| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Haze 3001 |
| Form Factor | Benchtop / Laboratory |
| Measurement Range | 0–400 NTU |
| Resolution | 0.01 NTU |
| Operating Ambient Temperature | 15–35 °C |
| Brand | APURE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | A10TR-AA1 |
| Price | USD 195 (FOB Shanghai) |
| Instrument Type | Online Turbidimeter |
| Measurement Ranges | 0–20 NTU, 0–400 NTU, 0–4000 NTU (custom ranges available) |
| Resolution | 0.01 NTU |
| Operating Temperature | 0–60 °C |
| Accuracy | ±1.0 % FS |
| Temperature Compensation | 0–100 °C (manual or automatic) |
| Output Signals | Isolated 4–20 mA (max. load 500 Ω), assignable to turbidity or temperature |
| Relay Outputs | 3 × SPDT relays (3 A / 250 V AC, NO contact), programmable high/low alarm thresholds with adjustable hysteresis |
| Power Supply | AC 220 V ±10 % / 50–60 Hz or DC 24 V ±10 % |
| Power Consumption | ≤7 W |
| Enclosure Dimensions | 96 × 96 × 132 mm (H × W × D) |
| Panel Cutout | 92.5 × 92.5 mm |
| Environmental Rating | IP65 front panel |
| Relative Humidity | ≤85 % RH (non-condensing) |
| Brand | Apure |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | TS-620 |
| Price | USD 685 (FOB Shanghai) |
| Product Type | Online |
| Measurement Range | Low-Turbidity Mode (0–0.5 NTU & 5–400 NTU) |
| Resolution | 0.01 NTU (low-turbidity), 0.1 NTU (high-turbidity) |
| Operating Temperature (Transmitter) | –20 to +55 °C |
| Accuracy | ±5% FS |
| Enclosure Rating | Transmitter IP65 |
| Process Pressure (Submersible) | ≤0.3 MPa |
| Output | 4–20 mA (4-wire, max. load 750 Ω) |
| Relay Outputs | 2 programmable SPDT relays (AC230 V, 2 A) |
| Digital Interface | RS485 with Modbus RTU protocol |
| Humidity | ≤85% RH (non-condensing) |
| Brand | AQUALABO |
|---|---|
| Origin | France |
| Model | NTU |
| Type | Online Turbidity Sensor |
| Measurement Range | 0–4000 NTU |
| Resolution | 0.01 NTU |
| Accuracy | ±5% of reading |
| Operating Temperature | 0–50 °C |
| Output Protocols | Modbus RTU over RS-485 (standard), SDI-12 (optional) |
| Enclosure Rating | IP68 |
| Power Supply | 5–12 V DC |
| Typical Current Consumption | 820 µA (RS-485, 1 Hz), 4.2 mA (SDI-12, 1 Hz) |
| Dimensions | Ø27 mm × 170 mm (sensor + 3 m cable) |
| Weight | 300 g |
| Pressure Rating | 5 bar |
| Optical Principle | 90° infrared scattered light nephelometry at 850 nm |
| Calibration Standard | Formalin-based turbidity standards per NF EN 872 (0–500 mg/L) and NF T 90-105-2 (>500 mg/L) |
| Brand | AQUALABO |
|---|---|
| Origin | France |
| Model | NTU |
| Measurement Principle | 90° Infrared Light Scattering at 880 nm |
| Turbidity Range | 0–4000 NTU (5 selectable sub-ranges) |
| TSS Range | 0–4500 mg/L |
| Resolution | 0.01–1 NTU / mg/L |
| Accuracy | < ±5% of reading |
| Temperature Compensation | Integrated CTN sensor (±0.5 °C) |
| Output | Modbus RTU over RS-485 (standard), SDI-12 (optional) |
| Power Supply | 5–12 VDC |
| Typical Current Draw | 820 µA (RS-485, 1 Hz) |
| Peak Pulse | 500 mA |
| Enclosure Material | PVC, Delrin®, Quartz, PMMA, Polyamide |
| Dimensions | Ø27 mm × 170 mm |
| Weight | 300 g (sensor + 3 m cable) |
| Pressure Rating | 5 bar |
| IP Rating | IP68 |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −10 to +60 °C |
| Calibration Standards | NF EN 872 (0–500 mg/L), NFT 90 105-2 (>500 mg/L) |
| Max Refresh Rate | < 1 s |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | AS3 |
| Price | Upon Request |
