All Precision Instrument
Filter
Showing 1–30 of 53 results
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BG-8205 |
| Power Supply | AC 220 V |
| Power Consumption | 250 W |
| Load on Specimen | 26.7 ± 0.2 N |
| Rubber Wheel Rotational Speed | 76 ± 2 rpm |
| Abrasive Wheel Rotational Speed | 34 ± 1 rpm |
| Adjustable Inclination Angle Between Wheels | 15° or 25° |
| Dimensions (L×W×H) | 600 × 480 × 400 mm |
| Net Weight | 60 kg |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0–50,000 µg/L (ppb) as C |
| Accuracy | ±4% of reading |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.05 mg/L |
| Repeatability | ≤3% RSD |
| Conductivity Range Limit | <10.0 µS/cm |
| Sample Temperature Range | 1–90 °C |
| Power Supply | 220 V AC, 50/60 Hz |
| Operating Ambient Temperature | 5–40 °C |
| Display | Color Touchscreen |
| Analysis Time | ≤6 minutes per sample |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0–50,000 ppm (as C) |
| Accuracy | ±4% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Sample Temperature Range | 1–90 °C |
| Analysis Time | <6 minutes |
| Power Supply | 220 V AC |
| Display | Color Touchscreen |
| Compliance | Chinese Pharmacopoeia 2010 Edition |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.5 mg/L |
| Accuracy | ±5% |
| Resolution | 1 µg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Power Consumption | 95 W |
| Dimensions | 340 × 390 × 145 mm |
| Weight | 15 kg |
| Response Time | ≤6 min |
| Sample Temperature Range | 1–95 °C |
| Ambient Temperature | 10–40 °C |
| Relative Humidity | ≤85% RH |
| Linearity Error | ±5% |
| Control Interface | Color Touchscreen with Embedded System |
| Connectivity | Bluetooth Wireless Control |
| Compliance | Chinese Pharmacopoeia 2015 Edition, Appendix VIII R |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Model | BC-40 |
| Detection Principle | Membrane Conductivity Difference Method |
| Oxidation Method | UV Photolysis (185 nm) |
| Measurement Range | 0.001–1.5 mg/L |
| Accuracy | ±5% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Power Consumption | 95 W |
| Dimensions | 340 × 390 × 145 mm |
| Weight | 15 kg |
| Response Time | ≤6 min |
| Sample Temperature Range | 1–95 °C |
| Operating Environment | 10–40 °C, ≤85% RH |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Detection after UV/Persulfate Oxidation |
| Oxidation Method | High-Temperature Catalytic Combustion (supplemented by UV/persulfate for low-level precision) |
| Measurement Range | 0.01–1000 µg/L (0.01–1.000 mg/L) |
| Accuracy | ±4% of reading within calibrated range |
| Resolution | 0.001 mg/L (1 µg/L) |
| Detection Limit | 0.001 mg/L (1 µg/L) |
| Repeatability | ≤3% RSD |
| Sample Temperature Range | 1–95 °C |
| Analysis Time | ≤6 minutes per sample |
| Data Storage | Internal memory supporting ≥6 months of timestamped records |
| Compliance | USP <643>, EP 2.2.44, ChP 2020 Edition (General Chapter 0682), FDA CGMP Annex 1 (Water Systems), ISO 8573-1 (for pharmaceutical compressed air-associated water), GLP/GMP-ready audit trail capability |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BC-40A Standard |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.000 mg/L |
| Accuracy | ±4% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Analysis Time | ≤6 minutes |
| Sample Temperature Range | 1–90 °C |
| Power Supply | 220 V AC |
| Display | Color Touchscreen |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Membrane Conductivity Differential Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.0 mg/L (customizable up to 1000 mg/L via sensor configuration) |
| Accuracy | ±4% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Sample Temperature Range | 1–95 °C |
| Analysis Time | <4 minutes per sample |
| Display | 640×480 color touchscreen |
| Data Storage | 6-month history (≥10,000 records) |
| Interface | RS232 |
| Compliance | Chinese Pharmacopoeia 2010 Edition, Appendix VIII R |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | UV/Persulfate Oxidation + NDIR (Non-Dispersive Infrared) Detection |
