| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | ASDPure-POU |
| Purification Targets | H₂O, O₂, H₂, CO, CO₂ to < 0.1 ppbv |
| Final Purity Level | < 1 ppb |
| Maximum Flow Rate | < 2000 SLPM |
| Operating Temperature | Ambient |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | ASDPureTM |
| Detection Targets | Trace impurities in helium, hydrogen, nitrogen, carbon dioxide, and other industrial gases |
| Compatible Gases | Ar, He, Ne, Xe, Kr (N₂ purification optional) |
| Impurities Removed | H₂O, O₂, CO, CO₂, H₂, THC, CH₄, N₂ |
| Purification Depth | <1 ppb |
| Flow Rate Options | 300 mL/min, 1 L/min, 5 L/min |
| Operating Temperature | Ambient |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | CGA |
| Price | USD 28,000 (approx.) |
| Linearity Error | <0.1% FS |
| Repeatability | <0.1% FS |
| Span Drift | ≤1% per 30 days |
| Response Time (T90) | 5 seconds |
| Explosion Protection | Not certified (non-hazardous area use only) |
| Sensor Technologies | FID, NDIR, Paramagnetic, Electrochemical (eCell), Alumina-based Hygrometer (Al₂O₃), EPD (Electrostatic Precipitation Detector) |
| Temperature Compensation | Integrated |
| Pressure Compensation | Integrated |
| Calibration Options | Multi-point auto-calibration available per module |
| Module Architecture | Up to 3 internal sensor modules + 1 external Al₂O₃ module |
| Data Logging | Onboard with real-time trend visualization |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FEPID |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Photoionization Detector (PID) |
| Wavelength Range | 100–900 nm |
| Detection Principle | Emission-based Photoionization |
| UV Source | Dielectric Barrier Discharge (DBD) Ultraviolet Lamp |
| Noise Level | <1% RMS |
| Detection Limit | 1 ppb (for benzene-equivalent VOCs) |
| Baseline Drift | <1% over 24 h |
| Signal Channels | 4 independent analog/digital outputs |
| Calibration Accuracy & Repeatability | ±0.1% of full scale |
| Brand | ASD |
|---|---|
| Origin | UK |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Hi-Res NG |
| Spectral Range | 350–2500 nm |
| Detector | InGaAs (SWIR 1 & 2), Si Array (VNIR) |
| Resolution | 3 nm @ 700 nm |
| Sensitivity | 3 nm @ 700 nm |
| SNR | VNIR: 1.0 × 10⁻⁹ W/cm²/nm/sr @ 700 nm |
| SWIR 1 | 8.0 × 10⁻⁹ W/cm²/nm/sr @ 1400 nm |
| SWIR 2 | 8.0 × 10⁻⁹ W/cm²/nm/sr @ 2100 nm |
| Dynamic Range | 16-bit |
| Stray Light | VNIR: 0.02% |
| SWIR 1 & 2 | 0.01% |
| Sampling Interval | 1.4 nm (350–1000 nm) |
| Scan Time | 100 ms |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Accuracy | ±0.5 nm |
| Max Radiance | VNIR: 2× solar |
| SWIR | 10× solar |
| Channels | 2151 |
| FOV | 25° (standard 1.5 m fiber optic cable) |
| Calibration Traceability | NIST-traceable reflectance, radiance, and irradiance (radiometric calibration optional) |
| Weight | 5.44 kg |
| Warranty | 12 months comprehensive coverage including technical support |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | FieldSpec 4 Hi-Res NG |
| Spectral Range | 350–2500 nm |
| Detector Configuration | Si (350–1000 nm), TE-cooled InGaAs (1001–1800 nm), TE-cooled InGaAs (1801–2500 nm) |
| Spectral Resolution | 3 nm @ 700 nm, 6 nm @ 1400 nm & 2100 nm |
| Sampling Interval | 1.4 nm (350–1000 nm), 1.1 nm (1001–2500 nm) |
| Stray Light | <0.02% (VNIR), <0.01% (SWIR 1 & 2) |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.1 nm |
| Integration Time | 100 ms typical |
| NEΔL (VNIR) | 1.0 × 10⁻⁹ W/cm²/nm/sr @ 700 nm |
| NEΔL (SWIR 1) | 8.0 × 10⁻⁹ W/cm²/nm/sr @ 1400 nm |
| NEΔL (SWIR 2) | 8.0 × 10⁻⁹ W/cm²/nm/sr @ 2100 nm |
| Radiance Dynamic Range | Up to 2× solar (VNIR), 10× solar (SWIR) |
| Calibration Traceability | NIST-traceable radiometric, reflectance, irradiance, and colorimetric calibrations available |
