| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-Br |
| Instrument Type | Benchtop Multi-Ion Analyzer |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| IP Rating | IP54 |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-Ca |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Measurement Accuracy | ±0.01 pX (for monovalent ions) / ±0.02 pX (for divalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX, 0.01 mol/L, 0.01 mg/L, 0.01 ppm |
| pH Range | −2.000–19.999 pH |
| pH Accuracy | ±0.002 pH |
| mV Range | −1999.9 to +1999.9 mV |
| mV Accuracy | ±0.03% FS |
| Temperature Accuracy | ±0.4 °C |
| Data Storage Capacity | 1000 sets |
| Interface | USB |
| IP Rating | IP54 |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| Brand | Alalis |
|---|---|
| Model | PI5100-CL |
| Type | Benchtop Ion Concentration Meter |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000–19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| Protection Rating | IP54 |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-F |
| Instrument Type | Benchtop Ion Analyzer |
| Ion Measured | Fluoride (F⁻) |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | ≤1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| IP Rating | IP54 |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-I |
| Instrument Type | Benchtop Multi-Ion Analyzer |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| IP Rating | IP54 |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-K |
| Instrument Type | Benchtop Multi-Ion Analyzer |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | 1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| Protection Rating | IP54 |
| Compliance | GLP-compliant data management, ASTM D1129, ISO 7888, USP <791>, FDA 21 CFR Part 11-ready audit trail support |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PI5100-Na |
| Instrument Type | Benchtop Sodium Ion Analyzer |
| Measurement Range | 0.00–14.00 pX |
| Detection Limit | 0.01 ppm |
| Response Time | ≤1 s |
| Accuracy | ±0.01 pX (for monovalent ions) |
| Temperature Range | −10 to 110 °C |
| Resolution | 0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm |
| pH Range | −2.000 to 19.999 pH |
| mV Range | −1999.9 to +1999.9 mV |
| Temperature Compensation | Automatic/manual (0–60.0 °C for ion mode |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Display | 90 × 68 mm LCD with white backlight and real-time clock |
| IP Rating | IP54 |
| Compliance | GLP-compliant data management, supports ASTM D1129, ISO 10523, and USP <791> for ion-selective electrode methodology |
| Brand | ASIDA |
|---|---|
| Model | LZ21 |
| Type | Sodium Ion–Specific Dynamic Conductivity-Based Ionic Contamination Tester for Printed Circuit Boards |
| Measurement Principle | Dynamic Extraction + Conductivity Monitoring per IPC-TM-650 2.3.25.1 & J-STD-001 |
| Operating Temperature | 40 °C ± 0.3 °C |
| Extractant Volume Options | 17 L (standard), 30 L (enlarged) |
| PCB Test Area Range | 1200–8712 cm² |
| Conductivity Resolution | 0.0001 µS/cm² |
| Accuracy | ±5% |
| Power | 1700 W |
| Dimensions (enlarged) | 1401 × 600 × 1000 mm |
| Weight (enlarged) | ~150 kg |
| Compliance | IPC-TM-650, J-STD-001, ISO 9001-aligned test environment control |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Range (Ca²⁺) | 0.02–4010 ppm |
| Detection Range (F⁻) | 0.02–1900 ppm |
| Resolution | 0.01 ppm |
| Accuracy | ±5% of full scale |
| Output Signal | Isolated 4–20 mA (max load 1 kΩ) |
| Operating Temperature | 0–55 °C |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 400 × 300 × 150 mm |
| Display | 7-inch color touchscreen with multilingual UI |
