| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LDS-L1 |
| Price Range | USD 14,000 – 28,000 |
| Minimum Sample Volume | 30 mL |
| Pressure Range | −1 to 5 bar |
| Flow Rate Range | 1–2200 mL/min |
| Weight Capacity | 0–4100 g |
| Displayed Parameters | Pf (Feed Pressure), Pr (Retentate Pressure), Pp (Permeate Pressure), TMP (Transmembrane Pressure), ΔP (Pressure Drop) |
| Operation Mode | Manual |
| Compatible Vessels | Glass or Stainless Steel Containers |
| Membrane Formats | PES or Cellulose-Based Cassettes & Hollow Fiber Modules |
| MWCO Options | 5–1000 kDa |
| Effective Filtration Area | 0.01–0.1 m² |
| Compliance | Designed for GLP-compliant lab-scale process development and tech transfer |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LDS-L1 |
| Pricing | Upon Request |
| Minimum Sample Volume | ≤30 mL |
| Pressure Range | −1 to 5 bar |
| Max Flow Rate | ≥2200 mL/min |
| Weight Capacity | 0–4100 g |
| Weighing Accuracy | ±0.5% |
| Measured Parameters | Pf (Feed Pressure), Pr (Retentate Pressure), Pp (Permeate Pressure), TMP (Transmembrane Pressure), ΔP (Pressure Drop) |
| Compatible Membranes | PES and Cellulose-based Cassettes & Hollow-Fiber Modules |
| MWCO Range | 5–1000 kDa |
| Effective Membrane Area | 0.01–0.1 m² |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LDS-L1 |
| Pricing | Upon Request |
| Minimum Sample Volume | ≤30 mL |
| Pressure Range | −1 to 5 bar |
| Max. Permeate Flow Rate | ≥2200 mL/min |
| Weight Capacity | 0–4100 g |
| Weighing Accuracy | ±0.5% |
| Real-time Monitored Parameters | Pf (Feed Pressure), Pr (Retentate Pressure), Pp (Permeate Pressure), TMP (Transmembrane Pressure), ΔP (Pressure Drop) |
| Compatible Membrane Formats | PES & Cellulose-based Cassettes and Hollow Fiber Modules |
| MWCO Range | 5–1000 kDa |
| Effective Filtration Area | 0.01–0.1 m² |
| Compliance | FDA 21 CFR Part 11 Audit Trail Ready, Designed for GLP/GMP-adjacent R&D Environments |
| Brand | AITESEN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LDS-L2 |
| Quotation | Upon Request |
| Minimum Sample Volume | ≤30 mL |
| Pressure Range | −1 to 5 bar (with integrated pressure sensors) |
| Maximum Recirculation Flow Rate | ≥2200 mL/min |
| Weight Measurement Accuracy | ±0.5% (0–4100 g) |
| Controlled Parameters | Pf (Feed Pressure), Pr (Retentate Pressure), Pp (Permeate Pressure), TMP (Transmembrane Pressure), ΔP (Pressure Drop) |
| Operation Mode | Fully Automated PLC-Controlled TFF |
| Compatible Membranes | PES and Cellulose-based Cassettes & Hollow Fiber Modules (MWCO: 5–1000 kDa |
| Effective Filtration Area | 0.01–0.1 m²) |
| Software Compliance | FDA 21 CFR Part 11–compliant audit trail, role-based access control (Operator / Process Engineer / Administrator) |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LDS-L2 |
| Pricing | Available Upon Request |
| Minimum Sample Volume | 30 mL |
| Pressure Range | −1 to 5 bar |
| Flow Rate Range | 1–2200 mL/min |
| Weight Capacity | 0–4100 g |
| Measurable Parameters | Pf (Feed Pressure), Pr (Retentate Pressure), Pp (Permeate Pressure), TMP (Transmembrane Pressure), ΔP (Pressure Drop) |
| Operation Mode | Fully Automated |
| Compatible Vessels | Glass & Stainless Steel Containers |
| Membrane Formats | PES & Cellulose-Based Cassettes, Hollow Fiber Modules |
| MWCO Range | 5–1000 kDa |
| Effective Membrane Area | 0.01–0.1 m² |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LDS-L2 |
| Pricing | Upon Request |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LDS-L2 |
| Quotation | Upon Request |
| Minimum Sample Volume | ≤30 mL |
| Pressure Range | −1 to 5 bar (with integrated pressure sensors) |
| Maximum Peristaltic Flow Rate | ≥2200 mL/min |
| Weight Measurement Accuracy | ±0.5% (0–4100 g) |
