X-ray Radiographic Inspection Systems and Accelerators
Filter
Showing 1–30 of 56 results
| Brand | Along |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TX-160 |
| Voltage Range | 10–160 kV / 10–225 kV |
| Current Range | 0.1–1.0 mA |
| Beam Divergence Angle | ~160° |
| Max. Output Power | 60 W |
| Standard Target Power | 10 W |
| Focal Spot Size | <1 µm |
| Focus-to-Object Distance (FOD) | 0.25 mm |
| Geometric Magnification | up to 2800× |
| Filament Material | Tungsten |
| Vacuum System | Dual-Stage High/Low Vacuum Pump |
| Optional Accessories | High-Voltage Generator, HV Cable, X-ray Tube Controller |
| Brand | Along |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XXG-3005ZH, XXG-2505ZH |
| Power Supply | 220 V ±10% |
| Input Power | 3.5 kW |
| High Voltage Range | 50–300 kV (continuously adjustable) |
| Tube Current Range | 1–5 mA |
| Max. Penetration Thickness (A3 steel) | 60 mm |
| Film Density | D = 2.0 ± 0.1 |
| Cooling Method | Forced Air Cooling |
| Brand | Along |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | XXG-3005ZH |
| Voltage Range | 50–300 kV |
| Current Range | 1–5 mA |
| Focal Spot Size | 2.5 × 2.5 mm |
| Radiation Beam Angle | 40° ± 5° |
| Duty Cycle | 1:1 (Continuous Operation Mode) |
| Max. Penetration in A3 Steel | 50 mm |
| Generator Weight | 28 kg |
| Generator Dimensions | 345 × 345 × 670 mm |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | AL-DR-270A |
| Price Range | USD 140,000 – 280,000 |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | AL-DR-300B |
| Price Range | USD 140,000 – 280,000 |
| Max. X-ray Energy | 350 kV |
| Tube Current | 5 mA |
| Focal Spot Size | 2.0 mm |
| Beam Divergence Angle | 40° |
| Sensitivity | ≤1.5% |
| Detector Type | Amorphous Silicon (a-Si), Custom-Optimized for Variable-Frequency X-ray Source |
| Active Imaging Area | 35 × 21 cm |
| Pixel Pitch | 140 µm |
| Spatial Resolution | 3.2 LP/mm |
| A/D Conversion | 16-bit |
| Image Acquisition Time | 1 s (wired), 2.5 s (wireless) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | AL-DR-300C |
| Configuration | Portable |
| Beam Directionality | Directional |
| Focal Spot Size | 2.5 mm |
| Radiation Angle | 40° + 5° (Total Coverage: 45°) |
| Maximum Penetration | 60 mm Fe-equivalent |
| Max. Tube Voltage | 320 kV |
| Tube Current | 5 mA |
| Detector Type | Amorphous Silicon (a-Si) Flat Panel Detector (Custom-optimized for Variable-Frequency X-ray Source) |
| Active Detector Area | 13 cm × 13 cm |
| Pixel Pitch | 85 µm |
| Spatial Resolution | 4 LP/mm |
| A/D Conversion | 16-bit |
| Sensitivity | ≤1.5% (EN 13297:2011 compliant) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | AL-DR-80 |
| Price Range | USD 140,000 – 280,000 |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Producer |
| Country of Origin | China |
| Model | AL-GB-1306 |
| Voltage Range | 30–130 kV |
| Current Range | 0.1–0.6 mA |
| Operating Frequency | 20 kHz |
| Duty Cycle | 1:1 (Continuous/Intermittent) |
| Dimensions | Ø225 × 785 mm |
| Weight | 23 kg |
| Application | Tube-to-Tubesheet Weld Inspection |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AL-NP-6010A |
| Price Range | USD 280,000 – 425,000 |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Dual-Polarity 320kV/450kV |
| Price Range | USD $27,000 – $68,000 |
| Controller Weight | 12 kg |
| Cathode HV Generator Weight | 70 kg |
| Anode HV Generator Weight | 70 kg |
| Oil-Free Water Cooler Weight | 40 kg |
