Methane Non Methane Hydrocarbon Detector
Filter
Showing 1–30 of 61 results
| Brand | ADEV |
|---|---|
| Model | GAS400 |
| Gas Detection Principle | Electrochemical (EC), Non-Dispersive Infrared (NDIR), Thermal Conductivity (TCD), Paramagnetic, Photoionization (PID) |
| Measurable Gases | CH₄, CO₂, O₂, CO, H₂S, H₂, SO₂, NO, NO₂, NH₃, SF₆, CₓHᵧ (HC), BrCH₃, SO₂F₂, Ar, He, N₂, Cl₂ (optional), etc. |
| Measurement Ranges | O₂ (0–100% vol), CH₄ (0–100% vol), CO₂ (0–100% vol), CO (0–5000 ppm), H₂S (0–10,000 ppm), H₂ (0–100% vol), SO₂/NO/NO₂ (0–2000 ppm), NH₃ (0–200 ppm), SF₆ (0–100% vol), HC (0–9999 ppm or 0–100% vol) |
| Accuracy | ±2% to ±2.5% FS depending on gas and sensor type |
| Response Time (T₉₀) | 15–30 s |
| Output | 4–20 mA, 0–10 mA, RS485 Modbus RTU |
| Alarm Outputs | Relay (265 VAC / 1 A), Visual/Audible Interface |
| Enclosure | 19" Rack-Mount (Online) |
| Operating Temp | –20 to +50 °C (Ambient), –10 to +600 °C (Flue Gas Probe, optional) |
| Power Supply | 220 VAC ±10%, 50 Hz ±5% |
| Dimensions (Online) | 483 × 303 × 177 mm |
| Weight (Online) | 5.0 kg |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA LDS |
| Instrument Type | Portable |
| Sensitivity | CH₄ < 1 ppb/s, C₂H₆ < 500 ppt/s |
| Measurement Principle | Mid-Infrared Laser Absorption Spectroscopy |
| Path Length | 13 m in 60 mL sample cell |
| Detection Targets | CH₄, C₂H₆, H₂O (dry mole fraction reported) |
| Ethane/Methane Ratio Accuracy | ±0.02% (e.g., 4.42% ± 0.02%) |
| Drift (Ultra) | ≤2 ppb or 0.1% of reading across full temperature range |
| Operating Environment | 10–40 °C, 10–95% RH (non-condensing) |
| Data Output Rate | 1–2 Hz standard, up to 10 Hz optional |
| GPS Accuracy | High-precision embedded GNSS with magnetic-mount antenna |
| Power Consumption | 15–25 W depending on configuration |
| Dimensions & Weight | Pico (2.75 kg), Ultra Portable (6.5 kg), Strato (2.0 kg) |
| Data Storage | 32 GB internal (expandable) |
| Communication Interfaces | Wi-Fi, RS-232, USB, analog output (optional) |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | THB-8021 |
| Instrument Type | Portable |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Measurement Range | 1.0–50,000 ppm (as methane or propane equivalent) |
| Detection Limit | 0.5 ppm (FID, ethane |
| Repeatability | ±2% at 100 ppm methane (FID) |
| Accuracy | ±10% of reading or ±1.0 ppm (FID, whichever is greater) |
| Response Time (FID) | ≤3.5 s to 90% of final value (10,000 ppm CH₄) |
| Recovery Time (FID) | ≤4.5 s to within 10% of baseline (10,000 ppm CH₄) |
| Dynamic & Linear Range (FID) | 1.0–50,000 ppm |
| Detector Lifetime (FID) | >5,000 h (with routine maintenance) |
| Power Supply | Internal rechargeable battery (10 h operation, 4 h charge) |
| Dimensions | 219 × 260 × 70 mm |
| Weight | 4.1 kg |
| Operating Temperature | −10 to +50 °C |
| Data Output | USB (TXT format), Bluetooth, optional 4G/GPS |
| Intrinsic Safety | Certified for Class I, Division 1 hazardous areas (per IECEx/ATEX standards) |
| Compliance | Designed to support LDAR (Leak Detection and Repair) programs per US EPA Method 21, ASTM D6420, and ISO 16000-29 |
| Brand | API |
|---|---|
| Model | N901 |
