AIRTECH
Filter
Showing all 26 results
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ACDW-1000 |
| Quotation | Available Upon Request |
| Cleanliness Class | ISO 5 (Class 100) |
| Filter Efficiency | ≥99.99% @ 0.3 µm |
| Average Air Velocity | ≥0.3 m/s |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power | 300 W |
| Battery Configuration | 38 Ah × 2 (rechargeable DC system) |
| Working Area Dimensions (W×D×H) | 840 × 600 × 670 mm |
| Overall Dimensions (W×D×H) | 1175 × 633 × 1230 mm |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ACP-894 (A/B/C/D) |
| Instrument Type | Non-thermal Plasma + UVC Disinfection System |
| Intended Use | Medical & Laboratory Environments |
| Sterilization Efficacy | ≥99.9% reduction of Staphylococcus albus, Escherichia coli, Staphylococcus aureus, and Poliovirus (per Chinese Disinfection Technical Specifications, 2002 Edition) |
| Disinfection Mechanism | Synergistic Non-thermal Plasma + 254 nm UVC + HEPA Filtration + Photocatalytic Oxidation (TiO₂) |
| Airflow Rate | 640 / 470 / 250 m³/h (High/Standard/Silent Mode) |
| Noise Level | ≤54 / ≤45 / ≤38 dB(A) |
| Power Supply | AC 220 V, 1Φ, 50 Hz |
| Rated Power | 100 / 80 / 60 W |
| Dimensions (W×D×H) | 890 × 400 × 1500 mm |
| Net Weight | 55 kg |
| Applicable Volume | ≤80 m³ |
| Primary Germicidal Agents | Low-pressure mercury UVC lamp (254 nm), Class H13 HEPA filter (≥99.95% @ 0.3 µm), TiO₂-based photocatalyst, and dielectric barrier discharge (DBD) plasma generator |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ACV-03 |
| Price | Upon Request |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power | 200 W |
| Dimensions (L×W×H) | 410 × 210 × 290 mm |
| Max. Water Capacity | 1.2 L |
| Airflow Rate | 0–10 L/min |
| Smoke Output | up to 1.8 L/h |
| Filtration Efficiency | ≥99.97% @ ≥0.3 µm |
| Continuous Operation Time | 40 min |
| Weight | ~13 kg |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ANC-II |
| Quotation | Upon Request |
| Dimensions (mm) | 455 × 340 × 430 |
| Filtration Efficiency | ≥99.99% @ 0.3 µm |
| Airflow Capacity | ≥250 m³/h |
| Power Supply | AC 220 V, 1Φ, 50 Hz |
| Rated Power | 500 W |
| Housing Material | High-Quality Steel with Electrostatic White Powder Coating |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BCDW-1000VR |
| Price | Upon Request |
| Construction Material | SUS304 Stainless Steel |
| Cleanroom Class | ISO 5 (Class 100) |
| Filter Efficiency | ≥99.995% @ ≥0.3 µm |
| Air Velocity | 0.45 ± 20% m/s |
| Noise Level | ≤62 dB(A) |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power | 250 W |
| Battery Configuration | 38 Ah × 3 (UPS + Sealed Lead-Acid Backup) |
| Lift Stroke | ~330 mm |
| Work Area Dimensions (W×D×H) | 840 × 600 × 620 mm |
| Overall Dimensions (W×D×H) | 1000 × 680 × 1750 mm |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Model Variants | BSC-1004IIA2 / BSC-1304IIA2 / BSC-1604IIA2 / BSC-1804IIA2 |
| External Dimensions (L×W×H, mm) | 1200/1500/1800/2000 × 795 × 2050 |
| Internal Work Area Dimensions (L×W×H, mm) | 1004/1304/1604/1804 × 630 × 630 |
| ULPA Filter Efficiency | ≥99.9995% @ 0.12 µm |
| Cabinet Classification | NSF/ANSI 49–2022 Class II, Type A2 |
| Airflow Velocity (Inflow/Downflow) | 0.50–0.55 m/s / 0.25–0.30 m/s (typical, per model and certification) |
| Filter Type | Dual ULPA (Supply & Exhaust) with Leak-Proof Sealing Technology |
| Power Supply | 220 V AC, 50 Hz |
| Motor Type | Brushless DC Constant-Flow Fan |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model Variants | BSC-0605IIA2 / BSC-1005IIA2 / BSC-1305IIA2 / BSC-1605IIA2 / BSC-1805IIA2 |