| Controller Dimensions (L×W×H) | 410 × 500 × 250 mm |
| Cathode Generator Dimensions | 720 × 360 × 450 mm |
| Anode Generator Dimensions | 720 × 360 × 450 mm |
| Oil Cooler Dimensions | 442 × 423 × 685 mm |
| Input Voltage | 220 VAC ±10% |
| Input Frequency | 50 Hz ±2% |
| Input Power | ≥5 kW |
| Output Voltage Range | 20–450 kV |
| Output Current | 30 mA |
| kV Adjustment Resolution | 1 kV |
| mA Adjustment Resolution | 0.1 mA |
| Duty Cycle | Continuous |
| Generator Frequency | 40 Hz |
| H225 Generator Max Output | −225 kV (cathode), +225 kV (anode) |
| H225 Max Power | 3 kW |
| Insulation Medium | Oil |
| Cooler Model | AL-YLB-4500 |
| Controller | T7000 with Color Touchscreen, Chinese UI, EMI-Resistant Architecture, Auto-Training Function, Programmable Exposure Sequencing, Lead-Door Interlock, Safety Key Switch, Timer Range: 0.1–99.8 min (99.9 min = continuous mode) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MF-2505 |
| Price Range | USD 14,000–28,000 |
| Input Voltage | 220 V ±10% |
| Input Power | 3.5 kW |
| Tube Voltage Range | 50–250 kV (continuously adjustable) |
| Tube Current | 5 mA |
| Max. Penetration Thickness (A3 steel) | 48 mm |
| Film Density | D = 1.5 ±0.1 |
| Cooling Method | Forced Air Cooling |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Microfocus X-ray Industrial CT |
| Price Range | USD 140,000 – 280,000 (FOB) |
| Configuration | Fixed or Mobile |
| Beam Geometry | Directional |
| Minimum Focal Spot Size | 2 µm |
| Radiation Cone Angle | 30° |
| Maximum Penetration | 40 mm Al-equivalent |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China-made) |
| Model | Single-Polarity |
| Price Range | USD 28,000 – 70,000 |
| Weight | Controller — 12 kg |
| Dimensions (L×W×H) | Controller — 410 × 500 × 250 mm |
| Input Voltage | 220 VAC ±10% |
| Frequency | 50 Hz ±2% |
| Input Power | ≥5 kW |
| Output Voltage Range | 20–225 kV |
| Output Current | 30 mA |
| kV Adjustment Resolution | 1 kV |
| mA Adjustment Resolution | 0.1 mA |
| Operating Duty Cycle | Continuous |
| Generator Frequency | 40 Hz |
| Max. HV Generator Output | −225 kV (cathode), 30 mA, 3 kW |
| Insulation Method | Oil-immersed |
| Cooling | Forced water cooling (AL-ZFB-3000 cooler) |
| Control Interface | T7000 color touchscreen controller with Chinese GUI, EMI-hardened design, programmable exposure parameters, automatic tube conditioning, real-time exposure logging, and interlocked lead-shielded door safety system |
| Exposure Timer Range | 0.1–99.8 min (99.9 min = continuous mode) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | MXV100 |
| Price | ¥190,000 |
| X-ray Generator Input Voltage | 1-phase 230 VAC |
| Output Power | 32 kW |
| Operating Frequency | 400 kHz |
| Tube Voltage Range | 40–150 kV (1 kV step) |
| Tube Current Range | 20–400 mA |
| mAs Range | 0.1–500 mAs |
| Exposure Time Range | 1–6300 ms |
| Focal Spot Size | 0.6 / 1.2 mm |
| Anode Heat Capacity | 150 kHU (111 kJ) |
| Anode Target Angle | 12° |
| Animal Table Dimensions | 120 × 60 × 90 cm (L×W×H) |
| Table Material | Carbon Fiber |
| Collimator Field Size (max) | 48 × 48 cm at SID = 100 cm |
| Light Field Duration | 60 s |
| Laser Pointer | Crosshair type |
| Collimator Adjustment | Manual knob |
| Grid Size | 17″ × 17″ (43 × 43 cm) |
| Grid Ratio | 8:1 |
| Grid Line Density | 103 lines/inch |
| Grid Focus Distance | 100 cm |
| Arm Vertical Travel | 74.5 cm |
| Arm Horizontal Travel | 50 cm |
