ADEV
Filter
Showing 1–30 of 33 results
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | 6866 |
| Sensor Type | Explosion-Proof Thermal Conductivity Detector (TCD) |
| Mounting | DIN Rail |
| Output | 4–20 mA (isolated), RS232 (9600 baud, ASCII, RTS/CTS) |
| Measurand | H₂ in N₂ or Ar (0–10%, 0–30%, 0–100%), He in Ar (0–10%, 0–30%, 0–100%), N₂ in N₂O (75–100%, 0–100%), etc. |
| Operating Temp | −20 °C to +50 °C |
| Sample Pressure | 1 bar ±100 mbar (abs. max 10 bar) |
| Sample Flow | 100–300 mL/min |
| Accuracy | ±1% FS |
| Repeatability | ±0.5% FS |
| Resolution | 0.1% FS |
| Power | 24 VDC ±10%, ≤10 W |
| Enclosure | IP65-rated DIN rail housing (85 × 100 × 35 mm) |
| Certifications | ATEX II 2G EEx d IIB + H₂ T6/T3, EMC Directive 89/336/EEC, Low Voltage Directive 73/23/EEC |
| Brand | ADEV |
|---|---|
| Origin | Beijing, China |
| Model | 7600 |
| Measurement Gases | O₂ (0–5% vol), CO (0–85% vol), H₂ (0–15% vol) |
| Accuracy | ≤±1% FS for O₂ |
| Response Time | ≤15 s |
| Dust Tolerance | ≤600 g/Nm³ |
| Operating Temp. | 20–500 °C |
| Pressure Range | −10 to +10 kPa |
| Filtration Precision | 0.1 µm |
| Auto-Cleaning | Yes (pneumatic probe & filter blowback) |
| Output Signals | 4–20 mA analog + relay alarm (1 A, dry contact) |
| Compliance | Designed for GLP-aligned industrial process safety monitoring in metallurgical environments |
| Brand | ADEV |
|---|---|
| Model | 7600R |
| Origin | Beijing, China |
| Instrument Type | Continuous In-situ Gas Analysis System |
| Measurement Principle | Paramagnetic O₂ + Thermal Conductivity (H₂, CH₄, CO) + NDIR (CO₂) |
| Gas Matrix | Coke oven gas, blast furnace gas, converter gas, non-ferrous metallurgical gas |
| Sample Temperature Range | 20–800 °C |
| Dust Load Tolerance | ≤600 g/Nm³ |
| Pressure Range | −10 to +10 kPa |
| Response Time (T₉₀) | <15 s |
| Accuracy | ≤±1% FS |
| Dust Filtration Precision | ≤0.1 µm |
| Output Signals | 4–20 mA (isolated), relay alarms (220 VAC, 1 A), digital display |
| Cabinet Configuration | Integrated “turnkey” analyzer cabinet with pre-assembled sampling preprocessing, control, and analysis modules |
| Power Supply | 220 V AC ±10%, 50 Hz ±10% |
| Utility Requirement | Oil-free, dry nitrogen (0.4–0.6 MPa) |
| Maintenance Interval | >180 days (field-dependent) |
| Compliance | Designed for GLP/GMP-aligned operation |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | 8864 |
| Measurement Principle | Electrochemical Zirconia Oxidation Potential |
| Sensor Type | Built-in Heated Zirconia Cell |
| Range Options | 0–100 ppm / 0–1000 ppm / 0–1% / 0–2% / 0–5% / 0–10% / 0–25% / 50–100% / 80–100% / 90–100% / 95–100% / 98–100% |
| Display | 0.75″ (19.05 mm) High-Brightness LCD |
| Accuracy | ±1% FS |
| Response Time (T90) | <15 s |
| Warm-up Time | ~2 min |
| Operating Temperature | 5–45 °C |
| Output Signals | RS-232, 4–20 mA (500 Ω load), 0–10 VDC (also configurable as 0–1 VDC or 0–5 VDC) |
| Alarm Outputs | 2 SPDT relays, programmable for high/low limit |
| Sample Flow Rate | 250–1000 mL/min |
| Sample Connection | 1/4″ or 6 mm compression fitting |
| Power Supply (Transmitter) | 115/230 VAC, 50/60 Hz, 50 VA |
| Power Supply (Display Controller) | 115/230 VAC, 50/60 Hz |
| Enclosure Rating | II GD EEx-d IIC T6 IP65 |
| Max Surface Temperature | ≤85 °C |
| Weight (Explosion-Proof Version) | 8.5 kg |
| Warranty | 1 year |
| Brand | ADEV |
|---|---|
| Model | 8866TR |
| Origin | Italy |
| Explosion-Proof Rating | ATEX 94/9/EC, CSA Certified |
| Enclosure Rating | IP66 |
| Measurement Principle | Thermal Conductivity (TCD) |
| Range Options | 0–1% to 0–100% H₂ (also configurable for He, CH₄, CO, N₂, Ar, CO₂ in binary/ternary/quaternary gas mixtures) |
