| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | AF229 |
| Light Source | CIE Illuminant C (Tungsten-Halogen Lamp) |
| Color Scale | AOCS Cc 13a-43 FAC Scale (Odd-Numbered, 1–50) |
| Viewing System | Triple-Field Visual Comparison |
| Compliance | AOCS Official Method Cc 13a-43 |
| Intended Use | Visual color assessment of dark oils, fats, tallow, lard, and rendered animal lipids |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF325 |
| Light Path | 113 mm |
| Standard Scale Range | 0–250 mg Pt/L (APHA/Hazen) |
| Compliant Standards | ASTM D1209, ISO 2211, ISO 6271, AOCS Td 1b-64, BS 5339 |
| Sample Compatibility | Clear, pale-yellow liquids |
| Calibration Method | Nessleriser 2150 comparator disc system |
| Scale Segments | NSH (10–90), NSB (70–250) |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF328 |
| Measuring Range | 0–70 mg Pt/L (Platinum-Cobalt Units) |
| Cell Path Length | 250 mm |
| Standard Discs | CAA (0–30 APHA), CAB (30–70 APHA) |
| Compliant Standards | ASTM D1209, ISO 2211, ISO 6271, AOCS Td 1b-64, BS 5339 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi995 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0002 in CIE x,y coordinates |
| Measurement Time | <30 s |
| Optical Path Length | 0.1–153 mm |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| CIE Illuminants | A, B, C, D65 |
| Observer Angles | 2°, 10° |
| Data Storage Capacity | 100,000 measurements |
| Interface | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Optional Heater | Up to 95 °C |
| Operating Voltage | 90–240 VAC (external power supply) |
| Enclosure | Steel housing with textured epoxy coating |
| Dimensions & Weight | 515 × 195 × 170 mm / 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Lovibond RYBN, AOCS, Gardner, Pt-Co/Hazen/APHA, FAC, Chlorophyll A/B, β-Carotene, Iodine, Hess-Weis, Klett (Blue filter KS-42), Kreis, CIE XYZ/L*a*b*, spectral reflectance data |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC3000 Saybolt |
| Measurement Range | –16 to +30 Saybolt |
| Resolution | 1 Saybolt Unit |
| Repeatability | ±1 Saybolt Unit |
| Path Length | 50 mm |
| Standard Compliance | ASTM D156, ASTM D6045 |
| Field of View | Triple-field viewing system |
| Cuvettes | Two 50 mm plastic cuvettes (W100), two 50 mm glass cuvettes (W100) |
| Calibration Standards | Two 60 mL certified reference liquids |
| Filter Set | Two calibrated interference filters |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | AF650 |
| Measurement Range | 0.5–8.0 ASTM Colour Scale |
| Light Source | 12 V / 20 W Halogen Tungsten Lamp (CIE Illuminant C) |
| Viewing Geometry | Triple-Field Visual Comparison |
| Cell Path Length | 33 mm |
| Standard Discs | Two Rotating Glass Filter Discs (Disc 1: 0.5, 1.5, ..., 7.5 |
| Disc 2 | 1.0, 2.0, ..., 8.0) |
| Compliance | ASTM D1500, ISO 2049, IP 196, DIN 51578, BS 5859, JIS K 2580, NF T60-104, NBN T52-109, FTM 719-102 |
| Certification | CE |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi 950 |
| Compliance | ASTM D1209, ASTM D1500, ASTM D6045, AOCS Cd 13b-97, ISO 2761, ISO 4630, ISO 6271, Gardner ASTM D1544, Saybolt ASTM D156 |
| Measurement Principles | Transmission colorimetry using tungsten-halogen light source and precision interference filters |
| Display | High-resolution LCD with multilingual interface (including English & Chinese) |
| Sample Path Length Options | 10 mm, 20 mm, 33.3 mm, 50 mm, 100 mm |
| Output Data | CIE L*a*b*, CIE XYZ, CIE Yellowness Index (YI), Whiteness Index (WI), spectral reflectance/transmittance (380–720 nm, 10 nm intervals), and proprietary color scales |
| Connectivity | RS-232, USB, optional Ethernet |
| Software Compatibility | ColorSoft™ PC software for data export, audit trail, and report generation |
| Regulatory Support | FDA 21 CFR Part 11 compliant configuration available (with user authentication, electronic signatures, and full audit trail) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Model F |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Color Scale | Lovibond RYBN |
