Empowering Scientific Discovery

Beijing Times Newway Measurement & Control Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimePower
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelTP791
PricingAvailable Upon Request
Measurement PrincipleLight Obscuration (LO) per ISO 11171 & ISO 4406
Detection Range0.8 µm to 600 µm (sensor-dependent)
Accuracy±0.5%
Repeatability (RSD)<2%
Resolution<10%
Operating Temperature0–60 °C
Light SourceSemiconductor Laser
Number of Measurement Channels16 (user-configurable size thresholds within calibrated range)
Sample Flow Rate5–80 mL/min
Coincidence Limit12,000–24,000 particles/mL (sensor-dependent)
Power SupplyAC 220 V ±10%, 50 Hz ±10%
Power Consumption≤200 W
Dimensions (Main Unit)360 × 370 × 700 mm
Dimensions (Air Pump)330 × 266 × 255 mm
Weight (Main Unit)30 kg
Weight (Air Pump)10 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimePower
ModelTP150
OriginBeijing, China
ManufacturerTimePower Co., Ltd.
Measurement Range0.00–20.00 mg/L
Resolution0.01 mg/L (in mg/L range) / 0.1 µg/L (in µg/L range)
Repeatability≤1% FS
Stability±1.5% FS
Temperature Compensation Range0.1–80.0 °C
Water Sample Temperature Range5–80 °C
Ambient Temperature Range5–45 °C
Humidity Limit≤90% RH (non-condensing)
Output Signals0–10 mA / 0–20 mA / 4–20 mA (selectable)
Relay Outputs2 SPST, AC220V/3A or DC30V/3A
Communication InterfaceRS485
Display128×64 dot-matrix LCD with Chinese interface
Power SupplyAC 220 V ±10%, 50 Hz ±1 Hz
Power Consumption<5 W
Enclosure RatingIP65
Dimensions142 × 125 × 155 mm (H×W×D)
Panel Cutout138 × 138 mm
Weight1.6 kg
Data Retention>10 years after power loss
Response Time (T90)<5 min at 25 °C
Sensor TypePolarographic (Clark-type) with BJC membrane cap rated to 130 °C
Temperature SensorPt1000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimepower
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelTP651
PricingAvailable Upon Request
Temperature RangeAmbient to 100 °C
Temperature Accuracy±2 °C
Temperature Repeatability≤4 °C
Temperature Resolution0.1 °C
Bath Temperature Setpoints54 °C ±1 °C (standard), 82 °C ±1 °C (for viscous oils)
Stirring Duration5 min (automated)
Stirrer PositioningDescends to 6 mm above cylinder bottom
Cylinder100 mL calibrated glass cylinder
Power SupplyAC 220 V ±10%, 50 Hz ±10%
Power Consumption≤1600 W
Dimensions (W×D×H)510 mm × 360 mm × 580 mm
Net Weight23.5 kg
Operating Environment5–40 °C, ≤85% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimePower
ModelTP 340
OriginBeijing, China
ManufacturerTimePower Instrument Co., Ltd.
TypeNon-contact Inductive Conductivity-Based Concentration Analyzer
Measurement RangeHCl (0–10.00%), NaOH (0–10.00%), H₂SO₄ (0–20.00%), NaCl (0–20.00%), HNO₃ (0–15.00%), Na₂CO₃ (0–10.00%)
Accuracy±2% F.S.
Resolution0.01%
Repeatability≤1%
Stability±1% F.S./4 h
Temperature CompensationPt1000 sensor, 0–60 °C
Sample Temp.5–50 °C
Ambient Temp.5–45 °C
Humidity≤90% RH (non-condensing)
Power SupplyAC 85–265 V, 45–65 Hz
Power Consumption≤5 W
Dimensions200 × 200 × 85 mm
Weight2.1 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimePower
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product TypeBenchtop Laboratory Analyzer
ModelTP306
Measurement PrincipleMolybdenum Blue Colorimetric Method (Silicomolybdic Acid Reduction)
Display5.0-inch TFT color touchscreen with Chinese UI
Optical SourceImported monochromatic cold-light LED (peak λ = 650 nm ± 5 nm)
Detection Range0–200 µg/L SiO₂ (extendable to 1000 µg/L via dilution)
Resolution0.1 µg/L
Accuracy±2% FS or ±1 µg/L (whichever is greater)
Repeatability≤1.5% RSD
Blank CalibrationAutomatic zero-point and electronic drift compensation
Data StorageCyclic memory for up to 256 test records
Power SupplyAC 220 V ± 10%, 50/60 Hz
Dimensions320 × 240 × 180 mm
Weight4.2 kg
ComplianceDesigned per GB/T 12149–2019 (Chinese Standard for Silica Determination in Boiler Water and Feedwater), ASTM D859–22 (Standard Test Method for Silica in Water), and ISO 10523:2022 (Water Quality — Determination of pH)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimePower
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelTP737
PricingUpon Request
Measurement Range0.0 °C to 1372 °C
Temperature Resolution0.1 °C (0.0–999.9 °C), 1 °C (>999.9 °C)
Temperature Accuracy±0.2% of reading
Ambient Operating Temperature≤30 °C
Relative Humidity10–70% RH
Storage/Transport Temperature−25 °C to +55 °C
Power SupplyAC 220 V ±10%, 50 Hz ±10%
Max. Power Consumption≤2 kW
Dimensions (H×W×D)500 mm × 400 mm × 360 mm (main unit)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimepower
ModelTP107
TypeOnline Analyzer
OriginBeijing, China
ManufacturerTimepower (Producer)
Measurement PrincipleVanadomolybdophosphoric Yellow Colorimetry (Acidic Medium)
Display7.0-inch Color TFT Touchscreen (Chinese UI)
Range Options0.00–20.00 mg/L or 0.00–50.00 mg/L
Accuracy±2% F.S.
