Online Gas Chromatograph
Filter
Showing 1–30 of 44 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PGC2000 Series |
| Pricing | Upon Request |
| Brand | ABB |
|---|---|
| Origin | USA |
| Model | PGC5000 |
| Detection Principles | Gas Chromatography with Thermal Conductivity (TCD), Flame Ionization (FID), and Flame Photometric (FPD) Detection |
| Column Oven Configurations | Dual Intelligent Isothermal Zones (PGC5000B & PGC5000C) |
| Interface | 10.4″ SVGA Touchscreen HMI, Redundant Ethernet, USB, MODBUS RTU/TCP, Analog/Digital I/O |
| Compliance | Designed for SIL2-capable system integration per IEC 61511, compatible with FDA 21 CFR Part 11 audit trail requirements via optional software configuration |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC23 THC Analyzer |
| Detection Principle | Catalytic Combustion + Methane Conversion + Flame Ionization Detection (FID) |
| Display | 5.7″ QVGA Touchscreen |
| Calibration | Automated Zero/Range Calibration via Internal Solenoid Valves |
| Flow Control | Digital Electronic Mass Flow Controllers (MFCs) |
| Sample Flow Monitoring | Real-time Digital Flow Visualization & Alarm |
| Output Signals | 2 × Isolated, Passive 4–20 mA Outputs |
| Communication | RS-232 Serial Interface |
| Range Selection | 3 Auto-ranging Full-Scale Ranges |
| Compliance Support | Designed for ISO 8573-5, ASTM D6245, EPA Method 25A, and EN 15409-compliant installations |
| Safety Certification | ATEX / IECEx Zone 2 (optional), CE Marked |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaPRO9000 |
| Repeatability | ±0.1% |
| Detection Limit | 1 ppb |
| Detector Type | Helium Discharge Ionization Detector (DID) |
| Column Oven Temperature Range | Ambient to 450 °C with Independent Per-Column Thermal Control |
| Carrier Gas Requirement | Ultra-High-Purity Helium (99.999%) |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC STREAM 6000 |
| Detection Principle | High-Frequency Argon Discharge Detector (HFADD) |
| Measurement Range | 0–1 ppm / 0–10 ppm / 0–100 ppm |
| LOD | 10 ppb |
| Accuracy | ±1% of full scale |
| Zero Drift | <1% FS / Span Drift: <1% FS |
| Response Time (t₉₀) | 5 s |
| Display | 6.5" industrial-grade touchscreen |
| Signal Outputs | 2 × 4–20 mA, 1 × mV, VGA, USB |
| Communication Options | RS-232 / RS-485 / Ethernet (optional) |
| Alarm Outputs | 7 dry-contact relays (including sample flow monitor) |
| Calibration | Auto-calibration with audit-trail logging |
| Data Storage | Internal non-volatile memory (24-month trend retention) |
| Sample Flow Rate | 5–200 mL/min |
| Inlet Pressure | 10–50 kPa |
| Power | 100–120 VAC / 220–240 VAC, 50/60 Hz |
| Dimensions | 482 mm (W) × 511 mm (D) × 177 mm (H), 4U 19″ rack-mountable |
| Weight | 9 kg |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA0211 |
| Repeatability | ±1% FS |
| Detection Limit | 0.03 ppm |
| Detector Type | TCD (Thermal Conductivity Detector) |
| Column Oven Temperature Range | 5 °C to 45 °C |
| Carrier Gas Purity Requirement | 5N (99.999%) |
| Compliance | Designed for continuous online operation in industrial process environments |
| Configuration | Modular sensor architecture with field-replaceable sensing modules |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA0221 |
| Repeatability | < ±0.1% O₂ |
| Detection Limit | < ±0.1% O₂ |
| Detector Type | Paramagnetic |
| Column Temperature Control Range | 5 °C to 45 °C |
| Gas Supply Purity | 5N (99.999%) |
| Output | 4–20 mA |
| Communication | RS-485, Ethernet, Modbus (optional) |
| Relay Outputs | 3 × user-configurable dry-contact relays |
| Data Export | CSV format |
| Calibration | Auto/manual zero/span, multi-point, calendar-based scheduling, programmable purge time, intelligent stability detection |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | N2 Sense |
| Detection Limit | 0.5 ppb |
| Repeatability | <1% |
