Analytik Jena
Filter
Showing 31–60 of 96 results
| Brand | analytik jena |
|---|---|
| Origin | Germany |
| Model | multi EA 5100 |
| Detection Elements | C, N, S, Cl |
| Furnace Configurations | Dual-mode vertical & horizontal combustion furnace |
| Detector Technology | HiPerSens® electrochemical and thermal conductivity detection |
| Sample Forms | Solid, liquid, gaseous & supercritical fluid |
| Automation | Fully automated direct injection |
| Compliance | Designed for GLP/GMP environments |
| Safety Systems | Integrated self-diagnostic module, flame sensor (horizontal mode), aerosol/liquid ingress protection, auto-leak monitoring, active gas stream drying & purification |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported Instrument |
| Model | multi EA 5100 |
| Pricing | Available Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | multi EA H 5000 |
| Price Range | USD 68,000 – 109,000 |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported Instrument |
| Model | multi EA S 5000 |
| Measurement Principle | Infrared Absorption (for C), Chemiluminescence (for N), UV Fluorescence or Microcoulometric Detection (for S), Microcoulometric Detection (for Cl) |
| Furnace System | Dual-mode resistive furnace (vertical/horizontal configuration) |
| Detection Limit | ppb-level |
| Measurement Range | ppb to wt% |
| Accuracy | ±0.01 ppm |
| Analysis Time | 2–4 minutes |
| Maximum Furnace Temperature | 1100 °C |
| Liquid Sample Volume | 1–100 µL |
| Gas Sample Volume | up to 100 mL |
| Solid Sample Mass | up to 100 mg |
| LPG Sample Volume | 1–50 µL |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH & Co. KG |
| Type | Imported Instrument |
| Model | multi EA® 5000 |
| Detection Principles | Chemiluminescence (N), UV Fluorescence or Microcoulometry (S), Microcoulometry (Cl), NDIR (C) |
| Furnace Configuration | Dual-mode vertical/horizontal high-temperature combustion furnace (up to 1100 °C) |
| Sample Forms | Liquid (1–100 µL), Gas (up to 100 mL), LPG (1–50 µL), Solid (up to 100 mg) |
| Detection Range | 0.0x ppm to % level |
| Automatic Mode Recognition | Yes |
| Flame Monitoring Sensor | Integrated real-time combustion state feedback |
| Gas Pressure Tolerance | 0.2–0.6 MPa (O₂), with under/over-pressure alarm |
| Calibration | Single calibration curve applicable across full dynamic range |
| Compliance | Designed for GLP/GMP environments |
| Brand | analytik jena |
|---|---|
| Origin | Germany |
| Manufacturer | analytik jena GmbH |
| Product Type | Laboratory TOC/TN Analyzer |
| Model | multi N/C ® Pharma UV |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Wet Oxidation |
| Measurement Range | 0–10,000 ppm C or N |
| Accuracy | ±3% |
| Resolution | 0.001 ppb |
| Detection Limit | 2 ppb |
| Repeatability | <3% |
| Compliance | Designed for USP <643>, EP 2.2.44, JP 17, FDA 21 CFR Part 11, and GMP/GLP environments |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Type | Laboratory TOC/TN Analyzer |
| Model | multi N/C 2100 |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion (up to 1000 °C) |
| Measurement Range | 0–60,000 ppm C or N |
| Accuracy | ≤ 3.0% RSD @ 100 mg/L TOC |
| Detection Limit | 50 ppb TOC |
| Resolution | 0.001 ppb |
| Repeatability | ≤ 2.0% RSD @ 100 mg/L TOC |
| Compliance | ASTM D7573, ISO 8245, USP <643>, EN 1484, EPA Method 415.3 & 9060A |
| Software | ASpect® TOC/TN Control & Data Management Suite (21 CFR Part 11 compliant) |
| Brand | Analytik Jena |
|---|---|
| Model | multi N/C 2100 |
| Origin | Germany (manufactured), assembled/integrated in Beijing, China |
| Condition | Refurbished & fully functional |
| Operational Age | <5 years |
| Detection Principle | High-temperature catalytic oxidation + NDIR for TOC |
| TOC Range | 0–30,000 ppm (liquid), up to 150 mg C (solid) |