| Data Storage | Internal memory + optional 8 GB microSD/USB drive |
| Calibration | ≥5-point linear or empirical calibration |
| Brand | AVVOR |
|---|---|
| Model | 9000 |
| Type | Online Ion Analyzer |
| Detection Range (Ca²⁺) | 0.02–4010 ppm |
| Detection Range (F⁻) | 0.02–1900 ppm |
| Resolution | 0.01 ppm |
| Accuracy | ±5% of full scale |
| Detection Limit | 0.1 ppm |
| Response Time | 30 s |
| Measurement Precision | 0.1 ppm |
| Output Signal | Isolated DC 4–20 mA (max load 1 kΩ) |
| Operating Temperature | 0–55 °C |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 400 × 300 × 150 mm |
| Display | 7-inch color touchscreen |
| Data Storage | Internal memory + optional 8 GB microSD/USB drive |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Range (Ca²⁺) | 0.02–4010 ppm |
| Detection Range (F⁻) | 0.02–1900 ppm |
| Resolution | 0.01 ppm |
| Accuracy | ±5% of full scale |
| Output Signal | Isolated 4–20 mA (max load 1 kΩ) |
| Operating Temperature | 0–55 °C |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 400 × 300 × 150 mm |
| Display | 7-inch color touchscreen |
| Data Storage | Internal memory (8 GB microSD and USB flash drive optional) |
| Auto-cleaning module | Optional |
| Remote monitoring | Optional 3G/GPRS + web-based SCADA interface |
| SMS alert system | Optional multi-user configurable messaging |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Potentiometric measurement using fluoride-selective ion electrode (F⁻-ISE) with TISAB-based sample conditioning |
| Measurement Range (F⁻) | 0.02–1900 ppm |
| Resolution | 0.01 ppm |
| Accuracy | ±5% of full scale |
| pH Operating Range | 4–9 (optimized with TISAB buffer) |
| Output Signal | Isolated 4–20 mA, max load 1 kΩ |
| Operating Temperature | 0–55 °C |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 400 × 300 × 150 mm |
| Display | 7-inch color touchscreen with multilingual UI |
| Data Storage | Internal memory + optional 8 GB microSD/USB storage |
| Auto-cleaning | Configurable timer-based cleaning cycle (cleaning module sold separately) |
| Calibration | ≥5-point linear or empirical calibration curve |
| Compliance | Designed for continuous water quality monitoring per ISO 10304-1, ASTM D1179, and EPA Method 300.0 guidelines |
| Sample Compatibility | Drinking water, surface water, wastewater, industrial effluent, and groundwater |
| Brand | BBE/bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BG00750003 |
| Instrument Type | Benchtop |
| Analyte | Chloride Ion |
| Measurement Range | 0.1 mg/L |
| Limit of Detection (LOD) | 0.8 mg/L |
| Response Time | 10 min |
| Measurement Accuracy | ≤2% |
| Operating Temperature Range | 0–45 °C |
| Communication Interfaces | 4–20 mA, RS232/RS485, MODBUS RTU/TCP, TCP/IP (optional) |
| Brand | BEIYU TECHNOLOGIES |
|---|---|
| Origin | Shanghai, China |
| Model | CCL-100 |
| Instrument Type | Online Chloride Analyzer |
| Measurement Range | 0–3000 mg/L Cl⁻ |
| Detection Limit | ≤2% RSD (Relative Standard Deviation) |
| Response Time | ≤10 min per sample |
| Measurement Accuracy | ±0.02 mg/L (at low concentration range) |
| Compliance | Fully aligned with GB/T 5750.5–2023 (Standard Methods for Examination of Drinking Water – Inorganic Nonmetallic Indicators – Chlorides) |
| Automation Features | Auto-sampling, auto-dilution, auto-titration with AgNO₃, auto-calibration of silver nitrate standard, auto-rinsing of reaction cell, scheduled testing, real-time data upload via Modbus TCP/RS485 |
| Brand | Beiyu Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ECF-100 |
| Pricing | Available Upon Request |
| Sample Capacity | 78 or 118 positions |
| Reaction Vessel | 120 mL plastic tube |
| Constant-Temperature Positions | 10 |