| Fiber Input | 1.5 m, 25° FOV (lens options available) |
| Channels | 2151 spectral bands |
| Weight | 5.44 kg |
| Warranty | 12 months comprehensive coverage with technical support |
| Brand | ASD |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FieldSpec HandHeld 2 |
| Instrument Type | Portable |
| Application Domain | Academic & Research (Universities, Earth Observation Labs, Environmental Monitoring) |
| Operating Principle | Fixed Grating with Linear CCD Array Detector (Non-scanning) |
| Wavelength Range | 325–1075 nm |
| Spectral Sampling Interval | 1.5 nm |
| Scan Speed | 10 spectra/sec |
| Measurement Mode | Reflectance (with optional irradiance calibration) |
| Calibration Software | RS3™ |
| Drift Compensation | DriftLock™ Baseline Stabilization Technology |
| Detector Type | Back-thinned Si CCD |
| FOV | 25° (Full Angle) |
| NEdL | 5×10⁻⁹ W/cm²/nm/sr @ 700 nm |
| Spectral Resolution | <3.0 nm FWHM @ 700 nm |
| Wavelength Accuracy | ±1 nm |
| Integration Time Range | 8.5 ms to 10 s (programmable) |
| Onboard Storage | Up to 2000 spectra |
| Display | 2.7-inch tilt-adjustable color LCD (6.8 cm diagonal) |
| Power Supply | 4× AA batteries (rechargeable NiMH or alkaline) or 5 V / 1.5 A AC/DC adapter |
| Battery Life | Up to 5 h (Li-ion), 2.5 h (NiMH), ~1.5 h (alkaline) |
| Dimensions (H×W×D) | 90 × 140 × 215 mm |
| Weight | 1.2 kg (incl. batteries) |
| Operating Temperature | 0–40 °C |
| Targeting Aid | Integrated Class 2 IR laser pointer (650 nm, visible alignment optional) |
| Connectivity | Mini-B USB, mini-TRS remote trigger port, dual Type-A USB expansion ports |
| Software Suite | RS3™ real-time acquisition & configuration, ViewSpecPro™ spectral analysis & chemometric modeling, HH2 Sync Interface for external GNSS/IMU synchronization |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | FieldSpec® 4 HI-RES |
| Detector Type | PDA |
| Wavelength Range | 300–2500 nm |
| Spectral Resolution | 3 nm @ 700 nm, 8 nm @ 1400/2100 nm |
| Scan Time | 100 ms |
| SNR | VNIR: 1.0 × 10⁻⁹ W/cm²/nm/sr @ 700 nm, SWIR1: 1.4 × 10⁻⁹ W/cm²/nm/sr @ 1400 nm, SWIR2: 2.2 × 10⁻⁹ W/cm²/nm/sr @ 2100 nm |
| Stray Light | VNIR: 0.02%, SWIR1/2: 0.01% |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.1 nm |
| Number of Channels | 2151 |
| Communication | 10/100 Base-T Ethernet, IEEE 802.11g Wi-Fi |
| Dimensions (H×W×D) | 12.7 × 36.8 × 29.2 cm |
| Weight | 5.44 kg (battery included: +1.2 kg) |
| Battery Life | 6 h (NiMH, 12 V, 9 Ah) |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −15–45 °C |
| Power Input | 90–240 VAC, 50/60 Hz or 12 VDC, 5 A |
| Certifications | CE (EN61010-1:2001), EU Directives 2006/95/EC & 2004/108/EC, NIST-traceable calibration, WEEE compliant |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | FieldSpec® HandHeld 2™ |
| Detector Type | PDA |
| Wavelength Range | 325–1075 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Resolution | <3.0 nm @ 700 nm |
| NEdL | 5×10⁻⁹ W/cm²/nm/sr @ 700 nm |
| FOV | 25° |
| Integration Time | 8.5 ms (min, adjustable) |
| Memory Capacity | Up to 2000 spectra |
| Display | 2.7″ tilting color LCD |
| Power | 4×AA batteries (rechargeable or alkaline) or 5 V / 1.5 A AC/DC adapter |
| Battery Life | up to 5 h (Li-ion), 2.5 h (NiMH), ~1.5 h (alkaline) |
| Dimensions (H×W×D) | 90 × 140 × 215 mm |
| Weight | 1.2 kg (incl. batteries) |
| Operating Temperature | 0–40 °C |
| Mounting | 1/4″-20 tripod thread |
| Software | RS3™, ViewSpecPro™, HH2 Sync Interface |
| Brand | ASD |
|---|---|
| Origin | United Kingdom |
| Distributor Type | Authorized General Distributor |
| Import Status | Imported |
| Model | FSA (FieldSpec Assistant) Smart Handle |
