| Brand | Alalis |
|---|---|
| Model | pH400 Educational |
| Type | Benchtop pH Meter |
| Measurement Parameters | pH and mV (ORP) |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 / 0.1 |
| pH Accuracy | ±0.01 |
| Temperature Compensation | Automatic or Manual (0–100 °C) |
| Calibration Options | 1–3 point, with CH and USA buffer series (6 standard buffers supported) |
| Display | 80 × 58 mm LCD, large-font interface |
| Data Storage | 50 manual entries with min/max recall |
| IP Rating | IP54 |
| Included Electrode | Rugged composite plastic-body pH electrode |
| Compliance | Designed for GLP-compliant educational and QC environments |
| Brand | Alalis |
|---|---|
| Model | pH400 Standard |
| Type | Benchtop pH Meter |
| Measurement Parameters | pH and mV (ORP) |
| pH Range | 0.00–14.00 pH |
| pH Resolution | 0.01 / 0.1 pH |
| pH Accuracy | ±0.01 pH |
| mV Range | ±1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±0.1% FS |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | 1–3 point automatic pH calibration with CH and USA buffer series (6 total standard buffers) |
| Temperature Compensation | Automatic or manual (0–100 °C) |
| Data Storage | 200 sets with min/max recall |
| Interface | RS-232 with PC communication software |
| Display | 80 × 58 mm LCD, large-font, backlit |
| Enclosure Rating | IP54 |
| Default Electrode | Plastic-body tri-combination pH electrode |
| Power | 9 V DC adapter |
| Brand | Alalis |
|---|---|
| Model | pH510 Basic |
| Type | Benchtop pH/mV/Temperature Meter |
| Measurement Principle | Potentiometric pH Determination via Glass Electrode |
| pH Range | −2.000 to 19.999 pH |
| pH Resolution | 0.001 / 0.01 / 0.1 pH (selectable) |
| pH Accuracy | ±0.002 pH |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.03% FS |
| Temperature Range | −10.0 to 110.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.4 °C |
| Calibration Options | CH, USA, and NIST buffer series (15 total standard buffers) |
| Calibration Points | 1–5 point automatic calibration with guided prompts and electrode diagnostics |
| Temperature Compensation | Automatic or manual (0.0 to 100.0 °C) |
| Display | 90 × 68 mm LCD with white backlight, large-font numeric readout, real-time clock |
| Data Storage | 500 sets (manual + auto-log), min/max tracking |
| GLP Compliance | Timestamped records, electrode ID logging, calibration history retention |
| Connectivity | USB interface with PC software |
| Environmental Rating | IP54 (dust-protected, splash-resistant) |
| Power | 7.9 V DC adapter |
| Electrode | Integrated high-quality plastic-body triple-junction pH electrode with built-in temperature sensor |
| Special Modes | High-purity water pH mode, ammonia-added pure water mode, redox (E<sub>H</sub>) mode, auto-hold endpoint stabilization |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | pH510 Professional |
| Instrument Type | Benchtop |
| Parameter Types | Dual (pH & mV) |
| pH Measurement Range | −2.000 to 19.999 pH |
| pH Resolution | 0.001 / 0.01 / 0.1 pH |
| pH Accuracy | ±0.002 pH |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.03% FS |
| Temperature Range | −10 to 110 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.4 °C |
| Calibration Buffers | CH, USA, and NIST series (15 standard solutions + user-defined) |
| Temperature Compensation | Automatic or manual (0–100.0 °C) |
| Data Storage | 500 sets (manual & auto), with min/max tracking |
| Display | 90 × 68 mm LCD with white backlight, time stamp |
| Connectivity | USB interface |
| Enclosure Rating | IP54 |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Model | pH510 Standard |
| Type | Benchtop pH Meter |
| Measurement Parameters | pH and mV (Redox) |
| pH Range | −2.000 to 19.999 pH |
| pH Resolution | 0.001 / 0.01 / 0.1 pH |
| pH Accuracy | ±0.002 pH |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.03% FS |
| Temperature Range | −10 to 110 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.4 °C |