| Detection Limit | 0.05 mg/L |
| Upper Detection Range | 1900 mg/L |
| Sensor | Fluoride Ion-Selective Electrode (ISE) |
| Compliance Standard | GB/T 7484–1987 |
| Brand | CLEAN |
|---|---|
| Origin | Shanghai, China |
| Model | CS6510Cl |
| Instrument Type | Online ISE Sensor |
| Measurement Range | 0–99,999 mg/L (ppm) Cl⁻ |
| Detection Limits | 0.01 / 0.1 / 1 mg/L (ppm) |
| Response Time | 30 s (to 95% signal stability) |
| Accuracy | ±2.5% of reading |
| Operating Temperature | 0–50 °C |
| Output Interface | BNC |
| Body Material | Glass |
| Dimensions | Ø12 × 110 mm |
| Reference System | Double-junction Ag/AgCl with annular ceramic frit |
| Interferents | S²⁻, I⁻, CN⁻, Br⁻ |
| pH Range | 2–12 |
| Input Impedance | <1 MΩ |
| Temperature Compensation | Not recommended for direct electrode compensation |
| Storage | Long-term—dry |
| Electrode Slope | 56 ± 3 mV/decade at 25 °C |
| Brand | CLEAN |
|---|---|
| Origin | Shanghai, China |
| Model | CS6510F |
| Instrument Type | Online ISE Probe |
| Measurement Range | 0–99,999 mg/L (ppm) F⁻ |
| Detection Limits | 0.01 / 0.1 / 1 mg/L (ppm) |
| Response Time | 30 s (to 95% signal stability) |
| Accuracy | ±2.5% of reading |
| Operating Temperature | 0–50 °C |
| pH Range | 5–8 |
| Temperature Compensation | Integrated |
| Reference Electrode | Double-junction, annular ceramic junction |
| Body Material | Glass |
| Dimensions | Ø12 × 110 mm |
| Connector | BNC |
| Pressure Rating | 0–70 psi |
| Interface Compatibility | Compatible with pH meters, ion meters, and online ion analyzers (e.g., ION5000 series) |
| Interferences | Al³⁺, Fe³⁺ (requires masking agents or pH control) |
| Storage | Long-term—dry |
| Electrode Slope | 57 ± 2 mV/decade at 25 °C |
| Input Impedance | 100–200 kΩ |
| Equivalence Point | 20 ppm F⁻ (for potentiometric titration support) |
| Brand | CLEAN |
|---|---|
| Origin | USA |
| Model | CS6510NH4 |
| Instrument Type | Online ISE |
| Measurement Range | 0–99,999 mg/L (ppm) NH₄⁺ |
| Detection Limit | 0–99,999 mg/L (ppm) NH₄⁺ |
| Response Time | ≤30 s to 95% of final value |
| Accuracy | ±2.5% of reading |
| Operating Temperature Range | –10 °C to +150 °C |
| pH Range for Measurement | 4–10 |
| Reference Electrode | Dual-salt-bridge with annular ceramic junction |
| Body Material | Glass |
| Dimensions | Ø12 × 110 mm |
| Cable Length | 1 m |
| Connector | BNC |
| Output Impedance | ≥100 MΩ |
| Temperature Compensation | Integrated |
| Pressure Rating | Not specified |
| Interference | K⁺ (significant), other monovalent cations (moderate) |
| Storage | Long-term — dry |
| Brand | CLEAN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CS6710Ca |
| Instrument Type | Online-Ready ISE |
| Measurement Range | 0.1–18,000 ppm NH₄⁺ |
| Detection Limit | 0.1 ppm NH₄⁺ |
| Response Time | ≤30 s to 95% of final signal |
| Output Sensitivity | 55 ± 3 mV/decade |
| Operating Temperature | 0–50 °C |
| pH Range for Measurement | 4–10 |
| Input Impedance | 20–50 MΩ |
| Reference System | Double-junction Ag/AgCl with single-pore ceramic junction |
| Body Material | PMMA + PVC |
| Threaded Connection | PG13.5 / NPT 3/4″ |
| Cable Length | 5 m |
| Pressure Rating | 0–2 atm |
| Temperature Compensation Options | 10 kΩ, 22 kΩ, PT100, or PT1000 thermistors |
| Zero Point Calibration | 10 ppm NH₄⁺ isopotential point |
| Interference | K⁺ (significant), Na⁺ (minor), Ca²⁺/Mg²⁺ (negligible at pH 4–10) |
| Storage | Long-term — dry |
| Compatible Instruments | Benchtop ion meters, pH/mV meters with millivolt input, and OEM online ammonia analyzers |
| Brand | Rikorika |
|---|---|
| Origin | Japan |
| Model | CU-5ZL |
| Instrument Type | Portable |