| Pricing | Available Upon Request |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | iGCS |
| Dilution Ratio Range | 1:2 to 1:3500 (customizable up to 1:10,000) |
| Accuracy | < 0.5% rel. |
| Pressure Control | High-precision electronic pressure controllers (EPC) with temperature compensation |
| Flow Path Material | Fully welded stainless steel |
| Operating Temperature | Up to 200 °C (heated path option) |
| Configurability | User-selectable sonic nozzles and diluent gases |
| Flow Path Options | Dual direct-coupled EPC configuration or high-integrity bypass EPC version |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | iSCS |
| Configuration | Rack-mountable (19″) or Benchtop Standalone |
| Cooling Trap Temperature | –30 °C |
| Thermal Desorption Range | Up to 300 °C |
| Valve Technology | PLSV (Precision Low-Dead-Volume Sampling Valve) |
| Operation Modes | Programmable Stepwise Release or Flash Desorption |
| Diagnostic Capability | Integrated Self-Diagnostic System |
| Connectivity | IoT-enabled for ASDevices Ecosystem |
| Sample Introduction | Front-accessible Cold Trap and Valve Assembly |
| Compliance | Designed for GLP/GMP-aligned laboratory workflows |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA0211 |
| Repeatability | ±1% FS |
| Detection Limit | 0.03 ppm |
| Detector Type | TCD (Thermal Conductivity Detector) |
| Column Oven Temperature Range | 5 °C to 45 °C |
| Carrier Gas Purity Requirement | 5N (99.999%) |
| Compliance | Designed for continuous online operation in industrial process environments |
| Configuration | Modular sensor architecture with field-replaceable sensing modules |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA0221 |
| Repeatability | < ±0.1% O₂ |
| Detection Limit | < ±0.1% O₂ |
| Detector Type | Paramagnetic |
| Column Temperature Control Range | 5 °C to 45 °C |
| Gas Supply Purity | 5N (99.999%) |
| Output | 4–20 mA |
| Communication | RS-485, Ethernet, Modbus (optional) |
| Relay Outputs | 3 × user-configurable dry-contact relays |
| Data Export | CSV format |
| Calibration | Auto/manual zero/span, multi-point, calendar-based scheduling, programmable purge time, intelligent stability detection |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA5800 |
| Instrument Type | Online Analyzer |
| Application Scope | General-Purpose |
| Operating System | Embedded Linux with Touchscreen Interface |
| Detection Principle | Dual-Polarity Pulsed Electrochemical Conductivity Detection |
| Data Acquisition | Real-Time Asynchronous Parallel Chromatography |
| Sample Introduction | Automated Multi-Channel Switching with Integrated Pre-Treatment Module |
| Calibration Method | Single-Point Standard-Based Auto-Calibration |
| Detection Enhancement | eLOD Noise-Filtering Algorithm (3–5× Sensitivity Gain) |
| Gas Capture Technology | Multi-Threaded Aeration Trapping (KA5800-EIC Variant, Patent Pending) |
| Analysis Cycle | <30 min per Full Sequence |
| Sample Volume Requirement | ≤1.5 L for ppb-Level Analysis |
| Compliance Framework | Designed for GLP/GMP Environments |
| Temperature Control | Digital Precision Dual-Zone Column & Detector Thermostat |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | Ka6000 Plus |
| Instrument Type | Online Gas Chromatograph |
| Temperature Control Range | Ambient +4 °C to 450 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Rate | ~6 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Range | 30–100 mL/min |
| Carrier Gas Pressure Range | 90–100 psig |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 3–25 psig |
| Injector Total Flow Setting Range | 5–200 mL/min |
| Column Oven Zones | Up to 4 independently controlled zones |
| Valves | Up to 5 programmable PLSV valves |