| Operating Pressure | Up to 20 bar |
| Sensor Max Temp | 90°C (110°C with air cooling) |
| Hazardous Area Options | ATEX Zone 1 & Zone 2 / UL Class I Div 1 |
| Sensor Length | ~300 mm (custom lengths available) |
| Measurement Range | 0–5 NTU to 0–5,000 NTU |
| Accuracy | ±1% of reading |
| Transducer Frequencies | 5 MHz and 15 MHz |
| Enclosure Rating | NEMA 4X / IP65 |
| Process Integration | Ball-valve-mounted insertion probe |
| Compatibility | AT3 interface |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Measurement Principle | 90° White Light (WL) & Near-Infrared (NIR) Scattering |
| Range | 0–1000.0 NTU / 0–100 NTU |
| Accuracy | ±2% of reading or ±0.02 NTU (whichever is greater) for <40 NTU |
| Resolution | 0.0001 NTU (selectable, <10 NTU) |
| Response Time | 5–500 s (adjustable) |
| Light Sources | White LED (7-year lifetime), NIR LED (10-year lifetime) |
| Display | Multi-line backlit LCD |
| Analog Output | 4–20 mA (loop-powered, max 600 Ω load) |
| Digital Interface | RS-485, Modbus RTU |
| Alarm Outputs | Two programmable relays (120–240 VAC, 2 A) |
| Max Operating Pressure | 1380 kPa (with integrated pressure regulator) |
| Flow Rate | 100 mL/min – 1 L/min |
| Sample Temperature Range | +1 °C to +50 °C |
| Compliance | EPA Method 180.1, ISO 7027, EN ISO 7027 |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Measurement Range | 0–100 NTU and 0–1000 NTU |
| Measurement Principle | 90° White Light (WL) and 90° Near-Infrared (NIR) Scattering per USEPA Method 180.1 and ISO 7027 |
| Accuracy | ±2% of reading or ±0.02 NTU (whichever is greater) for <40 NTU |
| Resolution | 0.0001 NTU (selectable, applicable below 10 NTU) |
| Response Time | 5–500 s (user-adjustable) |
| Light Source Lifetime | 7 years (white LED), 10 years (NIR LED) |
| Operating Temperature | +1 °C to +50 °C |
| Sample Flow Rate | 100 mL/min to 1 L/min |
| Max Inlet Pressure | 1380 kPa (integrated pressure regulator) |
| Display | Backlit multi-line LCD |
| Analog Output | Isolated 4–20 mA (600 Ω max load) |
| Digital Interface | Bidirectional RS-485 with Modbus RTU protocol |
| Alarm Outputs | Two programmable relays (120–240 VAC, 2 A) |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | HBD5-Turb4210_90D |
| Price Range | USD 1,400–2,800 |
| Type | Portable |
| Measurement Range | 0–2000 FNU |
| Resolution | 1.0 FNU |
| Operating Temperature | −30 °C to +70 °C |
| Accuracy | ±2.0% of reading |
| Detection Principle | 90° Nephelometric Scattering (ISO 7027-compliant) |
| Display | 2×16 LCD |
| Keypad | 4×5 membrane keypad |
| Response Time | <1 ms |
| Power Supply | Rechargeable 9 V battery or external DC 9 V adapter |
| Battery Life | >10 hours continuous operation |
| Dimensions (H×W×D) | 180 mm × 98 mm × 35 mm |
| IP Rating | IP68 (fully submersible sensor probe) |
| Probe Interface | ZG1″ (BSPP) threaded fitting for in-line pipe insertion |
| Sample Compatibility | Clear to moderately turbid aqueous samples |
| Brand | BJBY (Beijing Baoyun) |
|---|---|
| Origin | Beijing, China |
| Model | BY-TC1100 |
| Type | Portable Turbidimeter |
| Measurement Principle | 90° Nephelometric Scattering |
| Range Options | 0–20 NTU / 0–200 NTU |
| Minimum Detectable Value | 0.01 NTU (0–20 range) / 0.1 NTU (0–200 range) |
| Accuracy | ±8% of reading (±2.5% F.S.) |
| Repeatability | ≤1% |
| Zero Drift | ±1% F.S. |
| Light Source | Long-life LED (90° scattering geometry) |
| Warm-up Time | ≤30 s |