| Detection Principle | Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Measured Parameters | Total Hydrocarbons (THC), Methane (CH₄), Non-Methane Hydrocarbons (NMHC) |
| NMHC Calculation Method | NMHC = THC − CH₄ |
| Detector Type | Flame Ionization Detector (FID) |
| Sample Inlet Filtration | Stainless Steel Sintered Filter |
| Control & Data Processing | Integrated NumaView™ Software (NVS), Standalone Operation |
| Compliance Context | Designed for EPA Method 25A, ASTM D6348, ISO 8573-5, and EU Directive 2008/50/EC ambient air monitoring requirements |
| Power Consumption | Low-power embedded architecture |
| Design Philosophy | Modular hardware, field-serviceable electronics, maintenance-minimized gas path |
| Brand | Asicotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | P5100-A6 |
| Instrument Type | Online Continuous Emission Monitoring System (CEMS) |
| Detection Limit | <10 ppb for NMHC |
| Compliance | HJ 1019–2019 “Technical Specification for Continuous Automatic Monitoring of Non-Methane Hydrocarbons in Ambient Air (Trial)” |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Type | Portable |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measured Gas | CH₄ |
| Measurement Range | 0–1000 ppm |
| Detection Limit | 1 ppm |
| Alarm Accuracy | ±(5 ppm + 2% of reading) |
| Resolution | 1 ppm |
| Response Time (T90) | <10 s |
| Measurement Cycle | 30 s |
| Data Upload Interval | 2 min |
| Communication | LoRaWAN / NB-IoT |
| IP Rating | IP66 |
| Operating Temperature | −20 °C to +60 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Operating Pressure | 86–106 kPa |
| Power Supply | Rechargeable Li-ion battery + optional solar panel |
| Max. Power Consumption | 2 W |
| Dimensions (L×W×H) | 186 mm × 144 mm × 417 mm |
| Weight | 6.5 kg |
| Service Life | ≥10 years |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Type | Portable |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Analyte | CH₄ |
| Measurement Range | 0–1000 ppm |
| Detection Limit | 1 ppm |
| Alarm Accuracy | ±(5 ppm + 2% of reading) |
| Resolution | 1 ppm |
| Response Time (T90) | <10 s |
| Measurement Cycle | 30 s |
| Data Upload Interval | 2 min |
| Communication | LoRaWAN / NB-IoT |
| IP Rating | IP66 |
| Operating Temperature | −20 °C to +60 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Operating Pressure | 86–106 kPa |
| Power Supply | Rechargeable Li-ion battery + optional solar panel |
| Max. Power Consumption | 2 W |
| Dimensions (L×W×H) | 186 mm × 144 mm × 417 mm |
| Weight | 6.5 kg |
| Service Life | ≥10 years |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Type | Portable |
| Model | CH4 |
| Resolution | 320 × 256 |
| Spectral Band | 3.2–3.5 µm |
| Temperature Range | −20 to 350 °C |
| Temperature Accuracy | ±1 °C (0–100 °C), ±2 °C (−20–0 °C), ±2% of reading (>100 °C) |
| Ingress Protection | IP54 |
| Explosion Protection | Ex ic nc op is IIC T4 Gc |
| Storage | 64 GB SD card |
| Connectivity | USB, HDMI, SD card slot, Wi-Fi |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-2502 |
| Instrument Type | Online |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Analyte | CH₄ |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±(5 ppm + 2% of reading) |
| Warm-up Time | <10 s |
| Operating Temperature | −20 °C to +60 °C |
| Relative Humidity | 0–98% RH (non-condensing) |