Repeatability≤±1% F.S.
Drift≤±1% F.S./24 h
Response Time< 4 min
Cycle Time~3 min per channel
Sample Flow Rate10–40 L/h
Sample Temp.5–50 °C
Suspended Solids< 5 µm, non-colloidal
Ambient Temp.5–45 °C
Ambient Humidity≤90% RH (non-condensing)
Reagent Consumption~3 L/month
Output SignalsIsolated 0–20 mA / 4–20 mA / 0–10 mA (programmable)
Alarm OutputsIndependent per channel (flow loss, high/low limit)
Power SupplyAC 85–265 V, 45–65 Hz
Power Consumption≤100 W
Dimensions (W×H×D)460 × 720 × 280 mm
Panel Cutout670 × 410 mm
Weight22 kg
ComplianceGB/T 6913–2008
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimePower
ModelTP304
OriginBeijing, China
ManufacturerTimePower (Domestic Producer)
Measurement PrinciplePhotometric Colorimetry (Based on Lambert-Beer Law)
Display5.0-inch TFT color touchscreen (Chinese UI)
Range0.0–200 μg/L
Accuracy±3% F.S.
Resolution0.1 μg/L
Repeatability≤1%
Stability±1.5% F.S. / 4 h
Operating Temp.5–45 °C
Humidity≤90% RH (non-condensing)
Power SupplyAC 85–265 V, 45–65 Hz
Power Consumption≤30 W
Dimensions260 × 200 × 180 mm
Weight3.2 kg
Data Storage256 entries (circular buffer)
Light SourceImported monochromatic cold LED
CalibrationAutomatic zero calibration (blank), periodic curve calibration recommended
Compliance ContextDesigned for routine QC in power plant water chemistry per ASTM D1066, ISO 5667-3, and DL/T 938 (Chinese thermal power industry standard)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimepower
OriginBeijing, China
Manufacturer TypeManufacturer
Origin CategoryDomestic (China)
ModelTP310
Instrument TypeLaboratory Water Quality Analyzer
Measured ParameterpH
Measurement Range0.00–14.00 pH
Accuracy±0.02 pH
Resolution0.01 pH
Input Impedance≥1×10¹² Ω
Repeatability≤1%
Stability±1% F.S./4 h
Response Time (T90)<1 min at 25 °C
Temperature Compensation Range0–60 °C
Temperature SensorPt1000
Sample Temperature Range5–60 °C
Ambient Temperature5–45 °C
Ambient Humidity≤90% RH (non-condensing)
Storage/Transport Temperature−25–55 °C (electrode excluded
Power SupplyAC 85–265 V, 45–65 Hz
Power Consumption≤5 W
Dimensions200 × 200 × 85 mm
Weight2.1 kg
Display5.0-inch capacitive color touchscreen, Chinese UI
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimepower
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrinciplePotassium Permanganate Oxidation with ORP Endpoint Detection
Range0.1–10 mg/L (multi-segment calibration)
Repeatability≤5% RSD
Accuracy±5% of reading
LOD0.4 mg/L
Resolution0.01 mg/L
Single-Test Duration13 min (water bath heating)
DisplayBacklit LCD with keypad interface
Data Storage30,000 measurement records with power-loss protection
Calibration Curves1 built-in standard curve + 96 user-defined curves
ConnectivityEthernet port + USB 2.0
OutputIntegrated thermal printer
Light SourceImported long-life cold LED (rated lifetime: 100,000 h)
Operating ModesStandard mode / Continuous measurement mode
Reagent CompatibilityDedicated pre-packaged CODMn test kits (ISO/GB-compliant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimepower
OriginBeijing, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelTP582
PricingUpon Request
Temperature Control RangeAmbient to 150 °C
Temperature Accuracy±1 °C
Heating Power600 W (main) + 1000 W (auxiliary)
Temperature SensorIndustrial Pt100 Platinum Resistance Thermometer
Timing Range1 min to 24 h
Time DisplayLED digital
Temperature Display7-segment LED
Sample CapacityUp to 12 copper strips (4 test wells per bath, configurable multi-bath operation)
Ambient Operating Conditions5–40 °C, ≤85% RH
Power SupplyAC 220 V ±10%, 50 Hz ±10%
