Particulate Matter Sampler
Filter
Showing 1–30 of 45 results
| Brand | AirMetrics |
|---|---|
| Origin | USA |
| Model | MiniVol TAS |
| Flow Range | 0–10 L/min |
| Pressure Capability | >30,000 Pa |
| Flow Stability | ±5% |
| Max Flow Error | ±5% |
| Continuous Operation Time at Max Flow & Backpressure | 60 h |
| Dimensions (Sampler) | 25.4 × 30.5 × 17.8 cm |
| Weight (Fully Configured) | 4.45 kg |
| Battery | 14.8 V / 118 Wh Li-ion (≥60 h runtime, 5 h recharge) |
| Filter Format | 47 mm cassette (EPA FRM-compliant) |
| Inlet Type | EPA FRM-designated PM₁₀ or PM₂.₅ cyclonic separator |
| Power Options | AC/DC adapter (100–240 VAC, 47–63 Hz) or solar-compatible |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BTPM-HS10 |
| Flow Rate | 16.67 L/min |
| Maximum Vacuum Pressure | 35 kPa |
| Flow Stability | <1% RSD |
| Maximum Flow Error | ±1% |
| Operational Lifetime at Max Flow & Backpressure | 6000 h |
| Filter Capacity | 10 × 47 mm |
| Sampling Duration per Filter | 1–99 h (programmable) |
| Data Storage | 4 GB SD card (≥10 years of operational logs) |
| Operating Temperature | −30 to +50 °C |
| Relative Humidity Range | 0–100% RH |
| Acoustic Noise Level | ≤53 dB(A) |
| Power Supply | AC 220 V / 50 Hz, 400 W |
| Optional Low-Temperature Module | Yes |
| Compliance | HJ 93–2013, HJ 656–2013, HJ 618–2011, Environmental Air Quality Monitoring Specification (Trial) |
| Brand | BGI |
|---|---|
| Origin | USA |
| Model | deltaCal DC1 & tetraCal TC5 |
| Flow Range (deltaCal) | 1.5–19.5 L/min |
| Flow Range (tetraCal) | 0.1–30.0 L/min |
| Operating Temperature | −30 °C to +55 °C |
| Barometric Pressure Range | 400–800 mmHg (534–1066 hPa) |
| Temperature Measurement Range | −40 °C to +55 °C |
| Power | 4×AA batteries (20 hr) or universal 120/240 VAC adapter |
| Certifications | NIST-traceable calibration, ISO 9001 certified, compliant with U.S. EPA PM2.5/PM10 field verification requirements |
| Brand | BGI |
|---|---|
| Origin | USA |
| Model | PQ167HA |
| Operating Altitude | up to 15,000 ft (4,572 m) |
| Flow Rate | 5.0 L/min (±2% accuracy) |
| Sampling Duration | 24 h on internal DC battery |
| Particle Size Cutpoints | TSP, PM10, PM4.0, PM2.5, PM1.0 |
| Filter Format | 47 mm diameter membrane |
| Compliance | U.S. EPA Federal Reference Method (FRM) for PM2.5 |
| Sampling Head | BGI miniPM with integrated water separator |
| Power Options | Internal rechargeable DC battery + AC adapter |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dr. Drenda APM-2 |
| Pricing | Upon Request |
| Flow Rate | 3.3 L/min |
| Sampling Mode | Continuous |
| Power Supply | 230 V, 50/60 Hz |
| Power Consumption | ~80 VA |
| Measurement Range | 0–1000 µg/m³ |
| Dimensions (W×H×D, excl. inlet & antenna) | 300 × 450 × 250 mm |
| Weight | ~17 kg |
| Ingress Protection | IP65 |
| Brand | Eigenbrodt |
|---|---|
| Origin | Germany |
| Model | NILU SF 1 |
| Construction Material | HD-polyethylene |
| Support Frame | Stainless Steel |
| Collection Aperture Diameter | 200 mm (ISO-compliant) |
| Total Height | 400 mm (ISO-compliant) |
| Adjustable Mounting Height | 1.7–2.6 m above ground level (incl. ISO reference height) |
| Standard Kit | Sampler body with lid, stainless steel retaining ring, nested basket, ground stakes |
| Optional Accessories | Telescopic ground anchors (for rocky or paved surfaces), individual component replacement parts |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | PMS-200 |
| Configuration | Dual-Channel Integrated Sampler |