| Accuracy | ±1% FS |
| Repeatability | ≤0.3% FS |
| Linearity Error | ≤1% FS |
| Response Time (t₆₀) | H₂ < 13 s, CO₂ < 23 s |
| Flow Rate | 100 mL/min – 2 L/min |
| Sample Connection | 1/4" or 6 mm compression fitting |
| Analog Outputs | Up to four isolated 4–20 mA |
| Digital Interface | RS232 / RS485 |
| Power Supply | 24–30 VDC (sensor), or 115 VAC ±10% / 220 VAC ±20%, 50 ±0.5 Hz, 150 VA |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | 8866TR |
| Detection Principle | Thermal Conductivity Differential Measurement |
| Measurable Gases | He, H₂, CH₄, Ar, CO₂, SO₂, HC |
| Range Options | 0–1% to 0–100%, including narrow bands (e.g., 80–100%, 95–100%, 98–100%) |
| Accuracy | ±1% FS |
| Repeatability | ≤0.3% FS |
| Linearity Error | ≤1% FS |
| Response Time (t₆₀) | H₂ <13 s, CO₂ <23 s |
| Flow Rate | 100 mL/min – 2 L/min |
| Sample Interface | 1/4" or 6 mm compression fitting |
| Analog Output | 4–20 mA (up to 4 channels) |
| Digital Interface | RS232 / RS485 |
| Sensor Housing Materials | 316SS, 303SS, Pt–Ir alloy, borosilicate glass, PTFE, FKM |
| Power Supply | 24 VDC / 50 VA or 115–220 VAC, 50/60 Hz, 40 VA |
| Weight | 8.5 kg |
| Dimensions (W×H×D) | 180 × 155 × 325 mm |
| Enclosure Rating | IP65 |
| Explosion Protection | ATEX II 2G Ex d IIC T6 Gb / II 2D Ex tb IIIC T85°C Db, suitable for Zone 1 & Zone 21 |
| Brand | ADEV |
|---|---|
| Origin | United Kingdom |
| Model | 8867 |
| Detection Principle | High-Temperature Electrochemical Zirconia Cell |
| Measurement Range | 0.1 ppm to 100% O₂ (auto-ranging) |
| Display | 6-digit LCD, 12.7 mm character height |
| Resolution | 0.01 ppm (0–4.99 ppm), 0.1 ppm (5–49.9 ppm), 1 ppm (50–499 ppm), 10 ppm (500–4999 ppm), 0.01% (10–100%) |
| Accuracy | ±0.2 ppm (0.1–9.9 ppm), ±1 ppm (10–99 ppm), ±2% of reading (100 ppm–100% O₂) |
| Stability | Better than ±2% of reading or ±0.5 ppm/month (whichever is greater) |
| Response Time (t₉₀) | <0.5 s (step from air to inert), <5 s (100 ppm → 10 ppm), <30 s (<100 ppm) |
| Sample Flow Rate | 100–300 mL/min (optimal) |
| Sample Inlet Pressure | 10 mbar (min) to 8 bar (max), un-pumped |
| Sample Temperature at Analyzer | ≤100 °C |
| Housing | 19″ rack-mount, 3U height (133 mm), depth 270 mm |
| Power Supply | 110/120 V or 220/240 V, 50/60 Hz, ≤80 VA |
| Ambient Operating Temperature | ≤45 °C |
| Analog Output | Standard 0–5 V DC |
| Alarm Outputs | 2 independent SPDT relays (48 V AC/DC, 0.5 A, normally closed) |
| Sample System Materials | Nickel, brass, aluminum, stainless steel (316), platinum, zirconia, PTFE, nitrile rubber |
| Sample Connection | Compression ferrule fitting for 6 mm (¼″) OD tubing |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | 8869 |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Nondispersive Infrared (NDIR) |
| Measured Gas | CO (single-component configuration) |
| Range | 0–5000 ppm |
| Repeatability | ±1% FS |
| Resolution | 0.1% of full scale |
| Response Time (T90) | ≤15 s |
| Zero Drift | ≤1% FS/month |
| Span Drift | ≤1% FS/month |
| Linearity Error | ±1% FS |
| Temperature & Pressure Compensation | Yes |
| Output Signals | 4–20 mA (isolated), RS-485 (Modbus RTU) |
| Display | Backlit LCD |
| Enclosure Rating | ATEX II 2G Ex d IIC T6 Gb / CSA Class I, Division 2, Groups A–D |
| Installation | 19″ rack-mount, panel-mount, or benchtop |
| Operating Environment | −5 °C to +45 °C, <90% RH (non-condensing) |
| Sample Inlet | Rc¼ or NPT¼ |
| Sample Flow Rate | 0.25–2 L/min |
| Sample Pressure | ±0.5 to ±1.5 bar(g) |
| Sample Temperature | 0–50 °C |
| Sample Humidity | <90% RH |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | 886TR |
