Beijing Taikun Industrial Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTaiKun
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelTK-GEM50P4-83-RB-SMP
Instrument TypeLaboratory Gamma Spectrometer
Detector TypeP-type Coaxial High-Purity Germanium (HPGe)
Measurement ModeGamma-ray Spectrometry
Sample FormSolid
Energy Range30 keV – 10 MeV
Relative Efficiency≥50% @ 1.33 MeV
Energy Resolution (FWHM)≤0.85 keV @ 122 keV, ≤1.8 keV @ 1.33 MeV
Peak-to-Compton Ratio≥53
Peak Shape (FW.02M/FWHM)≤3.0
Cooling MethodElectromechanical Cryocooler (Pulse Tube) with 25 L LN₂ Dewar
ShieldingDual-layer low-background lead chamber (15 cm Pb + Cu/Sn lining)
Software ComplianceSupports FDA 21 CFR Part 11 audit trails, GLP/GMP data integrity protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGEORADIS
OriginCzech Republic
ModelRT-50 A
Instrument TypeLaboratory Gamma Spectrometer
Detector TypeNaI(Tl) Scintillation Crystal (76 mm × 76 mm, 0.35 L)
Measurement Range20 keV – 3.0 MeV
Energy Resolution≤7.5% FWHM at 662 keV (¹³⁷Cs)
Sensitivity0.02 Bq/g (for ⁶⁰Co)
Channel Count1024-channel MCA
Shielding≥9 cm lead equivalent (min. wall thickness 3.5 in), integrated sliding heavy-duty shielded lid
Dimensions (H×W×D)770 × 360 × 620 mm
Weight410 kg (lead-shielded configuration: 580 kg)
InterfaceUSB 2.0
Operating Temperature0–40 °C
Software PlatformLabCentre (Windows/Linux, FirebirdSQL 2.6+)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTaiKun
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTK-Mobius
Instrument CategoryGamma-Ray Spectrometer
Instrument TypeLaboratory-Based
Sample FormSolid
Detector TypeHigh-Purity Germanium (HPGe)
Cooling MethodLiquid Nitrogen Recondensation (Closed-Cycle)
Operating Temperature≤ 77 K
Nominal Dewar Capacity28 L
Continuous Operation (Uninterrupted Power)Up to 2 Years
Power Consumption125 W (Typical), 300 W (Max)
Ambient Operating Conditions0–40 °C, 20–90% RH (Non-Condensing)
Acoustic Noise Level< 60 dB(A) at 1 m
Displayed ParametersCryocooler Status, Estimated Remaining Cryogenic Hold Time (h), LN₂ Level, Low-Level Warning Threshold (48 h)
Physical Dimensions (Dewar Only)66.5 cm H × 44.1 cm Ø
Air Filter Maintenance IntervalMonthly
Mounting FlexibilityVertical or Horizontal Cold Finger Orientation
Electronics ArchitectureDecoupled Cryo-Control and Signal Processing Circuitry (Separated from Dewar)