API
Filter
Showing 1–30 of 37 results
| Brand | API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AutoCollimator-Laser |
| Pricing | Upon Request |
| Resolution | 0.1 arcsecond |
| Angular Range | ±400 arcseconds |
| Maximum Measurement Distance | 15 m (49.2 ft) |
| Accuracy | ±1 arcsecond (optional ±0.2 arcsecond) |
| Brand | API |
|---|---|
| Origin | USA |
| Model | Axxis |
| Probe Weight | < 400 g |
| Sampling Rate | Up to 26,000 points/sec |
| Depth of Field | 100–200 mm |
| Measurement Accuracy | ±0.05 mm (2σ) |
| Repeatability | ±0.02 mm (3σ) |
| Operating Temperature | 0–45 °C |
| Relative Humidity | < 70 % RH |
| Compliance | ISO 10360-8 (for articulated arm-based laser scanning systems), ASTM E2924-22 (Standard Guide for 3D Scanning Systems in Industrial Metrology) |
| Brand | API |
|---|---|
| Origin | USA |
| Model | API Axxis |
| Series Options | Series 100 (High-Accuracy), Series 200 (Standard-Accuracy) |
| Measurement Diameter | 2600 mm / 3200 mm / 4200 mm |
| Volumetric Accuracy | 0.060 mm to 0.350 mm (depending on model and configuration) |
| Arm Weight | ~4 kg |
| Degrees of Freedom | 6-axis articulating arm |
| Interface | USB 2.0 (hot-pluggable) |
| Environmental Compensation | Integrated temperature & humidity sensors with real-time thermal drift correction |
| Compatible Probe Types | Renishaw-triggered tactile probes, broadband laser line scanners, dedicated non-contact tube measurement probes |
| Software Compatibility | PowerINSPECT, Mastercam, Rhinoceros, AlphaCAM, Capps-NT |
| Compliance | Designed for ISO 10360-2, ASME B89.4.10, and ASTM E1316-compliant measurement workflows |
| Brand | API |
|---|---|
| Origin | USA |
| Model | Axxis |
| Series Options | Series 100 (High-Accuracy), Series 200 (Standard-Accuracy) |
| Measurement Diameter | 2600 mm / 3200 mm / 4200 mm |
| Volumetric Accuracy | 0.060 mm to 0.350 mm (depending on model and configuration) |
| Arm Weight | ~4 kg |
| Degrees of Freedom | 6-axis articulating arm |
| Interface | USB 2.0 (hot-pluggable) |
| Environmental Compensation | Integrated temperature & humidity sensors with real-time thermal drift correction |
| Compatible Probe Types | Renishaw-triggered tactile probes, broadband laser line scanners, dedicated non-contact tube measurement probes |
| Brand | API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CoreGAGE |
| Configuration | Articulated Arm CMM |
| Operation Mode | Manual |
| Form Factor | Portable |
| Measurement Method | Hybrid Contact & Non-Contact (Tactile Probe + Laser Line Scanner) |
| Measurement Volume Range | 2.0 m to 5.5 m (configurable by arm length) |
| Volumetric Accuracy | ±0.027 mm (ISO 10360-2 compliant) |
| Maximum Data Acquisition Rate | 1,200,000 points/sec |
| Standard Operating Temperature | 5 °C to 45 °C |
| Laser Line Probe (HDSD) | Accuracy ±15 µm (2σ, near-field), ±28 µm (2σ, far-field) |
| Laser Line Probe Baseline Distance | 115 mm |
| Effective Scan Width | 80 mm (near-field) / 150 mm (far-field) |
| Points per Scan Line | Up to 4,000 |
| Laser Class | Class 2 |
| HDSD Probe Weight | 536 g |
| Arm Material | Aerospace-Grade Carbon Fiber |
| Integrated Balancing System | Yes |
| Battery Life | >10 hours (dual high-capacity Li-ion) |