| TN Range | 0–300 ppm |
| TOC LOD | 50 ppt |
| TN LOD | 50 ppb |
| Oxidation Temp | up to 1,000 °C (liquid), up to 1,500 °C (solid) |
| Injection Volume | 0.01–0.5 mL |
| Precision | ≤2.0% RSD at 100 mg/L TOC |
| Resolution | 0.001 ppb |
| Salt Tolerance | ≤85 g/L |
| Particle Size Limit | ≤630 µm |
| Software | multiWin v4.x (GLP-compliant, audit trail enabled) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi N/C 2100S / 3100 |
| Instrument Type | Laboratory TOC/TNb Analyzer |
| Detection Principle | High-Temperature Catalytic Combustion (up to 1000 °C) and Dual-Wavelength UV Oxidation (185/254 nm) |
| CO₂ Detection | Focused NDIR with Integrated Optics |
| TOC Range | 0–30,000 mg/L (without dilution) |
| Compliance | ASTM D7573, ISO 8245, USP <643>, EN 1484, EPA Method 415.3 & 9060A, DIN 38409-H3 |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi N/C 3100 |
| Instrument Type | Laboratory TOC/TN Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Measurement Range | 0–30,000 ppm C or N |
| Accuracy | ±2% of reading |
| Resolution | 0.001 ppb C |
| Detection Limit | 4 ppb C |
| Repeatability | ≤1% RSD |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Instrument Type | Laboratory TOC/TNb Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion (up to 1000 °C) |
| Optional Oxidation | Dual-Wavelength High-Intensity UV Photolysis (for wet chemical oxidation) |
| Detection Modules | NDIR for TOC/TC/TIC/NPOC/POC |
| Sample Introduction | Ceramic Valve-Based Loop Injection System |
| Sample Compatibility | Suspended-solids-rich wastewater, high-salinity matrices, ultrapure water, and solid samples (with optional solid module) |
| Automation Level | Fully Modular, Configurable for Unattended Operation |
| Compliance Support | Designed for GLP/GMP environments |
| Brand | analytik jena |
|---|---|
| Origin | Germany |
| Manufacturer | analytik jena GmbH |
| Country of Origin | Imported |
| Model | multi N/C Pharma HT |
| Instrument Type | Laboratory TOC/TN Analyzer |
| Detection Principle | Non-Dispersive Infrared Absorption (NDIR) for TOC |
| Oxidation Method | High-Temperature Catalytic Combustion at up to 1000 °C |
| Measurement Range | 0–10,000 ppm C or N |
| Accuracy | <3% RSD |
| Detection Limit | 4 ppb C |
| Resolution | 0.001 ppb C |
| Repeatability | ±3% RSD |
| Compliance | Designed for GLP/GMP environments |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi N/C UV HS |
| Instrument Type | Laboratory TOC/TNb Analyzer |
| Detection Principle | High-Energy UV/Persulfate Oxidation + NDIR CO₂ Detection |
| Measurement Range | 0–30,000 mg/L TOC |
| Detector | High-Focus NDIR |
| Oxidation | Dual-Wavelength UV (185 nm & 254 nm) + Optional Persulfate |
| Compliance | DIN EN 1484, DIN EN 12260, DIN EN 15936, ISO 20236, HJ 501-2009, HJ 695-2014, GB/T 5750.7-2006 |
| Brand | analytik jena |
|---|---|
| Origin | Germany |
| Manufacturer | analytik jena GmbH & Co. KG |
| Product Type | Laboratory TOC/TN Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Wet Oxidation |
| Measurement Range | 0–10,000 ppm C or N |
| Accuracy | ±2% of reading |
| Resolution | 0.001 ppb C |
| Detection Limit | 0.03 ppb – 10,000 ppm C |
| Repeatability | <1% RSD |
| Compliance | ASTM D5905, ISO 8245, USP <643>, EP 2.2.44, DIN 38409-H41 |
| Software | TOC-Control v4.x with 21 CFR Part 11 compliance options |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Country of Origin | Imported |
| Model | multi X 2500 |
| Price | Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Dual-Beam with Automatic Switching to Single-Beam |
| Detector | CCD Array (185–900 nm) |
| Background Correction | Automatic Deuterium/Halogen Lamp or Zeeman (software-selectable) |
| Spectral Resolution | ≤ 0.1 nm |
| Sensitivity | ≥ 0.9 A for 5 mg/L Cu solution (279.5 nm, air-acetylene flame) |