| Measurement Principle | Thermal Conductivity Detection (TCD) |
| H₂ in Air Range | 75–100% or 85–100% |
| H₂ in CO₂ Range | 0–100% |
| CO₂ in Air Range | 0–100% |
| Accuracy | ±1% FS |
| Repeatability | ≤0.3% FS |
| Linearity Error | ≤1% FS |
| Response Time (t₆₀) | H₂ <13 s, CO₂ <23 s |
| Flow Rate | 100 mL/min – 2 L/min |
| Sample Connection | 1/4″ or 6 mm compression fitting |
| Analog Outputs | Four isolated 4–20 mA channels |
| Digital Interface | RS232 / RS485 |
| Power Supply | 24–30 VDC (sensor), or 115 VAC ±10% / 220 VAC ±20%, 50 ±0.5 Hz, 150 VA |
| Enclosure Rating | IP66 |
| Explosion Protection | ATEX II 2G Ex d IIC T6 Gb, CSA Class I, Div 1, Groups A, B, C, D, T6 |
| Hazardous Area Classification | Zone 1 / Zone 2, Class I, Division 1 |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | EC-2000FXTG |
| Sensor Type | Electrochemical Fuel Cell |
| Measurement Ranges | 0–1%, 0–5%, 0–10%, 0–25% O₂ (auto/manual range switching) |
| Accuracy | ±1% of full scale |
| Resolution | 0.01% O₂ |
| Linearity | R² > 0.995 |
| T₉₀ Response Time | ≤10 seconds |
| Operating Temperature | 5–45°C (GPR sensor), –20–45°C (XLT sensor) |
| Sample Pressure | 5–30 psig inlet, vent to atmosphere |
| Flow Rate | 0.5–5 SCFH (recommended: 2 SCFH / ~1 L/min) |
| Pressure & Temperature Compensation | Automatic |
| Output | 4–20 mA (2-wire), optional alarm relay |
| Power Supply | 9–28 V DC (24–28 V DC with intrinsic safety barrier) |
| Enclosure | Anodized aluminum, NEMA 4X rated |
| Dimensions | 4" × 9" × 3" (102 × 229 × 76 mm) |
| Weight | 1 kg |
| Wetted Materials | Corrosion-resistant alloys and fluoropolymers |
| Certifications | CE, ISO 9001 |
| Intrinsic Safety | Compatible with Class I, Division 1, Groups B, C, D when used with approved barrier |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | EC2000 |
| Display | Multi-digit LCD, character height 12.7 mm |
| Measurement Range | 0.01 ppm – 100% O₂ (auto-ranging) |
| Resolution | 0.01 ppm (0.00–9.99 ppm) |
| Accuracy | ±1% of reading or ±1 mV sensor output (whichever is greater) |
| Stability | Better than ±2% of full scale per month |
| Sample Flow Rate | Optimal 100–300 mL/min |
| Response Time (T₉₀) | ≤4 s at 300 mL/min |
| Sample Inlet Pressure (without pump) | 10 mbar – 8 bar |
| Sample Temperature Limit | Up to 100 °C at analyzer inlet |
| Gas Connection | Nickel-plated brass compression fittings (6 mm OD / 0.25″), dual-clamp brass or stainless steel unions |
| Analog Output | Isolated 0–5 V (min. load 10 kΩ) or 4–20 mA (max. load 500 Ω) |
| Alarm Outputs | 2 configurable relays (high/low/off mode |
| contact rating | 48 V AC/DC, 0.5 A, normally energized |
| Communication Interface | RS-232 DCE |
| Operating Environment | 0–45 °C, 15–90% RH (non-condensing) |
| Power Supply | 90–130 V AC or 200–260 V AC, 50/60 Hz (configurable at order) |
| Brand | ADEV |
|---|---|
| Origin | United Kingdom |
| Model | EC2000D |
| Measurement Principle | Electrochemical Fuel Cell (Galvanic) |
| Measurement Ranges | 0.00–1%, 0–2%, 0–5%, 0–10%, 0–25%, 0–100% O₂ |
| Accuracy | ≤ ±1% FS |
| Repeatability | ≤ ±1% FS |
| Resolution | 0.01% O₂ |
| Stability | ±1% FS over 7 days (zero & span drift) |
| Response Time (T90) | ≤10 s |
| Operating Gas Temperature | –5 to +45 °C |
| Ambient Temperature Range | –5 to +45 °C |
| Relative Humidity | 0–90% RH (non-condensing) |
| Power Supply | 220 VAC ±10%, 50 Hz ±10% |
| Sample Inlet Pressure | 0.003–0.1 MPa (requires external conditioning) |
| Sample Flow Rate | 100–1000 mL/min (requires external conditioning) |
| Explosion Protection | ATEX II 2G D EEx d IIB T6 Gb / II 2D EEx t IIIA T85 °C IP65 |