| Wireless Data Transmission | IEEE 802.11ac Wi-Fi |
| Brand | API |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HS-19GDV |
| Instrument Type | Shore Durometer (Type A & D) |
| Hardness Range | 14–115 Shore A / 20–85 Shore D (typical dual-scale calibration per ASTM D2240) |
| Display | LCD digital readout with statistical functions (mean, delete, hold) |
| Data Output | RS-232 interface for optional printer or PC connectivity |
| Hardness Conversion | Built-in algorithms for approximate conversion to Brinell (HB), Rockwell (HRB/HRC), and Vickers (HV) scales per ISO 14676 and ASTM E140 |
| Brand | API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | iLT |
| Quotation | Upon Request |
| Maximum Measurement Range | 160 m |
| Measurement Resolution | 0.08 µm |
| Measurement Accuracy | Contact for certified specifications per ISO 10360-12 and VDI/VDE 2617 Part 19 |
| Horizontal Rotation | ±320° |
| Vertical Pitch | −59° to +79° |
| Tilt Capability | Unlimited (via motorized gimbal stabilization) |
| Integrated Camera | 8 MP iVision Smart Camera |
| ADM Sampling Rate | 1 kHz |
| Weight | 4.9 kg |
| Dimensions | Compact monolithic housing (integrated controller & tracker) |
| Power System | Hot-swappable Li-ion battery (4 h continuous operation) |
| Environmental Compensation | Onboard meteorological station (temperature, pressure, humidity) |
| Data Transmission | IEEE 802.11ac Wi-Fi, no external cabling required |
| GPU Acceleration | Embedded AI-optimized GPU for real-time image processing and target recognition |
| Brand | API |
|---|---|
| Origin | USA |
| Model | iScan Magic |
| Max Measurement Range | 160 m |
| Resolution | 0.010 mm |
| Accuracy | up to 0.020 mm |
| Pan Angle | Unlimited |
| Tilt Angle | Unlimited |
| Pitch Angle | Unlimited |
| Scan Rate | up to 4,150,000 pts/sec |
| Depth of Field | 925 mm |
| Combined 3D Measurement Accuracy | 0.015 mm + 0.012 mm/m |
| Brand | API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LD-8 / LD-15 / LD-25 |
| Measurement Speed | 180°/s |
| Linear Accuracy | 20 μm + 2 μm/m |
| 3D Accuracy | 25 μm + 6 μm/m |
| Spatial Resolution | 0.05 mm to 10 mm (horizontal point spacing) |
| Maximum Measurement Range | 25 m |
| Operating System | Windows 10 |
| Host Weight | 10.4 kg |
| Brand | API |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LJG-B |
| Pricing | Available Upon Request |
| Brand | API |
|---|---|
| Model | N901 |
| Detection Principle | Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Measured Parameters | Total Hydrocarbons (THC), Methane (CH₄), Non-Methane Hydrocarbons (NMHC) |
| NMHC Calculation Method | NMHC = THC − CH₄ |
| Detector Type | Flame Ionization Detector (FID) |
| Sample Inlet Filtration | Stainless Steel Sintered Filter |
| Control & Data Processing | Integrated NumaView™ Software (NVS), Standalone Operation |
| Compliance Context | Designed for EPA Method 25A, ASTM D6348, ISO 8573-5, and EU Directive 2008/50/EC ambient air monitoring requirements |
| Power Consumption | Low-power embedded architecture |
| Design Philosophy | Modular hardware, field-serviceable electronics, maintenance-minimized gas path |
| Brand | API |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Nebula |
