| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-Film, Bismuth-Film, Bare Carbon |
| Max Simultaneous Channels | 2 modules × 5 elements each |
| Output Interfaces | 8 × 4–20 mA analog outputs, RS-485, RS-232 |
| Compliance Support | Designed for ASTM D3559, ISO 11929 (uncertainty evaluation), USP <232>/<233>, EPA Method 7000B (ASV-based), GLP/GMP-ready data logging |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-Film, Bismuth-Film, Bare Carbon |
| Max Modules | 2 |
| Simultaneous Parameters per Module | Up to 5 |
| Analog Outputs | 8 × 4–20 mA |
| Digital Interfaces | RS-485, RS-232 |
| Compliance | Designed for EPA Method 7063, ISO 11969, ASTM D3559, and GLP/GMP-aligned data integrity protocols |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Measurement Principle | 90° White Light (WL) & Near-Infrared (NIR) Scattering |
| Range | 0–1000.0 NTU / 0–100 NTU |
| Accuracy | ±2% of reading or ±0.02 NTU (whichever is greater) for <40 NTU |
| Resolution | 0.0001 NTU (selectable, <10 NTU) |
| Response Time | 5–500 s (adjustable) |
| Light Sources | White LED (7-year lifetime), NIR LED (10-year lifetime) |
| Display | Multi-line backlit LCD |
| Analog Output | 4–20 mA (loop-powered, max 600 Ω load) |
| Digital Interface | RS-485, Modbus RTU |
| Alarm Outputs | Two programmable relays (120–240 VAC, 2 A) |
| Max Operating Pressure | 1380 kPa (with integrated pressure regulator) |
| Flow Rate | 100 mL/min – 1 L/min |
| Sample Temperature Range | +1 °C to +50 °C |
| Compliance | EPA Method 180.1, ISO 7027, EN ISO 7027 |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Measurement Range | 0–100 NTU and 0–1000 NTU |
| Measurement Principle | 90° White Light (WL) and 90° Near-Infrared (NIR) Scattering per USEPA Method 180.1 and ISO 7027 |
| Accuracy | ±2% of reading or ±0.02 NTU (whichever is greater) for <40 NTU |
| Resolution | 0.0001 NTU (selectable, applicable below 10 NTU) |
| Response Time | 5–500 s (user-adjustable) |
| Light Source Lifetime | 7 years (white LED), 10 years (NIR LED) |
| Operating Temperature | +1 °C to +50 °C |
| Sample Flow Rate | 100 mL/min to 1 L/min |
| Max Inlet Pressure | 1380 kPa (integrated pressure regulator) |
| Display | Backlit multi-line LCD |
| Analog Output | Isolated 4–20 mA (600 Ω max load) |
| Digital Interface | Bidirectional RS-485 with Modbus RTU protocol |
| Alarm Outputs | Two programmable relays (120–240 VAC, 2 A) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Measurement Range | 0–10 mg/L Cl₂ |
| Cycle Time | 110 s–10 min (adjustable) |
| Accuracy | ±5% or ±0.03 mg/L Cl₂ (0–6 mg/L) |
| Resolution | 0.01 mg/L |
| Method | EPA-approved DPD colorimetric analysis for free chlorine and total chlorine |
| Output | 4–20 mA analog + RS-485 with Modbus RTU protocol |
| Alarms | Two user-configurable concentration-based digital alarms |
| Operating Temperature | 5–40 °C |
| Inlet Pressure | 5–150 psi |
| Enclosure Rating | NEMA 4X / IP66 |
| Housing Material | ABS plastic |
| Power Supply | 100–240 V AC, auto-ranging, 47–63 Hz |
| Certifications | CE, UL, CSA, ETL, ETLc |
| Dimensions (L×W×H) | 41 × 41 × 26 cm |
| Weight | 3.6 kg |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Measurement Range | 0–10 mg/L Cl₂ |
| Cycle Time | 110 s – 10 min (user-selectable) |
| Accuracy | ±5% or ±0.03 mg/L Cl₂ (whichever is greater) for 0–6 mg/L |
| Resolution | 0.01 mg/L |
| Method | EPA-Approved DPD Colorimetric Analysis |
| Output | 4–20 mA analog + RS-485 with Modbus RTU protocol |
| Alarms | Two user-configurable concentration-based digital alarms |
| Operating Temperature | 5–40 °C |
| Inlet Pressure | 5–150 psi |
| Enclosure Rating | NEMA 4X / IP66 |
| Housing Material | ABS plastic |
| Power Supply | 100–240 V AC, auto-ranging, 47–63 Hz |
| Certifications | CE, UL, CSA, ETL, ETLc |
| Dimensions (L×W×H) | 41 × 41 × 26 cm |
| Weight | 3.6 kg |
| Brand | AVVOR |
|---|---|
| Model | 9000-1 |
| Origin | Fujian, China |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Range | 0.1–5 mg/L (standard), optional 0–20 / 0–50 / 0–100 mg/L |
| Detection Limit | 0.1 mg/L |
| Accuracy | ±0.1 mg/L |
| Repeatability | ±0.5% RSD |
| Resolution | 0.1 mg/L |
| Cycle Time | 30 min per analysis |
| Compliance | GB 11892–1989, HJ/T 100–2003 |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000-CODmn |
| Measurement Method | Potassium Permanganate Oxidation–Redox Titration (ISO 8467, GB 11892–1989, HJ/T 100–2003) |
| Range | 0–20 mg/L (standard), optional 0–50 mg/L and 0–100 mg/L |
| LOD | 0.05 mg/L |
| Resolution | 0.01 mg/L |
| Accuracy | ≤ ±3% |
| Sample Matrix | Drinking water and surface water with chloride < 300 mg/L |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | AVVOR |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | AVVOR 9000 NH4-N |
| Instrument Type | Online Analyzer |
| Measurement Principle | Ammonia Gas-Sensing Electrode Method |
| Measurement Range | 0.05–1000 mg/L (multi-range configurable) |
| Accuracy | ±3% FS |
| Detection Limit | 0.01 mg/L |
| Measurement Cycle | 5 min per sample |
| Batch Capacity | 10 samples |
| Compliance | HJ/T 101–2003 (China EPA Standard) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LawLink |
| Pricing | Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Baihaitun RiverPro |
| Depth Measurement Range | 0.12–25 m |
| Compatible Platform | Shared buoy system with RiverRay ADCP |
| Electronics Architecture | Next-generation modular electronics platform (upgradable to RiverRay units) |
| Brand | AVVOR |
|---|---|
| Origin | Germany |
| Model | TresCon OA110 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Ammonia-Selective Gas-Sensing Electrode |
| Measurement Range | 0.01–2 mg/L NH₄–N |
| Accuracy | ±0.5% of reading |
| Detection Limit | 0.1 mg/L NH₄–N |
| Cycle Time | 30 min |
| Batch Capacity | 10 samples per cycle |