| Cabinet Type | Class II, Type A2 |
| External Dimensions (L×W×H, mm) | 1200/1500/1800/2000 × 795 × 2050 |
| Internal Work Area Dimensions (L×W×H, mm) | 1004/1304/1604/1804 × 630 × 630 |
| Filter Efficiency | ≥99.995% @ 0.3 µm (EN1822-1 H14/U15 certified) |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model Variants | BSC-0605IIB2 / BSC-1005IIB2 / BSC-1305IIB2 / BSC-1605IIB2 / BSC-1805IIB2 |
| Instrument Class | Class II, Type B2 (Total Exhaust, Non-Recirculating) |
| External Dimensions (L×W×H, mm) | 1200/1500/1800/2000 × 795 × 2050 |
| Internal Work Area Dimensions (L×W×H, mm) | 1004/1304/1604/1804 × 630 × 630 |
| Filter Efficiency | ≥99.995% @ 0.3 µm (HEPA H14 per EN 1822-1) |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BSC-1000III |
| Instrument Type | Class III Biological Safety Cabinet |
| External Dimensions (L×W×H, mm) | 1200×750×2200 |
| Internal Dimensions (L×W×H, mm) | 800×600×650 |
| Filter Efficiency | ≥99.999% at 0.3 µm (HEPA/ULPA dual-stage filtration) |
| Compliance Standard | NSF/ANSI 49-2016 |
| Work Chamber Negative Pressure | ≥120 Pa |
| Airflow Rate | ≥0.05 m³/s |
| Noise Level | ≤65 dB(A) |
| Power Supply | AC 220–240 V, 1φ, 50 Hz |
| Rated Power (excl. outlet) | 1.0 kVA |
| Net Weight | 350 kg |
| Glove Quantity | 2 pairs |
| Lighting | LED, 24.5 W × 1, Illuminance ≥650 lx |
| UV Lamp | 18 W × 1 + 8 W × 1 |
| Cabinet Material | Powder-coated cold-rolled steel (ivory white) |
| Work Area | Seamless 304 stainless steel |
| Exhaust Configuration | Top discharge |
| Cleanliness Class | ISO 5 (Class 100) |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Cabinet Type | Class II, Type B2 (Total Exhaust, Non-Recirculating) |
| Models | BSC-1004IIB2, BSC-1304IIB2, BSC-1604IIB2, BSC-1804IIB2 |
| External Dimensions (L×W×H, mm) | 1200/1500/1800/2000 × 795 × 2050 |
| Internal Work Area Dimensions (L×W×H, mm) | 1004/1304/1604/1804 × 630 × 630 |
| ULPA Filter Efficiency | ≥99.9995% @ 0.12 µm |
| Airflow Control | Brushless DC Constant-Flow Fan with Intelligent Compensation |
| Filter Leak Integrity | Dual “Leak-Resistant” Sealing Technology for Supply & Exhaust Filters |
| Cleanliness Class | ISO 4 (equivalent to Federal Standard 209E Class 10) |
| Power Management | Power-Fail Memory & Standby Mode with Sash-Closure Trigger |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FFU-4X2E |
| Airflow | Configurable per filter and fan selection |
| External Static Pressure | 50–120 Pa |
| Flow Stability | Engineered for uniform laminar airflow distribution with ≤±5% velocity variation across outlet face |
| Auto-sampling | Not applicable |
| Sample Capacity | Not applicable |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GLT-10 |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power | 100 W |
| Max Test Pressure | 5000 Pa |
| Operating Environment | Controlled cleanroom (20–25 °C, RH 40–60%, minimal thermal fluctuation) |
| Dimensions (W×D×H) | 500 × 400 × 1100 mm |
| Weight | ~35 kg |
| Accessories | Sealing Plug or Glove Ring (optional, scalable per glove count) |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Model Variants | HHS-1000-U / HHS-1300-U / HHS-1600-U / HHS-1800-U |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US FED-STD-209E) |
| Airflow Pattern | Horizontal laminar flow |
| Noise Level | ≤62 dBA |
| User Configuration | Single-user single-front or dual-user single-front |
| Compliance | YY/T 1539–2017 (China CFDA Medical Device Standard), Class II Medical Device Registration Certificate |
| Control Interface | Full-color LCD touchscreen with real-time display of airflow velocity, filter status, and fault diagnostics |