| Configuration | Horizontal Arm CMM |
| Operation Mode | Motorized Automatic |
| Application Class | Shop-Floor CMM |
| Measurement Range (X×Y×Z) | 0–10,000 mm |
| Volumetric Accuracy | ±(0.02 + 0.02L) mm, where L is measured length in meters |
| Brand | API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PlusGAGE |
| Configuration | Articulated Arm CMM |
| Operation Mode | Manual |
| Form Factor | Portable |
| Measurement Method | Hybrid Contact & Non-Contact (Laser Line Probe Compatible) |
| Measurement Volume | 2 m to 5.5 m (configurable) |
| Volumetric Accuracy | ±0.009 mm |
| Maximum Data Acquisition Rate | 1,200,000 points/sec |
| Operating Temperature Range | 5 °C to 45 °C |
| Laser Line Probe (HDSD) | Accuracy ±15 µm (2σ), ±28 µm (2σ) |
| Brand | API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ProGAGE |
| Configuration | Articulated Arm CMM |
| Operation Mode | Manual |
| Form Factor | Portable |
| Measurement Method | Hybrid Contact & Non-Contact (Laser Line Probe Compatible) |
| Measurement Volume | 2.0 m to 5.5 m (configurable) |
| Volumetric Accuracy | ±0.007 mm (ISO 10360-2 compliant) |
| Maximum Data Capture Rate | 1,200,000 points/sec |
| Operating Temperature Range | 5 °C to 45 °C |
| Laser Line Probe (HDSD) | Accuracy ±15 µm (2σ, near-field), ±28 µm (2σ, far-field) |
| Laser Line Probe Working Distance | 115 mm (nominal) |
| Laser Line Probe Scan Width | 80 mm (near-field) to 150 mm (far-field) |
| Laser Line Probe Points per Line | Up to 4,000 |
| Laser Class | Class 2 |
| Laser Probe Weight | 536 g |
| Arm Material | Aerospace-Grade Carbon Fiber |
| Wireless Data Transmission | IEEE 802.11ac Wi-Fi |
| Brand | API |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Propeller Pitch Measuring Machine Model A |
| Pricing | Available Upon Request |
| Key | Brand: API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Pricing | Upon Request |
| Resolution | 0.25 µm |
| Accuracy | 0.5 µm |
| Max Measuring Radius | 1500 mm |
| Sensor Type | High-Precision Inductive Transducer |
| Calibration | NIST-Traceable Laser Interferometer Calibration |
| Brand | API |
|---|---|
| Origin | USA |
| Type | Imported Precision Geometric Measurement Instrument |
| Measurement Principle | Capacitive Liquid-Electronic Dual-Axis Inclinometry |
| Range | ±800 arcsec (±5.8 mm/m) |
| Resolution | 0.1 arcsec (0.48 µm/m) |
| Accuracy | ±1.0 arcsec or ±1% of reading (±4.8 µm/m) |
| Axis Configuration | Simultaneous X-Y dual-axis sensing |
| Sensor Technology | Hermetically sealed capacitive electrolytic fluid cell |
| Mechanical Design | Solid-state, no moving parts |
| Compliance | Designed for ISO 10360-2, ASME B89.4.1, and VDI/VDE 2617 Part 6 alignment verification protocols |
| Brand | API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Pricing | Upon Request |
| Measurement Range | 0.1–0.8 mm (0.004–0.032 in) |
| Resolution | 0.1 µm |
| Precision | 0.5 µm |
| Brand | API |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Saturn |
| Operation Mode | Manual |
| Instrument Type | Horizontal Configuration |
| Measurement Range | Custom-Engineered per On-Site Installation Requirements |
| Measurement Accuracy | Available upon Technical Consultation |