| Detectors | Up to 2 gas-phase detectors (e.g., EPD) |
| Detection Limit (LOD) | <1 ppb (stable, compound-dependent) |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA8000 |
| Instrument Type | Online Gas Chromatograph |
| Temperature Control Range | Ambient + 4 °C to 450 °C |
| Ramp Rate | 30–60 °C/min |
| Cool-down Rate | 30–60 °C/min |
| Carrier Gas Flow Range & Control | 20–50 mL/min |
| Carrier Gas Pressure Range & Control | 90–100 psig |
| Injector Maximum Operating Temperature | 200 °C |
| Injector Pressure Setting Range | 5–15 psig |
| Injector Total Flow Setting Range | 20–30 mL/min |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA8000plus-S |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Hydrogen Fuel Purity Analysis |
| Temperature Control Range | Ambient +4 °C to 450 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Rate | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 30–100 mL/min |
| Carrier Gas Pressure Range & Control | 90–100 psig |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 3–25 psig |
| Injector Total Flow Setting Range | 5–200 mL/min |
| Detector | SePDD (Sulfur-Enhanced Plasma Discharge Detector) |
| Valve Configuration | PLSV Inert 6-Port Valve with 2 mL Inert Quantitative Loop |
| Carrier Gas Requirement | Ultra-High-Purity Helium (≥5.0, purified to <1 ppb total impurities via ASDPure gas purifier) |
| Detection Limit | <0.5 ppb (as H₂S equivalent, direct injection) |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | LabSpec 4 Hi-Res |
| Wavelength Range | 350–2500 nm |
| Spectral Resolution | 6 nm @ 1400/2100 nm (Hi-Res) / 10 nm @ 1400/2100 nm (Standard) |
| Scan Time | 100 ms |
| SNR | VNIR 9000:1 @ 700 nm, SWIR1 9000:1 @ 1400 nm, SWIR2 4000:1 @ 2100 nm |
| Detector Configuration | 512-pixel Si array (350–1000 nm) + dual TE-cooled InGaAs arrays (1000–1800 nm & 1800–2500 nm) |
| Certifications | CE (EN 61010-1:2001), EU Directive 2006/95/EC & 2004/108/EC, NIST-traceable calibration |
| Software Compatibility | Indico® Pro, GRAMS (Thermo Scientific), The Unscrambler® (Camo) |
| Connectivity | 10/100Base-T Ethernet, IEEE 802.11g Wi-Fi (up to 300 m line-of-sight) |
| Power | 12 VDC NiMH battery (6 h typical operation), AC/DC adapter (90–240 VAC, 50/60 Hz) |
| Dimensions | 12.7 × 35.6 × 29.2 cm |
| Weight | 5.2 kg (with battery) |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | N2 Sense |
| Detection Limit | 0.5 ppb |
| Repeatability | <1% |
| Detector Type | Enhanced Plasma Discharge (EPD) |
| Column Temperature Range | Ambient +4 °C to 450 °C |
| Carrier Gas Requirement | High-Purity Gas |
| Output | 4–20 mA, Ethernet, RS-232, MQTT |
| Data Storage | 12-month onboard logging |
| Dimensions | 133 × 202 × 330 mm (19″ rack-mountable) |
| Power | 24 VDC, 40 W |
| Operating Temperature | 5–40 °C |
| Sample Flow Rate | 5–200 mL/min |
| Inlet Pressure | 3–25 PSIG |
| Response Time | <10 s (90% step change at 75 mL/min) |
| Drift | <0.5% FS |
| Measurement Ranges | 0–1 ppm, 0–10 ppm, 0–100 ppm, up to 1% N₂ in Ar/He |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | PAD |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Coal Industry-Specific |
| Temperature Control Range | −4 °C to 450 °C |
| Oven Ramp Rate | 30–60 °C/min |
| Oven Cool-Down Rate | 30–60 °C/min |
| Carrier Gas Flow Range & Control | 20–50 mL/min |
| Carrier Gas Pressure Range & Control | 90–100 psig |
| Injector Maximum Operating Temperature | 200 °C |
| Injector Pressure Setting Range | 5–15 psig |
| Injector Total Flow Setting Range | 20–30 mL/min |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | QualitySpec 7000 |
| Wavelength Range | 350–2500 nm |
| Wavelength Accuracy | ±1 nm |
| Spot Size | 76–100 mm |
