| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Rear Exhaust Configuration |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Valve Island System |
| Detectable Elements | As, Se, Bi, Hg, Te, Sn, Ge, Pb, Zn, Cd, Au |
| Relative Standard Deviation (RSD) | < 0.8% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Bi, Sb < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control | Precise Integrated Thermal Regulation |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Disposal | Rear Exhaust Design |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn |
| RSD | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits (As, Sb, Se, Bi, Te, Hg, Sn, Pb) | <0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 100–350 °C |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Rear Exhaust Design |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Hg, Se, Sn, Bi, Sb, Pb, Ge, Cd, Te, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Bi, Sb < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 100–350 °C |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RC-800 |
| Pricing | Upon Request |
| Instrument Type | Flow Injection Analyzer (FIA) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Flow Injection Analyzer |
| Model | iFIA7 |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 85–301 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10–30 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Rear Exhaust Design |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Se, Bi, Hg, Te, Sn, Ge, Pb, Zn, Cd, Au |
| RSD | < 0.8% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Bi, Sb < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control | Yes |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Disposal | Peristaltic Pump Extraction |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Control System | Valve Island |
| Detectable Elements | As, Se, Bi, Hg, Te, Sn, Ge, Pb, Zn, Cd, Au |
| RSD | < 0.8% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Bi, Sb < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | Ambient to 1,000 °C (programmable) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | ICP-5500 |
| Detector | High-resolution overflow-resistant CCD |
| RF Source | All-solid-state self-excited 27.12 MHz generator |
| Optical System | Precision thermostatically controlled Czerny–Turner monochromator with holographic grating |
| Gas Control | Integrated automatic argon flow management module |
| Standby Mode | iStandby (reduces Ar consumption by >50%) |
| Calibration | Real-time full-spectrum calibration using interference-free Ne emission lines |
| Sample Introduction | Multi-channel high-precision peristaltic pump with integrated nebulizer and spray chamber |
| Compliance | Designed to support ISO/IEC 17025, ASTM D1976, EPA Method 200.7, USP <232>/<233>, and GLP/GMP data integrity requirements |
| Software | FPI-SpectraSuite v4.x with 21 CFR Part 11-compliant audit trail, electronic signatures, and raw data archiving |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | APNE-12 |
| Pricing | Available Upon Request |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 70 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Maximum Sample Volume per Vial | ≤200 mL |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Disposal | Peristaltic Pump Extraction |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Control System | Valve Island |
| Detectable Elements | As, Se, Bi, Hg, Te, Sn, Ge, Pb, Zn, Cd, Au |
| RSD | < 0.8% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Bi, Sb < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | Ambient to 1,000 °C (programmable) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction Method | Peristaltic Pump |
| Waste Disposal | Rear Exhaust Configuration |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Sb, Se, Bi, Te, Hg, Sn, Pb < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control | Precise PID-regulated heating |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AFS-10F |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn |
| Linear Dynamic Range | >3 orders of magnitude |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | Adjustable (Precise PID-controlled heating) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | iFIAE |
| Product Type | Flow Injection Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Volume Capacity | 10–50 mL per vial |
| Sample Tray Capacity | 50–300 positions |
| Reagent Positions | 12 |
| Flow Cell Path Length | 10 mm |
| Light Source | Tungsten Halogen Lamp |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Benchtop Laboratory Analyzer |
| Model | DMA-500 |
| Pricing | Upon Request |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Sample Introduction | Direct Solid/Liquid/Gas Injection (No Acid Digestion Required) |