| Red Scale | 0.1–79.9 |
| Yellow Scale | 0.1–79.9 |
| Blue Scale | 0.1–49.9 |
| Neutral Scale | 0.1–3.9 |
| Resolution | 0.1 Lovibond Unit |
| Light Source | Dual 12 V / 10 W Tungsten-Halogen Lamps |
| Illuminant Compliance | CIE Standard Illuminant C |
| Sample Chamber | Removable White Liner with Precision-Registered Cell Notch |
| Power Supply | External Low-Voltage DC Adapter |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/2 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0004 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| Illuminants | CIE A, B, C, D65 |
| Observer Angles | 2° and 10° |
| Pathlength Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Internal Memory | 100,000 measurements |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Languages | English, Chinese, French, German, Italian, Portuguese |
| Housing | Powder-coated steel enclosure |
| Dimensions & Weight | 435 × 195 × 170 mm / 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Saybolt (ASTM D6045/D156), ASTM D1500, Pt-Co/Hazen/APHA (ASTM D1209), CIE XYZ/Lab values, spectral reflectance data |
| Brand | Lovibond |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/3 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability (CIE x,y) | ±0.0004 |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Observer Angles | 2°, 10° |
| Path Length Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Data Storage Capacity | 100,000 measurements |
| Display | 240 × 128 pixel backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Housing Material | Steel enclosure with textured epoxy coating |
| Dimensions (W×H×D) | 435 × 195 × 170 mm |
| Weight | 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC3000 ASTM |
| Measurement Range | 0–8 ASTM units |
| Resolution | 0.1 unit |
| Repeatability | ±0.1 unit |
| Path Length | 33 mm |
| Standard Compliance | ASTM D1500, ASTM D6045 |
| Field of View | 3-field |
| Cuvette Types | Two 33 mm plastic cuvettes (W100), Two 33 mm glass cuvettes (W100) |
| Calibration Standards | Two 60 mL reference liquid standards |
| Filter Set | Two certified interference filters |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi 950/P |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0002 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Path Length Range | 0.1–153 mm (0.004–6 in) |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Built-in Color Scales | ASTM D1500 (Petroleum), Saybolt, CIE L*a*b*, L*C*h*, Yellowness Index (ASTM E313), Whiteness Index (CIE/ISO 11475), and Spectral Data Output |
| Calibration | One-Touch Automatic Baseline Calibration |
| Data Storage Capacity | 100,000 measurements |
| Interface Options | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile membrane keys with audible feedback, polyester overlay |
| Operating Languages | English, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Japanese |
| Housing | Steel chassis with textured epoxy coating |
| Dimensions (W×H×D) | 515 × 195 × 170 mm |
| Weight | 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| Optional Heated Cell Holder | Up to 95 °C temperature control |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF329 |
| Measuring Range | 0–250 mg Pt/L (APHA/Pt-Co Scale) |
| Cell Pathlengths | 113 mm and 250 mm |
| Standard Discs | CAA (0–30), CAB (30–70), NSB (70–250) |
| Compliant Standards | ASTM D1209, AOCS Td 1b-64, ISO 2211, ISO 6271, BS 5339 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | AF228 |
| Light Source | CIE Illuminant C (Tungsten-Halogen) |
| Gardner Scale Range | 1–18 |
| Compliance | ASTM D1544, ISO 4630, AOCS Cd 13a-97 |
| Viewing Method | Triple-Field Visual Comparison |
| Optical Path | Fixed 10.0 mm cell path |
| Standard Filters | Certified Gardner glass filters (NIST-traceable) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC2000 Pt-Co |
| Measurement Range | 0–500 Pt-Co |
| Resolution | 1 Pt-Co |
| Repeatability | ±3% or ±1 Pt-Co (whichever is greater) |
| Path Length | 50 mm |
