UV Aging Test Chamber
Filter
Showing 1–30 of 253 results
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BG-400A1 |
| Internal Dimensions (W×D×H) | 450 × 450 × 500 mm |
| Temperature Range | 10–300 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Range | Not Applicable (Dry Heat / UV Only) |
| UV Wavelength | 340 nm (UVA-340 lamp standard) |
| Black Panel Temperature Range | 40–80 °C (adjustable per test protocol) |
| Irradiance Control | 0.63–1.25 W/m² @ 340 nm |
| Chamber Volume | 100 L |
| Heating Power | 2000 W |
| Power Supply | 220 V AC, 50/60 Hz |
| Compliance | GB/T 2951.12–2008, ASTM G154, ISO 4892-3, IEC 60068-2-5 |
| Brand | APEC Technology (APKJ) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Model | AP-2-UV |
| Test Duration Range | 1–999 hours (adjustable) |
| Irradiance Range | 0.35–1.0 W/m² |
| UV Lamp Power | 40 W per lamp |
| Humidity Range | ≥95% RH (in-chamber actual value) |
| Light Exposure Temperature Range | +10 to +70 °C |
| Black Panel Temperature Range | 45–80 °C |
| UV Wavelength Range | 315–400 nm (UVA) |
| Internal Chamber Dimensions (L×W×H) | 1160 × 450 × 500 mm |
| Brand | APKJ |
|---|---|
| Model | AP-UV-3 |
| Chamber Internal Dimensions | 1170 × 500 × 450 mm (W×H×D) |
| External Dimensions | 1480 × 1300 × 550 mm (W×H×D) |
| Temperature Range | RT+20°C to 70°C |
| Humidity Range | ≥90% RH |
| Temperature Uniformity | ±1°C |
| Temperature Stability | ±0.5°C |
| UV Irradiance Range | Adjustable up to 1.0 W/m² |
| UV Spectrum Options | UVA-340 (315–400 nm) or UVB-313 (280–315 nm), 8 lamps total (4 per side) |
| Lamp Life | ≥1600 h |
| Black Panel Temperature Range | 50–70°C |
| Sample Holder Capacity | 24 standard frames (75 × 290 mm) |
| Sample-to-Lamp Distance | 50 ± 3 mm |
| Lamp Center Spacing | 70 mm |
| Water Tray Depth | 25 mm (auto-controlled) |
| Effective UV Exposure Area | 900 × 210 mm |
| Test Duration | 0–999 h (programmable) |
| Control System | TEMI880 color touchscreen controller (Korean) or RKC intelligent controller |
| Cooling/Condensation Mode | Automatic condensation cycle |
| Spray Function | Integrated automated water spray system |
| Construction Material | Interior & exterior SUS304 stainless steel |
| Compliance Standards | ASTM D822, D750, D1419, D2263, G23 |
| Optional Accessories | UV radiometer (UVA/UVB), RS232 bidirectional communication interface |
| Brand | Apkji |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | 3AP-UV |
| Pricing | Upon Request |
| UV Lamps | 8 × 40W imported UVA-340 or UVB-313 fluorescent tubes (4 operational + 4 spares) |
| Irradiance Control | Adjustable |
| UV Temperature Range | 50–75 °C |
| Condensation Temperature Range | 40–60 °C |
| Test Capacity | 48 specimens |
| Water Supply | Deionized or distilled water, 18 L/day |
| Dimensions (W×H×D) | 137 × 135 × 53 cm |
| Weight | 136 kg |
| Power Supply | 1φ3W AC220V ±10%, 50/60 Hz, max. 2.2 kW |
| Standards Compliance | ASTM G154, ASTM D4587, ASTM D4799, ISO 4892, SAE J2020, GB/T 16422.3 |
| Brand | Apkji |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | AP-UV-01 |
| Pricing | Upon Request |
| UV Lamps | 8 × 40 W imported Atlas UVA-340 or UVB-313 fluorescent lamps |
| Lamp Life | 1600–1800 h |
| Irradiance Control | Optional CR-10 calibrated radiometer |
| Test Temperature Range | 50–75 °C (UV), 40–60 °C (condensation) |
| Temperature Uniformity | ±3 °C |
