| Brand | AULTT |
|---|---|
| Model | P3000 |
| Detector | 3648-pixel linear silicon CCD |
| Wavelength Range | 200–800 nm (UV-Vis) |
| Optical Resolution (FWHM) | ≤ 0.03 nm |
| Wavelength Repeatability | < ±0.3 nm |
| Slit Width | 30 µm |
| Grating | 600 lines/mm, blazed at 250 nm |
| Interface | USB 2.0, bus-powered |
| Software Compatibility | Windows 7 and later |
| Data Export Formats | CSV, TXT, PDF, BMP |
| Spectral Acquisition Modes | Single-shot, continuous scan, spectral video |
| Calibration | Factory NIST-traceable wavelength & radiometric calibration |
| Compliance | CE, RoHS |
| Accessories Support | Modular fiber-optic coupling (SMA905), interchangeable light sources (deuterium, tungsten-halogen, LED), cuvette holders, integrating spheres, and filter kits |
| Brand | AULTT |
|---|---|
| Model | P4000 |
| Detector | 3648-pixel linear silicon CCD |
| Wavelength Range | 185–1100 nm |
| Optical Resolution (FWHM) | ≤0.03 nm |
| Wavelength Repeatability | < ±0.3 nm |
| Slit Width | 30 µm |
| Grating | 600 lines/mm, blazed at 250 nm |
| Interface | USB 2.0, bus-powered |
| Software Compatibility | Windows 7 and later |
| Compliance | CE-marked optical instrumentation, compliant with IEC 61326-1 for EMC in laboratory environments |
| Brand | AULTT |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Zhongjiao Jinyuan |
| Model | AULTT-TSP50 (Standard Integrated Temperature-Controlled) |
| Vessel Capacity | 50 mL |
| Usable Reaction Volume | 20–30 mL |
| Construction Material | Borosilicate Glass (3.3) |
| Operating Pressure | Low-pressure (atmospheric to slight positive/negative bias) |
| Sealing Interface | Standard 28/30 Ground-Glass Joint with Viton O-ring |
| Cooling/Heating Port | Dual-layer water-jacket with 10 mm BSP inlet/outlet ports |
| Vacuum Capability | Not rated for vacuum operation |
| Compliance | Designed for laboratory-scale photocatalytic screening under ambient pressure |
| Brand | AULTT |
|---|---|
| Model | AULTT-P |
| Type | Compact USB-Powered CCD Spectrometer with UV-VIS-NIR Coverage |
| Origin | Beijing, China |
| Manufacturer | Zhongjiaojinyuan (CNI) |
| Component Category | Light Source–Integrated Spectral Measurement System |
| Key Specifications | 185–1100 nm spectral range (model-dependent), 0.03 nm optical resolution, <0.3 nm wavelength repeatability, 30 µm slit, 600 lines/mm grating (optimized for UV or VIS), 2048- or 3648-pixel linear silicon CCD detector, USB 2.0 bus-powered operation |
| Software | Win7-compatible spectral acquisition & analysis suite with multi-instrument support, real-time exposure control, spectral video capture, and export to CSV, TXT, PDF, BMP |
| Compliance | Designed for laboratory-grade optical metrology in R&D, QA/QC, and educational environments |
| supports ASTM E308, CIE 15 | 2018, ISO/CIE 11664, and GLP-aligned data traceability (audit trail enabled in software log) |
| Brand | AULTT |
|---|---|
| Model | P2000 |
| Detector | 2048-pixel linear silicon CCD |
| Wavelength Range | 350–1000 nm |
| Optical Resolution (FWHM) | ≤ 0.03 nm |
| Wavelength Repeatability | < ±0.3 nm |
| Slit Width | 30 µm |
| Grating | 600 lines/mm @ 450 nm |
| Interface | USB 2.0 |
| Power Supply | Bus-powered via USB |
| Operating System | Windows 7 and later |
| Software | Integrated spectral analysis suite with multi-instrument support, exposure auto-adjustment, spectral video capture, and export to CSV, TXT, PDF, BMP |
| Brand | Admiral |
|---|---|
| Origin | USA (Designed & Engineered) / Manufactured in Partnership with Zahner (Germany) |
| Model | SquidStat Plus |
| Current Range | ±1 A |
| Voltage Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Current Resolution | down to 3 pA (0.003% of range) |
| Potential Resolution | 300 µV |
| Time Resolution | 10 µs |
| Supported Techniques | CV, LSV, OCP, CA, CC, CP, DPV, NPV, SWV, TV, RV, SV, Tafel, Pulse Plating, Stripping Voltammetry, GITT/PITT, Galvanostatic/Potentiostatic EIS, Steady-State I/V, PEIS, GEIS |
| Multi-Channel Capable | Yes (up to 16 units synchronized via single PC) |
