |
| Sensor Cable | Standard 1 m (2 m optional) |
| Brand | CMC (HimSi) |
|---|---|
| Origin | Germany |
| Model | TMA-210-P |
| Instrument Principle | Electrolytic (P₂O₅ sensor) |
| Operating Temperature Range | +5 °C to +150 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–2,500 ppm (auto/manual range switching) |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Alarm Outputs | Configurable high/low limit relays |
| Analog Output | 4–20 mA (user-configurable) |
| Power Supply | Internal rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Power Consumption | 8 W |
| Environmental Operating Temp. | −10 °C to +50 °C |
| Enclosure Rating | IP20 |
| Dimensions | 363 mm (W) × 115 mm (H) × 377 mm (D) |
| Weight | ~6 kg |
Show next