Empowering Scientific Discovery

Beijing Shijia Wanlian Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
Brand--
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelUltrasonic Valve Leak Detection System
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYasuda
OriginJapan
ModelNo.145-D
Standard ComplianceJIS Z 0237
Specimen Dimensions25 mm × 150 mm (or 12 ± 0.5 mm × 150 mm)
Test PlateSUS304, 50 mm × 125 mm × ≥1.1 mm
Load Range200 gf to 1,000 gf (±5 g tolerance)
Fixture TypeUpper hook-type, Lower flat chuck (30 mm width)
Vertical TravelMax. 45 mm, motorized auto-stop actuation
Temperature CapabilityUp to 150 °C
Timer FunctionsPreheating time setting, fall-time measurement, programmable test duration
Optional AccessoriesLow-temperature chamber, constant temperature/humidity chamber, in-chamber lighting, 90° peel test kit
Power Supply & DimensionsConfiguration-dependent
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYasuda
OriginJapan
ModelNo.305-YPL
Applicable StandardsJIS K6404-11, P8112, P8131, TAPPI T403, T807, T810, ISO 2758, ISO 2759
Pressure RangeLow-pressure configuration (typically up to 1.6 MPa / 232 psi)
Test PrincipleHydraulic diaphragm burst method with clamped specimen
DisplayDigital readout
ComplianceDesigned for GLP-compliant lab environments with manual data recording capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYasuda
OriginJapan
ModelNo.189-PN
Compliance StandardsJIS K7144, ISO 2818
Blade TypeInterchangeable Single-Edge Cutting Tool
ApplicationCharpy/Izod Impact Test Specimen Notching
MountingBenchtop, Fixed-Base Design
Drive MechanismManual Feed with Precision Depth Stop
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYasuda
OriginJapan
ModelNo.185
Max. Load50 N (dead-weight type)
Temperature RangeUp to 200 °C
Parallel Plate Diameterφ40 mm (optional: UL-compliant φ3/4″ or φ3/8″)
Thickness Displacement MeasurementAnalog dial indicator (0.01 mm resolution, 10 mm max travel)
Specimen Support Configurations1-, 3-, or 5-station modular frame
Included AccessoryRadius R5 mm metal mandrel
Power SupplyAC 200 V, single-phase, 15–30 A, 50/60 Hz
Dimensions & Weight1-station: ~780 × 825 × 1800 mm (W×D×H), ~142 kg
3-station~1250 × 1120 × 1800 mm, ~286 kg (benchtop height option: H = 952 mm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYasuda
OriginJapan
ModelNo.473
Test StandardsJIS L 1058, ASTM D3939
Test MethodICI Mace (Rotating Drum with Protruding Pins)
Rotation Cycles100 ± 1 rev
Sample MountingCylindrical Mandrel Wrapped with Fabric Specimen
EvaluationVisual Comparison Against Standard Photographic Rating Scale (Grade 1–5)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYasuda
OriginJapan
ModelNo.105
Compliance StandardsJIS K 6249, ASTM D 926, ISO 7323
Measurement PrincipleParallel-plate compression under standardized load and dwell time
Output UnitPlastometric value (dimensionless, ×100 amplification of thickness reduction)
Load ApplicationFixed dead-weight loading system
Test DurationStandardized dwell time per method (e.g., 15 s per JIS K 6249)
Plate GeometryPrecision-ground parallel stainless steel plates
Sample Thickness RangeCompatible with 10 mm × 10 mm × ~2 mm vulcanized rubber specimens
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYasuda
OriginJapan
ModelNo.170-AUTO
Temperature Range−60 °C to 100 °C (dry ice cooling)
Heating Rate2 °C/min
Specimen DimensionsW 6.35 ± 0.03 mm × L 64 mm × T 0.8–1.5 mm
Gauge Length40 mm
Angular Range0–270° (1° resolution)
Torque ApplicationPulley-type weight system (5 g, 10 g, 20 g, 50 g)
Encoder TypeRotary encoder for torsional angle measurement
Power Supply220 V, single-phase, 10 A, 50/60 Hz
Host Dimensions/Weight~300 × 400 × 780 mm / ~40 kg
Control Box Dimensions/Weight~330 × 350 × 180 mm / ~10 kg
Standards ComplianceJIS K6734, K6745, K6773, K6924-2, ASTM D1043, ISO 458
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYasuda
OriginJapan
ModelNo.409
Complies withJIS L 1092 (Method A – Low-Pressure Rise), ISO 811
Test PrincipleHydrostatic Pressure Resistance Measurement via Controlled Water Column Rise
Operation ModesDynamic Water Level Rise (Standard A Method), Fixed-Pressure Hold, and Leakage Detection Mode
Sample ClampingDual-Ring Mechanical Clamp with Uniform Sealing Force
Maximum Test Height≥ 200 cm H₂O (typical range for textile hydrostatic head evaluation)
Resolution1 mm water column
Repeatability≤ ±2 cm H₂O (per ASTM D751 / ISO 811 inter-laboratory consensus)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYasuda
OriginJapan
ModelNo.105-AUTO
Standards ComplianceJIS K 6249, ASTM D 926, ISO 7323
Sample GeometryCylindrical specimen (Φ16 mm × 10 mm height, volume 2.00 ± 0.02 cm³)
Platen DimensionsUpper and lower plates Φ148 mm × 12 mm thick
Applied Load Range24.5 N (2.5 kgf) to 49.0 ± 0.05 N (5.0 kgf)
Dial Indicator Resolution0.01 mm
Maximum Travel20 mm
Data OutputReal-time thickness-vs.-time curve on PC display
Software PlatformDedicated Windows XP-compatible application
Power Supply220 V AC, single-phase, 3 A, 50/60 Hz
Dimensions (W×D×H)≈365 × 250 × 500 mm
Weight≈15 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYasuda
OriginJapan
ModelDHS (Laboratory Version)
ApplicationOffline Lab Use
Test MethodsASTM D1238, ISO 1133, GB/T 3682, GB/T 9643, JIS K7210
Automation LevelFully Automated Sample Loading, Weight Switching, Melt Extrusion, Gravimetric MFR Calculation, and Self-Cleaning Cycle
ComplianceGLP-ready architecture with audit-trail-capable software logging
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0