| Cycle Options | 4 h UV / 4 h condensation or 8 h UV / 4 h condensation |
| Sample Capacity | 48 pcs (75 × 150 mm or 75 × 300 mm standard clamps, max thickness 20 mm) |
| Chamber Dimensions (W×H×D) | 137 × 135 × 53 cm |
| Weight | 136 kg |
| Power Supply | 1φ 3W AC 220 V ±10%, 50/60 Hz, 2.2 kW (max) |
| Water Consumption | 8–18 L/day (deionized/distilled water) |
| Compliance | ASTM G154, ISO 4892-3, GB/T 16422.3, ASTM D4587, D4799, SAE J2020 |
| Brand | Apkji |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | AP-UV-03 |
| Price | Upon Request |
| Temperature Range | RT to +70°C |
| Humidity Range | ≥90% RH |
| Temperature Uniformity | ±1°C |
| Temperature Fluctuation | ±0.5°C |
| Lamp Center-to-Center Spacing | 70 mm |
| Sample-to-Lamp Distance | 50 mm ±3 mm |
| Irradiance Control Range | 0.5–1.0 W/m² (adjustable) |
| UV Spectrum | UVA (315–400 nm), UVB (280–315 nm) |
| Lamp Type | 1200 mm × 40 W fluorescent UV tubes (UVA-340 / UVB-313 optional), 8 units |
| Rated Lamp Life | ≥1600 h |
| Controller | TEMI880 color touchscreen or RKC intelligent controller |
| Temperature Control Method | PID auto-tuning with SSR output |
| Standard Specimen Size | 75 mm × 290 mm |
| Water Pan Depth | 25 mm (auto-maintained) |
| Effective UV Exposure Area | 900 mm × 210 mm |
| Black Panel Temperature Range | +50°C to +70°C |
| Exposure Cycle Options | UV irradiation, condensation, and water spray (independently programmable) |
| Test Duration | 0–999 h (programmable) |
| Sample Holder Capacity | 24 positions |
| Spray Function | Fully automated |
| Brand | Apkji (APKJ) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AP-3UVB |
| Price | USD 5,700 (approx.) |
| Test Duration Range | 1–999 h·min·sec |
| Irradiance Range | 0.35–1.0 W/m² (adjustable) |
| Lamp Power | 40 W per tube |
| Humidity Range | ≥95% RH |
| Illuminated Chamber Temperature Range | +10°C to 70°C |
| Black Panel Temperature Range | 45°C to 80°C |
| UV Wavelength Bands | 280–315 nm (UVB), 315–400 nm (UVA) |
| Internal Chamber Dimensions (L×W×H) | 1160 × 450 × 500 mm |
| Brand | ATLAS |
|---|---|
| Origin | USA |
| Model | UVCTest |
| Chamber Type | UV-C Environmental Aging Test System |
| Light Source | UVC Germicidal Lamps (254 nm) |
| Temperature Range | Ambient to 80 °C |
| Humidity Control | Optional Integrated RH Module (10–95% RH, ±3% RH) |
| Sample Capacity | Standard 300 mm × 300 mm × 150 mm Exposure Zone |
| Compliance | ASTM G154, ISO 4892-3, IEC 60068-2-5 (UVC-modified), ATLAS Internal UV-C Irradiance Calibration Protocol |
| Brand | ATLAS |
|---|---|
| Origin | USA |
| Model | UVTest |
| Test Duration | 1–9999 h |
| Irradiance Range | Typical 0.89 W/m² (UVA), 0.71 W/m² (UVB) |
| Lamp Power | 40 W per tube |
| Humidity Control | High-humidity mode |
| Illuminated Chamber Temperature Range | 35–80 °C |
| Black Panel Temperature (BPT) Range | UV Phase 35–80 °C |
| Spectral Peak Wavelengths | 351 nm, 340 nm, 313 nm (irradiance-controlled) |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BA-ZW-A |
| Price | USD 4,750 (FOB Shanghai) |
| Temperature Range | Ambient +20°C to +70°C |
| Temperature Uniformity | ±0.5°C |
| Humidity Range | Up to 95% RH |
| Chamber Dimensions (W×D×H) | 1170 mm × 450 mm × 500 mm |
| UV Lamp Wavelength | 280–315 nm (UV-B) |
| Sample-to-Lamp Distance | 90–100 mm |
| Heating & Humidification | Electric Steam Generator |
| Control System | Imported Digital Touch Panel Controller |
