Empowering Scientific Discovery

Beijing Titan Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTitan Instruments
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeSolid-Liquid Extraction System
Temperature RangeAmbient to 200 °C
Pressure RangeAtmospheric to 20 MPa
Extraction Cell Volumes1 mL, 5 mL, 10 mL, 22 mL, 34 mL, 66 mL, 100 mL
Cycle Time per Sample8–20 min
Dimensions78.3 × 67.5 × 77.3 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTitan Instruments
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeSolid-Liquid Extraction
Temperature RangeAmbient to 200 °C
Pressure RangeAtmospheric to 20 MPa
Extract Cell Volumes1, 5, 11, 22, 34, 46, 66, and 100 mL (8 options)
Extraction Cycle Time10–20 min per 2 samples
Dimensions655 × 720 × 725 mm (W × D × H)
Sample Capacity26 positions (24 sample + 2 rinse)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTitan Instruments
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelAPLE-3500
Instrument TypeSolid-Liquid Extraction System
Temperature RangeAmbient to 200 °C
Pressure RangeAtmospheric to 20 MPa
Extraction Cell Volumes1 mL, 5 mL, 11 mL, 22 mL, 34 mL, 66 mL, 100 mL
Extraction Cycle Time15–20 min per sample
Dimensions (W×D×H)86 cm × 76 cm × 73 cm
Sample Capacity26 positions (24 sample + 2 rinse positions)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTitan Instruments
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China)
ModelAPLE-1000
Instrument TypeSolid-Liquid Extraction System
Temperature RangeAmbient to 200 °C
Pressure RangeAtmospheric to 18 MPa (2700 psi)
Extraction Cell Volumes1 mL, 5 mL, 10 mL, 22 mL, 34 mL, 66 mL, 100 mL, 150 mL
Extraction Cycle Time8–20 min per sample
Dimensions (W×D×H)86 × 76 × 73 cm
Sample Capacity26 positions (24 sample + 2 cleaning)
Heating SystemSingle-zone furnace with ±1 °C temperature control
Pressure ControlBalanced pressure regulation, active control initiated at ±0.3 MPa deviation
Filtration & CleanupIntegrated inline filtration and post-extraction cleanup module
Safety FeaturesReal-time temperature/pressure monitoring with audible/visual alarm
ComplianceDesigned in accordance with GB/T 19649–2006 for pesticide residue analysis in agricultural products
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0