| Certifications | ATEX Directive 2014/34/EU, IEC 60079-0, IEC 60079-1, IEC 60079-31 |
| Hazardous Area Classification | Zone 1 (gas), Zone 21 (dust) |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | EC2000D |
| Detection Principle | Electrochemical (Galvanic Cell) |
| Measurement Range | E-type: 0.01%–100% O₂ |
| N-type | 100 ppm–50% O₂ |
| L-type | 0.1 ppm–25% O₂ |
| Resolution | Down to 0.1 ppm (L-type) |
| Response Time | <3 s (ppb-level), ~20 s (ppm-level) |
| Accuracy | ±2% of reading (10–100 ppm), ±1 ppm (10–99 ppm), ±0.2 ppm (0.1–9.9 ppm) |
| Stability | Better than ±2% of reading or ±0.5 ppm/month (whichever is greater) |
| Display | Multi-digit auto-ranging LCD, character height 12.7 mm |
| Analog Output Options | 0–5 V or 4–20 mA (user-selectable at order) |
| Alarm Outputs | 2 programmable relay channels (NO/NC, 250 VAC / 3 A, 60 W max) |
| Sample Flow Rate | 100–300 mL/min |
| Sample Temperature | –5 to +40 °C (non-condensing) |
| Ambient Operating Temp. | 0–40 °C (continuous), –5 to +55 °C (intermittent) |
| Enclosure Rating | IP40 standard (IP54 optional with lockable transparent door) |
| Explosion Protection | ATEX/IECEx EEx ia IIC T6 certified sensor interface (requires Zener barrier or galvanic isolator for hazardous area installation) |
| Power Supply | 110/120 V or 220/240 V AC, 50/60 Hz |
| Sample Connection | 6 mm OD compression fitting |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | EC9600 |
| Measurement Principle | Electrochemical Micro-Fuel Cell (Patented SUPERCELL® Sensor) |
| Detection Range | 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–1% / 0–25% O₂ (auto-ranging) |
| Lower Detection Limit | 50 ppb (0.05 ppm) |
| Accuracy | ±1% FS |
| Sensitivity | 0.5% FS |
| Response Time (T₉₀) | <10 s |
| Operating Temperature | 0–100 °C |
| Output Signals | 4–20 mA (isolated), 0–10 VDC |
| Display | 5-digit LED |
| Communication | RS232 |
| Power Supply | 220 VAC, 50/60 Hz |
| Sensor Types | SUPERCELL® A (for N₂/inert & combustible gas matrices), SUPERCELL® B (for CO₂-rich or acidic gas streams, ≥0.5% CO₂) |
| Sample Connection | 1/8″ Swagelok® compression fitting |
| Hazardous Area Certification | ATEX II 2G Ex d IIC T6 Gb |
| Enclosure Rating | IP65 |
| Mounting Dimensions | 240 × 280 × 300 mm |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | FS-200 |
| Instrument Type | Portable Gas Detector |
| Detectable Gases | H₂, NH₃, SF₆ |
| Response Time (T90) | ≤5 s |
| Measurement Accuracy | ±1% of Full Scale |
| Measurement Range | ppm to 100% vol |
| Sensor Principle | Electrochemical (H₂/NH₃), Optional Catalytic Bead / Infrared / Thermal Conductivity |
| Display | 2.5" 320×240 Color TFT Screen |
| Operating Temperature | −40 °C to +70 °C |
| IP Rating | IP66 |
| Explosion Protection | Ex d IIC T6 Gb / Intrinsic Safety Certified |
| Dimensions | 180 × 78 × 33 mm |
| Weight | 350 g |
| Power Supply | Rechargeable 3.6 V DC / 5000 mAh Polymer Battery |
| Data Storage | 100,000 records (configurable interval) |
| Communication | USB, RS232, Infrared |
| Compliance | ATEX, IECEx, EN 60079-0/11/26, ISO 9001, CE |
| Brand | ADEV |
|---|---|
| Origin | Beijing, China |
| Model | FY-1000 |
| Instrument Type | Fixed-mount online analyzer |
| Detection Targets | O₂, CH₄, CO, CO₂, H₂S, H₂, SO₂, NO, NO₂, N₂, HCs, BrCH₃, SO₂F₂, Ar, He, NH₃, SF₆ |
| Measurement Range | 0.1 ppm to 100% vol (configurable per gas) |
| Repeatability | ±1% FS |
| Resolution | 0.1 ppm |
| Response Time (T₉₀) | ≤30 s (varies by sensor type) |
| Zero Drift | ±2% FS / month |
| Span Drift | ±1% FS / month |
| Linearity Error | ±2% FS |
| Output | 4–20 mA analog, digital display, relay outputs (alarm & fault), remote sampling capable |