| Safety Interlocks | Integrated interlock between sash position, UV germicidal lamp activation, and LED lighting |
| Construction | Seamless curved stainless steel work surface (304 grade), ergonomically optimized for prolonged operation |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Variants | HS-840, HS-840-U, HS-1300, HS-1300-U |
| Instrument Category | Horizontal Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to Federal Standard 209E Class 100 @ ≥0.5 µm) |
| Noise Level | ≤62 dBA |
| User Configuration | Single-user single-face or dual-user single-face |
| Airflow Pattern | Horizontal unidirectional laminar flow |
| Regulatory Compliance | YY/T 1539–2017 (China CFDA Medical Clean Bench Standard), Class II Medical Device Registration Certificate issued |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HS-840-II |
| Instrument Type | Horizontal Laminar Flow Clean Bench |
| Cleanliness Class | ISO 5 (Class 100 per Fed. Std. 209E) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Single-user, single-front configuration |
| Average Air Velocity | ≥0.3 m/s (adjustable) |
| Illumination | ≥300 lx |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power | 250 W |
| Net Weight | 125 kg |
| Work Area Dimensions (W×D×H) | 720 × 650 × 570 mm |
| Overall Dimensions (W×D×H) | 840 × 825 × 1430 mm |
| HEPA Filter Specification | 760 × 610 × 50 mm × 1 unit |
| Settling Microbial Count | ≤0.5 CFU/plate·0.5 h |
| Pre-filter | Quick-release, washable design |
| Safety Compliance | Meets GB/T 25225–2010 (Chinese National Standard for Laminar Flow Clean Benches), IEC 61010-1:2010 (Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use) |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Variants | HS-840-II, HS-1300-II, HS-840-U-II, HS-1300-U-II |
| Instrument Category | Horizontal Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to Federal Standard 209E Class 100 @ ≥0.5 µm) |
| Sound Pressure Level | ≤62 dBA |
| User Configuration | Single-user single-face or dual-user single-face |
| Airflow Pattern | Horizontal unidirectional laminar flow |
| Control Interface | Digital display with touch-sensitive keypad |
| Fan Speed | 3-step adjustable |
| UV Lamp Control | Programmable on/off scheduling |
| Runtime Monitoring | Real-time cumulative operating time for fan, UV lamp, and filter |
| Viewing Panels | Embedded tempered glass on both side walls |
| Work Surface | Seamless 304 stainless steel with front-radius edge design |
| Cabinet Material | Cold-rolled steel with ivory-white electrostatic powder coating |
| Structural Design | Aerodynamically optimized chassis minimizing airflow turbulence |
| Mobility System | Dual-mode casters (swivel + locking brake) with leveling feet |
| Pre-filter Access | Tool-free rapid replacement and washable design |
| Safety Interlock | UV lamp and lighting circuits mutually interlocked |
| Power Features | Integrated backup socket with power-fail protection |
| Factory Certification | Performed per ISO 14644-1, IEST-RP-CC002.3, and GB/T 25227–2010 performance validation protocols |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Model Variants | HVS-1000-U, HVS-1300-U, HVS-1600-U, HVS-1800-U |
| Classification | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to Federal Standard 209E Class 100 @ ≥0.5 µm) |
| Noise Level | ≤62 dBA |
| Operator Configuration | Single-user single-front or dual-user single-front |
| Airflow Pattern | Vertical downward laminar flow |
| Regulatory Compliance | YY/T 1539–2017 (China CFDA Medical Clean Bench Standard), Class II Medical Device Registration Certificate issued |