| Structural Frame | High-Strength Anodized Aluminum Alloy (Natural & Artificial Aging) |
| X-Axis Guidance | Low-Friction Precision Linear Bearing System with 90° Directional Flexibility |
| Y-Axis Support | Central Steel Reinforcement with Micrometer-Level Fine Adjustment |
| Sensor System | IP65-Rated Absolute Position Encoders Compatible with Magnetic Scale Technology |
| Display | Real-Time XYZ Coordinate Readout (Metric Units) |
| Standard Tooling | Interchangeable Scribing Probe Assembly for Marking and Contact Metrology |
| Brand | API |
|---|---|
| Origin | USA |
| Model | SC100M |
| Measurement Range | ±220° (440° total) |
| Accuracy | ±1 arcsecond |
| Resolution | 0.36 arcsecond |
| Shaft Interface Diameter | 1 in (25.4 mm), optional 25 mm |
| Weight | 4.1 kg |
| Dimensions | 130 × 185 × 220 mm |
| Interface | RS232 |
| Construction | Integrated servo motor, electrolytic tilt sensor (pendulum-type electronic level), and dual high-precision round glass gratings with angular encoders |
| Brand | API |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Pricing | Available Upon Request |
| Measurement Range | Up to 60 m (diameter) |
| Pitch/Yaw/Roll Range | ±35° |
| Probe Stem Lengths | 50 mm, 100 mm, 200 mm (standard) |
| Absolute Accuracy | ±0.05 mm (2σ, ≤10 m with 100 mm stem) |
| Absolute Accuracy | ±0.05 mm + 10 ppm (2σ, >10 m with 100 mm stem) |
| Target Accessibility | Hidden features, deep cavities, reverse-engineering surfaces |
| Brand | API |
|---|---|
| Origin | USA |
| Model | SPN300 |
| Sensor Type | Capacitive/Inductive |
| Resolution | 0.1 µm |
| Dynamic Response | 25 kHz |
| Measurement Range | 0.1–0.8 mm |
| Linearity | < 0.1% FS |
| Thermal Stability | < 0.1% / °C |
| Sensor Dimensions | 30.5 mm (Ø) × 53.3 mm (L) |
| Brand | API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Swivelcheck |
| Price Range | USD 14,000 – 70,000 |
| Brand | API |
|---|---|
| Origin | USA |
| Model | T100 |
| Detection Principle | Ultraviolet Fluorescence |
| Measurement Range | 0–50 ppb or 0–20 ppm (selectable dual range) |
| Zero Noise | 0.2 ppb (RMS) |
| LOD | 0.4 ppb |
| Zero Drift | <0.5 ppb/24 h, <1 ppb/7 d |
| Span Drift | <0.5%/24 h, <1%/7 d |
| Response Time (T95) | <100 s |
| Sample Flow Rate | 700 cm³/min ±10% |
| Linearity | ±1% of full scale |
| Accuracy | ±0.5% of reading |
| Temperature Compensation | Yes |
| Pressure Compensation | Yes |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz, 250 W |
| Dimensions (H×W×D) | 178 × 432 × 597 mm |
| Weight | 16 kg |
| Certifications | U.S. EPA EQPM Designated, Eignungsgeprüft, CE |
| Brand | API |
|---|---|
| Origin | USA |
| Model | T200 |
| Type | Online Gas Analyzer |
| Measurement Principle | Chemiluminescence |
| Detection Targets | NO, NO₂, NOₓ (simultaneously independent) |
| Range Options | 0–50 ppb or 0–20 ppm (dual-range selectable) |
| Zero Noise | 0.2 ppb (RMS) |
| LOD | 0.4 ppb |
| Zero Drift | <0.5 ppb/24 h, <1 ppb/7 d |
| Span Drift | <0.5% of reading/24 h, <1% of reading/7 d |
| Response Time (T95) | <60 s |
| Lag Time | 20 s |
| Sample Flow Rate | 500 cm³/min ±10% |
| Linearity | ±1% of full scale |
| Accuracy | ±0.5% of reading |
| Temperature Range | 5–40 °C |