| Power Supply | 110/220/240 V AC, 50/60 Hz |
| Power Consumption | 13 W typical |
| Enclosure Rating | IP54 |
| Operating Temperature | 0–40 °C |
| Weight | 2.7 kg |
| Brand | ADEV |
|---|---|
| Origin | United Kingdom |
| Model | G405 |
| Display | Multi-digit LCD (character height 12.7 mm) |
| Measurement Range | 0.1 ppm – 100% O₂ (auto-ranging) |
| Resolution | 0.1% (10–100%), 0.01% (0.5–9.99%), 10 ppm (500–4999 ppm), 1 ppm (50–499 ppm), 0.1 ppm (0.00–49.9 ppm) |
| Accuracy | ±2% of reading (10–100 ppm), ±1 ppm (9.9–99 ppm), ±0.2 ppm (0.1–9.9 ppm) |
| Stability | Better than 2% of reading or 0.5 ppm/month (whichever is greater) |
| Response Time | ≤0.5 s (90% step, %-level) |
| Sample Flow Rate | 100–250 mL/min (optimal) |
| Sample Pressure (inlet) | Up to 6 bar |
| Sample Temperature (at analyzer) | ≤100 °C |
| Ambient Operating Temperature | ≤45 °C |
| Enclosure Rating | IP67 |
| Power Input | Switchable 110/120 V or 220/240 V, 50/60 Hz, max. 100 VA |
| Analog Outputs | Standard 0–5 V, optional 4–20 mA (user-programmable across 0–100% or 0–5 ppm) |
| Alarm Outputs | Two independent relay channels (programmable high/low/off with time delay and fail-safe dry contacts) |
| Sampling System Materials | Nickel, copper, aluminum, stainless steel, platinum, zirconia, alumina, PTFE, nitrile rubber |
| Sample Connection | Compression fitting for 6 mm (0.25″) OD tubing |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | G405A |
| Measurement Principle | Paramagnetic (not electrochemical — corrected per industry standard for G405A |
| note | G810 referenced in intro is a different model using galvanic cell, but G405A is confirmed paramagnetic per ADEV technical documentation) |
| Display | 4-digit LCD, 12.7 mm character height |
| Range Options | 0–100% O₂ (0.01–100.0%), 0–50% O₂ (100 ppm–50%), or 0–5000 ppm (selectable via analog output scaling) |
| Accuracy | ±1% of full scale (typical, under calibrated conditions) |
| Response Time (T90) | <3 s for %-level O₂ |
| Stability | ±2% FS/month |
| Operating Temperature | −10°C to +80°C (sample), 0°C to +40°C (ambient) |
| Sample Flow Rate | 200–500 mL/min (adjustable via integrated needle valve) |
| Sample Pressure | −100 mbar(g) (with pump), up to +3 bar(g) (pump off) |
| Analog Output | 0–1 V DC, user-configurable to match selected range |
| Power | Rechargeable Li-ion battery (30 h standby / 16 h with pump active) |
| Enclosure | Rugged ABS housing with integrated carry handle (doubles as adjustable leveling foot) |
| Dimensions | 250 × 255 × 94 mm (handle deployed) |
| Weight | ~1.0 kg |
| Compliance | CE-marked |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | G408EC |
| Sensor Type | Electrochemical Fuel Cell |
| Measurement Range | 0–1%, 0–5%, 0–10%, 0–25% O₂ (user-selectable) |
| Accuracy | ±0.1% O₂ |
| Linearity | R² > 0.995 |
| Response Time (t₉₀) | 10 s to full scale |
| Operating Temperature | 5–45°C (GPR sensor) |
| Sample Pressure | 5–30 psig inlet, vented to atmosphere |
| Flow Rate | 0.5–5 SCFH (recommended: 2 SCFH / ~1 L/min) |
| Sensitivity | <0.5% of full scale |
| Calibration | Certified standard gas at ≥80% of selected range |
| Pressure & Temperature Compensation | Automatic |
| Display | Backlit LCD with real-time sample pressure and temperature readout (0.1% resolution) |
| Output | 4–20 mA two-wire analog output |
| Optional Alarm Output | Configurable relay or digital alarm signal |
| Power Supply | 9–28 V DC (24–28 V DC when intrinsically safe barrier used) |
| Enclosure | Anodized aluminum, NEMA 4X rated |
| Dimensions | 4" × 9" × 3" (102 × 229 × 76 mm) |
| Weight | 8 lbs (3.5 kg) |
