Analytik Jena
Filter
Showing 1–30 of 80 results
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Category | Imported Instrument |
| Model | Biometra TAdvanced 384G |
| Throughput | 384-well format |
| Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Fast PCR Cycler |
| Sample Capacity | 96-well (0.2 mL tubes, 96-well plates, or 12×8 strip tubes) |
| Max Heating Rate | 6.0 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ±0.2 °C |
| Gradient Span | 0.1–30.0 °C (linear, per column) |
| Gradient Range | 20–99 °C |
| Block Temp Range | 3–99 °C |
| Lid Temp Range | 30–110 °C |
| Display | 7″ capacitive color touchscreen |
| Noise Level | ≤45 dB(A) |
| Power Consumption | 850 W |
| Dimensions (W×H×D) | 277 × 264 × 457 mm |
| Weight | 15 kg |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Type | Fast PCR Thermal Cycler |
| Model | Biometra TAdvanced 96 SG |
| Sample Capacity | 96-well format (standard 96-well plates, 0.2 mL tubes, or 8-tube strips) |
| Max Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ±0.15 °C |
| Gradient Span | up to 40 °C across 12 columns |
| Gradient Modes | Linear and Random |
| Block Material | Gold-plated pure silver thermal block |
| Heat Lid | High-Performance Smart Lid (HPSL), pressure-regulated, max lid temperature 110 °C |
| User Management | Three-tier Advanced User Management (AUM) with password protection |
| Software Interface | Dual-view program editor (tabular & graphical), intelligent protocol builder, preloaded templates |
| Compliance Features | Built-in self-diagnostic suite with audit-trail-capable log storage, GLP-compliant operation |
| Operating Noise | ≤45 dB(A) |
| Cooling Method | Bottom-intake / rear-exhaust airflow design |
| Touchscreen | Full-color capacitive touchscreen, glove-compatible |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Biometra TAdvanced 96SG |
| Pricing | Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Gradient PCR Instrument |
| Model | Biometra TAdvanced Twin 48G |
| Sample Capacity | 48 × 2 wells (dual independent blocks) |
| Heating Rate | 5.2 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Inter-well Temperature Uniformity | ±0.2 °C |
| Gradient Range | Linear gradient across 8 rows (LGT) |
| Thermal Sensor | PT100 (Swiss-made, 25-year heritage) |
| Noise Level | ≤45 dB(A) |
| Lid Pressure Control | High-Performance Smart Lid (HPSL) with clutch-based constant-force mechanism |
| User Management | Three-tier Advanced User Management (AUM) with password protection and role-specific permissions |
| Software Features | Intelligent Protocol Assistant (IPA), built-in self-diagnostic suite (thermal ramping, lid function, gradient validation), glove-compatible capacitive touchscreen display |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Type | Gradient PCR Instrument |
| Sample Capacity | 96-well format |
| Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.2 °C |
| Gradient Configuration | 12-column linear or randomized gradient profiles |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported Instrument |
| Model | Biometra TRIO 48 |
| Sample Throughput | 144 wells (3 × 48-well blocks) |
| Heating Rate | 5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Block Uniformity | ±0.2 °C across block |
| Display | 7-inch full-color capacitive touchscreen |
| Power Recovery | Auto-resume after power interruption |
| Tube Compatibility | Standard 0.2 mL tubes and 8-tube strips |
| Cooling Method | Passive air cooling with bottom intake / rear exhaust airflow |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Biometra TRobot II |
| Instrument Type | Fast-cycle PCR System |