| Measurement Range | 0.001–1.0 mg/L (customizable up to 1000 mg/L via sensor configuration) |
| Accuracy | ±4% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Response Time | <4 minutes |
| Sample Temperature Range | 1–95 °C |
| Display | 640×480 color TFT touchscreen |
| Data Storage | 6-month history retention |
| Compliance | Chinese Pharmacopoeia 2010 Edition, Appendix VIII R |
| Interface | RS232 |
| Power Supply | 220 V AC |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Model | BC-40A |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.000 mg/L |
| Accuracy | ±5% |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Analysis Time | 4 min |
| Response Time | ≤15 min |
| Sample Temperature Range | 1–95 °C |
| Ambient Temperature Range | 10–40 °C (max. ±5 °C/day drift) |
| Internal Flow Rate | 0.5 mL/min |
| Relative Humidity | ≤85% |
| Zero Drift | ±5% FS/24 h |
| Span Drift | ±5% FS/24 h |
| UV Lamp | Dual-wavelength (185 nm & 254 nm) |
| Pump Tubing | Imported high-stability peristaltic tubing |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BC-50KV |
| Output Voltage Range | AC/DC 0–50 kV |
| Rated Capacity | 5 kVA |
| Voltage Accuracy | ≤1% |
| Rise Rate Adjustment | 0.1–5.0 kV/s (continuously variable) |
| Test Modes | AC/DC stepwise ramp, constant-rate ramp, and hold-at-level withstand testing |
| Short-Circuit Response Time | ≤0.05 s |
| Leakage Current Measurement Range | 0–200 mA (real-time, mA-resolution) |
| Electrode Set per GB/T 1408.1–2006 | Two Φ25 mm × 25 mm |
| Test Mediums | Air or insulating oil |
| Compliance Standards | IEC 60243-1, ASTM D149, GB/T 1408.1–2006, UL 508, CSA C22.2 No. 0.3 |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BDH-20KV |
| Voltage Range | 0–20 kV (continuously adjustable) |
| Arc Voltage Accuracy | ≤1% |
| Current Acquisition Resolution | Milliampere (mA)-level, real-time sampling |
| Communication Interface | USB 2.0 (up to 3 MB/s), RS-232, Bluetooth 5.0, optional regional Ethernet port |
| Control Mode | PC-based or embedded EPC terminal |
| Electrode Materials | Tungsten carbide, carbon steel, platinum |
| Cabinet Material | AISI 304 stainless steel |
| Compliance Standards | GB/T 1411–2002 (equivalent to IEC 61621:1997), ASTM D495, IEC 149, UL 746A |
| Safety Protections | Dual-stage overvoltage protection, short-circuit interruption, arc fault detection, interlocked safety door, automatic zero-voltage reset, post-test discharge circuit, independent grounding, TVS-based high-voltage surge suppression, software-based misoperation lockout |
| Calibration | Supplied with traceable calibration certificate from nationally accredited metrology institute (CNAS or equivalent) |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BDH-B |
| Output Voltage Range | 0–20 kV AC |
| Rated Power | 1.5 kVA |
| Test Current Options | 10 mA / 20 mA / 30 mA / 40 mA |
| Electrode Configuration | 110° included angle |
| Electrode Materials | Stainless steel plate electrode (25.4 mm × 12.7 mm × 0.15 mm), Tungsten carbide rod electrode (56 mm × 7 mm × 30 mm) |
| Arc Timing Accuracy | <5 ms |
| Voltage Regulation Error | ≤1% |
| Test Modes | Intermittent arc and continuous arc |
| Compliance Standards | GB/T 1411, IEC 61621, ASTM D495, IPC-TM-650 2.5.1, JIS C 2137, UL 746A |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BES |
| Price | USD 1,700 (approx.) |
| Resistance Range | 1 × 10⁴ Ω to 1 × 10¹⁸ Ω |
| Current Range | 2 × 10⁻⁴ A to 1 × 10⁻¹⁶ A |
| Test Voltages | 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V (selectable) |
| Basic Accuracy | ±1% |
| Display | 32-bit LED LCD (simultaneous resistance and current readout) |
| Operating Environment | 0–40 °C, <80% RH |
| Power Supply | AC 220 V, 50 Hz, ~5 W |
| Dimensions | 285 mm × 245 mm × 120 mm |
| Weight | ~2.5 kg |
| Standard Electrodes | Solid disc electrode (Ø100 mm), concentric ring electrode (OD 75 mm / ID 55 ± 0.2 mm), cylindrical electrode (Ø50 mm), point-to-point probe set |