| Controlled Parameters | Pf (Feed Pressure), Pr (Retentate Pressure), Pp (Permeate Pressure), TMP (Transmembrane Pressure), ΔP (Pressure Drop) |
| Operation Mode | Fully Automated PLC-Controlled TFF |
| Compatible Membranes | PES and Cellulose-based Cassettes & Hollow Fiber Modules (MWCO: 5–1000 kDa |
| Effective Area | 0.01–0.1 m²) |
| Software Compliance | FDA 21 CFR Part 11 Audit Trail Enabled |
| User Access Levels | Three-Tier Password Protection (Operator / Process Engineer / Administrator) |
| Brand | Autoscience |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SRJ-20A |
| Input Signal Range | 10 mV / 100 mV / 1 V |
| Valve Delay Time | 10–90 s |
| Maximum Flow Rate | 50 mL/min (through 1/16" tubing) |
| Display | Dual-color (red/green) LCD |
| Zero Adjustment | Auto-zero tracking baseline drift |
| Power Supply | 13.5 V / 500 mA |
| Dimensions (L×W×H) | 14.2 × 18.5 × 6.28 cm |
| Weight | 1.0 kg |
| Brand | Autosense |
|---|---|
| Membrane Materials | Mixed Cellulose Ester (MCE) & Polyvinylidene Fluoride (PVDF) |
| Available Diameters | 13 mm, 25 mm, 50 mm |
| Pore Sizes | 0.18 µm, 0.22 µm, 0.45 µm, 0.8 µm, 1.2 µm |
| Pack Size | 100 units per pack |
| Compliance | ISO 9001-manufactured |
| Brand | Autosense |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FB-04T |
| Capacity | 30 mL |
| Filter Diameter | 25 mm |
| Components | Filter Funnel (30 mL), Central Filter Holder, Vacuum Filtration Flask, Aluminum Clamp Set |
| Price Range | USD 140 – 1,400 |
| Brand | Autosience |
|---|---|
| Model | AL-01 |
| Construction | Borosilicate glass filtration assembly (FB-10T, 1000 mL capacity) with sintered glass frit (porosity: 10–16 µm) |
| Vacuum source | AP-01P oil-free diaphragm vacuum pump (ultimate vacuum: ≤70 mbar, flow rate: 25 L/min) |
| Optional upgrade | FB-20T 2000 mL filtration kit |
| Filtration volume per cycle | 300 mL (funnel capacity) |
| Compatibility | Standard 29/32 and 45/50 joint sizes for interchangeability with major international brands (e.g., Whatman, Millipore, Thermo Fisher) |
| Regulatory alignment | Designed for GLP-compliant lab environments |
| Brand | Beiyu Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BCL-100 |
| Power Source | Rechargeable Lithium-ion Battery (20 h runtime) |
| Weight | 5 kg |
| Filtration Membrane | 0.45 µm Hydrophilic Membrane (Aqueous Phase) |
| Sample/Bottle Capacity | 600 mL |
| Vacuum Pump | Corrosion-Resistant Imported Diaphragm Pump |
| Display | LCD Battery Level Indicator |
| Bottle Material | Metal-Ion-Free Polymer Compliant with Chinese National Standards (e.g., HJ 489–2009, HJ 490–2009) |
| Membrane Replacement | Tool-Free Quick-Release Mechanism |
| Brand | Cytiva |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Membrane Area Compatibility | 0.1–2.5 m² (cassette & hollow-fiber modules) |
| Predefined Process Programs | UF Production, Normalized Water Permeability (NWP), Clean-in-Place (CIP), Water Rinse, Alkaline Hold |
| Regulatory Alignment | Designed to support GMP, FDA 21 CFR Part 11, and EU Annex 11 compliance requirements |
| Software Architecture | Embedded control with audit trail, user access levels, and electronic signature capability |
| System Flexibility | Modular configuration for lab-scale development, pilot-scale process validation, and small-batch cGMP manufacturing |
| Brand | Cytiva |
|---|---|
| Origin | Manufactured in China under Cytiva’s global quality system |
| Manufacturer Type | Authorized Distributor |
| Model | Agile flux TFF Systems |
| Pricing | Available upon request |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | AKTA crossflow |
| Application Range | 25 mL – 50 L |
| Pump Flow Rate (Feed) | Up to 600 mL/min |
| Pump Flow Rate (Permeate/Retentate) | Up to 200 mL/min |
| Membrane Area Capacity | Up to 0.1 m² |
| Control Software | UNICORN™ v7.x or later |