| Flow Rate | Single-Channel: 16.67 L/min |
| Dual-Channel | 15 L/min (PM₂.₅) and 16.67 L/min (PM₁₀–PM₂.₅) |
| Vacuum Pressure Range | 80–106 kPa |
| Flow Stability | ≤2% of setpoint over 24 h |
| Maximum Flow Accuracy | ±2% of setpoint |
| Continuous Operation at Max Flow & Backpressure | 24 h |
| Service Life Under Max Load & Resistance | 2–3 years |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PMS-200A |
| Configuration | Integrated Low-Flow PM Sampler |
| Nominal Flow Rate | 16.67 L/min |
| PM10 & PM2.5 Fractionation | Equipped with ISO/EPA-compliant impactor or cyclonic PM2.5 separator |
| Filter Capacity | 16 pre-loaded filters per cassette |
| Automation | Pneumatically actuated filter exchange |
| Environmental Operating Range | -30 °C to +50 °C with active thermal regulation |
| Data Interface | RS-232, USB, and GPRS telemetry |
| Compliance | Designed to meet EPA Reference Method EQPM-0899-004, ISO 23270:2023 (Ambient air — Measurement of mass concentration of PM2.5 and PM10), and Chinese HJ 93-2013 technical specifications |
| Brand | Guo Ruili Heng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Producer |
| Model | GR-1350B |
| Flow Range | 24-hr Gaseous Sampling: 0.20 L/min |
| Particulate Sampling | (60–130) L/min |
| Maximum Vacuum Pressure | >9 kPa |
| Flow Stability | ±2.5% (RSD) |
| Max Flow Error | ≤2.5% |
| Operational Duration at Max Flow & Load | 4–6 h |
| Rated Service Life at Max Flow & Load | >10,000 h |
| PM2.5 Cut-Point (Da₅₀) | (2.5 ± 0.2) µm, σg = (1.2 ± 0.1) |
| PM10 Cut-Point (Da₅₀) | (10 ± 0.5) µm, σg = (1.5 ± 0.1) |
| Inlet Velocity | 0.3 m/s |
| b/a Ratio | 0.625 |
| Nominal Particulate Flow | 100 L/min |
| Filter Diameter | Ø80 mm |
| Thread Connection | M20×1.5 |
| Temperature Control Range | 15–30 °C (PID-regulated, ±0.5 °C accuracy) |
| Ambient Pressure Measurement | (60–130) kPa, resolution 0.01 kPa, accuracy ±2.5% |
| Time Accuracy | ±0.2% over 1 min–99 h 59 min |
| Noise Level | <62 dB(A) |
| Dimensions (W×D×H) | 210 × 320 × 270 mm |
| Weight | ~7.0 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | <100 W |
| Brand | HUANKONG |
|---|---|
| Model | GHD-M |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Flow Range | 0–16.7 L/min |
| Maximum Flow Error | ±1% |
| Filter Diameter | 47 mm |
| Compliance | HJ 93–2013, HJ 656–2013, HJ 618–2011, Ambient Air Quality Monitoring Regulation (Trial) |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GHD-SM4 |
| Configuration | Integrated Quad-Channel Particulate Sampler |
| Compliance | JJG 943–2011, HJ 93–2013, HJ 656–2013, HJ 618–2011 |
| Sampling Modes | Immediate, Timed, Interval |
| Flow Control | Independent PID-regulated mass flow control per channel |
| Pump Type | Brushless DC vacuum pumps |
| Data Interface | RS232, USB, Built-in thermal printer |
| Environmental Sensors | Ambient temperature, barometric pressure, actual flow (m³/min), standardized flow (m³/min at 25°C & 101.325 kPa) |
| Protection Features | Overload shutdown, power-fail memory retention |
| Particle Size Cuts | TSP, PM₁₀, PM₂.₅, PM₁ (via certified impactor or filter-based separation stages) |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GHK-1300Q |
| Configuration | Integrated Ambient Air Sampler |
| Flow Range | 10–230 L/min |
| Maximum Flow Accuracy | ±0.1% (full scale) |
| Operating Duration at Max Flow & High Backpressure | ≥8 h |
| Service Life at Max Flow & High Backpressure | ≥5,000 h |
| Vacuum Capacity | ≥30 kPa (typical at 200 L/min with 47 mm PTFE membrane) |