| Compliance | GB/T 5170.9–2017 |
| Brand | GHT |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHT-UV3/2 |
| Humidity Range | ≥95% RH (in-chamber actual value) |
| UV Lamp Power | 40 W per lamp |
| Irradiance Range | 1.2 W/m² (typically at 340 nm) |
| Test Duration | 1–9999 h adjustable |
| Illumination Temperature Range | 50–80 °C |
| Black Panel Temperature Range | 30–80 °C |
| UV Wavelength Range | 290–400 nm |
| Chamber Internal Dimensions (L×W×H) | 1100 × 450 × 250 mm |
| Condensation Temperature Control Range | RT+10–70 °C |
| Illumination Temperature Control Range | RT+10–70 °C |
| Temperature Uniformity | ±3 °C |
| Condensation Method | Steam-based condensation |
| Light/Condensation Cycle | 0–9999 h programmable (e.g., 4 h light / 4 h condensation) |
| Lamp Center-to-Center Spacing | 70 mm |
| Sample-to-Lamp Distance | 55 mm |
| UV Lamp Type | UVA-340 fluorescent lamps (standard), optional UVB-313 or UVC-351 |
| Spectral Range Options | UVA: 315–400 nm |
| UVB | 280–340 nm |
| Adjustable Irradiance | 0.1–1.0 W/m² @ 340 nm |
| Lamp Lifetime | 1600–1800 h |
| Spray Cycle Duration | 0–9999 min programmable |
| Standard Specimen Size | 50 × 120 mm (up to 48 specimens per cycle) |
| Control System | Programmable touchscreen HMI (Weinview, Taiwan), Chinese interface |
| Power Supply | AC 220 V, 50 Hz, 4.7 kW |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HD-E802-2 |
| Humidity Range | Ambient to 70°C |
| UV Lamp Power | 40 W per lamp |
| Max Data Logging Duration | 60 days (at 1.5-min sampling interval) |
| Irradiation Temperature Range | Ambient to 70°C |
| UV Wavelength Range | 200–480 nm |
| Chamber Internal Dimensions (W×H×D) | 1300 × 1480 × 550 mm |
| Sample Rack Configuration | Tilted tower, 4 racks × 493 × 300 mm each |
| Sample Size per Rack | 75 × 150 mm (2 slots per rack) |
| Lamp Quantity | 8 fluorescent UV lamps (4 front + 4 rear) |
| Lamp Center-to-Center Spacing | 70 mm |
| Sample Surface-to-Lamp Distance | 50 ± 3 mm |
| Spray Nozzles | 8 (4 front + 4 rear), adjustable pressure 70–200 kPa |
| Lamp Length | 1220 mm |
| Lamp Lifetime | ≥1600 h |
| Temperature Resolution | 0.01°C |
| Temperature Uniformity | ±2°C |
| Temperature Fluctuation | ±1°C |
| Temperature Deviation | ±1°C |
| Control System | Q-TEST touchscreen PID controller with RS-232 interface |
| Compliance Standards | GB/T 23987–2009, ISO 11507:2007, GB/T 14522–2008, GB/T 16422.3–2014, ISO 4892-3:2006, ASTM G154, ASTM G153, IEC 61215:2005 (Clause 10.10) |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JH UV Aging Test Chamber |
| Quotation | Upon Request |
| Humidity Range | ≥95% RH (in-chamber actual value) |
| UV Lamp Power | 40 W per lamp |
| Irradiance Range | 0.72 W/m² |
| Exposure Time Setting | 1–9999 hours (adjustable) |
| Illuminated Surface Temperature Range | Available upon technical consultation |
| Black Panel Temperature Range | Available upon technical consultation |
| UV Wavelength | Available upon technical consultation |
| Chamber Internal Dimensions (L×W×H) | Available upon technical consultation |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-Series UV Aging Test Chamber |
| Humidity Range | ≥95% RH (in-chamber actual value) |
| UV Lamp Power | 40 W per lamp |
| Irradiance Range | 0.72 W/m² (at 340 nm) |
| Exposure Time Control | 1–9999 hours (adjustable) |
