Add to compare
BrandTimePower
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product TypeBenchtop Laboratory Analyzer
ModelTP306
Measurement PrincipleMolybdenum Blue Colorimetric Method (Silicomolybdic Acid Reduction)
Display5.0-inch TFT color touchscreen with Chinese UI
Optical SourceImported monochromatic cold-light LED (peak λ = 650 nm ± 5 nm)
Detection Range0–200 µg/L SiO₂ (extendable to 1000 µg/L via dilution)
Resolution0.1 µg/L
Accuracy±2% FS or ±1 µg/L (whichever is greater)
Repeatability≤1.5% RSD
Blank CalibrationAutomatic zero-point and electronic drift compensation
Data StorageCyclic memory for up to 256 test records
Power SupplyAC 220 V ± 10%, 50/60 Hz
Dimensions320 × 240 × 180 mm
Weight4.2 kg
ComplianceDesigned per GB/T 12149–2019 (Chinese Standard for Silica Determination in Boiler Water and Feedwater), ASTM D859–22 (Standard Test Method for Silica in Water), and ISO 10523:2022 (Water Quality — Determination of pH)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimepower
ModelTP107
TypeOnline Analyzer
OriginBeijing, China
ManufacturerTimepower (Producer)
Measurement PrincipleVanadomolybdophosphoric Yellow Colorimetry (Acidic Medium)
Display7.0-inch Color TFT Touchscreen (Chinese UI)
Range Options0.00–20.00 mg/L or 0.00–50.00 mg/L
Accuracy±2% F.S.
Repeatability≤±1% F.S.
Drift≤±1% F.S./24 h
Response Time< 4 min
Cycle Time~3 min per channel
Sample Flow Rate10–40 L/h
Sample Temp.5–50 °C
Suspended Solids< 5 µm, non-colloidal
Ambient Temp.5–45 °C
Ambient Humidity≤90% RH (non-condensing)
Reagent Consumption~3 L/month
Output SignalsIsolated 0–20 mA / 4–20 mA / 0–10 mA (programmable)
Alarm OutputsIndependent per channel (flow loss, high/low limit)
Power SupplyAC 85–265 V, 45–65 Hz
Power Consumption≤100 W
Dimensions (W×H×D)460 × 720 × 280 mm
Panel Cutout670 × 410 mm
Weight22 kg
ComplianceGB/T 6913–2008
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimepower
OriginBeijing, China
Manufacturer TypeManufacturer
Origin CategoryDomestic (China)
ModelTP310
Instrument TypeLaboratory Water Quality Analyzer
Measured ParameterpH
Measurement Range0.00–14.00 pH
Accuracy±0.02 pH
Resolution0.01 pH
Input Impedance≥1×10¹² Ω
Repeatability≤1%
Stability±1% F.S./4 h
Response Time (T90)<1 min at 25 °C
Temperature Compensation Range0–60 °C
Temperature SensorPt1000
Sample Temperature Range5–60 °C
Ambient Temperature5–45 °C
Ambient Humidity≤90% RH (non-condensing)
Storage/Transport Temperature−25–55 °C (electrode excluded
Power SupplyAC 85–265 V, 45–65 Hz
Power Consumption≤5 W
Dimensions200 × 200 × 85 mm
Weight2.1 kg
Display5.0-inch capacitive color touchscreen, Chinese UI
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTimepower
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrinciplePotassium Permanganate Oxidation with ORP Endpoint Detection
Range0.1–10 mg/L (multi-segment calibration)
Repeatability≤5% RSD
Accuracy±5% of reading
LOD0.4 mg/L
Resolution0.01 mg/L
Single-Test Duration13 min (water bath heating)
DisplayBacklit LCD with keypad interface
Data Storage30,000 measurement records with power-loss protection
Calibration Curves1 built-in standard curve + 96 user-defined curves
ConnectivityEthernet port + USB 2.0
OutputIntegrated thermal printer
Light SourceImported long-life cold LED (rated lifetime: 100,000 h)
Operating ModesStandard mode / Continuous measurement mode
Reagent CompatibilityDedicated pre-packaged CODMn test kits (ISO/GB-compliant)