ACST
Filter
Showing all 3 results
| Brand | ACST |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACST-AFM |
| Instrument Type | Biological AFM |
| Position Detection Noise | ≤0.15 nm RMS |
| Maximum Sample Size | 15 mm diameter |
| XY Stage Travel Range | 25 mm × 25 mm |
| Software | Aotu AFM |
| Imaging Modes | Contact, Tapping, Phase, Lateral Force, Advanced Force Spectroscopy, Conductive AFM, Magnetic AFM, Nanolithography |
| XY Scanner Range | >50 µm (closed-loop), <10 nm resolution (closed-loop), <1 nm resolution (open-loop) |
| Z Scanner Range | >16 µm |
| Z Sensor Noise | <5 nm |
| Z Feedback Noise | <0.2 nm |
| Z Actuation | Direct-drive stepper motor, 25 mm travel, 330 nm minimum step, 8 mm/min max speed |
| Optical System | 3 MP CCD camera, 45×–400× real-time magnification |
| Base Material | Solid granite for vibration isolation and mechanical stability |
| Probe Loading | Tool-free, rapid exchange design |
| Brand | ACST |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | NanoFab |
| Price | USD 200,000 |
| Instrument Category | Microarray Fabrication System |
| Substrate Material | Silicon |
| Substrate Dimensions | 2 cm × 2 cm |
| Feature Size | 5 µm |
| Probe Anchoring Method | Atomic Stamp (Soft Lithography-Based) |
| Compatible Sample Types | Nucleic Acids, Proteins |
| Brand | ACST |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | NLP-2000 |
| Price | USD 200,000 |
| Instrument Type | Microarray Chip System |
| Footprint | 4 cm × 4 cm × ~18 cm (H) |
| Substrate Compatibility | Silicon, SiO₂, Silanized Glass, Amine-Activated Slides, Metals, PDMS, Hydrogels, Polystyrene, Catalysts, Thiols |
| Minimum Feature Size | 10 nm |
| Patterning Method | Direct-Write Dip-Pen Nanolithography (DPN) |
| Printable Materials | Proteins, DNA/RNA, Antigens, Liposomes, Nanoparticles, Polyethylene Glycol (PEG), UV-Curable Polymers, Thermoset Polymers, Glycerol, Silanes |
| Viscosity Range | 1–20,000 cP |
| Print Area | 40 mm × 40 mm |
| Resolution | Sub-100 nm lateral, <5 nm height control |
| Probe Array Configurations | Single-tip to M-type multi-tip (up to 128 tips) |
| Environmental Control | Integrated Humidity & Temperature Chamber (±0.1 °C, ±2% RH) |
| Motion Stages | Piezoelectric XYZ linear stages + dual-axis goniometer (Tx/Ty) |
| Imaging | High-resolution optical microscope (10×–100×, 0.7 µm resolution) |
| Software | ACST NanoPattern Suite v4.2 (Scriptable, GLP-compliant audit trail, FDA 21 CFR Part 11 optional) |