| Control Interface | Full-color LCD touchscreen with real-time display of inflow velocity, filter status, and fault alerts |
| Safety Interlocks | Integrated interlock between sash position, UV germicidal lamp activation, and lighting system |
| Construction | Seamless curved stainless steel work surface (304 grade), ergonomically contoured front edge |
| Fan System | Variable-air-volume (VAV) EC motor-driven blower with high-efficiency low-energy operation |
| Lighting | Uniform LED illumination (≥600 lux at work surface) |
| Pre-shipment Testing | 100% factory validation per ISO 14644-1 and YY/T 1539–2017 performance & safety protocols |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | LC/GKF Series |
| Pricing | Available Upon Request |
| Filtration Efficiency | ≥99.99% @ ≥0.3 µm (H13), ≥99.995% @ ≥0.3 µm (H14), or Liquid-Seal Configuration (H13/H14 with Gel Seal) |
| Initial Resistance | ≤230 Pa |
| Filter Installation | Bottom-Loading Design |
| Structural Design | Modular, Flange-Mounted Ceiling Assembly |
| Compliance | Designed to meet ISO 14644-1 Class 3–5 cleanroom requirements and GB/T 13554–2020 (Chinese National Standard for High-Efficiency Air Filters) |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Model | MAC-201 |
| Rated Airflow | 200 m³/h (H mode), 160 m³/h (L mode) |
| Flow Stability | High-stability laminar airflow control |
| Filter Efficiency | ≥99.99% @ ≥0.3 µm |
| Noise Level | ≤58 dB(A) |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power | ≤30 W |
| Dimensions (W×D×H) | 365 × 365 × 200 mm |
| Filter Specification | 305 × 305 × 50 mm (1 unit) |
| Weight | 11 kg |
| Brand | AIRTECH |
|---|---|
| Origin | Shanghai, China |
| Model | MAC-600E |
| Instrument Type | Filter-Based Air Purifier |
| Recommended Coverage Area | 10–20 m² |
| Noise Level | ≤56 dB(A) |
| Airflow Velocity | 600 m³/h (not m/s — corrected per industry standard) |
| Cleanliness Class | ≤352,000 particles/m³ (≥0.5 µm, per ISO 14644-1 Class 8 equivalent) |
| Dimensions (W×D×H) | 610 × 610 × 200 mm |
| Filter Efficiency | ≥99.99% @ 0.3 µm (HEPA H14 per EN 1822) |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power Consumption | ≤110 W |
| Filter Configuration | One 610 × 610 × 69 mm HEPA filter cartridge |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | IS-Series Sterile Isolation System |
| Air Cleanliness Class | ISO 5 (Class 100) |
| Filter Efficiency | ≥99.99% @ 0.3 µm |
| Average Air Velocity | 0.45 m/s |
| Power Supply | AC 220 V / 50 Hz |
| Configuration | Custom-engineered footprint (L × W × H, mm) |
| Pressure Control | Dual-mode (positive or negative differential pressure) |
| Transfer Mechanism | Interlocked dual-door pass-through |
| Sterilization Options | Integrated VHP (vaporized hydrogen peroxide) in-situ sterilization or offline autoclave-compatible modular assembly |
| Control System | Microprocessor-based PLC with audit-trail-capable data logging |
| Air Handling | Configurable open-loop or closed-loop recirculation mode |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Variants | SW-CJ-1B, SW-CJ-1BU, SW-CJ-1C, SW-CJ-1CU |
| Instrument Category | Horizontal Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| User Configuration | Single-user single-face or dual-user single-face |
| Airflow Pattern | Horizontal laminar flow |
| Regulatory Compliance | YY/T 1539–2017 (CFDA Medical Device Standard), Class II Medical Device Registration Certificate |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Models | SW-CJ-1F, SW-CJ-1FD, SW-CJ-2F, SW-CJ-2FD |