| Automation | 100-Position 4-Axis Robotic Autosampler |
| Thermal Treatment | Dual-Zone PID-Controlled Ashing & Catalytic Combustion Furnace |
| Trapping System | Constant-Power Heated Mercury Trap with Rapid Thermal Ramp |
| Detection Architecture | Tandem Dual-Absorption Cells + Dual-Beam Light Source Correction |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit | Sub-ppb (µg/L) |
| Precision | RSD ≤ 0.5% |
| Wavelength Range | 165–870 nm |
| Optical Resolution | ≤ 0.007 nm @ 200 nm |
| Spectral Coverage | Simultaneous multi-element analysis across 72 elements including major metals and non-metals |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | GC-IMS 3000 |
| Pricing | Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Disposal | Rear Exhaust Configuration |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn |
| Relative Standard Deviation (RSD) | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As, Sb, Se, Bi, Te, Hg, Sn, Pb < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 100–350 °C |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Titan Instruments |
| Model | SAP-50 |
| Instrument Type | LC–AFS Hyphenated System for Elemental Speciation |
| Sample Introduction | Peristaltic Pump |
| Waste Disposal | Rear Exhaust Configuration |
| Hydride/Vapor Generation Mode | On-line Hydride Generation (HG) and Cold Vapor Generation (CVG) |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Species | As(V), As(III), MMA(V), DMA(V), AsB, AsC, p-ASA, Roxarsone |
| RSD | <4% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As(III) ≤0.04 µg/L, DMA ≤0.08 µg/L, MMA ≤0.08 µg/L, As(V) ≤0.2 µg/L, SeCys ≤0.3 µg/L, SeMeCys ≤1 µg/L, Se(IV) ≤0.3 µg/L, SeMet ≤2 µg/L |
| PMT Wavelength Range | Not specified |
| Atomizer Temperature Control Range | Not specified |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Peristaltic Pump |
| Waste Liquid Disposal | Peristaltic Pump Extraction |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Valve Island System |
| Detectable Elements | As, Se, Bi, Hg, Te, Sn, Ge, Pb, Zn, Cd, Au |
| Relative Standard Deviation (RSD) | < 0.8% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Bi, Sb < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | Ambient to 1,000 °C (programmable) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | ACOD-30 |
| Pricing | Upon Request |
| Instrument Type | Laboratory Benchtop |
| Measurement Principle | Dichromate Oxidation with Automated Potentiometric/Colorimetric Endpoint Detection (Compliant with HJ 828–2017) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Model | AFS-13U |
| Configuration | Triple-channel, fixed-lamp-position optical system |
| Sample Introduction Options | Dual sequential injection, single syringe pump + peristaltic pump, or single peristaltic pump |
| Hydride Generation | Gradient-temperature-controlled vapor generation system |
| Atomization | High-stability quartz tube atomizer with intelligent ignition (voltage-adjustable) |
| Monitoring | Real-time pressure (gas inlet/outlet), lamp current, atomic cell video feed, sample loop & reaction block temperature, waste volume, ambient pressure |
| Safety | Integrated tail-gas trapping and activated carbon exhaust adsorption |
| Connectivity | Wi-Fi, USB 2.0, LAN (RJ45), RS-232 |
| Optional Modules | Refrigerated reagent organizer, LC-AFS hyphenation interface, online acid digestion upgrade |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Model | EXPEC 7000 |
| Quotation | Upon Request |
| Deployment Mode | Mobile (Vehicle-Mounted) |
| Mass Range | 2–260 amu |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | APIA-100 |
| Pricing | Available Upon Request |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Instrument Type | Laboratory Benchtop Analyzer |
| Repeatability | RSD ≤ 3.0% |
| Limit of Detection | ≤ 0.05 mg/L |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-Channel Atomic Fluorescence Spectrometer |
| Model | AFS-13P |
| Configuration | Triple-channel, fixed-lamp-position optical system |
| Sample Introduction Modes | Dual sequential injection / Single syringe pump + peristaltic pump / Single peristaltic pump |
| Hydride Generation | Gradient-temperature-controlled vapor generation system |
| Atomization | Stable quartz-trap flame-in-quartz atomizer with intelligent ignition (voltage-adjustable) |
| Monitoring | Real-time pressure, current, temperature (reaction block, gas–liquid separator, sample loop), atmospheric pressure, waste volume, and atomicizer video feed |
| Compliance Support | Designed for GLP/GMP-aligned workflows |
| Connectivity | Wi-Fi, USB 2.0, LAN (RJ45), RS-232 |
| Optional Modules | Refrigerated reagent organizer, LC-AFS hyphenated interface, on-line microwave-assisted digestion module |