| Temperature Compensation | Automatic or Manual (0 to 100.0 °C) |
| Calibration Options | 1–5 point automatic calibration with CH, USA, and NIST buffer series (15 total standard buffers) |
| Special Modes | High-purity water pH mode, ammonia-added pure water pH mode, ORP (E<sub>H</sub>) mode |
| Display | 90 × 68 mm LCD with white backlight, time stamp, large-font readability |
| Data Storage | 500 groups (manual & auto), min/max tracking |
| GLP Compliance | Yes (audit-trail enabled data logging) |
| Connectivity | USB interface with PC software |
| Enclosure Rating | IP54 |
| Power Supply | 9 V DC adapter |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-Br |
| Instrument Type | Benchtop Multi-Ion Analyzer |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| IP Rating | IP54 |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-Ca |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Measurement Accuracy | ±0.01 pX (for monovalent ions) / ±0.02 pX (for divalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX, 0.01 mol/L, 0.01 mg/L, 0.01 ppm |
| pH Range | −2.000–19.999 pH |
| pH Accuracy | ±0.002 pH |
| mV Range | −1999.9 to +1999.9 mV |
| mV Accuracy | ±0.03% FS |
| Temperature Accuracy | ±0.4 °C |
| Data Storage Capacity | 1000 sets |
| Interface | USB |
| IP Rating | IP54 |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| Brand | Alalis |
|---|---|
| Model | PI5100-CL |
| Type | Benchtop Ion Concentration Meter |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000–19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| Protection Rating | IP54 |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-F |
| Instrument Type | Benchtop Ion Analyzer |
| Ion Measured | Fluoride (F⁻) |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | ≤1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| IP Rating | IP54 |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-I |
| Instrument Type | Benchtop Multi-Ion Analyzer |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| IP Rating | IP54 |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-K |
| Instrument Type | Benchtop Multi-Ion Analyzer |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| Protection Rating | IP54 |
| Compliance | GLP-compliant data management, ASTM D1129, ISO 7888, USP <791>, FDA 21 CFR Part 11-ready audit trail support |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-Na |
| Instrument Type | Benchtop Sodium Ion Analyzer |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | ≤1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| IP Rating | IP54 |
| Compliance | GLP-compliant data management, supports ASTM D1129, ISO 10523, and USP <791> for ion-selective electrode methodology |
| Brand | Alalis |
|---|---|
| Origin | USA |
| Model | SX-1102 |
| Type | Box-Type Muffle Furnace |
| Max Temperature | 1100 °C |
| Temperature Control Accuracy | ±3 °C |
| Rated Power | 1.5 kW |
| Heating Time to Max Temp | 35–65 min |
| Internal Dimensions | 120 × 200 × 80 mm (L×W×H) |
| External Dimensions | 380 × 495 × 584 mm (L×W×H) |
| Chamber Volume | 2 L |
| Heating Element | Fe-Cr-Al Alloy Wire |
| Insulation Material | Alumina Ceramic Fiber |
| Temperature Sensor | K-Type Thermocouple |
| Power Supply | 220 V, 50/60 Hz, Single Phase |
| Weight | 35 kg |
| Programmable Stages | Yes |
| Data Storage | USB Interface (Optional) |
| Safety Features | Over-Temperature Protection, Door Interlock, Over-Current & Overload Protection, Surface Cooling Fan, Auto-Calibration, PID Control, Power-Fail Memory |
| Brand | Alalis |
|---|---|
| Origin | USA |
| Model | SX-1107 |
| Instrument Type | Box-Type Muffle Furnace |
| Maximum Temperature | 1100 °C |
| Temperature Control Accuracy | ±3 °C |
| Rated Power | 3 kW |
| Heating Time to Max Temp | 35–65 min |
| Internal Dimensions | 200 × 300 × 120 mm (L × W × H) |