| Onboard Data Backup Memory | Yes |
| Software | SquidStat Control Suite (drag-and-drop method builder), compatible with ZAHNER THALES analysis platform |
| Compliance | Designed for GLP/GMP-relevant workflows |
| Brand | CNIEL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | CNIEL PEC-System |
| Price | USD 57,800 (FOB Beijing) |
| Measurement Mode | DC |
| Brand | CEA-Light (CEL) |
|---|---|
| Model | HT5 |
| Type | Dual-Compartment Photoelectrochemical Reactor |
| Capacity | 100 mL (total, 50 mL per chamber) |
| Operating Pressure | Low-pressure / Ambient Pressure |
| Vacuum Capability | Atmospheric (no active vacuum system) |
| Window Material | Standard Quartz (25 mm diameter, ≥185 nm UV transmission) |
| Optional Windows | CaF₂ (down to 125 nm), KBr (IR-transmissive) |
| Electrode Compatibility | External electrodes with 6 mm outer diameter |
| Membrane Integration | Compatible with ion-exchange membranes (e.g., Nafion™) |
| Connection | DIN 25/35 ISO-K flange interface |
| Construction Material | Borosilicate glass body with PTFE-sealed stainless steel flanges |
| Application Domain | In situ photoelectrochemical (PEC) characterization, dual-compartment redox coupling, controlled potential electrolysis under illumination |
| Brand | CEL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | CEL-RCCO |
| Price | USD 2,800 (FOB Beijing) |
| Active Area | 20 mm × 20 mm |
| Spectral Response Range | 400–1100 nm |
| Calibration Irradiance | 1000 W/m² (AM1.5G) |
| Calibration Temperature | 25 °C ± 0.1 °C |
| Temperature Sensor | Calibrated Pt100 (4-wire Kelvin connection) |
| Window Material | Space-grade radiation-hardened glass |
| Encapsulation | Hermetic epoxy-sealed aluminum housing with optical-grade UV-curable adhesive |
| Output Connectors | Dual LEMO FGG.0B.304.CLAD series (Isc/Voc + Pt100) |
| Short-Circuit Current Temperature Coefficient (α) | Typically −0.05 to −0.07 mA/°C |
| Open-Circuit Voltage Temperature Coefficient (β) | Typically −1.8 to −2.2 mV/°C |
| Stability | < ±0.5% Isc drift over 1,000 h under continuous 1-sun illumination |
| Traceability | NIST-traceable calibration via accredited ISO/IEC 17025 laboratory (certificate included) |
| Brand | CEAULIGHT |
|---|---|
| Model | CEL-GPPCM |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Reaction Pressure Range | ±0.01 MPa |
| Maximum Operating Temperature | ≤800 °C |
| Catalyst Loading Capacity | 0.1 mg–100 mg |
| Gas Inlet Channels | 3 (expandable to 4) |
| Liquid Injection Port | 1 dedicated interface |
| Flow Control Accuracy | ±1% FS |
| Pressure Display Resolution | ±0.01 MPa |
| Temperature Control Accuracy | ±1 °C |
| Temperature Display Resolution | ±0.1 °C |
| Reactor Material | Fused Quartz |
| Reactor Dimensions | Compatible with standard quartz tube configurations (ID/OD specified per configuration) |
| System Footprint | 400 mm (W) × 700 mm (H) × 700 mm (D) |
| Safety Features | Dual-stage temperature & pressure alarm with automatic interlock shutdown |
| Data Logging | Real-time acquisition, timestamped storage, CSV export capability |
| Compliance Framework | Designed for GLP-aligned operation |
| Brand | CEL (Zhongjiao Jinyuan) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CEL-QPCE3000 |
| Measurement Mode | DC |
| Spectral Range | 300–1100 nm (optional 200–2500 nm) |
| Wavelength Step Resolution | ≥1 nm, continuously adjustable |
| QE/IPCE Repeatability (RSI) | <0.3% (photocurrent) |
| Chopping Frequency | 5–1000 Hz |
| Monochromator | 300 mm focal length, asymmetric Czerny-Turner design, aberration-corrected, nitrogen-purged port |
| Light Source | 500 W Xe lamp (Osram), intensity stability <0.01% |
| Detector | UV-enhanced Si photodiode (300–1100 nm) |
| Electrochemical Integration | Compatible with Ivium and other CE-compliant potentiostats |
| Sample Stage | Motorized dual-position stage (reference + sample), EMI-shielded enclosure |
| Optional Bias Light | Single- or dual-channel LED/laser bias sources |
Show next