1 mK
Filter
Showing 31–60 of 64 results
| Brand | — |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | KQ-500GVDV |
| Instrument Type | General-Purpose |
| Capacity | 27 L |
| Dimensions (W×D×H) | 910 × 490 × 540 mm |
| Inner Tank Dimensions | 500 × 300 × 180 mm |
| Ultrasonic Frequencies | 45 kHz / 80 kHz |
| Adjustable Ultrasonic Time | 1–999 s |
| Ultrasonic Power Output | 500 W (40–100% adjustable) |
| Heating Power | 800 W |
| Cooling Power | 350 W |
| Temperature Control Range | 0–80 °C |
| Temperature Stability | ±2 °C |
| Water Level Monitoring | Yes |
| Power Supply | 220 V / 50 Hz |
| Accessories | Stainless Steel Basket, Acoustic Lid, Electric Inlet/Drain Control |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic |
| Model | Liar Hawk |
| Pricing | Upon Request |
| Flight Platform | VTOL Fixed-Wing UAV |
| Propulsion | All-Electric |
| Endurance | 1.5 h |
| Cruise Speed | 70–80 km/h |
| LiDAR Sensor | RIEGL VUX-1LR |
| Vertical Absolute Accuracy | 5 cm @ 200 m AGL |
| Measurement Range | 5–1350 m (≥60% reflectivity) |
| Ranging Accuracy | ±1.5 cm |
| FOV | 330° |
| Scan Frequency | 10–200 Hz |
| Angular Resolution | 0.001° |
| Max Effective Point Rate | 750,000 pts/sec (@820 kHz PRR & 330° FOV) |
| GNSS Constellations | GPS, GLONASS, Galileo, BeiDou |
| Post-Processed Attitude Accuracy | 0.006° (1σ) |
| Post-Processed Heading Accuracy | 0.019° (1σ) |
| System Weight | 5.3 kg |
| Software Suite | Onboard LiDAR Control & GNSS/INS Data Processing Software |
| Optional | Point Cloud Analysis Software |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Model | LiDAR X3 |
| Quotation | Upon Request |
| Operating Wavelength | 905 nm |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | Light 915 |
| Instrument Type | Portable |
| Detection Principle | Zeeman Atomic Absorption Spectroscopy with High-Frequency Modulated Polarized Light (ZAAS-HFM) |
| Wavelength | 254 nm |
| Detection Limit | <0.1 µg/m³ |
| Operating Duration | Up to 12 h on rechargeable battery |
| Dynamic Range | 5 orders of magnitude |
| Data Storage | Internal memory with USB and Bluetooth export |
| Regulatory Status | Listed on U.S. EPA Emergency Response Equipment List |
| Compliance | Designed for compliance with OSHA PEL, ACGIH TLV, and ISO 6879 for elemental mercury vapor monitoring |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (PRC) |
| Model | LQ-5Z |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LQ-5Z-Multi |
| Pricing | Available Upon Request |
| Measurement Principle | Electrode-Based (Grab Sampling) |
| Measurement Range | TMAH: 0.00–5.0% / 0.0–50.0 g/L |
| NaOH | 0.00–3.00% / 0.0–30.0 g/L |
| Na₂CO₃ | 0.0–10.0% / 0–100 g/L |
| NH₃ | 0.0–2.00% / 0.0–20.0 g/L |
| H₂SO₄ | 0.0–2.00% / 0.0–20.0 g/L |
| HNO₃ | 0.0–2.00% / 0.0–20.0 g/L |
| Sample Temperature | 0.0–40.0 °C |
| Accuracy | ±5% FS |
| Calibration | Zero and Span Calibration |
| Temperature Compensation | Automatic |
| Enclosure Rating | IP66 |
| Power Supply | 3×AAA batteries with auto power-off |
| Electrode Type | 4C-type, 1 m standard cable |
| Dimensions (Instrument) | 75(W)×180(D)×38(H) mm |
| Electrode Dimensions | φ17×180(L) mm |
| Weight (Instrument) | ~300 g |
| Weight (Electrode) | ~50 g |
| Standard Kit | Analyzer with batteries, 4C electrode, user manual, certificate of conformity |
| Brand | -- |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic |
| Model | Lynsys |
| Pricing | Upon Request |
| Brand | — |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | Ni-502 |
| Pricing | Available Upon Request |
| Measurement Principle | Absorption Photometry (UV-Vis, 540–560 nm) |
| Detection Range | High Range: 0.0–199.9 g/L Ni |
| Low Range | 0.00–19.99 g/L Ni |
| Resolution | 0.1 g/L (high), 0.01 g/L (low) |
| Accuracy | ±2% FS |
| Operating Temp. | 0–40 °C, ≤85% RH |
| Output | Isolated 4–20 mA DC (3-range switchable: 0–50/100/200 g/L or 0–5/10/20 g/L) |
| Relay Outputs | Two SPDT dry contacts (AC 200 V, 1 A resistive load) |
| Power Supply | AC 85–240 V, 50/60 Hz |