| Standard Compliance | ASTM D1209, ISO 6271, APHA Method 2120 B, USP <631> |
| Viewing Field | Dual-field (2-field) comparator display |
| Cuvettes | 3 × plastic 50 mm cuvettes (W100), 1 × glass 50 mm cuvette (W100) |
| Calibration Standards | 60 mL certified Pt-Co reference solution |
| Filter Set | Integrated certified interference filters (traceable to NPL/UKAS) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC2000 Gardner |
| Measurement Range | 0–18 Gardner |
| Resolution | 0.1 Gardner |
| Repeatability | ±0.2 Gardner |
| Path Length | 10 mm |
| Compliance | ASTM D1544, ASTM D6166 |
| Viewing Field | Dual-field |
| Cuvettes | 3 × 10 mm plastic (W100), 1 × 10 mm glass (W100) |
| Calibration Standards | 60 mL reference liquid vial, certified filter set |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0004 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| Illuminants | CIE A, B, C, D65 |
| Observer Angles | 2° and 10° |
| Path Length Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Data Storage Capacity | 100,000 measurements |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile membrane keys with audible feedback |
| Languages | English, Chinese, French, German, Italian, Portuguese |
| Housing Material | Steel with textured epoxy coating |
| Dimensions (W×D×H) | 435 × 195 × 170 mm |
| Weight | 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Pt-Co/Hazen/APHA, Gardner, Iodine, Saybolt, ASTM Color, FAC, EBC, ASBC, ICUMSA, Pfund, ADMI, EP, USP, CIE L*C*h, Hunter Lab, spectral reflectance/data |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/1 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0004 in CIE x,y coordinates |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Path Length Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Data Storage Capacity | 100,000 measurements |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Operating Languages | English, Chinese, French, German, Italian, Portuguese |
| Housing Material | Steel with textured epoxy coating |
| Dimensions & Weight | 435 × 195 × 170 mm / 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Pt-Co/Hazen/APHA (ASTM D1209), Gardner (ASTM D1544/D6166), Iodine (DIN 6162), CIE XYZ/Lab, Spectral Reflectance Data |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | UK |
| Model | EC2000 & EC3000 |
| EC2000 Pt-Co Range | 0–500 Pt-Co, Resolution: 1 Pt-Co, Repeatability: ±3% or ±1 Pt-Co, Path Length: 50 mm, Standard: ASTM D1209 |
| EC2000 Gardner Range | 0–18 Gardner, Resolution: 0.1 Gardner, Repeatability: ±0.2 Gardner, Path Length: 10 mm, Standard: ASTM D1544, D6166 |
| EC3000 ASTM Range | 0–8 ASTM, Resolution: 0.1 ASTM, Repeatability: ±0.1 ASTM, Path Length: 33 mm, Standard: ASTM D1500, D6045 |
| EC3000 Saybolt Range | −16 to +30 Saybolt, Resolution: 1 Saybolt, Repeatability: ±1 Saybolt, Path Length: 50 mm, Standard: ASTM D156, D6045 |
| Viewing Field | 2-field (EC2000), 3-field (EC3000) |
| Cuvettes | Plastic and glass W100 cells in multiple path lengths (10 mm, 33 mm, 50 mm) |
| Calibration Standards | Bottled reference liquids (60 mL) and certified interference filters |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF327 |
| Measuring Range | 0–70 mg Pt/L (Platinum-Cobalt Units) |
| Cell Path Length | 288 mm |
| Standard Discs | 1209/1 (0–30 APHA), 1209/2 (30–70 APHA) |
| Compliant Standards | ASTM D1209, ISO 2211, ISO 6271, AOCS Td 1b-64, BS 5339 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Model Fx |
| Price Range | USD 6,800 – 13,600 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | AF607 |
| Light Source | CIE Illuminant B (Tungsten-Halogen Lamp) |
| EBC Scale Range | 2–27 |
| Resolution | 0.5 EBC units (2–10), 1.0 EBC unit (10–27) |
| Viewing Method | Triple-Field Visual Comparison |
| Compliance | EBC Method No. 4.1.1 (European Brewery Convention), ISO 4833-1:2013 (referenced for color standardization in fermented beverages) |
| Optical Path Options | Standard 10 mm, optional 20 mm and 50 mm cuvettes for extended range dilution |