| Operating Pressure | 80–120 kPa |
| Supply Voltage | 3.2–5.5 VDC |
| Current Consumption | <100 mA (@25 °C, 3.3 V) |
| Communication Interface | TTL (3.3 V logic level) |
| Dimensions (L×W×H) | 278 × 97 × 84 mm |
| Storage Conditions | −40 °C to +85 °C, 0–98% RH (non-condensing) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000GHG |
| Instrument Type | Online Analyzer |
| Detection Principle | Micro-flow NDIR & Dual-beam NDIR (CO₂/CH₄/N₂O/CO), Electrochemical (O₂) |
| Measured Gases | CO₂, CH₄, N₂O, CO, O₂ |
| CH₄ Range | 0–1000 ppm, Resolution: 1 ppm |
| Repeatability | ≤ ±1% F.S. |
| Accuracy | ±1% F.S. (micro-flow NDIR), ±2% F.S. (dual-beam NDIR & ECD) |
| Response Time (T90) | < 25 s |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Power Supply | 100–240 VAC, max 300 W (heating), stable 100 W |
| Output | RS-485/RS-232, 4–20 mA |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3500 |
| Instrument Type | Online |
| Detection Principle | NDIR (CO, CO₂, CH₄, C₃H₈), Electrochemical (O₂, H₂S) |
| Measured Gases | CO, CO₂, CH₄, C₃H₈, O₂, H₂S |
| Measurement Range | CO/CO₂/CH₄/C₃H₈: (0–100)% vol |
| O₂ | (0–25)% vol |
| H₂S | (0–9999) ppm |
| Repeatability | ≤2% |
| Accuracy | ±1% FS (NDIR gases), ±2% FS (O₂/H₂S) |
| Response Time (T90) | <15 s (NDIR) |
| Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Display | LCD |
| Output | RS-485/RS-232, 4–20 mA, Ethernet |
| Power | AC 220 V, 50 Hz |
| Explosion Protection | Ex d II CT6 / Ex tb IIIC T80°C Db |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100-CH4 |
| Instrument Type | In-situ Online Analyzer |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measured Gases | CH₄, O₂, CO, CO₂, H₂S |
| CH₄ Range | 0–20 %VOL |
| O₂ Range | 0–5 %VOL (customizable to 0–100 %VOL) |
| CO Range | 0–100 %VOL |
| CO₂ Range | 0–100 %VOL |
| H₂S Range | 0–100 ppm / 0–5000 ppm |
| Accuracy | ≤ ±1 %FS |
| Repeatability | ≤ ±1 %FS |
| Zero/ Span Drift | ≤ ±1 %FS/7d |
| Resolution | 0.01 %VOL (CH₄) |
| Response Time (T90) | ≤ 4 s |
| Ambient Temp. | −20 to +60 °C |
| Power Supply | 24 V DC, 24 W |
| Enclosure Rating | Exd II CT6 |
| Output | 2 × 4–20 mA, 3 × Relay |
| Communication | RS485, RS232 |
| Purge Gas | Industrial N₂, 0.3–0.8 MPa |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Type | Portable UAV-Mounted Gas Analyzer |
| Detection Principle | Mid-Infrared Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Analyte | CH₄ |
| Measurement Range | Not specified (CH₄-specific) |
| Detection Limit | <100 ppb (CH₄), <15 ppb (C₂H₆) |
| Optical Path | Open-Path |
| Data Acquisition Rate | 10–20 Hz |
| Sensitivity | <100 ppb (CH₄) |
| Weight | <3 kg |
| Software Features | Leak event identification & quantification, deep learning–enabled pattern recognition |
| Enclosure Material | Corrosion-Resistant Alloy |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Type | Portable |
| Measured Species | CH₄, C₂H₆ |
| Optical Path Configuration | Sealed Absorption Cell |
| Detection Limit (CH₄) | <100 ppb |
| Detection Limit (C₂H₆) | <15 ppb |
| Data Acquisition Rate | 10–20 Hz |
| Included Accessories | GNSS Positioning System (BeiDou-compatible), Ultrasonic Anemometer |