| Operating Temperature Range | Consult technical support for application-specific configuration |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-Series UV Aging Test Chamber |
| Price Range | USD 280–11,000 (FOB) |
| Humidity Range | ≥95% RH (in-chamber actual value) |
| UV Lamp Power | 40 W per lamp |
| Irradiance Range | 0.72 W/m² (typically at 340 nm) |
| Exposure Time Setting | 1–9999 hours (adjustable) |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JH-Series UV Aging Test Chamber |
| Quotation | Available upon Request |
| Humidity Range | ≥95% RH (in-chamber actual value) |
| UV Lamp Power | 40 W per lamp |
| Irradiance Range | 0.72 W/m² (at specimen surface, 340 nm nominal) |
| Exposure Time Setting | 1–9999 hours (programmable) |
| Illuminated Surface Temperature Range | Not specified in source data |
| Black Panel Temperature Range | Not specified in source data |
| UV Wavelength | UVA-340 nm (standard for accelerated solar simulation) |
| Internal Chamber Dimensions (L×W×H) | Not specified in source data |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-Series UV Aging Test Chamber |
| Price Range | USD 210–12,000 (FOB) |
| Humidity Range | ≥95% RH (in-chamber actual value) |
| UV Lamp Power | 40 W per tube |
| Irradiance | 0.72 W/m² (at specimen plane, UVA-340 spectral match) |
| Exposure Time Control | 1–9999 hours (programmable) |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-UV Aging Chamber |
| Humidity Range | ≥95% RH |
| UV Lamp Power | 40 W per lamp |
| Irradiance Range | 0.72 W/m² (at 340 nm) |
| Exposure Time | 1–9999 h (adjustable) |
| Operating Temperature Range (Illuminated) | Consult technical support |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JH-UV Accelerated Weathering Test Chamber |
| Price Range | USD 140–9,800 (FOB Shanghai) |
| Humidity Range | ≥95% RH (in-chamber actual value) |
| UV Lamp Power | 40 W per tube |
| Irradiance Range | 0.72 W/m² (at 340 nm) |
| Exposure Time Setting | 1–9999 hours (adjustable) |
| Black Panel Temperature Range | Consult technical support |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-UV |
| Humidity Range | ≥95% RH (in-chamber actual value) |
| UV Lamp Power | 40 W per lamp |
| Irradiance Range | 0.72 W/m² (at 340 nm) |
| Exposure Time Setting | 1–9999 hours (adjustable) |
| Operating Temperature Range | Consult manufacturer for specification |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-UV Weathering Test Chamber |
| Humidity Range | ≥95% RH |
| UV Lamp Power | 40 W per lamp |
| Irradiance Range | 0.72 W/m² (at 340 nm) |
| Test Duration | 1–9999 hours (adjustable) |
| Operating Temperature Range (Illuminated) | Consult technical support |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JH-UV Aging Test Chamber |
| Price Range | USD 140 – 2,800 |
| Humidity Range | ≥95% RH (in-chamber actual value) |
| UV Lamp Power | 40 W per lamp |
| Irradiance Range | 0.72 W/m² (at 340 nm) |
| Exposure Time Setting | 1–9999 hours (adjustable) |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-UV Aging Test Chamber |
| UV Lamp Power | 40 W per lamp |
| Irradiance Range | 0.72 W/m² (adjustable up to 1.0 W/m²) |
| Test Duration | 1–9999 hours (programmable) |
| Lamp Spacing | 70 mm |
| Sample-to-Lamp Distance | 50 ± 3 mm |
| Effective Irradiated Area | 900 × 210 mm |
| Standard Sample Size | 75 × 290 mm |
| Internal Material | 304 Stainless Steel |
| Controller | Color Touchscreen Programmable Logic Controller (PLC) |