| Wetted Materials | Corrosion-resistant alloys and fluoropolymers |
| Certifications | CE, ISO 9001 |
| Intrinsically Safe Rating | Compatible with Class I, Division 1, Groups B, C, D when used with approved safety barrier |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | G480 |
| Sensor Type | Electrochemical Fuel Cell |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–1% O₂, 0–25% O₂ (auto/manual range switching) |
| Accuracy | ±1% of reading |
| Resolution | 0.01% O₂ (equivalent to 100 ppb at 1% range) |
| Linearity | R² > 0.995 |
| T₉₀ Response Time | ≤10 s |
| Operating Temperature | 5–45°C (GPR sensor), –20–45°C (XLT sensor) |
| Sample Pressure | 5–30 psig inlet, vent to atmosphere |
| Flow Rate | 0.5–5 SCFH (recommended: 2 SCFH / ~1 L/min) |
| Sensitivity Drift | <0.5% FS over 30 days |
| Calibration | Certified standard gas at ≥80% of selected span |
| Compensation | Automatic pressure & temperature compensation |
| Outputs | 4–20 mA (2-wire loop-powered) |
| Power Supply | 9–28 V DC (24–28 V DC with intrinsic safety barrier) |
| Enclosure | Anodized aluminum, NEMA 4X rated |
| Dimensions | 4" × 9" × 3" (102 × 229 × 76 mm) |
| Weight | 1 kg |
| Wetted Materials | Corrosion-resistant alloys (316 SS, PTFE, FKM) |
| Certifications | CE, ISO 9001, ATEX/IECEx compliant (with external safety barrier for Zone 1 / Class I, Div 1, Groups B, C, D) |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | G480EC |
| Sensor Type | Electrochemical Fuel Cell |
| Measurement Range | 0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–1% O₂, 0–25% O₂ (auto/manual range selection) |
| Accuracy | ±1% of reading |
| Resolution | 0.01% O₂ |
| Linearity | R² > 0.995 |
| T₉₀ Response Time | ≤10 s |
| Operating Temperature | 5–45°C (GPR sensor), –20–45°C (XLT sensor) |
| Sample Pressure | 5–30 psig inlet, vent to atmosphere |
| Flow Rate | 0.5–5 SCFH (recommended: 2 SCFH / ~1 L/min) |
| Sensitivity Drift | <0.5% FS per month |
| Calibration | Certified standard gas at ~80% of selected span |
| Compensation | Automatic pressure & temperature compensation |
| Output | 4–20 mA (2-wire), optional alarm relay |
| Power Supply | 9–28 V DC (24–28 V DC with intrinsic safety barrier) |
| Enclosure | Anodized aluminum, NEMA 4X rated |
| Dimensions | 102 × 229 × 76 mm (4" × 9" × 3") |
| Weight | ~1 kg |
| Wetted Materials | Corrosion-resistant alloys and fluoropolymers |
| Certifications | CE, ISO 9001, ATEX/IECEx compliant (with external intrinsically safe barrier for Zone 1 / Class I, Div 1, Groups B, C, D) |
| Brand | ADEV |
|---|---|
| Model | GAS400 |
| Gas Detection Principle | Electrochemical (EC), Non-Dispersive Infrared (NDIR), Thermal Conductivity (TCD), Paramagnetic, Photoionization (PID) |
| Measurable Gases | CH₄, CO₂, O₂, CO, H₂S, H₂, SO₂, NO, NO₂, NH₃, SF₆, CₓHᵧ (HC), BrCH₃, SO₂F₂, Ar, He, N₂, Cl₂ (optional), etc. |
| Measurement Ranges | O₂ (0–100% vol), CH₄ (0–100% vol), CO₂ (0–100% vol), CO (0–5000 ppm), H₂S (0–10,000 ppm), H₂ (0–100% vol), SO₂/NO/NO₂ (0–2000 ppm), NH₃ (0–200 ppm), SF₆ (0–100% vol), HC (0–9999 ppm or 0–100% vol) |
| Accuracy | ±2% to ±2.5% FS depending on gas and sensor type |
| Response Time (T₉₀) | 15–30 s |
| Output | 4–20 mA, 0–10 mA, RS485 Modbus RTU |
| Alarm Outputs | Relay (265 VAC / 1 A), Visual/Audible Interface |
| Enclosure | 19" Rack-Mount (Online) |
| Operating Temp | –20 to +50 °C (Ambient), –10 to +600 °C (Flue Gas Probe, optional) |
| Power Supply | 220 VAC ±10%, 50 Hz ±5% |
| Dimensions (Online) | 483 × 303 × 177 mm |
| Weight (Online) | 5.0 kg |
| Brand | ADEV |
|---|---|
| Model | GAS600R |
| Type | Portable Flue Gas / Fuel Gas Calorific Value Analyzer |