| Instrument Type | Vertical Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| User Configuration | Single-Operator Single-Face, Single-Operator Dual-Face, Dual-Operator Single-Face, Dual-Operator Dual-Face |
| Airflow Pattern | Vertical Downflow |
| Regulatory Compliance | YY/T 1539–2017 (China CFDA Medical Clean Bench Standard), Class II Medical Device Registration Certificate Issued |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Models | SW-CJ-1B / SW-CJ-1BU / SW-CJ-1C / SW-CJ-1CU-II |
| Instrument Type | Horizontal Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| User Configuration | Single- or Dual-Operator, Front-Access Only |
| Airflow Pattern | Horizontal Laminar Flow |
| Control Interface | Digital Display with Touch-Sensitive Keypad |
| UV Timer Function | Programmable On/Off Scheduling |
| Runtime Monitoring | Real-Time Accumulated Hours for Fan, UV Lamp, and Pre-Filter |
| Viewing Panels | Embedded Tempered Glass on Both Sides |
| Work Surface | Seamless Stainless Steel (AISI 304) |
| Enclosure Material | Cold-Rolled Steel with Ivory White Electrostatic Powder Coating |
| Structural Design | Aerodynamically Optimized Cabinet Profile |
| Mobility System | Locking Swivel Casters (360° Rotation) |
| Pre-Filter Access | Tool-Free Quick-Release Mechanism |
| Safety Interlock | UV Lamp Deactivation When Lighting Circuit Is Active |
| Power Protection | Built-in Backup Socket with Emergency Power-Off Capability |
| Compliance | Factory-Tested per GB/T 25227–2010 (Chinese National Standard for Clean Benches), Meets IEC 61010-1 Safety Requirements for Laboratory Equipment |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Model Variants | SW-CJ-1F, SW-CJ-1FD, SW-CJ-2F, SW-CJ-2FD-II |
| Airflow Type | Vertical Downflow |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| Operator Configurations | Single-Person/Single-Side, Single-Person/Double-Side, Double-Person/Single-Side, Double-Person/Double-Side |
| Construction | Stainless Steel Work Surface, Powder-Coated Cold-Rolled Steel Enclosure |
| Pre-Filter | Quick-Release Design for Easy Cleaning and Replacement |
| UV Lamp Control | Programmable On/Off Scheduling with Runtime Monitoring |
| Fan Speed | Three-Step Adjustable |
| Safety Interlock | Lighting and UV Sterilization Systems Are Electrically Interlocked |
| Power Protection | Built-in Uninterruptible Power Backup Function |
| Mobility | Locking Swivel Casters with Brake Mechanism |
| Compliance | Factory-Tested per GB/T 25223–2010 (Chinese National Standard for Clean Benches), Meets General Requirements of YY 0569–2011 (Medical Device Safety for Biological Safety Cabinets) |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | VS-840K-II |
| Instrument Type | Vertical Flow Clean Bench |
| Cleanliness Class | ISO 5 (Class 100 per Fed. Std. 209E) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Single-user, single-front configuration |
| Airflow Pattern | Vertical unidirectional laminar flow |
| Average Air Velocity | ≥0.3 m/s (adjustable in three stages) |
| Illumination | ≥300 lx |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power | 250 W |
| Net Weight | 145 kg |
| Work Area Dimensions (W×D×H) | 680 × 650 × 570 mm |
| Overall Dimensions (W×D×H) | 840 × 825 × 1625 mm |
| HEPA Filter Specification | 760 × 610 × 50 mm × 1 unit |
| Settling Microbial Count | ≤0.5 CFU/plate·0.5 h |
| Pre-filter | Quick-release, washable design |
| UV Lamp | Scheduled on/off control with runtime logging |
| Safety Interlock | Lighting and UV sterilization systems mutually interlocked |
| Foot Mobility | Dual-mode casters (swivel + locking leveling feet) |