- All
- Favorite
- Popular
- Most rated
| Brand | Hydramotion |
|---|---|
| Origin | United Kingdom |
| Model | XL7-LR |
| Measurement Range | 0–1 cP to 0–10⁹ cP |
| Accuracy | ±1% of reading or ±1 digit |
| Repeatability | ±0.3% of reading or ±1 digit |
| Response Time | 1 second |
| Temperature Range (Standard) | −50°C to +150°C |
| HT Option | −50°C to +400°C |
| Pressure Rating | Standard process-rated fittings |
| Process Connections | Tri-clamp, RJT, IDF, DIN, SMS, Varivent®, NPT, BSPP, custom flanges |
| Electrical Interface | Digital intrinsically safe (IS) output |
| Enclosure Rating | IP67 |
| Wetted Materials | Standard 316/316L stainless steel (EN 1.4401 / 1.4404) |
| optional alloys | Alloy C22 (EN 2.4602), Alloy C276 (EN 2.4819), S32750 duplex (EN 1.4410) |
| Surface Finish | Ra < 0.4 µm (electropolished standard) |
| CIP Compatibility | Fully compatible |
| Hazardous Area Certification | ATEX 2014/34/EU, IECEx Ex ia IIC T1–T6 Ga, Ex ia IIIC T135°C Da, UL/cUL Class I Div 1 Groups A–D, IS certified for Zone 0 |
| Brand | Hydramotion |
|---|---|
| Origin | United Kingdom |
| Model | XL7-HT |
| Temperature Range (HT) | –50 °C to +400+ °C |
| Viscosity Range | 0–1 mPa·s to 0–10⁹ mPa·s |
| Accuracy | ±1% of reading or ±1 digit |
| Repeatability | ±0.3% of reading or ±1 digit |
| Measurement Interval | 1 s |
| Process Connection | Customizable (flanged, threaded, sanitary clamp) |
| Electrical Output | 4–20 mA analog + digital serial (RS-485/Modbus RTU) |
| Intrinsically Safe Certification | ATEX 2014/34/EU, IECEx Ex ia IIC T1–T6 Ga, Ex ia IIIC T135 °C Da, UL Class I Div 1 Groups A–D |
| Enclosure Rating | IP67 |
| Max Cable Length | 1000 m |
| Sensor Material Standard | SS316 (EN 1.4401) / SS316L (EN 1.4404) |
| Optional Materials | Alloy C22 (EN 2.4602), Alloy C276 (EN 2.4819), S32750 Duplex (EN 1.4410) |
| Software | ViscoLink PC-based data acquisition & logging |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XL-3124ET-E234 |
| Viscosity Range | 0–1,000,000,000 cP |
| Accuracy | ±1% of reading |
| Temperature Range | −40 °C to +400 °C |
| Temp. Accuracy | ±1.0% of span |
| Max. Process Pressure | 70 MPa |
| Power Supply | 24 VDC |
| Output Signal | 4–20 mA analog (linear, HART-compatible) |
| Shear Rate Control | Configurable, continuous real-time measurement |
| Brand | Hydramotion |
|---|---|
| Origin | United Kingdom |
| Model | XL7 |
| Measurement Range | 0–10 cP |
| Accuracy | ±1% of reading |
| Temperature Range | −50 to +400 °C |
| Pressure Rating | 700 bar |
| Sensor Repeatability | ±0.3% |
| Process Connections | Customizable flanged, threaded, or sanitary clamp interfaces |
| Wetted Materials | Super Duplex Stainless Steel (S32750 / UNS S32750, marketed as SAR2507) |
| Sensor IP Rating | IP67 |
| Transmitter IP Rating | IP65 |
| Safety Certifications | ATEX II 2G Ex ia IIC T1–T6 Ga, IECEx Ex ia IIC T1–T6, UKCA, CE, ISO 9001 certified |
| Electrical Supply | 24 VDC ±10%, 150 mA max |
| Analog Outputs | Three isolated 4–20 mA outputs (e.g., dynamic viscosity, intrinsic viscosity, temperature-compensated viscosity) |
| Digital Interfaces | RS485 Modbus RTU, USB for configuration and diagnostics |
| Alarm Outputs | Two voltage-free relay contacts (SPST, 250 VAC/30 VDC, 2 A) |
| Dimensions (Transmitter) | 200 × 120 × 90 mm |
| Enclosure Material | Polycarbonate (UL94 V-0 rated) |
| Weight | 920 g |
Show next