| Precision (RSD) | < 0.5% (n = 10, typical aqueous standards) |
| Detection Limit (Flame Mode) | < 0.005 mg/L Cu |
| Detection Limit (Graphite Furnace Mode) | Sub-pg range for Cd/Pb (e.g., < 3 pg for Cd) |
| Baseline Stability | < 0.002 A/h (typical, 24 h drift monitoring) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | novAA 800F |
| Atomization Type | Flame |
| Detector | SiOSens solid-state semiconductor detector |
| Lamp Holder | Integrated 8-position auto-rotating turret with coded lamp recognition |
| Background Correction | Deuterium arc lamp |
| Optical System | Switchable single-beam / double-beam / emission modes |
| Automation Level | Fully automated dual atomizer switching (flame/graphite/hydride), auto-optimization, programmable dilution & autosampling |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | P25/25T |
| Output Voltage Range | 0–400 V |
| Output Current Range | 0–1000 mA |
| Operating Modes | Constant Voltage (CV), Constant Current (CC), Auto-Mode Switching |
| Memory Function | Last-Used Parameter Retention (non-volatile) |
| Timer Range | 1 min – 99 hr 59 min |
| Output Terminals | 4 independent dual-terminal pairs (8 total banana jacks) |
| Compliance | CE, IEC 61010-1 |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | P25 / P25T |
| Pricing | Available Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit (Zn at 213.856 nm) | 0.06 ppb |
| Precision (RSD) | ≤0.5% |
| Long-Term Stability (RSD, 4h) | ≤1.5% |
| Wavelength Range | 160–900 nm |
| Optical Resolution | 0.003 nm (at 200 nm) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | PlasmaQuant 9100 |
| Instrument Type | Laboratory ICP-OES |
| Application Scope | Universal |
| Compliance | ASTM D5185, ISO 11885, USP <232>/<233>, EPA Methods 200.7, 200.8, 6010D, 6020B |
| Optical Resolution | ≤2 pm at 200 nm |
| Wavelength Range | 160–900 nm |
| Detector | High-resolution CCD with 43,000 resolvable emission lines |
| RF Generator | Self-oscillating 40 MHz, 700–1700 W |
| Plasma Observation | Enhanced 2+2 dual-view (axial + radial, with signal attenuation and torch tail-flame suppression) |
| Torch Design | V-Shuttle detachable quartz torch with auto-alignment and argon interlock |
| Warm-up Time | <15 min (cold start to quantitative analysis) |
| Software | PQ 9000 Suite with 21 CFR Part 11 compliance mode, audit trail, electronic signatures |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported Instrument |
| Model | PlasmaQuant 9100 |
| Detection Principle | Full-Spectrum Direct-Reading ICP-OES |
| Optical Range | 160–900 nm |
| Optical Resolution | ≤3 pm |
| Wavelength Accuracy | <0.0004 nm |
| Observation Modes | Dual-View (Radial + Axial) with Four Simultaneous Viewing Configurations |
| Plasma System | High-Stability, High-Power RF Generator (27.12 MHz) |
| Detector | Back-Illuminated CCD with Deep-UV Sensitivity |
| Startup Time | <5 minutes |
| Gas Efficiency | Integrated Plasma Gas Recycling for Cooling & Purge Streams |
| Software | Aspect PQ with ABC and CSI Background Correction Algorithms |
| Compliance | Designed for GLP/GMP environments |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported |
| Model | PlasmaQuant 9200 |
| Instrument Category | Full-Spectrum Simultaneous ICP-OES |
| Wavelength Range | 160–900 nm |
| Optical Resolution | 0.002 nm (at 200 nm) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PlasmaQuant MS |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Range (amu) | Not Specified |
| Mass Resolution (Unit Mass Resolution, amu) | Not Specified |
| Detection Limit (ng·L⁻¹) | Not Specified |
| Sensitivity (Mcps/mg·L⁻¹) | Not Specified |
| Short-Term Stability (RSD) | Not Specified |
| Long-Term Stability (RSD) | Not Specified |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | PlasmaQuant MS |