| Detector Type | Enhanced Plasma Discharge (EPD) |
| Column Temperature Range | Ambient +4 °C to 450 °C |
| Carrier Gas Requirement | High-Purity Gas |
| Output | 4–20 mA, Ethernet, RS-232, MQTT |
| Data Storage | 12-month onboard logging |
| Dimensions | 133 × 202 × 330 mm (19″ rack-mountable) |
| Power | 24 VDC, 40 W |
| Operating Temperature | 5–40 °C |
| Sample Flow Rate | 5–200 mL/min |
| Inlet Pressure | 3–25 PSIG |
| Response Time | <10 s (90% step change at 75 mL/min) |
| Drift | <0.5% FS |
| Measurement Ranges | 0–1 ppm, 0–10 ppm, 0–100 ppm, up to 1% N₂ in Ar/He |
| Brand | ASDevices |
|---|---|
| Origin | Canada |
| Model | KA8000Ex |
| Repeatability | ±2% |
| Detection Limit (MDL) | 0.5 ppb H₂S |
| Detector Type | EPD (Enhanced Plasma Discharge Detector) |
| Column Oven Temperature Range | −4 °C to 200 °C |
| Carrier Gas Requirement | 5N-grade He, Ar, or N₂ |
| Brand | Asicotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Industrial Instrument |
| Model | P5100 |
| Price Range | USD 70,000 – 140,000 |
| Brand | Asicotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PGC-3000 |
| Price Range | USD 70,000 – 140,000 |
| Brand | Chrom |
|---|---|
| Model | GC-80PDD on-line |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDHID) |
| Column Temperature Range | Up to 420°C |
| Pressure Control | Up to 100 psi |
| Split Ratio | Up to 999.9:1 |
| Baseline Noise | ≤0.02 mV |
| Baseline Drift | ≤0.5 mV/30 min |
| Repeatability (CH₄) | RSD ≤3.0% |
| Detection Limit (CH₄) | ≤3.5×10⁻¹³ g/mL |
| Power Consumption | <2.0 kW |
| Temperature Control Accuracy | ±0.1°C |
| Output Interfaces | 4–20 mA (up to 8 channels), RS232/RS485, Ethernet |
| Enclosure | 19″ rack-mount, 6U standard chassis |
| Carrier Gas | Ultra-high-purity helium |
| Compliance | Designed for continuous industrial process monitoring per ISO/IEC 17025-aligned operation and compatible with DCS integration under IEC 61511 functional safety context |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GC-2000 |
| Pricing | Upon Request |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | FOV 3000 |
| Pricing | Upon Request |
| Explosion-Proof Enclosure | FL3000 EX (316 Stainless Steel Powder-Coated) |
| Dimensions (W×D×H) | 800 × 800 × 1800 mm |
| Compressed Air Requirement | ≥0.1 MPa, 0.5 m³/h |
| Power Supply | 220 VAC, 5 kW |
| Operating Temperature Range | −10 to +45 °C |
| Explosion Protection Rating | Ex db mb px b IIC T6 Gb |
| Detectors Supported | FID, TCD, ECD, FPD, NPD, PDHID |
| Column Oven | Five-Zone Independent Temperature Control with Back-Door Rapid Cooling & Programmable Ramp |
| Carrier Gas Control | Third-Generation Fulit EPC (Electronic Pressure Control) |
| Communication Interfaces | Ethernet, 4G, Wi-Fi, RS232/RS485/RS422, 4–20 mA Analog Output |
| Software Platform | LoongOS-5.0 (Linux-based, proprietary real-time OS) |
| Data Storage | Embedded MariaDB — ≥1 year of quantitative results |
| Compliance Standards | HJ 38–2017, HJ 604–2017, HJ 1013–2018, HJ 212, FL97, Modbus/TCP, Modbus-RTU |
| Brand | GAOMAI |
|---|---|
| Origin | Beijing, China |
| Model | GM-816 |
| Detection Limit | <5 ppb (CH₄, with DID detector) |
| Linear Dynamic Range | >10⁶ |
| Maximum Detector Capacity | 3 simultaneous detectors (e.g., DID-V, TCD, FPD, FID) |
| Column/Valve Configuration | Up to 10 columns and 5 multi-dimensional switching valves |
| Flow Control | Electronic Pressure Control (EPC) |
| Power Supply | 220 V ±10%, 2250 W |
| Connection Standard | VCR fittings for low-dead-volume gas pathways |
| Valve Oven Protection | Integrated valve box with thermal stabilization and contamination isolation |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GC-4085 |
| Pricing | Upon Request |
| Brand | GAOMAI |
|---|---|
| Origin | Beijing, China |
| Model | GM 1900 Explosion-Proof Series |