| UV Lamps | UVA-340 (standard), optional UVB-313 |
| Protection Features | Overload, short-circuit, over-temperature, and low-water-level safeguards |
| Temperature Range | RT + 40°C to 70°C |
| Humidity Capability | >90% RH (condensation cycle supported) |
| Cycles | UV irradiation, condensation, optional water spray (configurable) |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | Custom UV Aging Test Chamber |
| Humidity Range | ≥95% RH (in-chamber actual value) |
| UV Lamp Power | 40 W per lamp |
| Irradiance Range | 0.72 W/m² (at 340 nm) |
| Exposure Time Setting | 1–9999 hours (adjustable) |
| Compliance | IEC 60068-2-5 (UV radiation), IEC 60068-2-9 (damp heat, cyclic, with condensation and spray) |
| Key Features | Integrated water spray system, programmable UV irradiance control, real-time humidity monitoring, precision black-panel temperature control |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Jianhu UV Aging Test Chamber DV-340 Series |
| Price Range | USD 750 – 75,000 |
| Humidity Range | ≥95% RH |
| Lamp Power | 40 W per lamp |
| Irradiance Range | 0.72 W/m² (at 340 nm) |
| Exposure Time | 1–9999 hours (adjustable) |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | DV-540H |
| Humidity Range | ≥95% RH (in-chamber actual value) |
| UV Lamp Power | 40 W per lamp |
| Irradiance Range | 0.72 W/m² (at 340 nm reference wavelength) |
| Exposure Time Setting | 1–9999 h (adjustable) |
| Air Temperature Range | RT+10°C to 80°C (adjustable) |
| Black Panel Temperature Range | 40°C to 80°C (adjustable) |
| UV Wavelength Band | 280–400 nm (full-spectrum |
| Chamber Dimensions (L×W×H) | 900 × 600 × 500 mm (540 L internal volume) |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DV-540H |
| Price Range | USD 1,350 – 13,500 (FOB Shanghai) |
| Humidity Range | ≥95% RH (in-chamber actual value) |
| Lamp Power | 40 W per tube |
| Irradiance Range | 0.72 W/m² (at 340 nm reference wavelength) |
| Exposure Time | 1–9999 h (programmable) |
| Air Temperature Range | RT+10°C to 80°C (adjustable) |
| Black Panel Temperature Range | 40°C to 80°C (adjustable) |
| UV Wavelength Range | 280–400 nm (full-spectrum |
| Chamber Internal Dimensions (L×W×H) | 900 × 600 × 500 mm (540 L) |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | DV-540L |
| Humidity Range | ≥95% RH (in-chamber actual) |
| UV Lamp Power | 40 W per tube |
| Irradiance Range | 0.72 W/m² |
| Exposure Time Setting | 1–9999 h (adjustable) |
| Light Temperature Range | RT+10°C to 80°C (adjustable) |
| Black Panel Temperature Range | 40°C to 80°C (adjustable) |
| UV Wavelength Range | 280–400 nm (full-spectrum or single-band customizable) |
| Chamber Dimensions (L×W×H) | 900 × 600 × 500 mm (540 L internal volume) |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DV-UV340 Series |
| Price Range | USD 700 – 7,000 (FOB Shanghai) |
| Humidity Range | ≥95% RH (in-chamber actual value) |
| Lamp Power | 40 W per tube |
| Irradiance Range | 0.72 W/m² (at 340 nm) |
| Exposure Time Setting | 1–9999 hours (adjustable) |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Electronic Components UV Aging Test Chamber |
| Price Range | USD 900 – 9,000 (FOB Shanghai) |
| Humidity Range | ≥95% RH |
| UV Lamp Power | 40 W per lamp |
| Irradiance Range | 0.72 W/m² (at specimen surface, 340 nm nominal peak) |
| Test Duration | 1–9999 hours, programmable |