| Enclosure | IP65-rated panel-mount housing (96 × 96 × 163 mm, ~1.3 kg) |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region | Domestic (China) |
| Model | OLM30B |
| Pricing | Available Upon Request |
| Flow Resolution | 0.01 L/min |
| Repeatability | ±1% FS |
| Maximum Flow Rate | 0–2 L/min |
| Power Supply | 110/220 V AC, 50/60 Hz |
| Power Consumption | 500 W |
| Operating Temperature Range | –10 °C to +50 °C |
| Weight | Air Pump Unit — 6.8 kg |
| Compliance | EPA Method 30B |
| Brand | -- |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OPTIMA 7 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | Electrochemical Sensor (O₂, CO, NOₓ, SO₂, H₂S) |
| Accuracy | ≤ ±1% of full scale |
| Repeatability | ≤ 0.5% (typical, per ISO 12039 & EN 15267-3) |
| Response Time (T₉₀) | ≤ 10 s |
| Drift Stability | ≤ 1% FS/week |
| Measurable Gases | O₂, CO (low/high/very high), CO₂, NO, NO₂, NOₓ, SO₂, H₂S, flue gas temperature (0–1100 °C), ambient air temperature (0–100 °C), differential pressure (±100 hPa), static pressure (±100 hPa), flue gas velocity (3–100 m/s) |
| Display | 3.5″ color TFT LCD with LED backlight & zoom function |
| Data Storage | 16,000 internal records |
| Connectivity | Mini-USB (data transfer & charging), IrDA (infrared printer interface), optional Bluetooth 4.0 |
| Filtration | Integrated PTFE-reusable particulate filter + water separator |
| Gas Path | Stainless steel sampling probe & fittings |
| Power | Rechargeable Li-ion battery (≥6 h standard |
| Weight | < 800 g (main unit only) |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (PRC) |
| Model | PhenoTron® PTS |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PMT-2500 |
| Pricing | Available Upon Request |
| Detection Principle | Laser Light Scattering (90° scattering geometry) |
| Alarm Indicator | Tri-color LED (Green/Yellow/Red) with stepwise activation based on PM2.5 concentration thresholds |
| Power Supply | 3× AA alkaline batteries (internal) or DC 5 V via included USB cable |
| Display | 4-digit 7-segment LED |
| Accuracy | ±15 µg/m³ (for concentrations <100 µg/m³), ±15% (for ≥100 µg/m³) |
| Response Time | ≤6 seconds (T90) |
| Operating Temperature | −10 °C to +50 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Power Consumption | 0.6 W (active), 0.1 W (standby) |
| Data Logging | User-selectable intervals (1/5/10/30/60 min) |
| Dimensions | 81(W) × 40(H) × 141(D) mm |
| Weight | ≈345 g (including batteries and silicone rubber cover) |
| Accessories | USB cable (15 cm), AA batteries, protective silicone cover |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Power Plant Seawater Radiation Environmental Monitoring System |
| Pricing | Upon Request |
| Instrument Class | Dose Rate Meter / Activity Monitor |
| Instrument Type | Online Continuous Monitoring System |
| Measured Medium | Liquid (Seawater) |
| Brand | -- |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QA-3000 |
| Price | Upon Request |
| Input Range | ±60 g |
| Bias | <4 mg |
| One-Year Composite Repeatability | <40 µg (QA3000-030), <80 µg (QA3000-020), <125 µg (QA3000-010) |
| Temperature Sensitivity | <15 µg/°C (QA3000-030 & QA3000-020), <25 µg/°C (QA3000-010) |
| Scale Factor | 1.20–1.46 mA/g |
| Axis Misalignment | <1000 µrad (QA3000-030 & QA3000-020), <1500 µrad (QA3000-010) |
| Vibration Rectification | <10 µg/°rms (50–500 Hz), <35 µg/°rms (500–2000 Hz) |
| Intrinsic Noise | <7 µg/rms (0–10 Hz), <70 µg/rms (10–500 Hz), <1500 µg/rms (500–10,000 Hz) |
| Operating Temperature Range | –28 to +78 °C (QA3000-030), –55 to +85 °C (QA3000-020 & QA3000-010) |
| Shock Resistance | 100 g (QA3000-030), 150 g (QA3000-020 & QA3000-010) |
| Vibration Rating | 15 g peak sine (20–2000 Hz) |
| Resolution/Threshold | <1 µg |
| Bandwidth | >300 Hz |
| Thermal Modeling | Yes |
| Quiescent Current | <16 mA per supply |
| Quiescent Power | <480 mW @ ±15 VDC |
| Electrical Interface | Voltage Self-Test, Current Self-Test, Temp Sensor, –10 VDC Output, Power/Signal Ground |
| Input Voltage | ±13 to ±28 VDC |
| Weight | 7 g ±4 g |
| Diameter Below Mounting Surface | ≤1.005 in |