| Explosion Protection Mark | Ex de ib mb px IIC T4 Gb |
| IP Rating | ≥IP65 |
| Positive Pressure Range | 0–2069 Pa |
| Purge Time | 0–999 min (adjustable) |
| Alarm & Cut-off Pressure | 0–2069 Pa (adjustable) |
| Cabinet Dimensions | 90 cm × 75 cm × 50 cm |
| Gas Piping | EP-grade stainless steel tubing with orbital welding or VCR fittings |
| Pre-shipment Tests | Pressure hold, leak detection, moisture analysis, oxygen analysis, particle count |
| Compliance | Certified by National Supervisory Inspection Center for Explosion-Protected Instrumentation (Cert. No.: GYB21.3140X) |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | 1400 |
| Measurement Range | 0–2 ppm / 0–20 ppm / 0–200 ppm H₂O in Ar |
| Accuracy | ±0.02 ppm (0–2 ppm), ±0.25 ppm (0–20 ppm), ±2.50 ppm (0–200 ppm) |
| Response Time (t₉₀) | ≤10 s |
| Sample Flow Rate | 2 scfh (0.88 slpm) |
| Inlet/Outlet Fittings | 1/4" VCR inlet, 1/4" Swagelok outlet |
| Operating Temperature | 16–35 °C |
| Max Inlet Pressure | 10 psig |
| Detector Type | Microwave-Induced Plasma Emission Spectroscopy (MIP-ES) |
| Sensitivity | ±0.01 ppm (Model 1400-A/1402-A), ±0.10 ppm (Model 1400-B/1402-B) |
| Output | 4–20 mA analog + dry contact alarms |
| Power | 100 W, 115/230 VAC, 50/60 Hz |
| Dimensions | 13.34 × 42.23 × 37.15 cm |
| Weight | 11.3 kg |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GOW-MAC 200DID |
| Detector Type | Helium Discharge Ionization Detector (DID) |
| Detection Limit | <5 ppb |
| Linear Dynamic Range | >10⁶ |
| Column Oven Temperature Range | +10 °C to 150 °C |
| Column Format | Micro-packed and 1/8″ packed columns |
| Flow Control | Precision Mass Flow Controllers |
| Sample Introduction | Pneumatically Actuated Gas Sampling Valve |
| Valve Configurations | Backflush, Column Selection, Heart-Cut, Series/Bypass |
| Construction Materials | Electropolished Stainless Steel with VCR Fittings |
| Operating Modes | Manual (for method development) and Fully Automated (for continuous process analysis) |
| Compliance | Designed for GLP/GMP environments |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GOW-MAC 210 AHC |
| Detection Limit | <30 ppb |
| Carrier Gas Flow Rate | ≈30 cc/min |
| Carrier Gas Pressure | 60 psig |
| Sample Inlet Pressure | 5 psig (max 20 psig) |
| Calibration Gas Pressure | 5 psig (max 20 psig) |
| Operating Temperature | 5–40 °C |
| Power Requirement | 400 W |
| Dimensions (W×H×D) | 42.9×31.1×58.4 cm |
| Net Weight | 23 kg |
| Mounting | 19″ EIA rack (7U) or benchtop |
| Gas Fitting | 1/8″ Swagelok |
| Analog Outputs | six 4–20 mA channels |
| Input Trigger | TTL or dry contact |
| Display | 16×2 character LED-backlit LCD (99.0×24.0 mm active area) |
| User Interface | membrane keypad (non-contact digital input) |
| Linear Range | 5–120 ppb (1×10³ dynamic range) |
| Sample Introduction | dual-solenoid automated valve system with fixed-volume sampling loop |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GOW-MAC 210 BTEX |
| Detection Limit | <5 ppb |
| Linear Range | 5 ppb to 5 ppm |
| Carrier Gas Flow Rate | ≈7 cc/min |
| Carrier Gas Pressure | 5–10 psig |
| Sample/Calibration Gas Pressure | 5 psig (max 20 psig) |
| Operating Temperature | 5–40 °C |
| Power Requirement | 400 W |
| Dimensions (W×H×D) | 42.9 × 31.1 × 58.4 cm |
| Weight | 23 kg (net), 28 kg (shipping) |
| Gas Fitting | 1/8" Swagelok |
| Mounting | EIA 19" rack (7U) or benchtop |
| Analog Outputs | six 4–20 mA channels |
| Input Trigger | TTL or dry contact |
| Display | 16×2 character LED backlight |
| User Interface | membrane keypad (non-contact, numeric) |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GOW-MAC 2400 |
| Detector | Flame Ionization Detector (FID) |
| Detection Limit | 0.05 ppm (as CH₄) |
| Operating Temperature | 15–35 °C |
| Response Time | <5 s (to 90% of full response) |
| Drift | <1% FS/24 h |
| Repeatability | ±1% |