| Compliance | FDA 21 CFR Part 11, USP <1211>, ISO 13485, GMP/GLP-ready |
| Sanitization | Validated NaOH (1 M) CIP, ≥6-log reduction in microbial challenge testing |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA flux 6 |
| Configuration | Semi-automated TFF platform |
| Application Scope | Concentration, diafiltration, cell harvest & clarification |
| Membrane Compatibility | Hollow-fiber modules & cassette-type membrane packs |
| Operating Volume Range | 50 mL – 6 L |
| Control Interface | Integrated touchscreen with real-time parameter monitoring |
| Data Logging | Onboard process recording (time-stamped, user-ID traceable) |
| Regulatory Support | Compliant with FDA 21 CFR Part 11 audit trail requirements for GMP-relevant workflows |
| Service Framework | OptiRun lifecycle support program |
| Change Notification | Web-based Change Control Notification (CCN) service |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA flux 6 |
| Application Scope | Process Development & Small-Scale Production |
| Control Mode | Automated Endpoint & Constant Retentate Volume (CRV) |
| Data Handling | Real-Time Logging with Audit-Trail-Capable Software |
| Regulatory Compliance | Designed for GMP Environments |
| Installation & Qualification | IQ/OQ Support Available by Certified Engineers |
| User Interface | Integrated Touchscreen HMI |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | AKTA flux |
| Application Scope | Research, Filter Screening, Process Development, and Small-Scale Production |
| Control Mode | Semi-Automated with Endpoint & Constant Retentate Volume (CRV) Control |
| User Interface | Touchscreen HMI with Real-Time Process Monitoring & Data Logging |
| Membrane Compatibility | Hollow-Fiber Modules and Cassettes |
| Regulatory Support | IQ/OQ Documentation Available via Fast Trak Validation™ Service |
| Compliance Context | Designed to support GLP/GMP environments |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA flux s |
| Application Scope | Research & Membrane Screening |
| Control Mode | Automated Endpoint Control, Constant Retentate Volume (CRV) Mode |
| User Interface | 7-inch High-Resolution Touchscreen with Real-Time Process Monitoring |
| Data Handling | Onboard Logging (CSV Export), Audit-Trail-Ready Event History |
| Compliance Context | Designed for GLP-compliant workflows |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA readyflux |
| Type | Single-Use Tangential Flow Filtration (TFF) System |
| Application Scope | Lab-Scale to Pilot-Scale Bioprocessing |
| Control Software | UNICORN 7.x or later |
| Compatibility | DeltaV™ DCS, ReadyToProcess Hollow-Fiber Cartridges, Xcellerex XDUO Single-Use Mixers, Third-Party Bag Mixers |
| Regulatory Alignment | Designed for GLP/GMP environments |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | UniFlux Tangential Flow Filtration System |
| Flow Rate Options | 10, 60, 120 L/min (400 L/min available on custom basis) |
| Vessel Capacity Range | 5–600 L (stainless steel or single-use mixing systems supported) |
| Automation Platform | UNICORN Software (21 CFR Part 11 compliant) |
| Application Scope | Microfiltration (e.g., cell harvest) and Ultrafiltration (e.g., protein concentration & diafiltration) |
| Brand | Autoscience |
|---|---|
| Origin | Tianjin, China |
| Model | FB-05T |
| Capacity | 500 mL |
| Components | Filter Funnel (with Sintered Frit Disc), Aluminum Clamp, Collection Bottle |
| Configuration | Single-unit vacuum filtration system for sterile or particulate removal applications |
| Brand | Autoscience |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FB-10T |
| Price Range | USD 140 – 1,400 |
| Capacity | 1000 mL Collection Bottle |