| Height (Bottom to Mounting Surface) | ≤0.585 in |
| Case Material | 300 Series Stainless Steel |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | RA-915J |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CRM-100 |
| Instrument Type | Portable Dose Rate Meter |
| Measured Radiation Types | Alpha (α), Beta (β), Gamma (γ), and X-ray |
| Detector | Halogen-quenched Geiger-Müller Tube with Mica End-window (1.75″ / 45 mm diameter, density 1.5–2.0 mg/cm²) |
| Wall Material | 0.012″ stainless steel (Grade 446) |
| Energy Range | 20 keV – 3 MeV |
| Dose Rate Range | 0.001–110.0 mR/h or 0.01–1100 µSv/h |
| Count Rate Range | 0–3,500 CPS / 0–350,000 CPM |
| Total Count Capacity | Up to 9,999,000 counts |
| Timer Range | Up to 40 hours |
| Sensitivity | ≥1000 CPM per mR/h (referenced to Cs-137) |
| Accuracy | ±10% typical, ±15% maximum (mR/h and µSv/h modes) |
| Display | 4-digit LCD with mode indicators |
| Audio Feedback | Adjustable click-per-count (muteable) |
| Visual Feedback | LED flash per count |
| Interface | 3.5 mm output jack (CMOS-compatible TTL pulses) |
| Power | One 9 V alkaline battery (typical lifespan: 2160 hours) |
| Dimensions | 150 × 80 × 30 mm |
| Weight | 225 g (including battery) |
| Certifications | CE, RoHS, WEEE, ISO 9001:2001 & ISO 14001 |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Radioisotope Source Capsule Automatic Inspection System |
| Pricing | Available Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RC-V2 |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Revolution cf/ctDNA |
| Price | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | General Distributor |
| Model | YK100510 |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | RP-92 |
| Pricing | Upon Request |
| Instrument Type | Online/Field-Deployable |
| Analytical Principle | Cold Vapor Atomic Fluorescence Spectrometry (CV-AFS) |
| Brand | — |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | S-16 |
| Typical Configuration | Integrated Particulate Imaging Sampler |
| Dimensions | 120 × 70 × 40 mm |
| Weight | 0.35 kg |
| Power Supply | 12 V DC |
| Power Consumption | 5 W |
| Operating Temperature | 0–60 °C |
| Operating Humidity | 0–80 % RH (non-condensing) |
| Acoustic Noise | ≤10 dB(A) at 1 m |
| Battery Runtime | Up to 1.5 h (rechargeable Li-ion integrated) |
| Brand | -- |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SAP500 Series |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SCG-N |
| Price Range | USD 14,000–42,000 (FOB) |
| Instrument Type | Soil Moisture / Water Potential Analyzer |
| CO₂ Measurement Principle | NDIR (Non-Dispersive Infrared), Single-Beam Dual-Wavelength |
| Standard Depth Layers | 3 |
| Data Logger | 16-Channel (expandable to 32) |
| Power Supply | Rechargeable Li-ion Battery or Solar Panel |
| Wireless Connectivity | 4G LTE Full-Band Module (backward-compatible with EDGE/GPRS) |
| Compliance | Designed for GLP-aligned field research |
| Brand | -- |
|---|---|
| Origin | Japan |
| Manufacturer Type | General Distributor |
| Origin Category | Imported |
| Model | IPCE |
| Quotation | Upon Request |
| Measurement Mode | AC |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 4420 Series L-Type |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | 4380 Series L-Type |
| Pricing | Upon Request |
| Dimensions (in/mm) | 2.86 × 6.36 in (72.64 × 162.54 mm) |
| Mass | 0.35 lb (0.159 kg) |
| Max Calibrated Equivalent Airspeed | 450 knots |
| Heating | Integrated heater for total pressure port |
| Aircraft Compatibility | Fixed-wing aircraft, rotary-wing aircraft, UAVs |
| Mechanical Interface | Requires AN5812 and AN5814 fittings |
| Documentation | CAD models and dimensional/technical specification PDF available |
| Brand | -- |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ultrasonic Valve Leak Detection System |
| Pricing | Available Upon Request |
| Brand | -- |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DC1500-U |
| Price | Upon Request |
| Brand | — |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Vehicle Tilt Alarm Sensor |
| Pricing | Upon Request |