| External Dimensions | 460 × 650 × 674 mm (L × W × H) |
| Chamber Volume | 7 L |
| Heating Element | Fe-Cr-Al Alloy Wire |
| Insulation Material | Alumina Ceramic Fiber |
| Thermocouple Type | K-Type |
| Power Supply | 220 V, 50/60 Hz, Single Phase |
| Weight | 45 kg |
| Programmable Stages | Multi-segment |
| Data Storage | USB Interface (Optional) |
| Safety Features | Overtemperature Protection, Door Interlock, Overcurrent & Overload Protection, Surface Cooling Fan, Auto-Calibration, Power-Fail Memory |
| Brand | Alalis |
|---|---|
| Origin | USA |
| Model | SX-1112 |
| Instrument Type | Box-Type Muffle Furnace |
| Maximum Temperature | 1100 °C |
| Temperature Control Accuracy | ±3 °C |
| Rated Power | 4 kW |
| Heating Time to Max Temp | 35–65 min |
| Internal Dimensions | 300 × 200 × 200 mm (L × W × H) |
| External Dimensions | 490 × 690 × 730 mm (L × W × H) |
| Chamber Volume | 12 L |
| Heating Element | Fe-Cr-Al Alloy Wire |
| Insulation Material | Alumina Ceramic Fiber |
| Thermocouple Type | K-Type |
| Power Supply | 220 V, 50/60 Hz, Single Phase |
| Weight | 67 kg |
| Programmable Stages | Multi-segment (up to 7 user-storable profiles) |
| Safety Features | Overtemperature protection, door interlock, overcurrent/overload protection, surface cooling fan, thermal runaway alarm |
| Optional | USB data logging interface |
| Brand | Alalis |
|---|---|
| Origin | USA |
| Model | SX-1202 |
| Instrument Type | Box-Type Muffle Furnace |
| Maximum Temperature | 1200 °C |
| Temperature Control Accuracy | ±3 °C |
| Rated Power | 1.5 kW |
| Heating Time to Max Temp | 30–52 min |
| Internal Dimensions | 120 × 200 × 80 mm (L×W×H) |
| External Dimensions | 380 × 495 × 584 mm (L×W×H) |
| Chamber Volume | 2 L |
| Heating Element | Fe-Cr-Al Alloy Wire |
| Insulation Material | Alumina Ceramic Fiber |
| Thermocouple Type | K-Type |
| Power Supply | 220 V, 50/60 Hz, Single Phase |
| Weight | 35 kg |
| Programmable Stages | Multi-segment |
| Data Storage | USB Interface (Optional) |
| Safety Features | Overtemperature Protection, Door Interlock, Current Overload Protection, Surface Cooling Fan, PID Auto-Tuning, Power Failure Memory, Scorch-Resistant Housing |
| Brand | Alalis |
|---|---|
| Origin | USA |
| Model | SX-1207 |
| Instrument Type | Box-Type Muffle Furnace |
| Maximum Temperature | 1200 °C |
| Temperature Control Accuracy | ±3 °C |
| Rated Power | 3 kW |
| Heating Time to Max Temp | 30–52 min |
| Internal Dimensions | 200 × 300 × 120 mm (L × W × H) |
| External Dimensions | 460 × 650 × 674 mm (L × W × H) |
| Chamber Volume | 7 L |
| Heating Element | Fe-Cr-Al Alloy Wire (Grade 07) |
| Insulation Material | Alumina Ceramic Fiber |
| Thermocouple Type | K-Type |
| Power Supply | 220 V, 50/60 Hz, Single Phase |
| Weight | 45 kg |
| Chimney Port | Yes |
| Programmable Ramp/Soak | Yes (7 Presets) |
| USB Data Export (Optional) | Yes |
| Safety Features | Over-Temperature Protection, Door Interlock Switch, Overcurrent & Overload Protection, Surface Cooling Fan, Auto Memory on Power Loss |
| Brand | alalis |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Equipment |
| Model | SX-1212 |
| Instrument Type | Box-Type Muffle Furnace |
| Maximum Temperature | 1200 °C |
| Temperature Control Accuracy | ±3 °C |
| Rated Power | 4 kW |
| Heating Time to Max Temp | 30–52 min |
| Internal Chamber Dimensions | 300 × 200 × 200 mm (L×W×H) |
| External Dimensions | 490 × 690 × 730 mm (L×W×H) |
| Chamber Volume | 12 L |
| Heating Element Material | Fe-Cr-Al Alloy Wire |
| Insulation Material | Alumina Ceramic Fiber |
| Thermocouple Type | K-Type |
| Power Supply | 220 V, 50/60 Hz, Single Phase |
| Weight | 67 kg |
| Programmable Stages | Multi-segment (up to 7 preset programs) |
| Safety Features | Overtemperature Protection, Door Interlock Switch, Overcurrent & Overload Protection, Surface Cooling Fan, Auto-Calibration PID Controller |
| Optional Data Interface | USB (for program export/import) |