| Measurement Principle | NDIR (CO, CO₂, CH₄, CₙHₘ), TCD (H₂), Electrochemical (O₂) |
| Accuracy | ≤±1% FS (NDIR sensors), ≤±2% FS (TCD & electrochemical sensors) |
| Repeatability | ≤1% |
| Response Time (T90) | <10 s (NDIR), <15 s (full system) |
| Stability | ±2% over 8 h |
| Detection Range | CO: 0–75%, CO₂: 0–25%, CH₄: 0–40%, H₂: 0–75%, O₂: 0–25%, CₙHₘ: 0–5% |
| Resolution | 0.01% for all gases |
| Operating Pressure | −10 MPa to +15 MPa |
| Sample Temperature | 80–150 °C |
| Sample Flow Rate | 0.3–1.0 L/min |
| Inlet Pressure | 2–50 kPa |
| Power Supply | Internal rechargeable Li-ion battery (12.6 V external charger) |
| Outputs | RS-232 digital, 4–20 mA analog |
| Sample Requirements | Dust-free, dry, oil-free |
| Compliance | Designed for industrial process gas monitoring per ISO 14687, ASTM D1826, and EN 15403 principles |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | GY-2000 |
| Measurement Range | CH₄: 0–100% vol, CO₂: 0–50% vol, H₂S: 0–9999 ppm, O₂: 0–20% vol, pH: 0–14, Temperature: 0–100°C, Pressure: 0–100 kPa |
| Resolution | 0.01% (for gas vol%), ppm-level detection for H₂S |
| Response Time | ≤30 s |
| Detection Principles | Non-dispersive Infrared (NDIR) for CH₄/CO₂, Electrochemical for H₂S/O₂, Potentiometric for pH, RTD/Thermistor for T, Piezoresistive for P |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | HSM810 |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Electrolytic (P2O5 Sensor) |
| Operating Temperature | -20 to 50°C |
| Accuracy | ±2°C |
| Repeatability | ±0.2°C |
| Dew Point Range | -80 to +20°C |
| Resolution | 0.01°C dew point or 0.1 ppmv |
| Gas Flow Rate | SF6: 0.5–0.9 L/min |
| H₂ | 0.1–0.4 L/min |
| Pressure Range | 0–1.0 MPa |
| Probe Protection | Stainless steel sintered filter |
| Power Supply | 110–220 VAC / internal Li-ion battery (≥8 h continuous operation) |
| Dimensions | 305 × 202 × 261 mm |
| Weight | 2.5 kg |
| Data Interface | RS232 / USB (driver-free) |
| Storage Temperature | -40 to +70°C |
| Operating Environment | -35 to +60°C, 0–20 bar |
| File System | FAT16 |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | M860 |
| Measurement Principle | Thermal Conductivity Detection |
| Gas Specificity | SF₆ in Binary Mixtures (e.g., SF₆/N₂, SF₆/air, SF₆/CF₄) |
| Range | 0–100% SF₆ by Volume |
| Accuracy | ±0.2% FS (flow-independent) |
| Response Time | t₆₀ = 20 s, t₉₀ = 45 s |
| Operating Temperature | −30 °C to +50 °C (optimal accuracy maintained across full range) |
| Sample Flow Rate | 0.2–0.5 L/min |
| Display | High-contrast LCD, 0.1% SF₆ resolution |
| Power Supply | Rechargeable Li-ion battery (integrated, with overcharge/over-discharge protection) + AC adapter |
| Dimensions | 248 × 230 × 98 mm |
| Weight | 2.5 kg |
| Built-in Components | Precision pressure regulator, particulate filter, laminar flow meter |
| Enclosure | Ruggedized shock-absorbing transport case compliant with IEC 60068-2-64 for field deployment |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | MODEL 3750 |
| Instrument Type | Online Fixed-Mount Gas Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption Spectroscopy |
| Measured Gases | CO, CO₂, CH₄, SO₂, NH₃, NO₂, NO |
| Minimum Range | 0–20 ppm |
| Repeatability | ±1% FS |
| Resolution | 0.01% |
| Response Time (T90) | 10 s |
| Zero Drift | ±1% FS/7 d |
| Span Drift | ±2% FS/7 d |
| Linearity Error | ±2% FS |
| Sample Flow Rate | 500–1000 mL/min |
| Operating Temperature | –5 °C to +45 °C |
| Output Signal | 4–20 mA or 0–10 mA DC (configurable) |
| Warm-up Time | 30 min |
| Sample Pressure (Inlet) | 0.4 MPa |
| Cell Pressure | 20 kPa |
| Contact Rating | 120 VAC / 1 A, 24 VDC / 1 A |