| Instrument Type | Full-Spectrum Direct-Reading ICP-MS |
| Detection Limits | Be ≤ 0.1 ppt, Co ≤ 0.2 ppt, In ≤ 0.05 ppt, Bi ≤ 0.05 ppt, U ≤ 0.01 ppt |
| Precision (RSD) | < 3% |
| Short-Term Stability | < 3%, Long-Term Stability: < 4% |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Instrument Type | Quadrupole ICP-MS |
| Model | PlasmaQuant MS |
| Application Domain | Laboratory-based elemental and isotopic analysis |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Gas Consumption | <9 L/min Ar plasma gas |
| Oxide Rate (CeO⁺/Ce⁺) | ≤1.8% |
| Double-Charge Rate (Ba²⁺/Ba⁺) | ≤2% |
| Detection Limit Performance | 7Li ≥100 Mcps/ppm, 115In ≥500 Mcps/ppm, 238U ≥500 Mcps/ppm |
| Dynamic Range | 0.1–10¹⁰ cps (11-decade linear range in pulse-counting mode) |
| Quadrupole Drive Frequency | 3.0 MHz |
| Mass Scan Speed | 5115 amu/s |
| Minimum Dwell Time | 50 µs |
| iCRC Collision/Reaction Cell | Dual-gas (He/H₂) configurable, with BOOST technology for sensitivity preservation |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PQ LC–PlasmaQuant MS |
| Instrument Type | Triple Quadrupole ICP-MS Coupled with Liquid Chromatography |
| Application Scope | Universal Elemental Speciation |
| Interface Configuration | Integrated LC–ICP-MS Coupling Kit |
| Software Platform | Clarity Chromatography Software (DataApex) + ASpect MS |
| Regulatory Compliance | FDA 21 CFR Part 11–Ready, GLP/GMP-Compatible Data Handling |
| Automation Level | Fully Automated Unattended Operation Support |
| Column Compatibility | Reversed-Phase HPLC, Ion Chromatography (IC), Size-Exclusion Chromatography (SEC) |
| Detection Capability | Sub-ng/kg LODs for As/Cr species |
| Dynamic Range | 11 orders of magnitude (ADD11 digital detector) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported |
| Model | qTOWER 2.2 |
| Price | Upon Request |
| Optical Channels | 6 simultaneous detection channels |
| Excitation Sources | 3 high-intensity LEDs (blue, red, white) |
| Detection Technology | Channel-type photomultiplier tube (CPM) |
| Filter Configurations | 10 interchangeable Ex/Em filter sets |
| Sensitivity | 1 nM FAM in 30 µL reaction volume |
| Sample Capacity | 96-well format |
| Max Ramp Rates | 5.5 °C/s (heating), 4.0 °C/s (cooling) |
| Temperature Uniformity | ±0.2 °C at 95 °C |
| Temperature Accuracy | ±0.1 °C |
| Gradient Range | Up to 40 °C |
| Thermal Lid | 110 °C with SPS (Sample Protection System) and auto-adjusting pressure (up to 10 kg/plate) |
| Software | qPCRsoft v4.x for absolute/relative quantification, ΔΔCt, allelic discrimination, PCR efficiency analysis, and FRET applications |
| Interface | USB 2.0 |
| Dimensions (W×H×D) | 275 × 585 × 275 mm |
| Weight | ~25 kg |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | qTOWER3 G IVD |
| Pricing | Available Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | qTOWER3 G touch |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 96-well format |
| Maximum Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.10 °C |
| Excitation Source | Four solid-state RGBW LEDs (blue, green, red, white) |
| Detection System | 8-channel fiber-optic scanning with channel-type photomultiplier tube (PMT) |
| Detection Channels | Configurable 1–6 channels |
| Thermal Gradient | 12-column linear gradient (spanning up to 40 °C) |
| Sample Block Material | Gold-plated pure silver block |
| Lid System | Motorized, pressure-regulated heated lid with auto-height adjustment |
| Software | qPCRsoft v5.x compliant with MIQE guidelines, supporting absolute quantification, relative quantification (ΔΔCt & dual standard curve), melting curve analysis, SNP/allelic discrimination, endpoint analysis, amplification efficiency calculation, and audit-trail-enabled reporting per FDA 21 CFR Part 11 requirements |