| Flow Control | Electronic Pressure Control (EPC) for fuel, air, and sample |
| Zero Interval | User-programmable auto-zero |
| Range Selection | 4 fixed ranges (0–10, 0–100, 0–1000, 0–10,000 ppm) or auto-ranging |
| Analog Output | 4–20 mA / 0–5 VDC (standard) |
| Digital Interface | USB + RS-232 |
| Relay Outputs | 2 programmable (high/low alarm) |
| Sample Inlet | 1/8" tubing, min. pressure 2 psig, flow 5–70 cc/min |
| Fuel Gas | H₂, min. 2 psig |
| Combustion Air | Zero-air (<1 ppm THC), min. 25 psig, flow 10–350 cc/min |
| Enclosure | 3U rack-mount (19″) or benchtop |
| Dimensions | 48.3 × 13.3 × 52.1 cm |
| Weight | 15.9 kg |
| Power | 100 W, 115 V 60 Hz (2400-CM) or 230 V 50 Hz (2402-CM) |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GOW-MAC 402 |
| Price Range | USD 1,500 – 7,500 |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GOW-MAC 5900 DID |
| Detector Type | Discharge Ionization Detector (DID) |
| Detection Range | 1 ppb to <0.5% (v/v) |
| Carrier Gas | Helium |
| Construction | Stainless Steel or Corrosion-Resistant System |
| Compliance | Designed for Industrial Process Monitoring and Trace Impurity Analysis |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | 592 |
| Detector Type | Discharge Ionization Detector (DID) |
| Detection Range | 1 ppb to <0.5% (v/v) |
| Carrier Gas | Ultra-High-Purity Helium |
| Installation Options | Benchtop or 19″ Rack-Mounted |
| Construction Options | Stainless Steel or Corrosion-Resistant Wet-Coated Surfaces |
| Compliance | Designed for ASTM D7613, ISO 8573-5, and semiconductor-grade gas purity monitoring |
| Brand | GOW-MAC |
|---|---|
| Model | GM 1900 |
| Origin | Beijing, China |
| Detector Options | DID-V, TCD, FID |
| Detection Limit (CH₄) | <10 ppb |
| Operating Mode | Continuous 24/7 online analysis |
| Temperature Control | Microprocessor-regulated inlet, column oven, and detector zones |
| User Interface | High-resolution resistive touch LCD panel |
| Corrosion Protection | Wet-coated wetted surfaces |
| Compliance Features | Built-in self-diagnostic, purge gas safeguard, auto-reboot on power recovery, alarm logging |
| Brand | JKRD |
|---|---|
| Model | BGC5000 |
| Origin | Beijing, China |
| Detector Types | PDHID, TCD, FID, FPD |
| Reproducibility | ±1% FS (major components), ±2% FS (trace components) |
| Max. Stream Count | 24 |
| Analog Outputs | 4–36 channels (4–20 mA, isolated) |
| Display | 10.4" color touchscreen |
| Oven Temp. Range | 45–125°C (±0.1°C stability) |
| Carrier Gas | He, H₂, N₂, or Ar (30–300 mL/min, ≥99.99% purity) |
| Explosion Protection | Ex d px II C T1–T4 Gb (pressurized enclosure) |
| Weight | 120 kg |
| Brand | KA |
|---|---|
| Origin | Canada |
| Model | KA 8000Plus |
| Repeatability | <1% RSD |
| Detection Limit | 0.5 ppb |
| Detector Type | Enhanced Plasma Discharge Detector (EPD) |
| Column Oven Temperature Range | –4 °C to 450 °C |
| Carrier Gas Requirement | Ultra-High-Purity Gases |
| Regulatory Status | Import-Class Industrial Instrument |
| Brand | KA |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KA8000Ex |
| Price Range | USD 68,000–136,000 (FOB) |
| Repeatability | <1% RSD |
| Detection Limit | <1 ppb (H₂S, COS, SO₂, CH₃SH) |
| Detector Type | Enhanced Plasma Detector (EPD) |
| Column Oven Temperature Range | −5°C to 300°C |
| Carrier Gas Requirements | Argon, Helium, or Nitrogen (inert only) |
| Brand | KA |
|---|---|
| Origin | Canada |
| Model | KA6000 |
| Repeatability | <1% |
| Detection Limit | 1 ppb |
| Detector Type | Enhanced Plasma Discharge Detector (EPD) |
| Column Oven Temperature Range | −5 °C to 300 °C |
| Carrier Gases | N₂, Ar, He |
| Compliance | Fully compatible with ASTM D7622, ISO 8573-5, USP <467>, and EPA Method TO-15/TO-17 workflows |
| Software | Embedded GC control platform with 21 CFR Part 11–compliant audit trail and GLP/GMP data integrity architecture |