| Compliance Context | Designed for field-deployable ambient air monitoring per EPA Method 21 principles and ISO 13864:2022 guidance on mobile gas leak detection |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Type | Portable |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measured Species | CH₄ |
| Methane Concentration Range | 0.01%–100% vol |
| Emission Flux Range | 0.01–13 kg/h |
| Measurement Accuracy | ±5% of reading |
| Sampling Flow Rate | up to 400 L/min |
| Battery Runtime | >8 h |
| Charging Time | 10 h |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | MS104K-C8H10 |
| Instrument Type | Portable Gas Detector |
| Detection Target | Xylene (C₈H₁₀) |
| Detection Principle | PID (Photoionization Detection), Catalytic Combustion, or Thermal Conductivity (selectable) |
| Detection Range | 0–10 ppm / 0–100 ppm (customizable) |
| Resolution | 0.01 ppm (0–100 ppm), 0.1 ppm (0–1000 ppm), 1 ppm (>1000 ppm) |
| Accuracy | ≤±3% FS |
| Response Time (T90) | ≤30 s |
| Recovery Time | ≤30 s |
| Display | 2.31″ 320×240 Color TFT Screen |
| Data Storage | 100,000 entries (real-time, timed, or alarm-triggered) |
| Power Supply | 3.7 V DC, 2100 mAh Rechargeable Polymer Battery |
| Operating Temp. | −40°C to +70°C |
| Humidity Range | 0–95% RH (non-condensing) |
| Temp. Measurement (optional) | −40°C to +70°C, ±0.5°C |
| Humidity Measurement (optional) | 0–100% RH, ±3% RH |
| Protection Rating | IP65 |
| Explosion-Proof Certification | Exia II CT4 Ga |
| Dimensions | 130 × 68 × 34 mm (L×W×H) |
| Weight | 200 g |
| Certifications | CMC (China Metrology Accreditation), GB Standard Compliance |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | MS104K-L-CxHy |
| Instrument Type | Portable |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 6080 EGAC |
| Pricing | Available Upon Request |
| Sampling Flow Rate | 0.5 m³/h or 1.0 m³/h (critical orifice) |
| User Interface | 15" Color XGA + PCAP Touchscreen |
| Data Communication | Ethernet TCP/IP, USB 2.0 |
| Relative Humidity Range | 10–80 % RH (non-condensing) |
| Operating Temperature | 20–30 °C |
| Power Supply | 220 ± 22 VAC, 50 ± 0.5 Hz |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GC6010 |
| Pricing | Available Upon Request |
| Measurement Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Analytes | Non-Methane Hydrocarbons (NMHC), Benzene-Toluene-Ethylbenzene-Xylenes (BTEX) |
| Column Configuration | One Packed Column + One Empty Column (for THC) + One Dedicated Packed Column (for BTEX) |
| Detector | Dual FID Units (Dedicated or Shared via Valve Switching) |
| Oven Temperature Control | 120 °C (BTEX), 150 °C (NMHC), ±0.5 °C Stability |
| Carrier Gas | Hydrocarbon-Free Air |
| Analysis Cycle | < 120 s (NMHC), < 180 s (BTEX) |
| Response Time (T90) | < 20 s |
| Signal Output | RS-232 / RS-485 (Modbus RTU) |
| Power Supply | 220 ± 22 VAC, 50 ± 0.5 Hz |
| Operating Ambient | 0–50 °C |
| Sample Line Heating | Full High-Temperature Zone (≥150 °C), No Cold Spots |
| Valving | 5-Position, 10-Port Rotary Valve with Patented Back-Flush Capability |
| Compliance | GB/T 39786–2021, HJ 1012–2018, HJ 1078–2019 |
| Brand | ETI |
|---|---|
| Model | IES-200 |
| Origin | Guangdong, China |
| Instrument Type | Continuous Ambient Air Monitoring System |
| Measured Parameters | SO₂, CO, NO₂, O₃, TVOC, PM₁.₀, PM₂.₅, PM₁₀ |