| Compliance | HJ 93–2013, HJ 618–2011, HJ 956–2018, HJ 691–2014, GB/T 39193–2020, JJG 943–2011 |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHK-2034 |
| Configuration | Integrated Gas Sampling System |
| Flow Range | Programmable |
| Vacuum/Pressure Range | −20 to +20 kPa |
| Flow Stability | Better than ±0.1% |
| Power Supply | Built-in High-Capacity Lithium Battery (supports heated probe & trace-heated line operation) |
| Data Storage | 500 sample records with timestamp, flow setpoint, pressure profile, and bag ID tracking |
| Display | Backlit LCD with Chinese UI |
| Housing Material | Transparent, UV-stabilized polycarbonate vacuum chamber |
| Tubing & Fittings | PTFE-only gas pathway — zero metal contact from probe inlet to bag outlet |
| Compliance | HJ 1262–2022, HJ 732–2014, HJ/T 397–2007, HJ/T 55–2000 |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GHK-2050 |
| Configuration | Integrated Dilution Sampling System |
| Compliance | GB/T 16157, Technical Guidelines for Source Apportionment Monitoring of Ambient Particulate Matter (2020) |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GHK-2051 |
| Pricing | Upon Request |
| Typical Configuration | Integrated Dilution Sampling System |
| Flow Range | 1–150 L/min |
| Brand | Metrohm |
|---|---|
| Model | PILS |
| Origin | Imported (Switzerland/USA) |
| Manufacturer | Metrohm AG (via Applikon BV) |
| Power Supply | 110–240 V, 50/60 Hz |
| Sampling Time | 15 min – 1 h |
| Aerosol Size Range | 0.01–10 µm |
| Liquid Collection Medium | Deionized Water |
| Compatibility | Ion Chromatography (IC), including Metrohm and third-party systems |
| Internal Standard Integration | Yes |
| Self-Cleaning Function | Yes |
| Flow Rate Limiting | 1 m³/h |
| Compliance | Designed for GLP/GMP-aligned environmental monitoring workflows |
| Brand | Minhope |
|---|---|
| Model | MH1200-G |
| Origin | Shandong, China |
| Instrument Type | Integrated Ambient Air Sampler for TSP, PM₁₀, PM₂.₅, Heavy Metals, Fluorides, and Semi-Volatile Organic Compounds (SVOCs) |
| Compliance | JJG 943–2011, HJ 618–2011, HJ 93–2013, HJ 691–2014 |
| Operating Modes | Instant, Timed, and Volume-Based Sampling |
| Environmental Parameter Compensation | Real-time Temperature & Barometric Pressure Measurement with Flow Correction |
| Enclosure | Weather-Resistant, Compact, Low-Noise Design |
| Power Consumption | Low |
| Weight | Lightweight for Field Deployment |
| Brand | — |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | S-16 |
| Typical Configuration | Integrated Particulate Imaging Sampler |
| Dimensions | 120 × 70 × 40 mm |
| Weight | 0.35 kg |
| Power Supply | 12 V DC |
| Power Consumption | 5 W |
| Operating Temperature | 0–60 °C |
| Operating Humidity | 0–80 % RH (non-condensing) |
| Acoustic Noise | ≤10 dB(A) at 1 m |
| Battery Runtime | Up to 1.5 h (rechargeable Li-ion integrated) |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | IMPACT |
| Flow Rate | 10 L/min |
| Filter Diameter | 47 mm |
| Compatible Pump | Leland Legacy (recommended) |
| Sampling Target | PM₁₀, PM₂.₅, and PM₁₀–₂.₅ fractionated collection |
| Impact Substrate | Pre-oiled disposable impaction plate |
| Design | Removable filter holder, rain shield optional, rapid-mount bracket optional |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | IOM |
| Sampling Flow Rate | 2 L/min |
| 50% Cut-Point | 100 µm (at 2 L/min) |
| Filter Diameter | 25 mm |