| Components | Filter Funnel (with Standard Taper Joint), Sintered Glass Frit Disc (Porosity Grade G3 or G4, Ø47 mm), Filter Clamp Assembly, 1000 mL Heavy-Wall Borosilicate Glass Collecting Flask with Graduated Scale and PTFE-Coated Stopcock |
| Brand | Autoscience |
|---|---|
| Origin | Tianjin, China |
| Model | FB-20T |
| Capacity | 2000 mL |
| Components | Filter Funnel (with Standard 47 mm or 90 mm Filter Support), Sintered Stainless Steel Fritted Disc (Porosity Grade: G3 or G4, Optional), Anodized Aluminum Clamp Assembly, Heavy-Wall Borosilicate Glass Collection Bottle (Class A, ASTM E438 Type I, Class B Thermal Shock Resistance) |
| Material Compliance | USP <661.1> Compliant Glass & FDA-Approved Anodized Aluminum |
| Sterilization Compatibility | Autoclavable (121°C, 20 min, 15 psi) |
| Brand | Fitlylab |
|---|---|
| Origin | Guangdong, China |
| Model | W1 |
| Material | Fully Stainless Steel (316L-grade components) |
| Filter Cup Diameter | φ47 mm or φ50 mm |
| Membrane Pore Size | 0.22 µm or 0.45 µm |
| Configuration | Triple-station with independent valve control per station |
| Sterilization Compatibility | Autoclavable (121 °C, 20 min, steam) |
| Compliance | Designed for ISO 7218, ASTM D5673, and USP <61> microbiological testing workflows |
| Includes | Stainless steel filtration cups, stainless steel support screens, stainless steel manifold支架, stainless steel isolation valves, anodized aluminum clamps, silicone tubing, overflow-prevention collection flask, vacuum pump interface |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | Bio-TFF 180–30000 |
| Price Range | USD 28,000 – 70,000 |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | MS-3 |
| Construction Material | Electropolished 316L Stainless Steel |
| Sample Capacity | 3 Independent Filter Positions |
| Dimensions (L×W×H) | 494 × 110 × 118 mm |
| Connection Type | Standard #9 Rubber Stopper Interface for Glass or Stainless Steel Membrane Filter Holders |
| Vacuum Compatibility | Single Central Vacuum Source Required |
| Pricing | USD 795 (FOB Shanghai) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MS-6 |
| Price | USD 985 (excl. VAT & shipping) |
| Material | Electropolished 316L Stainless Steel Frame |
| Dimensions (L×W×H) | 914 × 110 × 118 mm |
| Sample Capacity | 6 independent filtration stations |
| Connection Interface | Standard #9 rubber stopper ports for glass or stainless steel membrane filter holders |
| Individual Valve Control | Yes, per station |
| Structural Design | Low-center-of-gravity base with anodized aluminum dual-handled support frame |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Models | FB-01T (1000 mL), FB-02T (2000 mL) |
| Price Range | USD 140 – 1,400 |
| Brand | HengAo |
|---|---|
| Model | HSF-G3 / HSF-G6 |
| Construction | 316L Stainless Steel Support Frame & Borosilicate Glass Filtration Units |
| Configuration | 3- or 6-position parallel filtration stations |
| Filtration Principle | Vacuum-assisted membrane filtration (negative pressure-driven) |
| Compliance | Meets ISO 7218:2017 (Microbiology of food and animal feeding stuffs — General requirements and guidance for microbiological examinations), USP <61> & <62>, and ASTM D5465-22 (Standard Test Method for Determination of Total Coliforms and Escherichia coli in Water by Membrane Filtration) |
| Sterilization Compatibility | Autoclavable (121 °C, 20 min) and compatible with ethylene oxide (EtO) and vaporized hydrogen peroxide (VHP) decontamination protocols |
| Operating Pressure Range | −0.08 to −0.1 MPa (adjustable via individual inline valves) |
| Filter Diameter | 47 mm standard |
| Maximum Sample Volume per Station | 500 mL |
| Material Certifications | FDA-compliant silicone gaskets |
| Data Integrity | Designed for GLP/GMP environments with optional audit-trail-enabled vacuum controller integration |