- All
- Favorite
- Popular
- Most rated
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | Atmospheric to 20 MPa |
| Extraction Cell Volumes | 1 mL, 5 mL, 10 mL, 22 mL, 34 mL, 66 mL, 100 mL |
| Cycle Time per Sample | 8–20 min |
| Dimensions | 78.3 × 67.5 × 77.3 cm |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Solid-Liquid Extraction |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | Atmospheric to 20 MPa |
| Extract Cell Volumes | 1, 5, 11, 22, 34, 46, 66, and 100 mL (8 options) |
| Extraction Cycle Time | 10–20 min per 2 samples |
| Dimensions | 655 × 720 × 725 mm (W × D × H) |
| Sample Capacity | 26 positions (24 sample + 2 rinse) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | APLE-3500 |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | Atmospheric to 20 MPa |
| Extraction Cell Volumes | 1 mL, 5 mL, 11 mL, 22 mL, 34 mL, 66 mL, 100 mL |
| Extraction Cycle Time | 15–20 min per sample |
| Dimensions (W×D×H) | 86 cm × 76 cm × 73 cm |
| Sample Capacity | 26 positions (24 sample + 2 rinse positions) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | APLE-1000 |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | Atmospheric to 18 MPa (2700 psi) |
| Extraction Cell Volumes | 1 mL, 5 mL, 10 mL, 22 mL, 34 mL, 66 mL, 100 mL, 150 mL |
| Extraction Cycle Time | 8–20 min per sample |
| Dimensions (W×D×H) | 86 × 76 × 73 cm |
| Sample Capacity | 26 positions (24 sample + 2 cleaning) |
| Heating System | Single-zone furnace with ±1 °C temperature control |
| Pressure Control | Balanced pressure regulation, active control initiated at ±0.3 MPa deviation |
| Filtration & Cleanup | Integrated inline filtration and post-extraction cleanup module |
| Safety Features | Real-time temperature/pressure monitoring with audible/visual alarm |
| Compliance | Designed in accordance with GB/T 19649–2006 for pesticide residue analysis in agricultural products |
Show next