| Tube Rotation Angle | ±90° |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Portable X-ray DR Imaging System |
| Price Range | USD 140,000 – 280,000 |
| X-ray Tube Voltage | 160 kV (120 kV optional) |
| X-ray Tube Current | up to 5 mA |
| System Weight | 10 kg |
| Operating Temperature | −20 °C to +60 °C |
| Image Area | 130 mm × 130 mm |
| Pixel Pitch | 85 µm |
| Spatial Resolution | 4.0 line pairs/mm |
| Core Components | X-ray generator, flat-panel detector (indirect conversion), ruggedized laptop workstation |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Standard |
| Price Range | USD 28,000 – 70,000 |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | T4776, T4777 |
| Price Range | USD 28,000 – 70,000 |
| Power Supply | 50 Hz AC 220 V ±10% |
| Input Power | 3.5 kW (generator ≥5 kW required) |
| Tube Voltage | Continuously Adjustable |
| Tube Voltage Stability | ±1% |
| Tube Current | 5 mA |
| Duty Cycle | 1:1 (continuous operation mode) |
| Cooling Method | Forced Air Cooling |
| Operating Ambient Temperature | −30 °C to +40 °C |
| Focal Spot-to-Film Distance | 600 mm |
| Controller Weight | 10 kg |
| Film Density | D ≥ 1.5 |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | T5777 |
| Price Range | USD 28,000 – 71,000 |
| Power Supply | 220 V ±10% |
| Input Power | 3.5 kW |
| High Voltage Range | 100–300 kV |
| Tube Current Range | 1–5 mA |
| Max Penetration Thickness (A3 Steel) | 48 mm |
| Film Density | D = 1.5 ±0.1 |
| Cooling Method | Forced Air Cooling |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | T6777 |
| Price | Upon Request |
| Input Power | 3 kW |
| Input Voltage | 220 V AC ±10%, 50 Hz |
| Tube Voltage Range | Continuously Adjustable |
| Tube Voltage Stability | ±1% |
| Tube Current Range | 1–3 mA, Continuously Adjustable |
| Operating Mode | 1:1 Duty Cycle |
| Cooling Method | Forced Air Cooling |
| Operating Ambient Temperature | −30 °C to +40 °C |
| Source-to-Film Distance (SFD) | 600 mm |
| Controller Weight | 8 kg |
| Radiographic Film Density | D ≥ 1.5 |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | X-Ray Multi-Function Automated Positioning Trolley |
| Price Range | USD 28,000 – 70,000 |
| Max. Vertical Travel | 3 m / 5 m (selectable) |
| Motion Axes | 4-axis motorized (X/Y/Z + rotational tilt) |
| X-ray Tube Mount Compatibility | Universal interface for portable X-ray sources (ISO 10962-compliant flange dimensions) |
| Control | Integrated touchscreen HMI with programmable motion presets and emergency stop circuitry |
| Safety Compliance | Meets GB/T 18871-2002 (Chinese radiation protection standard), IEC 61000-6-4 EMC immunity |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | X-Ray Pipeline Crawler |
| Price Range | USD 28,000 – 70,000 |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | Radiographic Film-based NDT System |
| Price Range | USD 0 – 14,500 (FOB) |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (PRC) |
| Model | Laser Positioning Device for X-ray Radiographic Inspection Systems |
| Price Range | USD 28,000 – 70,000 |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | YX-2C |
| Price Range | USD 140,000 – 280,000 |
| Input Power | AC 220 V, 50 Hz, 0.5 kW |
| X-ray Tube | Cu anode, air-cooled, 30 kV, 0–5 mA |
| Detector | Geiger–Müller counter |
| Time Constants | 0.1 s, 0.4 s, 3 s |
| Angular Range | θ = −5° to +55°, 2θ = −10° to +110° |
| Mechanical Angular Resolution | 1° (on scale ring for both θ and 2θ) |
| Digital Display Resolution | 10 arcseconds |