| Measurement Range | 0–76.3 g/L Cu²⁺ |
| Detection Limit | 1 g/L |
| Operating Temperature | −5°C to +45°C |
| Accuracy | ±2% of theoretical value (under specified conditions) |
| Calibration | Span calibration using certified Cu standard solution |
| Power Supply | 3× AAA alkaline batteries (LR03), auto-off after 30 min |
| Dimensions | 38 mm (H) × 75 mm (W) × 180 mm (D) |
| Weight | ~300 g |
| Display | 3½-digit LCD |
| Measurement Modes | Cu²⁺ (g/L), Cu molarity (mol/L), CuSO₄ (g/L) |
| Optical System | LED light source with reference beam and automatic intensity compensation |
| Sensor Material | Chemically resistant alloy optimized for acidic electroplating baths (H₂SO₄, H₂O₂ tolerant) |
| Temperature Compensation | Built-in thermistor with real-time correction algorithm |
| Brand | Kasuri Rikka |
|---|---|
| Origin | Japan |
| Model | CU-5Z |
| Instrument Type | Portable |
| Ion Detection Capability | Multi-ion (Cu²⁺-optimized) |
| Measurement Principle | UV-Vis Spectrophotometry (LED-based, dual-wavelength with reference light) |
| Measuring Range | Cu²⁺: 0.0–76.3 g/L |
| CuSO₄ | 0.0–300 g/L |
| Molarity | 0.000–1.200 mol/L |
| Detection Limit | 0.1 g/L (as Cu) |
| Accuracy | ±2% of theoretical value (under controlled calibration conditions) |
| Response Time | 1 s |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤85% RH |
| Power Supply | 3× AAA alkaline batteries (LR03), auto-off after 30 min |
| Dimensions | 38 mm (H) × 75 mm (W) × 180 mm (D) |
| Weight | ~300 g |
| Sensor Material | Chemically resistant alloy with inert optical interface |
| Temperature Compensation | Automatic (NTC-based) |
| Display | 3½-digit LCD |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EasyChem 200 |
| Pricing | Upon Request |
| Instrument Type | Multi-Parameter Ion Analyzer |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Eutech Ion2700 |
| Instrument Type | Multi-Ion Analyzer |
| pH Range | –2.000 to 20.000 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.002 pH + 1 LSD |
| pH Calibration Points | Up to 6 |
| Buffer Standards | USA, NIST, DIN, User 1, User 2, Custom |
| Ion Concentration Range | 0.001–19999 ppm (±2000.0 mV) |
| Ion Resolution | 2- or 3-digit |
| Ion Accuracy | ±0.5% of full scale (monovalent), ±1.0% of full scale (divalent) |
| Ion Calibration Points | 2–8 |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| ORP/mV Range | ±2000.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.2 mV |
| Temperature Compensation | Automatic or Manual (0–100 °C, pH only) |
| GLP Compliance | Yes |
| Slope/Offset Display | Yes |
| Data Storage | 500 records with timestamp |
| Display | Backlit LCD (5.9 × 7.8 cm) |
| Input Interfaces | BNC (pH/ORP/ion), Phono (ATC probe), Phono (reference electrode), DC socket |
| Output Interface | RS232C |
| Power Supply | 9 V DC regulated adapter (100–240 VAC SMPS, 1.3 A) |
| Operating Temperature | 5–45 °C |
| Dimensions (H×W×D) | 17.5 × 15.5 × 6.9 cm |
| Weight (unit) | 650 g |
| Packaging Dimensions | 30.8 × 23.5 × 12.4 cm |
| Shipping Weight | 1800 g |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Eutech Ion700 |
| Pricing | Upon Request |
| Instrument Type | Multi-Ion Analyzer |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–19.999 pX |
| Resolution | 0.001/0.01/0.1 pX (adjustable) |
| mV Range | −1999.9 to +1999.9 mV |
| mV Resolution | 0.1/1 mV (adjustable) |
| Temperature Range | −5.0 to +105.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.3 °C ±1 digit |
| pX Accuracy | ±0.005 pX ±1 digit |
| mV Accuracy | ±0.03% FS ±1 digit |
| Input Impedance | ≥3 × 10¹² Ω |
| Calibration Points | Up to 2-point auto-identification |
| Response Time | ≤3 s |