| Detection Principle | Electrochemical (SO₂/CO/NO₂/O₃), PID (TVOC), Laser Scattering (PM) |
| Range | SO₂ 0–2 ppm |
| Resolution | SO₂ 0.05 ppm |
| Response Time (t₉₀) | SO₂/CO/NO₂/O₃ ≤90 s |
| Accuracy | ±5% of reading (gas) |
| Linearity Error | ±2% FS |
| Brand | Genetec |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Portable |
| Model | KB-6D |
| Compliance | HJ 732–2014, HJ 38–2017, HJ 604–2017 |
| Sampling Principle | Vacuum-assisted passive bag sampling with positive-pressure purge and negative-pressure draw |
| Power Supply | Rechargeable Li-ion battery (AC/DC compatible) |
| Flow Control | Adjustable sampling pump |
| Sample Interface | PTFE-filtered heated sampling probe |
| Tubing Material | Chemically inert (perfluoroalkoxy, PFA or equivalent) |
| Weight | Lightweight, field-portable design |
| Operating Mode | Manual valve-actuated purge-and-fill cycle |
| Brand | Geotech (UK) |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | SEM5K |
| Instrument Type | Portable |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Detection Target | CH₄ only |
| Range | 0 ppmv to 100% vol |
| Response Time (T90) | ≤2.5 s (standard configuration) |
| Accuracy | ±0.7 ppm (1–10 ppm), ±10% FS (10–10,000 ppm) |
| Resolution | 0.1 ppm / 0.1% vol |
| LOD | 0.3 ppm |
| Pump Flow Rate | 0.6–1.0 L/min (typ. 0.8 L/min) |
| Operating Temp | −25°C to +50°C |
| IP Rating | IP65 |
| ATEX Certification | II 2G Ex ib op is IIB T3 Gb (Ta = −25°C to +50°C) |
| Dimensions | 229 × 97 × 109 mm |
| Weight | 1.3 kg |
| Battery | Rechargeable Li-ion (3.7 V, 4000 mAh) |
| Runtime | 10 h @ 20°C (backlight on), 8 h at temperature extremes |
| Charging Time | 4.5 h (from full discharge) |
| Display | 240 × 128 pixel monochrome graphic LCD |
| Connectivity | Integrated GPS (2–4 m accuracy), Bluetooth 4.0 |
| Enclosure Material | Carbon-fiber-reinforced polyamide |
| Alarm | Audible (65 dB(A) @ 30 cm), visual, and vibration alerts |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PF-300 (Benzene Extension Version) |
| Instrument Type | Portable |
| Detection Principle | High-Temperature Catalytic Oxidation + Flame Ionization Detection (FID) |
| Measured Parameters | Methane (CH₄), Total Hydrocarbons (THC), Non-Methane Hydrocarbons (NMHC), Benzene, Toluene, Ethylbenzene, Xylenes (BTEX) |
| Detection Limit | < 0.1 ppm (as benzene) |
| Repeatability | RSD < 3% |
| Sample Path Temperature Control | Full-path heated up to 200 °C |
| FID Operating Temperature | Heated to 250 °C |
| Internal Gas Supply | Solid-state metal hydride hydrogen generator (3000 refills, 30 h continuous operation) |
| Calibration | Multi-range built-in calibration curves traceable to NIST-certified standards |
| Data Interface | Bluetooth/Wi-Fi, USB-C, mobile app support with real-time cloud sync |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Detection Principle | Catalytic Oxidation–Flame Ionization Detection (CO-FID) |
| Measured Parameters | Methane (CH₄), Total Hydrocarbons (THC), Non-Methane Hydrocarbons (NMHC) |
| Measurement Range | Field-Expandable |
| Detection Limit | mgC/m³ |
| Repeatability | Low Relative Standard Deviation |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Detection Principle | Catalytic Oxidation + Flame Ionization Detection (FID) |