Power Consumption≤1800 W
Dimensions (W×D×H)480 × 360 × 520 mm
Weight18 kg
Compliance StandardsGB/T 5096, GB/T 7326, ASTM D130, ASTM D4048, SH/T 0232, SH/T 0023, ISO 6251
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimePower
ModelTP683
Measurement PrincipleOxygen Bomb Combustion with Mercury Nitrate or Barium Chloride Titration
ComplianceDL/T 433, GB/T 388
Max Operating Pressure≥20 MPa
Ignition Voltage12–24 V DC
Repeatability (RSD)≤0.0006% (w/w)
Ambient Temperature Range10–40 °C
Relative Humidity30–80% RH
Power SupplyAC 220 V ±10%, 50 Hz ±10%
Power Consumption<500 W
Dimensions (W×D×H)300 × 300 × 390 mm
Cooling MethodIntegrated High-Flow Air Cooling
Net Weight8.7 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimepower
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelTP304
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimePower
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelTP160
Instrument TypeIndustrial Online ORP Meter
Display128×64 Dot-Matrix LCD (Chinese Interface)
Measurement Range±2000 mV
Electrical Accuracy±1 mV
Resolution0.1 mV
Temperature Compensation Range0–60 °C
Sample Temperature Range5–60 °C
Sample Pressure Limit< 0.6 MPa
Environmental Operating Temperature5–45 °C
Relative Humidity≤90% RH (non-condensing)
Storage/Transport Temperature−25–55 °C
Power SupplyAC 85–265 V, 45–65 Hz
Power Consumption≤15 W
Output SignalsIsolated Current Output (0–10 mA / 0–20 mA / 4–20 mA), Load < 300 Ω
Relay Outputs2 SPST (AC 220 V / 3 A or DC 30 V / 3 A), Configurable Alarm Thresholds
Enclosure RatingIP65
Data LoggingCyclic Storage with Auto-Overflow Management
Memory Retention After Power Loss>10 Years
Dimensions (H×W×D)145 mm × 120 mm × 150 mm
Panel Cutout138 mm × 138 mm
Weight0.64 kg
Electrode TypePt-based Redox Electrode (Direct Potentiometric Measurement)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimepower
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelTP 691
PricingUpon Request
Measurement PrincipleMicroscopic Filtration & Manual Particle Counting
Detection Threshold≥5 µm (maximum dimension)
Microscope Magnification100× with Integrated Illumination
Contamination Rating RangeNAS 1638 Classes 4–12
Dimensions410 mm × 310 mm × 230 mm
Weight6.4 kg
Compliance StandardsDL/T 432, GB/T 20082, ISO 4406, NAS 1638, GB/T 18854, ISO 11171, GJB 420B, GJB 380.4A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimePower
OriginBeijing, China
ManufacturerTimePower Measurement & Control Co., Ltd.
ModelTP140
Output Signals0–10 mA / 0–20 mA / 4–20 mA (selectable)
Alarm Relays2 SPST (AC 220 V / DC 30 V, 3 A)
Display128 × 64 dot-matrix LCD with Chinese interface
Measurement RangeHCl (0–10.00%), NaOH (0–10.00%), H₂SO₄ (0–20.00%), NaCl (0–20.00%), HNO₃ (0–15.00%), Na₂CO₃ (0–10.00%)
Accuracy±2% FS
Resolution0.01%
Repeatability<1% FS
Temperature CompensationPt1000 sensor, 0–60 °C
Sample Temp. Range5–50 °C
Ambient Temp. Range5–45 °C
Humidity≤90% RH (non-condensing)
Storage Temp.−25–55 °C (electrode excluded
Power SupplyAC 85–265 V, 45–65 Hz
Power Consumption≤15 W
Enclosure RatingIP65
Dimensions (W×H×D)145 × 120 × 150 mm
Panel Cutout138 × 138 mm
Weight0.64 kg
MountingPanel-mount / wall-mount / rack-mount
Electrode OptionsFlow-through / immersion / flanged (custom configurations available upon consultation)
Data LoggingCyclic memory with auto-overflow overwrite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimepower
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelTP304
PricingUpon Request
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0