| Shielding Enclosure | 200 mm × 200 mm × 90 mm (internal height 50 mm) |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BEST-121 |
| Test Voltage Range | DC 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V |
| Resistance Measurement Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Measurement Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Volume Resistivity Range | 1.0×10³ Ω·m to 2.0×10¹² Ω·m |
| Surface Resistivity Range | 1.0×10⁴ Ω/□ to 2.0×10¹² Ω/□ |
| Resolution | 0.1×10³ Ω to 0.1×10¹² Ω (adjustable across 1–2 decades) |
| Power Supply | AC 220 V ±10%, 50 Hz ±4%, ≤20 W |
| Dimensions (W×H×L) | 280 mm × 90 mm × 275 mm |
| Net Weight | ≤3.0 kg |
| Compliance | GB/T 1410–2006 / IEC 60093:1980 |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BEST-121 |
| Resistance Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Test Voltages | DC 10 V / 50 V / 100 V / 250 V / 500 V / 1000 V (selectable) |
| Basic Accuracy | ±1% |
| Display | Digital LCD |
| Dimensions | 285 mm × 245 mm × 120 mm |
| Weight | ~5 kg |
| Power Supply | AC 220 V, 50 Hz, ~5 W |
| Brand | All Precision Instrument |
|---|---|
| Model | BEST-121 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Voltage Range | DC 10 V, 50 V, 100 V, 500 V, 1000 V |
| Resistance Measurement Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Measurement Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤70% RH |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Continuous Operation Time | 8 hours |
| Power Consumption | ~10 W |
| Dimensions (W×D×H) | 285 mm × 245 mm × 120 mm |
| Weight | ~6 kg (main unit) |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BEST-212 |
| Resistance Range | 0.01×10⁴ Ω to 1×10¹⁸ Ω |
| Current Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Test Voltages | 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V (selectable) |
| Basic Accuracy | ≤1% |
| Display | Dual LCD (resistance and current simultaneously) |
| Operating Environment | 0–40 °C, RH <80% |
| Power Supply | AC 220 V, 50 Hz, ~5 W |
| Compliance | GB/T 1410–2006, GB 12014, GB/T 20991–2007, GB 4385–1995, GB 12158–2006, GB 4655–2003, GB/T 12703.4–2010, GB/T 12703.6–2010, GB 13348–2009, GB/T 15738–2008, GB/T 18044–2008, GB/T 18864–2002, GB/T 22042–2008, GB/T 22043–2008, GB/T 24249–2009, GB 26539–2011, GB/T 26825–2011, GB 50515–2010, GB 50611–2010, GJB 105–1998-Z, GJB 3007A–2009, GJB 5104–2004 |
| Key | Brand: All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BEST-300C |
| Form Factor | Benchtop |
| Conductivity Range | 5 × 10⁻⁶ – 1 × 10⁸ mS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 1 × 10⁻⁸ – 2 × 10⁶ Ω·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | 0–40 °C |
| Accuracy | ±0.05% of reading |
| Minimum Resolution | 0.1 μΩ |
| Voltage Ranges | 2 mV / 20 mV / 200 mV / 2 V (±0.1% rdg, resolution down to 0.1 μV) |
| Current Output | 0–1000 mA DC, adjustable |
| ranges | 1 μA to 1000 mA (±0.2% rdg ±2 digits) |
| Display | 4.3-inch LCD with auto-unit conversion |
| Interface | Dual-language (English/Chinese), PC-compatible via optional software |
| Dimensions | 330 × 340 × 120 mm |
| Power | 220 V ±10%, 50/60 Hz |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BG-400A1 |
| Internal Dimensions (W×D×H) | 450 × 450 × 500 mm |
| Temperature Range | 10–300 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Range | Not Applicable (Dry Heat / UV Only) |
| UV Wavelength | 340 nm (UVA-340 lamp standard) |
| Black Panel Temperature Range | 40–80 °C (adjustable per test protocol) |
| Irradiance Control | 0.63–1.25 W/m² @ 340 nm |
| Chamber Volume | 100 L |
| Heating Power | 2000 W |
| Power Supply | 220 V AC, 50/60 Hz |
| Compliance | GB/T 2951.12–2008, ASTM G154, ISO 4892-3, IEC 60068-2-5 |
| Brand | All Precision Instrument |
|---|---|
| Model | BG-800 |
| Nominal Internal Volume | 50 L |
| Internal Dimensions (W×D×H) | 350 × 350 × 410 mm |
| External Dimensions (W×D×H) | 1110 × 870 × 1550 mm |
| Temperature Range | −40 °C to +150 °C |
| Temperature Uniformity | ±2.0 °C |