| Temperature Compensation | Automatic or Manual (−5.0 to +105.0 °C) |
| Data Output | RS232 serial interface |
| Electrode Interface | Universal BNC + temperature sensor port |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C Fluoride Ion Meter |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–19.999 pX |
| Resolution | 0.001/0.01/0.1 pX (adjustable) |
| Accuracy | ±0.005 pX ±1 digit |
| mV Range | −1999.9 to +1999.9 mV |
| mV Resolution | 0.1/1 mV (adjustable) |
| mV Accuracy | ±0.03% FS ±1 digit |
| Temperature Range | −5.0 to +105.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.3 °C ±1 digit |
| Temperature Compensation | Automatic or Manual (−5.0 to +105.0 °C) |
| Input Impedance | ≥3 × 10¹² Ω |
| Calibration Points | Up to 2-point |
| Response Time | ≤3 s |
| Electrode Interface | BNC + RTD (Pt1000 or thermistor) |
| Communication Interface | RS232 |
| Data Storage | Internal calibration history and measurement logs |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Certifications | ISO 9001 certified |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PXJ-1C+ Ammonia-Sensitive Ion Meter |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–99999 ppm |
| Detection Limit | 9999 ppm |
| Response Time | 3 s |
| Measurement Accuracy | ±0.5% FS ±1 digit |
| Temperature Range | −20.0 to 135.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C ±1 digit |
| Input Impedance | ≥3 × 10¹² Ω |
| Data Storage Capacity | 4096 sets |
| GLP Compliance | Yes |
| Calibration Points | 2–9 points (ion), up to 5 points (pH) |
| pH Range | −10.000 to 20.000 |
| pH Resolution | 0.001/0.01/0.1 pH (selectable) |
| pH Accuracy | ±0.002 pH ±1 digit |
| mV Range | −2000.00 to 2000.00 mV |
| mV Resolution | 0.01/0.1/1 mV (selectable) |
| mV Accuracy | ±0.02% FS ±1 digit |
| Units Supported | pX, ppm, ppb, ppt, mol/L, mmol/L, µmol/L, nmol/L, %, µg/L, mg/L, g/L, ng/L |
| Interface | BNC electrode port, Pt1000/NTC temperature input, USB, RS232, 0–20 mV analog output |
| Power Supply | DC 9 V, 500 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C+ Ammonium Ion Meter |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–99,999 ppm |
| Detection Limit | 9,999 ppm |
| Response Time | 3 s |
| Measurement Accuracy | ±0.5% FS ±1 digit |
| Temperature Range | −20.0–135.0 °C |
| Resolution | 0.001 pH / 0.01 mV / 0.1 °C |
| Input Impedance | ≥3 × 10¹² Ω |
| Data Storage Capacity | 4,096 sets |
| GLP Compliance | Yes |
| Calibration Points | 2–9 points (ion), up to 5 points (pH) |
| Temperature Compensation | Automatic (ATC) or Manual |
| Communication Interfaces | USB, RS-232, 0–20 mV analog output |
| Power Supply | DC 9 V, 500 mA (center-positive) |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PXJ-1C+ |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–99999 ppm |
| Detection Limit | 9999 ppm |
| Response Time | 3 s |
| Measurement Accuracy | ±0.5% FS ±1 digit |
| Temperature Range | −20.0–135.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C ±1 digit |
| Input Impedance | ≥3×10¹² Ω |
| Data Storage Capacity | 4096 sets |
| GLP Compliance | Yes |
| Calibration Points | 2–9 points (ion), up to 5 points (pH) |
| Supported Units | pX, ppm, ppb, ppt, mol/L, mmol/L, µmol/L, nmol/L, %, µg/L, mg/L, g/L, ng/L |
| Interface | BNC electrode port, Pt1000/NTC temperature input, USB, RS232, 0–20 mV analog output |
| Brand | FangZhou |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PXJ-1C+ |
| Instrument Type | Benchtop |
| Ion Measurement Range | 0–99999 ppm |
| Detection Limit | 9999 ppm |
| Response Time | 3 s |
| Measurement Resolution | 0.001 (pH), 0.01 mV |
| Temperature Range | −20.0 to 135.0 °C |