| Output Interface | Fast Ethernet (100BASE-T or 100BASE-FX) |
| OPC Server Integration | Yes |
| Max. Components Quantified | 20 per measurement |
| Light Source | 100 W Quartz Halogen |
| Optical Head to Conveyor Distance | 74 cm |
| Power Consumption | 230 W (±10%, 12 A, 50/60 Hz) |
| Operating Temperature | −20 to +50 °C |
| Relative Humidity | 5–95% non-condensing |
| Certifications | CE |
| Brand | ASD |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QualitySpec Trek |
| Price | Upon Request |
| Wavelength Range | 350–2500 nm |
| Spectral Resolution | 3 nm @ 700 nm, 9.8 nm @ 1400 nm, 8.1 nm @ 2100 nm |
| Dimensions (L×W×H) | 775 mm × 250 mm × 750 mm |
| Weight with Battery | 2.5 kg (5.5 lbs) |
| Weight without Battery | 2.0 kg (4.3 lbs) |
| Operating Languages | English, Spanish, Chinese |
| Integrated GPS | Yes |
| Voice Memo Function | Yes |
| Display | Integrated LCD |
| Connectivity | Wireless (Wi-Fi/Bluetooth) |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Manufacturer Type | General Distributor |
| Origin Category | Imported |
| Model | SePdd |
| Quotation | Upon Request |
| Compatible Instrument | Gas Chromatograph |
| Instrument Type | Specialized Chromatographic Detector |
| Wavelength Range | 100 nm – 900 nm |
| Detection Mode | Emission |
| Light Source | Plasma Discharge |
| Noise | <1% |
| Detection Limit | 1 ppb |
| Baseline Drift | <1% |
| Signal Channels | 4 |
| Adjustment Accuracy / Repeatability | ±1% |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | TerraSpec 4 Hi-Res |
| Wavelength Range | 350–2500 nm |
| Spectral Resolution | 3 nm @ 700 nm, 6 nm @ 1400/2100 nm |
| Scan Speed | 100 ms |
| SNR | VNIR 9000:1 @ 700 nm, SWIR1 9000:1 @ 1400 nm, SWIR2 4000:1 @ 2100 nm |
| Stray Light | VNIR 5000:1 (0.02%), NIR 10000:1 (0.01%) |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Accuracy | ±0.5 nm |
| Detector | 512-pixel Si array (350–1000 nm), TE-cooled InGaAs gradient-index arrays (1001–1800 nm & 1801–2500 nm) |
| Interface | 10/100 Base-T Ethernet, 802.11g Wi-Fi |
| Dimensions (H×W×D) | 12.7 × 36.8 × 29.2 cm |
| Weight | 5.44 kg (instrument), +1.2 kg (battery) |
| Battery Life | ~6 h (standalone) |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −15–45 °C |
| Power Input | 90–240 VAC / 50–60 Hz or 12 VDC / 60 W |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | TerraSpec 4 Hi-Res |
| Spectral Range | 350–2500 nm |
| Detector | InGaAs |
| Resolution | 3 nm @ 700 nm |
| Sensitivity | 75 photons/count |
| SNR | VNIR 9000:1 @ 700 nm |
| SWIR1 9000 | 1 @ 1400 nm |
| SWIR2 4000 | 1 @ 2100 nm |
| Dynamic Range | 7.5×10⁹ |
| Stray Light | VNIR 5000:1 (0.02%) |
| NIR 10000 | 1 (0.01%) |
| Brand | ASD |
|---|---|
| Origin | UK |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | TerraSpec Halo |
| Pricing | Upon Request |
| Brand | ASD |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Halo |
| Instrument Type | Portable |
| Application Field | General (Universities, Research Institutes) |
| Operating Principle | Grating-Based Array Detector (Non-Scanning) |
| Wavelength Range | 350–2500 nm |
| Scan Speed | 10 spectra/sec |
| Spectral Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | ASD Halo Manager |
| Spectral Resolution | 3 nm @ 700 nm, 9.8 nm @ 1400 nm, 8.1 nm @ 2100 nm |
| Dimensions (L×W×H) | 775 × 250 × 750 mm |
| Weight (with battery) | 2.5 kg (5.5 lbs) |
| Weight (without battery) | 2.0 kg (4.3 lbs) |
| Supported Languages | English, Spanish, Chinese |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | IC-KA5800 |
| Instrument Type | Online Analyzer |
| Application Scope | Universal Gas Impurity Analysis |
| Compliance Framework | ASTM D7622, ISO 14687-2, GB/T 37244–2018, USP <645> (for total ionizable impurities) |