| Temperature Stability | ±0.5 °C |
| Heating Rate (25 °C → 150 °C, unloaded) | ~35 min |
| Cooling Rate (25 °C → −40 °C, unloaded) | ~60 min |
| Power Supply | Standard industrial AC supply (specification compliant with GB/T 10592–2008 and IEC 60068-3-5) |
| Compliance | Designed per ISO 16750-4, ASTM D4329, IEC 60068-2-1 (Cold), IEC 60068-2-2 (Dry Heat), and GB/T 2423.1–2022 / GB/T 2423.2–2022 |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BHG-9102 |
| Internal Dimensions (D×W×H) | 400 × 450 × 550 mm |
| Temperature Range | −40 °C to +150 °C (unloaded) |
| Humidity Range | 20–98 %RH (no active thermal load) |
| Temperature Uniformity | ±2 °C (unloaded) |
| Temperature Fluctuation | ≤±0.5 °C (unloaded) |
| Humidity Fluctuation | ≤±3 %RH |
| Heating Rate | ≤40 min (20 °C to 100 °C) |
| Cooling Rate | ≤30 min (20 °C to −20 °C) |
| Control Accuracy | ±2 °C / ±3 %RH |
| Sensor Type | PT100 armored resistance thermometers (temperature & humidity), dry-wet bulb principle for RH calculation |
| Refrigeration System | Single-stage, imported Tecumseh (France) compressor, R404A refrigerant (DuPont), Danfoss (Denmark) expansion valve, Parker (USA) filter-drier, Castel (Italy) solenoid valve |
| Humidification System | Built-in stainless steel water tank with Taiwan-imported electronic level controller, visual glass water-level indicator |
| Controller | Programmable high-resolution color touchscreen HMI, bilingual (English/Chinese), PID + BTHC balanced temperature-humidity control, 10 program groups × 16 segments (160 total), max segment time 99 h 59 min, up to 999 full cycles, USB data logging support |
| Safety Protections | Over-temperature alarm (chamber & compressor), over-current/overload protection, phase failure & ground fault detection, fan motor thermal protection, dry-run prevention for humidifier, fuse and SSR-based zero-crossing power control, leakage current protection |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | GC Autosampler |
| Model | BKQ-20 |
| Sample Vial Capacity | 12 mL |
| Maximum Vial Count | 196 (14 × 14 array) |
| Positioning Accuracy | ±0.01 mm |
| Power Input | AC 220 V |
| Display | Blue TFT LCD |
| Dimensions (W × D × H) | 490 mm × 482 mm × 330 mm |
| GC Synchronization | Triggered via TTL/relay signal |
| Vacuum Reconditioning | Integrated for vial reuse |
| Communication Interfaces | RS-232, USB, optional Ethernet |
| Sample Injection Modes | Headspace, direct gas loop, split/splitless compatible |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Capillary Rheometer |
| Model | BML-400 |
| Maximum Load Capacity | 10 kN / 25 kN (configurable) |
| Piston Speed Range | 0.0005–20 mm/sec |
| Dynamic Speed Ratio | 1:40,000 |
| Maximum Test Temperature | 400 °C |
| Temperature Control Accuracy | ±0.2 °C (in barrel), ±0.5 °C (overall) |
| Barrel Diameter Options | 9.5 mm, 12 mm, 15 mm (custom lengths available) |
| Capillary Die Options | (1) 5/0.5 mm (L=5 mm, D=0.5 mm), (2) 10/1 mm, (3) 20/1 mm, (4) 30/1 mm, (5) 20/2 mm |
| Pressure Sensor Range | 700–2000 bar (configurable) |
| Die Material | Tungsten carbide |
| Barrel & Piston Material | Nitrided stainless steel, corrosion- and wear-resistant |
| Safety Features | Interlocked front access door, dual overload protection, torque-limiting motor circuit |
| Power Supply | 1-phase, 220 V, 50/60 Hz, 8–12 A |
| Dimensions (W×D×H) | 64×64×165 cm |
| Weight | 250 kg |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Capillary Rheometer |
| Model | BML-400-B |
| Maximum Load Capacity | 25 kN |
| Temperature Range | 50–450 °C |
| Temperature Accuracy | ±0.1 °C (chamber), ±0.2 °C (barrel) |
| Barrel Diameter Options | 9.5, 12, 15 mm (custom lengths available) |
| Piston Speed Range | 0.0005–20 mm/s |
| Dynamic Speed Ratio | 1:40,000 |
| Pressure Sensor Range | Up to 2000 bar |
| Pressure Accuracy | < ±0.25% FS |
| Capillary Dies | Five standard options (e.g., 5/0.5-L=5 mm/D=0.5 mm |
| Die Material | Tungsten carbide |
| Barrel & Piston Material | Nitrided stainless steel |
