Autosense
Filter
Showing all 12 results
| Brand | Autosense |
|---|---|
| Membrane Materials | Mixed Cellulose Ester (MCE) & Polyvinylidene Fluoride (PVDF) |
| Available Diameters | 13 mm, 25 mm, 50 mm |
| Pore Sizes | 0.18 µm, 0.22 µm, 0.45 µm, 0.8 µm, 1.2 µm |
| Pack Size | 100 units per pack |
| Compliance | ISO 9001-manufactured |
| Brand | Autosense |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | APTC Series |
| Quotation | Available Upon Request |
| Temperature Range | 25°C below ambient to 80°C |
| Setpoint Range | 2°C to 70°C |
| Temperature Accuracy | ±0.5°C |
| Temperature Stability | ±0.2°C |
| Power Consumption | 180 W |
| Electrical Supply | 220 V AC, 50 Hz |
| Dimensions (W×H×D) | 220 × 185 × 282 mm |
| Net Weight | 6.5 kg |
| Brand | Autosense |
|---|---|
| Model | APTC-2 |
| Temperature Range | 25°C below ambient to 80°C |
| Setpoint Range | 2–70°C |
| Temperature Stability | ±0.2°C |
| Control Accuracy | ±0.5°C |
| Power Consumption | 180 W |
| Input Voltage | 220 V ±10%, 50 Hz |
| Dimensions (W×H×D) | 220 × 185 × 282 mm |
| Weight | 6.5 kg |
| Brand | Autosense |
|---|---|
| Model | AT-330 |
| Origin | Tianjin, China |
| Heating Method | Silicone Rubber Flexible Heater (WATLOW) |
| Temperature Control Accuracy | ±0.1 °C |
| Display | Dual 4-digit LED (Setpoint & Actual) |
| Mounting Options | Vertical or Horizontal Orientation |
| Chamber Access | Magnetic-latch Lid with Tempered Glass Viewing Window |
| Column Capacity | 1–2 columns (stainless steel spring-mounted brackets) |
| Leak Containment | Removable Drip Tray |
| Structural Stability | Optional Wide Base Plate for Vertical Configuration |
| Inlet/Outlet Routing | Chamfered Fluid Path Openings |
| Valve Mounting | Adjustable Height Injection Valve Bracket |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | Autosense |
|---|---|
| Model | ATP-3200 |
| Flow Rate Range | 0.25–2060 mL/min (dependent on tubing size) |
| Speed Range | 1–460 rpm, continuously adjustable |
| Speed Resolution | 0.1 rpm |
| Speed Stability | ≤ ±0.3 rpm |
| Tubing Compatibility | 14#, 16#, 25#, 17#, 18# (Pharmed®/Norprene®-equivalent silicone or thermoplastic elastomer tubing) |
| Max Fluid Pressure | 1.5 kg/cm² (≈147 kPa) |
| Operating Temperature | –10°C to 100°C (fluid), 0°C to 50°C (ambient) |
| Relative Humidity | <80% RH |
| Power Supply | 220 V ±15%, 50/60 Hz |
| Power Consumption | 150 W |
| Dimensions (W×H×D) | 120 × 230 × 270 mm |
| Net Weight | 5.5 kg |
| Direction Control | Forward/Reverse |
| Display | 4-digit LED, showing speed and flow (for three standard tubing sizes) |
| External Interface | TTL/RS-232-compatible control port for programmable automation |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Autosense |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FB-04T |
| Capacity | 30 mL |
| Filter Diameter | 25 mm |
| Components | Filter Funnel (30 mL), Central Filter Holder, Vacuum Filtration Flask, Aluminum Clamp Set |
| Price Range | USD 140 – 1,400 |
| Brand | Autosense |
|---|---|
| Origin | Tianjin, China |
| Model | MTN-2800D |
| Heating Method | Dry-block heating |
| Temperature Range | Ambient +5°C to 180°C |
| Temperature Stability | ±0.1°C |
| Sample Tube Diameter Compatibility | 10–30 mm |
| Nitrogen Flow Rate | 0–15 mL/min |
| Sample Positions | 12 / 24 / 40 |
| Heating Power | 350 W |