| Sample Throughput | 96-well or 384-well format |
| Heating Rate | 5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.5 °C |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Category | Imported |
| Models | Compact XS, Compact S, Compact M, Compact L, Compact XL |
| Pricing | Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical System | Dual-Beam |
| Monochromator | Echelle Grating with Quartz Prism Cross-Disperser |
| Detector | Solid-State CCD Array |
| Background Correction | Real-Time, Multi-Wavelength Simultaneous Correction |
| Wavelength Resolution | 0.002 nm |
| Light Source | High-Intensity Short-Arc Xenon Lamp (Continuum Source) |
| Measurement Mode | Sequential Multi-Element & Full-Spectrum Acquisition |
| Dynamic Linear Range | 5 Orders of Magnitude |
| Software Compliance | FDA 21 CFR Part 11 Ready, GLP/GMP Audit Trail Enabled |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | contrAA 800 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Wavelength Range | 185–900 nm |
| Light Source | High-Intensity Short-Arc Xenon Lamp |
| Detection Principle | High-Resolution Continuum Source AAS (HR-CS AAS) |
| Detector | CCD Array |
| Background Correction | Automatic Background Correction (ABC) and Concurrent Spectrum Interference Correction (CSI) |
| Detection Limit | Sub-ppb for most elements |
| Elemental Coverage | Simultaneous multi-element analysis across full UV-VIS-NIR range |
| Atomization Modes | Integrated flame and electrothermal (graphite furnace) atomization |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported |
| Model | Cybi-FeliX |
| Pricing | Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Country of Origin | Germany |
| Model | Cybi-Well Vario |
| Pipetting Heads | 9 interchangeable heads (96-channel, 384-channel, 1536-channel, capillary) |
| Volume Range | 25 nL – 250 µL (wet & dry) |
| Precision | CV ≤ 1–7% depending on volume and head |
| Plate Formats Supported | 96-, 384-, and 1536-well microplates (shallow & deep well) |
| Carrier Options | 3-, 4-, 5-, or 10-plate carriers |
| Tip Types | Disposable plastic tips, ceramic tips, glass capillaries |
| Software | CyBi-Composer with auto-head recognition and GLP-compliant audit trail |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported |
| Models | Eco-Mini, Eco-Maxi |
| Pricing | Upon Request |
| Gel Dimensions (Eco-Mini) | 9.4 × 8.0 cm |
| Gel Dimensions (Eco-Maxi) | 19.4 × 18.5 cm |
| Glass Plate Dimensions (Eco-Mini) | 11.0 × 10.0 cm |
| Glass Plate Dimensions (Eco-Maxi) | 21.0 × 20.0 cm |
| Max. Gels per Run | 2 |
| Comb Thickness Options | 0.75 mm, 1.0 mm, 1.5 mm |
| Comb Tooth Counts | 9–30 (Eco-Mini), 12–60 (Eco-Maxi) |
| Sample Capacity | Up to 30 wells (Eco-Mini), up to 60 wells (Eco-Maxi) |
| Well Volume Range | 15–165 µL |
| Buffer Volume (Eco-Mini) | 1580 mL (electrophoresis), 2180 mL (blotting) |
| Buffer Volume (Eco-Maxi) | 5400 mL (electrophoresis), 6100 mL (blotting) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | Eco-Mini and Eco-Maxi |
| Instrument Type | Wet Transfer Electrophoresis System |
| Gel Dimensions | 8 × 7 cm |
| Sample Capacity | 10-well comb (single gel) or 20-well comb (dual gels) |
| Voltage/Current Range | 0–300 V / 0–400 mA |
| External Dimensions | 15 × 12 × 20 cm |
| Glass Plate Thickness | 3 mm |
| Optional | Integrated Cooling Circulation Unit |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ICprep |
| Measurement Elements | F, Cl, Br, I, S |
| Analysis Time | 3–4 min per sample |
| Sample Introduction | Up to 100 µL for liquids, up to 110 mg for solids |
| Combustion Temperature | Up to 1100 °C |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Country of Origin | Imported |