| Housing Material | Heat-resistant polypropylene (plastic) or stainless steel |
| Max Operating Temperature | 100 °C (plastic), 200 °C (stainless steel) |
| Weight | <55 g (plastic version, including cassette) |
| Dimensions | 8.5 × 2.8 cm |
| Inlet Tubing ID | 6.25 mm (1/4″) |
| Compliance | ACGIH Inhalable Fraction, ISO/CEN EN 13205, HSE MDHS 14/4, MDHS 6/3 (with accessory head), MDHS 25/3 (stainless only), NIOSH Method 5700, OSHA PNOR, Australian Inhalable PM Standard |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | PEM |
| Flow Rates | 2, 4, or 10 L/min |
| Filter Diameter | 37 mm |
| Compliance | EPA Method IP-10A |
| Recommended Pumps | AirChek TOUCH (220–5000TC) for 2 & 4 L/min |
| Filter Type | PTFE membrane |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | PMI Series |
| Flow Rate | 3 L/min |
| Cut-Point | 10 µm (PM₁₀) or 2.5 µm (PM₂.₅) |
| Filter Diameter | 37 mm |
| Impactor Substrate | 25 mm disposable pre-oiled porous plastic disk |
| Weight | 71 g |
| Compliance | EPA-defined PM₂.₅ and PM₁₀ sampling criteria |
| Brand | TaiKun |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TK-2020 |
| Typical Configuration | Integrated High-Flow Particulate Sampler |
| Flow Range | 0–20,000 L/min |
| Vacuum Pressure Capability | Up to 2.0 kPa (not L/min — corrected per engineering standard) |
| Continuous Operation Duration at Rated High Flow & Resistance | 24 h |
| Service Life at Maximum Flow and System Backpressure | 168 h |
| Basis Weight | 40 g/m² |
| Thickness | 0.2 mm |
| Filtration Efficiency | 99.995% (NaCl aerosol, 0.3–0.5 µm, face velocity 0.1 m/s, test area 50 cm²) |
| Initial Pressure Drop | 137 Pa (same test conditions) |
| Material | Electrostatically Charged Polypropylene |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MFC-TSP |
| Typical Configuration | Total Suspended Particulates (TSP) Sampling System |
| Flow Rate Range | 1.13 m³/min (40 ACFM) |
| Flow Accuracy | < ±1% deviation over 24 h |
| Pressure Drop Compensation | Aerodynamically optimized critical-flow Venturi restrictor |
| Flow Stability | Independent of filter loading, ambient temperature, and barometric pressure |
| Power Supply | 110 VAC, single-phase, 60 Hz (optional configurations available) |
| Motor | 1.0 HP, 7 A, 840 W |
| Weight | 62 kg (total system) |
| Cabinet | 22 kg |
| Cyclone/Cut-point Assembly | 25 kg |
| Blower & Filter Holder | 12 kg |
| Dimensions (Cabinet) | 129 cm H × 56 cm W × 56 cm D |
| Dimensions (Cyclone) | 81 cm H × 81 cm W × 63.5 cm D |
| Dimensions (Blower + Filter Holder) | 71 cm H × 53 cm W × 48 cm D |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model Series | Partisol |
| Typical Configuration | Total Suspended Particulates (TSP) Sampler |
| Flow Range | Not Specified |
| Vacuum Pressure Capability | Not Specified |
| Flow Stability | Not Specified |
| Maximum Flow Error | Not Specified |
| Operational Duration at High Flow & High Backpressure | Not Specified |
| Service Life at Maximum Flow & Backpressure | Not Specified |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | VFC-PM10 |
| Typical Configuration | PM₁₀ Inhalable Particulate Sampler |
| Flow Rate | 40 ACFM (1.13 m³/min) |
| Flow Accuracy | < ±1% deviation over 24 h |
| Motor | 1.0 HP, 7 A, 840 W |
| Power Supply | 110 V AC, single-phase, 60 Hz (optional configurations available) |
| Weight | 62 kg (total system) |
| Dimensions | Cabinet: 129 cm H × 56 cm W × 56 cm D (22 kg) |
| PM₁₀ Cyclone | 81 cm H × 81 cm W × 63.5 cm D (25 kg) |
