Add to compare
BrandForerunner
OriginBeijing, China
ModelZDJ-2S
Titration ModeFully Automated
Method TypeDual-Mode (Coulometric & Volumetric Karl Fischer)
Measurement Resolution0.01 μA
Water Content Range0.01 mg to 100% w/w
Accuracy≤0.3% RSD
Minimum Dispensing Increment1/2000 of burette volume
Titration Control Precision0.1 μA
Drift CompensationAutomatic background drift correction (drift <5 µg H₂O/min)
Detection Limit0.01 mg H₂O
Sample FormsLiquids, solids, gases, pastes
Display & InterfaceBilingual (Chinese/English) LCD with real-time titration curve visualization
Data OutputGLP/GMP-compliant report formats (%, ppm, mg), statistical analysis capability
SoftwareEmbedded titration monitoring software with firmware upgrade support
ComplianceDesigned for ISO 8533, ASTM E203, USP <921>, and EP 2.5.12 environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandForerunner
OriginBeijing, China
ModelZDJ-3S
Titration ModeFully Automatic
Method PrincipleVolumetric & Coulometric Karl Fischer Titration
Current Resolution0.01 µA
Moisture Range10 ppm to 100% w/w
Measurement Accuracy±10 ppm
Minimum Dispensing Volume0.1 µL (1/20000 of burette volume)
Titration Control Precision0.1 µL
Polarization Voltage Output0–2550 mV (10 mV step, <±3% error)
Max Polarization Current5 mA
Current Range0–200 µA
Effective Current Accuracy±0.1 µA
Drift CompensationAuto/manual background subtraction
Data Output ComplianceGLP/GMP-compliant reporting format
InterfaceRS-232C (printer & PC connection)
Method Storage100 protocols
OptionalDead-stop titration capability with accessory kit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandForerunner
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelZDJ-600S
Titration MethodFully Automated Volumetric Titration
Instrument TypeVolumetric Karl Fischer Moisture Analyzer
Current Resolution0.01 µA
Moisture Range10 ppm to 100% w/w
Measurement Accuracy≤0.2% RSD
Minimum Dispensing Volume5 µL
Burette Precision1/20,000
Burette Capacity10 mL (standard)
Burette Accuracy±10 µL @ 10 mL
Polarization Current Range0–200 µA
Polarization Voltage Range0–2550 mV
Polarization Voltage Step10 mV
Effective Current AccuracyBetter than ±0.1 µA
Repeatability (Pure Water)<1% RSD
Standardization Repeatability±0.5% of mean across three consecutive runs