| Model | MobiLab2 |
| Price | Upon Request |
| Dimensions | 560 × 220 × 350 mm (W × H × D) |
| Weight | 25 kg |
| Power Supply | AC adapter or integrated high-capacity rechargeable battery |
| Sample Throughput | 9 samples or 9 assays simultaneously |
| Thermal Block Temperature Range | 4 °C – 105 °C |
| PCR Module Temperature Uniformity | ±0.3 °C |
| PCR Module Temperature Accuracy | ±0.2 °C |
| Heating/Cooling Module | High-efficiency, long-life Peltier elements |
| Incubation & Shaking | 25–100 °C, up to 1400 rpm |
| Detection Method | RAH (Rapid Amplification and Hybridization) coupled with lateral flow immunoassay (LFIA) |
| Readout Format | Visual interpretation of dual-line lateral flow strips (control + test bands) in sealed reaction chambers |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Type | Imported Instrument |
| Model | multi EA 4000 |
| Measurement Principle | Infrared Absorption (CO₂, SO₂, HCl detection) |
| Heating System | High-Temperature Ceramic Furnace (HTC) |
| Sample Form | Solid and viscous samples |
| Modular Configuration | Independent C, S, Cl analysis modules |
| Compliance | ASTM D4293, ASTM D5178, ISO 20565, DIN 51721, EN 15408, EPA Method 9096A (for AOX), USP <281> (for residual chlorine) |
| Software | multiWin v5.x with 21 CFR Part 11 compliance options |
| Safety | Integrated Self-Check System (SCS), automatic gas leak detection, overpressure protection |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi EA 5010 |
| Detection Principle | Chemiluminescence (N) / UV Fluorescence (S) with MPO High-Nitrogen Interference Compensation |
| LOD (N) | 10 ppb |
| LOD (S) | 5 ppb |
| Linear Range (S) | up to 10,000 mg/kg |
| Analysis Time | 2–5 min per sample |
| Compliance | ASTM D5453, D7183, ISO 20846, ISO 29189, GB/T 17040, GB/T 17674, USP <233>, EPA Method 1664A (adapted), GLP/GMP-ready |
| Automation | Fully automated calibration, parameter optimization, and continuous unattended operation |
| Footprint | < 0.3 m² |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | multi EA 5010 |
| Pricing | Available Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | multi EA 5010 |
| Price | Upon Request |
| Detector | HiPerSens UV Fluorescence & Chemiluminescence Detector |
| Measurement Range | 0.0x ppm to 100% (w/w or v/v) |
| Sample Volume | Liquids: 50 µL |
| Gases | 20 mL |
| Combustion Furnace Temperature | Up to 1100 °C |
| Compliance | ASTM D5453, D7183, D7039, ISO 20846, ISO 20884, UOP 97, IP 433, IP 541, EN 15486 |
| Software | multiWin v5.x with 21 CFR Part 11 compliance modules |
| Connectivity | Ethernet, LIMS-ready, Remote Web Access via Browser or Mobile App |
| Safety | Automated Self-Check, Real-Time Parameter Monitoring, Push Notification Alert System |
| Brand | analytik jena |
|---|---|
| Origin | Germany |
| Model | multi EA 5100 |
| Detection Elements | C, N, S, Cl |
| Furnace Configurations | Dual-mode vertical & horizontal combustion furnace |
| Detector Technology | HiPerSens® electrochemical and thermal conductivity detection |
| Sample Forms | Solid, liquid, gaseous & supercritical fluid |
| Automation | Fully automated direct injection |
| Compliance | Designed for GLP/GMP environments |
| Safety Systems | Integrated self-diagnostic module, flame sensor (horizontal mode), aerosol/liquid ingress protection, auto-leak monitoring, active gas stream drying & purification |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported Instrument |
| Model | multi EA 5100 |
| Pricing | Available Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | multi EA H 5000 |
| Price Range | USD 68,000 – 109,000 |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported Instrument |