| Angular Accuracy | ±30 arcseconds |
| Slit Apertures | 4′, 5′, 6′ |
| Beam Shutter | Manual |
| Display Format | Degrees, Minutes, Seconds |
| Angle Setting | Programmable digital angle preset |
| Dimensions (L×W×H) | 1140 × 650 × 1030 mm |
| Weight | 150 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YX-2H8A |
| Price Range | USD 2,800 – 14,000 |
| Input Power | 220 V AC, 50 Hz, 0.5 kW |
| X-ray Tube | Cu anode, air-cooled, 30 kV, 0–5 mA |
| Detector | Geiger-Müller counter |
| Time Constants | 0.1 s, 0.4 s, 3 s |
| Angular Range | θ = −5° to +55°, 2θ = −10° to +110° |
| Angular Resolution | 1 arcsecond (1″) |
| Minimum Scale Reading | 1° on mechanical scale (2θ and θ) |
| Digital Display | Degrees, minutes, seconds |
| Adjustable Angle Setting | Programmable digital angle positioning |
| Collimator Slits | 4′, 5′, 6′ |
| Beam Shutter | Manual |
| Display Type | Digital angular readout |
| Overall Angular Accuracy | ±30″ |
| Dimensions (L×W×H) | 1160 × 700 × 1380 mm |
| Weight | 170 kg |
| Key | Brand: Aolong |
|---|---|
| Model | ZFB-3000 |
| Cooling Output | 3 kW |
| Circulation Flow Rate | >6 L/min |
| Set Flow Rate | 4 L/min |
| Temperature Setpoint | 40 °C |
| Power Supply | 220 V ±10%, 50/60 Hz, Single-phase |
| Current Draw | ≤2.3 A |
| Noise Level | 58 dB(A) at 1 m |
| Reservoir Volume | 4.0 L |
| Coolant | Deionized Water |
| Pump | PROCON (USA) Vane-type Pump |
| Heat Exchanger | High-efficiency Finned-tube Radiator |
| Temperature Controller | OMRON (Japan) Digital PID Controller |
| X-ray Tube Voltage Range | 160–225 kV |
| Origin | Liaoning, China |
| Manufacturer Type | OEM Producer |
| Brand | Aolong |
|---|---|
| Cooling Capacity | 4000 W |
| Flow Rate | 14 L/min |
| Power Supply | Single-phase 220 V ±10%, 50/60 Hz |
| Current Draw | 2.3 A |
| Noise Level | 58 dB(A) at 1 m |
| Operating Temperature | +5 °C to +35 °C |
| Storage Temperature | −25 °C to +70 °C (oil-free) |
| Relative Humidity | 20–80% RH (non-condensing) |
| Maximum System Pressure | 60 bar |
| Origin | Liaoning, China |
| Manufacturer | Aolong (OEM producer) |
| Brand | ASIDA |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ASIDA 5000 Series |
| Pricing | Upon Request |
| X-ray Tube Voltage | ≤110 kV |
| X-ray Tube Current | ≤450 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Flat Panel Detector Active Area | 54 mm × 48 mm |
| Spatial Resolution | 20.8 lp/mm |
| Image Resolution Options | 2000 × 2249 px or 1000 × 1124 px |
| Repeatability Accuracy | ±60 µm |
| Throughput | ≥50 parts per minute (ppm) |
| False Positive Rate | ≤2% |
| Miss Detection Rate | 0.0% |
| Overall Yield Assurance | ≥99.5% |
| Radiation Leakage | ≤1 µSv/hr (compliant with IEC 61331-1 and ISO 15708-2) |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | XG5000 |
| Pricing | Upon Request |
| Brand | ASIDA |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ASIDA XG5130A |
| Price | Upon Request |
| X-ray Tube Voltage | ≤90 kV |
| X-ray Tube Current | ≤89 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Image Intensifier Field of View | 2″ / 4″ |
| Spatial Resolution | 75 / 110 lp/cm |
| X-CCD Resolution | 752 × 480 pixels |
| Repeatability Accuracy | ±60 µm |
| Throughput | ≥30 ppm (≥1,800 units/hour, ≥30,000 units/shift) |
| False Positive Rate | ≤2% |
| Miss Detection Rate | 0% |
| Pass Rate Consistency | ≥99.5% |
| Radiation Leakage | ≤1 µSv/hr (compliant with IEC 61000-6-4, IEC 62471, and GBZ 138–2019) |