| Brand | Autosense |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MTN-2800D |
| Heating Method | Dry-block heating |
| Temperature Range | +5°C to 180°C |
| Temperature Stability | ±0.1°C |
| Sample Tube Diameter Compatibility | 10–30 mm |
| Nitrogen Flow Rate | 0–15 mL/min |
| Sample Positions | 12 |
| Heating Power | 350 W |
| Block Dimensions (Standard) | 95 W × 70 H × 75 L mm |
| External Dimensions (excl. support rod) | 240 W × 130 H × 215 D mm |
| Operating Ambient Temperature | 5–35°C |
| Power Supply | 220 V / 50 Hz |
| Safety Protections | Dual-mode overtemperature protection (upper-limit setpoint or deviation-based), integrated spill containment tray, continuous-duty thermal architecture |
| Brand | Autosense |
|---|---|
| Origin | Tianjin, China |
| Model | MTN-2800W |
| Heating Method | Water Bath |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Stability | ±0.1°C |
| Tube Diameter Compatibility | 13–19 mm |
| Nitrogen Flow Rate | 0–15 L/min |
| Sample Positions | 12 / 24 / 40 |
| Heating Power | 350 W |
| Over-Temperature Protection | 110°C |
| Timer Range | 0–99 h 59 min |
| Display | Dual digital display for set/actual temperature and timer modes (count-up/count-down) |
| Dimensions (W×H×D, main unit only) | 240 × 130 × 215 mm |
| Heating Block Size | 210 × 95 × 150 mm |
| Power Supply | 220 V / 50 Hz |
| Brand | Autosense |
|---|---|
| Origin | Tianjin, China |
| Model | MTN-2810D |
| Heating Method | Dry-block heating |
| Temperature Range | Ambient +5°C to 300°C |
| Temperature Stability | ±0.1°C |
| Sample Capacity | 8 or 12 positions |
| Tube Diameter Compatibility | 10–29 mm |
| Nitrogen Flow Rate | 0–15 L/min |
| Heating Power | 1350 W |
| Timer Range | 10 min to 99 h 59 min |
| Over-Temperature Protection | Dual-mode (upper-limit & deviation-based) |
| Temperature Output Interface | Analog signal output (0–5 V or 4–20 mA, configurable) |
| Dimensions (W×L×H, excluding support rod) | 268 × 230 × 165 mm |
| Operating Ambient | 5–35°C |
| Power Supply | 220 V / 50 Hz |
| Brand | Autosense |
|---|---|
| Origin | Tianjin, China |
| Model | MTN-5800D Electric |
| Heating Method | Water Bath |
| Temperature Range | Ambient to 96 °C (water) |
| Temperature Stability | ±0.2 °C |
| Sample Capacity | 12-position (for vessels Φ30–55 mm) / 24-position (for tubes Φ10–29 mm) |
| Gas Flow Rate | 0–25 L/min (adjustable) |
| Heating Power | 1000 W |
| Vertical Travel | Sample Tray 0–100 mm |
| Internal Tank Dimensions | Φ320 × H170 mm |
| Overall Dimensions | Φ355 × L402 × H620 mm |
| Display | LCD |
| Gas Consumption per Needle | 330 mL/min |
| Water Level Sensor | Integrated with auto-shutoff and alarm |
| Drain Valve | Yes |
| Needle Options | Disposable polypropylene or stainless steel |
| Flow Visualization | Float-type gas flow meter |
| Sample Holder Rotation | 360° continuous |
| Brand | Autosense |
|---|---|
| Model | WB Series |
| Temperature Range | Ambient to 90 °C |
| Temperature Stability | ±0.2 °C |
| Temperature Setting Resolution | 0.1 °C |
| Over-Temperature Protection Range | 25–130 °C |
| Heating Power | 1000 W |
| Oscillation Frequency | 40–100 Hz/min |
| Oscillation Amplitude | 18 mm (horizontal) |
| Bath Capacity | 20 L |
| External Dimensions | 600 mm × 300 mm × 300 mm (W × D × H) |
| Timer Range | 10–90 min |
| Display | Dual 4-digit LED (set & actual temperature) |