| Brand | Along |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | AL-WJ-0902 |
| Voltage Range | 20–225 kV |
| Current Range | 0–3 mA |
| Focal Spot Sizes | 1 µm, 5 µm, 30 µm |
| System Resolution | 70 LP/cm |
| Maximum Geometric Magnification | 5000× |
| Motion Axes | Motorized X-Y-Z Translation Stages |
| Sample Compatibility | BGA/CSP/Flip-Chip, PCB Assemblies, Li-ion Batteries, IC Packages, Passive Components, Metallic & Dielectric Materials, Lightweight Composites, Heating Elements, Pearls, Precision Mechanical Assemblies |
| Brand | Along |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | JF-2000 |
| Pricing | Available Upon Request |
| Brand | Along |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TX-160 |
| Voltage Range | 10–160 kV / 10–225 kV |
| Current Range | 0.1–1.0 mA |
| Beam Divergence Angle | ~160° |
| Max. Output Power | 60 W |
| Standard Target Power | 10 W |
| Focal Spot Size | <1 µm |
| Focus-to-Object Distance (FOD) | 0.25 mm |
| Geometric Magnification | up to 2800× |
| Filament Material | Tungsten |
| Vacuum System | Dual-Stage High/Low Vacuum Pump |
| Optional Accessories | High-Voltage Generator, HV Cable, X-ray Tube Controller |
| Brand | Along |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XXG-3005ZH, XXG-2505ZH |
| Power Supply | 220 V ±10% |
| Input Power | 3.5 kW |
| High Voltage Range | 50–300 kV (continuously adjustable) |
| Tube Current Range | 1–5 mA |
| Max. Penetration Thickness (A3 steel) | 60 mm |
| Film Density | D = 2.0 ± 0.1 |
| Cooling Method | Forced Air Cooling |
| Brand | Along |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | XXG-3005ZH |
| Voltage Range | 50–300 kV |
| Current Range | 1–5 mA |
| Focal Spot Size | 2.5 × 2.5 mm |
| Radiation Beam Angle | 40° ± 5° |
| Duty Cycle | 1:1 (Continuous Operation Mode) |
| Max. Penetration in A3 Steel | 50 mm |
| Generator Weight | 28 kg |
| Generator Dimensions | 345 × 345 × 670 mm |
| Brand | Along |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Model Series | YX-2, YX-200, YX-2H8, YX-300, YX-2A, YX-2B |
| X-ray Tube | Cu anode, air-cooled, 30 kV, 0–5 mA |
| Detector | Geiger-Müller counter |
| Angular Range | θ = −10° to +50°, 2θ = −10° to +100° |
| Angular Resolution | 10 arcseconds (digital display) |
| Accuracy | ±30″ (YX-2, YX-2H8, YX-2A left channel), ±10″ (YX-200, YX-300, YX-2A/YX-2B right channel), ±3″ or ±1″ (YX-300 & YX-2B right channel, min. readout) |
| Slit Options | 4′, 5′, 6′ |
| Time Constants | 0.1 s, 0.4 s, 3 s |
| Power Supply | 220 V AC, 50 Hz, 0.3 kW |
| Dimensions (L×W×H) | 1140–1150 mm × 650–665 mm × 1030–1100 mm |
| Weight | 150–170 kg |