| Model | multi EA S 5000 |
| Measurement Principle | Infrared Absorption (for C), Chemiluminescence (for N), UV Fluorescence or Microcoulometric Detection (for S), Microcoulometric Detection (for Cl) |
| Furnace System | Dual-mode resistive furnace (vertical/horizontal configuration) |
| Detection Limit | ppb-level |
| Measurement Range | ppb to wt% |
| Accuracy | ±0.01 ppm |
| Analysis Time | 2–4 minutes |
| Maximum Furnace Temperature | 1100 °C |
| Liquid Sample Volume | 1–100 µL |
| Gas Sample Volume | up to 100 mL |
| Solid Sample Mass | up to 100 mg |
| LPG Sample Volume | 1–50 µL |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH & Co. KG |
| Type | Imported Instrument |
| Model | multi EA® 5000 |
| Detection Principles | Chemiluminescence (N), UV Fluorescence or Microcoulometry (S), Microcoulometry (Cl), NDIR (C) |
| Furnace Configuration | Dual-mode vertical/horizontal high-temperature combustion furnace (up to 1100 °C) |
| Sample Forms | Liquid (1–100 µL), Gas (up to 100 mL), LPG (1–50 µL), Solid (up to 100 mg) |
| Detection Range | 0.0x ppm to % level |
| Automatic Mode Recognition | Yes |
| Flame Monitoring Sensor | Integrated real-time combustion state feedback |
| Gas Pressure Tolerance | 0.2–0.6 MPa (O₂), with under/over-pressure alarm |
| Calibration | Single calibration curve applicable across full dynamic range |
| Compliance | Designed for GLP/GMP environments |
| Brand | analytik jena |
|---|---|
| Origin | Germany |
| Manufacturer | analytik jena GmbH |
| Product Type | Laboratory TOC/TN Analyzer |
| Model | multi N/C ® Pharma UV |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Wet Oxidation |
| Measurement Range | 0–10,000 ppm C or N |
| Accuracy | ±3% |
| Resolution | 0.001 ppb |
| Detection Limit | 2 ppb |
| Repeatability | <3% |
| Compliance | Designed for USP <643>, EP 2.2.44, JP 17, FDA 21 CFR Part 11, and GMP/GLP environments |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Type | Laboratory TOC/TN Analyzer |
| Model | multi N/C 2100 |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion (up to 1000 °C) |
| Measurement Range | 0–60,000 ppm C or N |
| Accuracy | ≤ 3.0% RSD @ 100 mg/L TOC |
| Detection Limit | 50 ppb TOC |
| Resolution | 0.001 ppb |
| Repeatability | ≤ 2.0% RSD @ 100 mg/L TOC |
| Compliance | ASTM D7573, ISO 8245, USP <643>, EN 1484, EPA Method 415.3 & 9060A |
| Software | ASpect® TOC/TN Control & Data Management Suite (21 CFR Part 11 compliant) |
| Brand | Analytik Jena |
|---|---|
| Model | multi N/C 2100 |
| Origin | Germany (manufactured), assembled/integrated in Beijing, China |
| Condition | Refurbished & fully functional |
| Operational Age | <5 years |
| Detection Principle | High-temperature catalytic oxidation + NDIR for TOC |
| TOC Range | 0–30,000 ppm (liquid), up to 150 mg C (solid) |
| TN Range | 0–300 ppm |
| TOC LOD | 50 ppt |
| TN LOD | 50 ppb |
| Oxidation Temp | up to 1,000 °C (liquid), up to 1,500 °C (solid) |
| Injection Volume | 0.01–0.5 mL |
| Precision | ≤2.0% RSD at 100 mg/L TOC |
| Resolution | 0.001 ppb |
| Salt Tolerance | ≤85 g/L |
| Particle Size Limit | ≤630 µm |
| Software | multiWin v4.x (GLP-compliant, audit trail enabled) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi N/C 2100S / 3100 |
| Instrument Type | Laboratory TOC/TNb Analyzer |
| Detection Principle | High-Temperature Catalytic Combustion (up to 1000 °C) and Dual-Wavelength UV Oxidation (185/254 nm) |
| CO₂ Detection | Focused NDIR with Integrated Optics |
| TOC Range | 0–30,000 mg/L (without dilution) |
| Compliance | ASTM D7573, ISO 8245, USP <643>, EN 1484, EPA Method 415.3 & 9060A, DIN 38409-H3 |