| VFC Fan & Filter Holder Assembly | 71 cm H × 53 cm W × 48 cm D (12 kg) |
| Flow Control Principle | Critical-flow Venturi with aerodynamic energy recovery |
| Compliance | U.S. EPA Reference Method RFPS-1287-063 for PM₁₀ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | 20-810 |
| Typical Configuration | Integrated Sampling System |
| Flow Rate | 28.3 L/min (1 CFM, calibrated) |
| Staged Aerodynamic Cut-Points (at 28.3 L/min) | 9.0, 5.8, 4.7, 3.3, 2.1, 1.1, 0.7, 0.4 µm |
| Sampler Height | 21.6 cm |
| Sampler Diameter | 9.5 cm |
| Sampler Weight | 1.6 kg |
| Pump Dimensions | 24.1 × 14.0 × 11.4 cm |
| Pump Weight | 3.9 kg |
| Sampling Media Compatibility | Glass slides, stainless steel plates, membrane filters (e.g., PVC, PTFE, polycarbonate) |
| Compliance | Designed for ASTM D1424, ISO 14644-1, USP <788>, and EPA Compendium Method TO-13A applications |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ChemComb 3500 |
| Configuration | Integrated Multi-Phase Sampling Cartridge |
| Flow Rate | 10 L/min (PM₂.₅/PM₁₀ mode) |
| Diffusion Tube Material | Borosilicate Glass |
| Diffusion Tube Dimensions | Ø47 mm × 38 mm, ~212 hexagonal channels per unit, channel side length ≈ 2 mm, internal surface area ≈ 775 cm² |
| Filter Format | Four-stage 47 mm filter holder (PTFE construction) |
| Inlet Options | Anodized Aluminum or PTFE-coated PM₂.₅ (10 & 16.7 L/min) and PM₁₀ (10 L/min) cyclones |
| Organic Sorbent Stages | Optional PUF and/or XAD-2 resin beds downstream of filters |
| External Diameter (excl. clamps) | 7.49 cm |
| External Diameter (incl. clamps) | 9.68 cm |
| Length (inlet to 1/4″ quick-connect outlet) | 28.27 cm |
| Weight (empty) | 1.23 kg |
| Weight (with two diffusion tubes) | 1.45 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Reference/Equivalent Method PM Sampler |
| Models | Partisol 2000i (single-channel), Partisol 2000i-D (dual-channel) |
| Flow Control | Mass Flow Controller (MFC) |
| Fine Particle Flow Rate | 15 L/min (2000i-D), Coarse Particle Flow Rate: 1.67 L/min (2000i-D) |
| Total Flow Range | 5–17 L/min (2000i) |
| Data Storage | 86 days @ 5-min intervals, 32 filter records |
| Operating Temperature | −40 °C to +50 °C |
| Power | 1.1 A @ 240 VAC |
| Dimensions (H×W×D) | 1620 mm × 1175 mm × 927.5 mm (base unit) |
| Weight | 37.2 kg (2000i), 38.6 kg (2000i-D) |
| Compliance | U.S. EPA RFPS-0498-117 (PM₂.₅), RFPS-1298-126 (PM₁₀), RFPS-0509-175 (Coarse PM) |
| Filter Format | Dual 47 mm filter holders (2000i-D), single 47 mm holder (2000i) |
| Cut Points | PM₂.₅ (cyclone or impactor), PM₁₀ (inlet), Coarse PM (PM₁₀–PM₂.₅ via virtual impactor in 2000i-D) |
| Interface | RS-232, USB, Ethernet |
| Software | iPort™ Communications Suite, Activol™ Flow Management System |
| Safety Certification | CE EN 61326 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 2000i-D / 2000i |
| Typical Configuration | EPA Reference/Equivalent Method PM₂.₅ and Coarse PM Sampler |
| Flow Control | Mass Flow Controller (MFC) |
| Fine Particle Flow Rate | 15 L/min |
| Coarse Particle Flow Rate | 1.67 L/min |
| Filter Format | Dual 47 mm membrane holders |
| Data Logging Interval | 5 min |
| Internal Memory Capacity | 86 days @ 5-min intervals + 32 filter records |
| Communication Interfaces | RS-232, USB, Enhanced Ethernet (iPort™) |
| Operating Temperature Range | −40 °C to +50 °C |
| Compliance | U.S. EPA Reference Method for PM₂.₅ (40 CFR Part 53), Equivalent Method for PM₁₀ and Coarse PM (PM₁₀–PM₂.₅), ASTM D6216, ISO 7708 |