| Control Mode | Constant piston speed or constant pressure |
| Compliance | ASTM D3835, ISO 11443, GB/T 3680 |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | BP-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (L×W×H) | 500 × 200 × 180 mm |
| Display | 5.7-inch 32-bit touchscreen |
| Language Options | English / Chinese |
| Data Storage | 32 GB (≥1 million test records) |
| Print Output | Bilingual (English/Chinese), including test parameters, results, and pressure decay curves |
| Environmental Operating Conditions | 0–50 °C, 10–80% RH |
| Test Duration | Bubble point: 2 ± 2 min |
| Diffusion flow | 7 ± 2 min |
| Water intrusion | 7 ± 2 min |
| System leak check | 3 ± 1 min |
| Communication Interface | RS232/USB for PC connectivity and remote supervision via proprietary software |
| Compliance Support | Fully compatible with FDA 21 CFR Part 11 audit trail requirements, EU Annex 1, USP <1207>, ISO 13408-2, and GMP Annex 15 integrity testing protocols |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | BQS |
| Price Range | USD 1,400 – 2,800 |
| Power Supply | 100–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 9000 mbar (145 psi) |
| Min Inlet Pressure | 4000 mbar (58 psi) |
| Dimensions | 400 × 380 × 335 mm (W × D × H) |
| Test Pressure Range | 100–8000 mbar (1.5–116 psi) |
| Accuracy | Net Volume Test ±4% |
| Environmental Conditions | 15–35 °C |
| Test Duration | Net Volume Test 5±2 min |
| Water Intrusion Test | Set Time + 5±2 min |
| Display | 5.7″ backlit monochrome LCD |
| Data Interface | RS232 serial port |
| Language Options | English / Chinese |
| Storage Capacity | 500 test records (incl. curves) |
| Print Output | Dot-matrix printer (Chinese/English), full parameter + result + curve |
| Sample Compatibility | Disc membranes Φ25–Φ300 mm |
| Key | Brand: All Precision Instrument |
|---|---|
| Model | BQS-19 |
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Min Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (W×D×H) | 240 × 320 × 260 mm |
| Display | 5.7–7″ color touchscreen (256 colors), GUI in English/Chinese |
| Operating Environment | 0–50 °C, 10–80% RH |
| Data Storage | 32 GB internal (≥1 million test records) |
| Communication Interface | RS232/USB/Ethernet (with PC software for remote control & audit trail) |
| Compliance | Designed to support GMP, FDA 21 CFR Part 11, and ISO 13408-2 requirements |
| Test Modes | Bubble Point, Diffusion Flow, Water Intrusion |
| Typical Test Duration | Bubble Point (2 ± 2 min), Diffusion Flow (7 ± 2 min), Water Intrusion (7 ± 2 min), System Leak Check (3 ± 1 min) |
| Printing | Integrated thermal printer (bilingual report with test parameters, results, and real-time curve) |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BQS-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Test Pressure | 6900 mbar (sensor customizable) |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 10–80% RH |
| Dimensions (W×D×H) | 240 × 320 × 260 mm |
| Display | 5.7–7-inch color touchscreen, 256-color, GUI in English/Chinese |
| Data Storage | 32 GB internal, ≥1 million test records |
| Print Output | Thermal printer, bilingual (English/Chinese), includes test parameters, results, and pressure decay curves |
| Test Duration | Bubble Point: 2 ± 2 min |
| Diffusion Flow | 7 ± 2 min |
| Water Intrusion | 7 ± 2 min |
| System Leak Check | 3 ± 1 min |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BQS-19 Series |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Test Duration (Bubble Point) | 2 ± 2 min |
| Test Duration (Diffusion Flow / Water Intrusion) | 7 ± 2 min |
| System Leak Test Time | 3 ± 1 min |
| Display | 5.7-inch 32-bit touchscreen |
| Data Storage | 32 GB (≥1 million records) |
| Interface | RS232/USB/Ethernet for PC connectivity |
| Compliance Support | FDA 21 CFR Part 11 (audit trail enabled), GMP/GLP-ready |
| Language Options | English & Chinese |
| Dimensions | 500 × 200 × 180 mm (L×W×H) |
| Environmental Operating Range | 0–50 °C, 10–80% RH |