| Measured Parameters | Methane (CH₄), Total Hydrocarbons (THC), Non-Methane Hydrocarbons (NMHC) |
| Detection Limit | mgC/m³ |
| Repeatability | Low Relative Deviation |
| Measurement Range | Expandable |
| Compliance | HJ 1331–2023, HJ 1012–2018, GB 37822–2019, DB11/T 1367–2016, DB37/T 3922–2020, DB35/T 1913–2020 |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Detection Principle | Catalytic Oxidation + Flame Ionization Detection (FID) |
| Measured Parameters | Methane (CH₄), Total Hydrocarbons (THC), Non-Methane Hydrocarbons (NMHC) |
| Measurement Range | Expandable |
| Detection Limit | mg C/m³ |
| Repeatability | Low Relative Deviation |
| Brand | INFICON |
|---|---|
| Origin | Sweden |
| Model | IRwin |
| Instrument Type | Portable |
| Certification | ATEX II 1G, IECEx Ex ia IIC T3, EPL Ga, UL Listed Class I, Division 1, Groups B, C, D, T3 |
| Detection Principle | Dual-Mode Infrared (IR) + Gas Chromatography (GC) |
| Measurement Range | 1 ppm – 100 vol% CH₄ |
| Response Time (T90) | <2 s (IR mode) |
| IP Rating | IP54 |
| Operating Modes | Ground Survey, Probe Pinpointing, Universal Mode |
| GPS Integration | Yes |
| Wireless Data Transmission | Bluetooth® 5.0 + optional LTE module |
| Battery Life | 4 h runtime after 1 h fast charge |
| Compliance | DVGW G465-4, EN 60079-0/-11, ISO 8573-1 (air purity for sampling), US EPA Method 21 (leak detection), applicable OSHA & HSE guidance |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 109A |
| Detection Principle | Dual Flame Ionization Detection (FID) |
| Operating Temperature | 190 °C (heated sample path, detector chambers, and filter) |
| Filter Material | Stainless Steel |
| Filter Pore Size | 2 µm |
| Filtration Mode | Compressed Air or Nitrogen Back-Pulse Cleaning |
| Sample Inlet Configuration | Integrated Heated Sample Line with Adjustable Backplate Condensation Prevention System |
| Compliance | EN 14181, EN ISO 14956, EN 12619, EN 13526, EPA Method 25A, US EPA Reference Method 503 |
| Application Scope | Continuous Emission Monitoring (CEM), Stack Gas Analysis, Ambient Air NMHC Quantification, High-Purity Gas Purity Verification |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 155-15 |
| Sample Flow Range | 10–30 mL/min |
| Operating Temperature | 180 °C (heated sample path) |
| Detector Type | Flame Ionization Detector (FID) |
| Compliance | Designed for ASTM D5114, ISO 8712, and EPA Method 25A-compliant SHED testing |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure | 19″ rack-mountable (5 U) or top-mount configuration |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 3-200 |
| Detection Principle | Flame Ionization Detection (FID) |
| Operating Temperature | 190 °C (heated sample path & detector chamber) |
| Response Time | < 1 s |
| Fuel | Hydrogen (low-pressure metal-hydride cartridge, 40 h runtime) |
| Combustion Air | Integrated air generator (no external cylinder required) |
| Sample Filtration | 2 µm stainless steel filter (permanent or replaceable) |
| Filter Cleaning | Automated compressed air or nitrogen back-purge (measurement uninterrupted) |
| Compliance | EPA Method 25A, EN 12619, ISO 8573-1 (gas purity), GLP/GMP-ready data handling |