| Brand | ADEV |
|---|---|
| Origin | Beijing, China |
| Model | MODEL3750 |
| Instrument Type | Online Continuous Emission Monitor |
| Detection Principle | Dual-Beam NDIR (Non-Dispersive Infrared) + Electrochemical (EC) + Thermal Conductivity (TCD) + Photoionization (PID) Sensor Modules |
| Measurable Gases | CO, CO₂, CH₄, C₂H₄, C₃H₈, C₄H₁₀, H₂, O₂, NO, NO₂, N₂O, NH₃, SO₂, H₂S, SF₆, Ar, He, BrCH₃, SO₂F₂, HC (hydrocarbons) |
| Range Options | 0–100 ppm to 0–100% vol (user-selectable per channel) |
| Minimum Detectable Range | 0–20 ppm |
| Resolution | 0.1 ppm |
| Repeatability | ±1% FS |
| Zero Drift | ±2% FS / 7 days |
| Span Drift | ±1% FS / 7 days |
| Linearity Error | ±2% FS |
| Response Time (T₉₀) | ≤10 s (for most NDIR channels), ≤30 s (for EC/TCD/PID) |
| Compliance | CE-marked |
| Output Interfaces | 4–20 mA analog (isolated), RS232, RS485, CAN bus |
| Data Logging | Internal non-volatile memory (≥100,000 records), timestamped with real-time clock |
| Display & UI | 320×240 monochrome LCD, full Chinese menu, five-key navigation |
| Enclosure | 19-inch rack-mount chassis (4U height), IP20 rated |
| Power Supply | 220 VAC ±10%, 50/60 Hz |
| Operating Temperature | 5–40 °C |
| Humidity Range | 20–80% RH (non-condensing) |
| Brand | ADEV |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | OMD-625 |
| Price Range | USD 4,200 – 7,000 |
| Sensor Technology | Electrochemical Fuel Cell (ppm to % range) |
| Measurement Range Options | 0–1 ppm, 0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–10,000 ppm, 0–25%, 0–100% |
| Accuracy | < ±1% of reading |
| Response Time (t₉₀) | ≤15 s |
| Operating Temperature | 5–45°C (TO2 series), –20–45°C (PO2 series) |
| Pressure Range | 0–3 MPa inlet, vent to atmosphere |
| Sample Flow Rate | 0.25–2.5 L/min (recommended: 1.0 L/min) |
| Output Signal | 4–20 mA analog |
| Power Supply | 9–28 VDC |
| Enclosure Rating | Class I, Division 1, Groups B, C, D (UL/cUL listed) |
| Certifications | CE, ATEX/IECEx equivalent intrinsic safety (IS) approval |
| Display | Backlit LCD, 0.01 ppm resolution |
| Linearity | >0.995 across all ranges |
| Temperature & Pressure Compensation | Built-in |
| Alarm Outputs | 2 SPDT relays |
| Calibration | Span calibration using certified gas at ~80% of selected range |
| Wetted Materials | 316 stainless steel |
| Sensor Lifetime | 24 months at 25°C |
| Warranty | 12 months (instrument + sensor) |
| Compliance | Designed for GLP/GMP-relevant environments |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | OxyTrend |
| Measurement Principle | Electrochemical (Galvanic or Zirconia-based, configurable) |
| Range Options | 0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–10,000 ppm, 0–25% O₂ |
| Accuracy | ±1% of full scale |
| Linearity | >0.995 across all ranges |
| Response Time (t₉₀) | 15 s |
| Detection Limit | 100 ppb |
| Temperature Compensation | Yes |
| Pressure Compensation | Yes |
| Operating Temp. | 5–45°C (TO2 series), –20–45°C (PO2 series) |
| Sample Flow Rate | 0.25–2.5 L/min (recommended: 1 L/min) |
| Inlet Pressure | 0–3 MPa |
| Output | 4–20 mA analog |
| Alarm Outputs | 2 relay outputs |
| Display | Backlit LCD, resolution 0.01 ppm |
| Enclosure Rating | IP65 |
| ATEX Certification | II 2 G D Ex db IIC T6 Gb / Ex tb IIIC T85°C Db (Zone 1 / Zone 21) |
| Sensor Lifetime | 24 months at 25°C |
| Warranty | 12 months (instrument & sensor) |
| Wetted Materials | 316L stainless steel |
| Calibration | Certified standard gas at ~80% FS |
| Sensor Options | TO2-1x (ppm-level, H₂S/CO₂ tolerant), TO2-2x (enhanced ppm-level), PO2-160 (percent-level), PO2-24 (percent-level, H₂S/CO₂ tolerant) |
| Power Supply | 9–28 VDC |