| Temp. Coefficient | <0.1%/°C |
| Humidity Range | 0–95% RH (non-condensing) |
| Voltage Coefficient | <0.1%/V |
| Dimensions (H×W×D) | 178 mm × 432 mm × 597 mm |
| Weight (Analyzer) | 18 kg |
| External Pump Weight | 7 kg |
| Power | 100–240 VAC, 50/60 Hz, 250 W |
| Output Signals | 10 V, 5 V, 1 V, 100 mV, isolated 4–20 mA, dual bidirectional RS-232 |
| Certifications | U.S. EPA EQPM Designated, CE, Eignungsgeprüft (German PTB Verification) |
| Brand | API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | T3 |
| Pricing | Upon Request |
| Max Tracking Speed | >4.0 m/s |
| Max Acceleration | >2g |
| Tracker Head Weight | 8.5 kg |
| Control Box Weight | 3.2 kg |
| System Total Weight (incl. case & accessories) | 23 kg |
| Effective Measurement Diameter | >120 m |
| Horizontal Field of View | ±320° |
| Vertical Field of View | +80° / −60° |
| Angular Resolution | 0.05 arcsec |
| Length Resolution | 0.1 µm |
| Standard Sampling Rate | 256 pts/sec (optional: 3000 pts/sec) |
| Static 3D Spatial Accuracy | 5 ppm (2σ) |
| Dynamic 3D Spatial Accuracy | 10 ppm (2σ) |
| Repeatability | 2.5 ppm (2σ) |
| Operating Temperature Range | −10 °C to +45 °C |
| ADM Ranging Range | 0–60 m |
| ADM Absolute Distance Accuracy | ±15 µm within 10 m |
| ADM Repeatability | ±2.5 ppm |
| 6DOF Mode | Pitch ±55°, Yaw ±155°, Roll ±30° |
| 6DOF Angular Resolution | 0.001° |
| 6DOF Rotation Speed | >60°/s |
| Brand | API |
|---|---|
| Origin | USA |
| Model | T300 |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Gas Filter Correlation Infrared Absorption (GFC-IR) |
| Measurement Range | 0–1 ppm or 0–1000 ppm (selectable dual range) |
| Repeatability | ±1% of Full Scale (F.S.) |
| Resolution | 0.1 ppm |
| Response Time (T95) | <60 s |
| Zero Drift | <0.1 ppm/24 h, <0.2 ppm/7 days |
| Span Drift | <0.5% of reading/24 h, <1% of reading/7 days |
| Linearity Error | ±1% of full scale |
| Zero Noise (RMS) | <0.02 ppm |
| Span Noise | <0.5% of reading |
| LOD (Limit of Detection) | <0.04 ppm |
| Optical Path Length | 14 m |
| Sample Flow Rate | 800 cm³/min ±10% |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Pressure & Temperature Compensation | Yes |
| Output Signals | 10 V, 5 V, 1 V, 100 mV, 4–20 mA (isolated), dual RS-232 (bidirectional) |
| Power Supply | 100–240 V AC, 50/60 Hz, 250 W |
| Dimensions (H×W×D) | 178 × 432 × 597 mm |
| Weight | 18 kg |
| Certifications | U.S. EPA Designated Method, Eignungsgeprüft (German Performance Verification), CE |
| Brand | API |
|---|---|
| Origin | USA |
| Model | T400 |
| Instrument Type | Fixed-mount |
| Measurement Range | 0–10 ppb (standard), optional dual-range 0–100 ppb / 0–10 ppm |
| LOD | <0.6 ppb |
| Response Time (T95) | <20 s |
| Zero Drift | <1.0 ppb/24 h |
| Span Drift | <1% of reading/7 days |
| Resolution | 0.1 ppb (0–50 ppb range) |
| Sample Flow Rate | 800 cm³/min ±10% |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Power Supply | 100–240 V AC, 50/60 Hz, 250 W |
| Dimensions (H×W×D) | 178 × 432 × 597 mm |
| Weight | 18 kg |
| Output Signals | 0–10 V, 0–5 V, 0–1 V, 0–100 mV, 0–20 mA, or 4–20 mA (isolated) |
| Brand | API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T700 |
| Pricing | Upon Request |