| Power Supply | 9 V alkaline battery or AC/DC adapter (220 V AC / 50 Hz input |
| Dimensions | 235 × 75 × 65 mm |
| Display | Backlit LCD with microprocessor control |
| Auto Functions | Auto-zero, auto-calibration, auto-shutdown after 10 min inactivity |
| Data Interface | Analog/digital output port (RS-232 or TTL-level, configurable) |
| Compliance | ISO 7027:2016 (Nephelometric method for turbidity measurement) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | COH-300A |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | COH400 |
| Pricing | Available Upon Request |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Portable |
| Measurement Range | 0.05–100 NTU |
| Operating Temperature | 0–50 °C |
| Wavelength Range | 340–800 nm |
| Measurement Principle | Nephelometric (90° scattered light detection) |
| Accuracy | ≤5% FS |
| Repeatability | <0.5% |
| Stability | <0.5% |
| Light Source | Imported Cold LED (Lifespan ≥100,000 h) |
| Display | 3.5-inch Color TFT Touchscreen |
| Data Storage | >80,000 Records |
| Connectivity | USB Type-C, Wi-Fi, Bluetooth, Hotspot |
| Power | 5 V DC / 5600 mAh Li-ion Battery (12 h continuous operation) |
| Dimensions | 180 × 80 × 70 mm |
| Weight | 700 g |
| Compliance | GB/T 13200–1991, ISO 7027:2016 (Nephelometric Method) |
| Brand | Doctor Water |
|---|---|
| Origin | Hunan, China |
| Model | Dr-WCB |
| Type | Portable Turbidimeter |
| Measurement Range | 0–20 NTU / 0–200 NTU / 0–1000 NTU |
| Resolution | 0.001 Abs |
| Accuracy | ≤ ±5% |
| Repeatability | ≤ ±2% |
| Optical Stability | ≤ ±0.005 Abs/20 min |
| Wavelength Range | 330–900 nm |
| Wavelength Accuracy | ±5 nm |
| Operating Temperature | 0–50 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Power | Dual AC/DC supply |
| Display | 5-inch HD color capacitive touchscreen |
| Sample Format | 16 mm and 25 mm round cuvettes |
| Light Source | Imported long-life cold LED source (>100,000 h) |
| Data Storage | Up to 1,000,000 measurement records |
| Interface | USB Type-C (charging + data transfer) |
| Printing | Integrated thermal printer |
| Readout Modes | Turbidity (NTU), Absorbance (Abs) |
| Housing Material | Corrosion- and heat-resistant ABS |
| Brand | DoctorWater |
|---|---|
| Origin | Hunan, China |
| Model | Dr-WTB |
| Type | Benchtop/Laboratory |
| Measurement Range | 0–20 NTU / 0–200 NTU / 0–1000 NTU |
| Resolution | 0.001 Abs |
| Accuracy | ≤ ±5% |
| Wavelength Range | 330–900 nm |
| Wavelength Accuracy | ±5 nm |
| Repeatability | ≤ ±2% |
| Optical Stability | ≤ ±0.005 Abs/20 min |
| Display | 8-inch HD color capacitive touchscreen |
| Sample Holders | 360° rotatable cuvette holder & 25 mm fixed-position cuvette holder |
| Light Source | Imported long-life cold LED (≥100,000 h) |
| Calibration Modes | Blank, Factor, and Calibration Curve |
| Data Storage | Up to 1,000,000 measurements |
| Connectivity | USB interface |
| Print Output | Built-in thermal printer |
| Readout Units | NTU, Absorbance (Abs) |
| Housing Material | Corrosion- and heat-resistant ABS |
| Dimensions | 392 × 315 × 170 mm |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TB 1000 |
| Product Type | Portable |
| Measurement Range | 0.00–9.99 NTU |
| Resolution | 0.01 NTU (0–9.99 NTU) |
| Operating Temperature | 0–40 °C |
| Accuracy | ±2% of reading |
| Repeatability | ≤±1% of reading |
| Response Time | <6 s |
| Sample Volume | 30 mL |
| Light Source | Tungsten lamp (white light), compliant with US EPA Method 180.1 |
| Calibration | 1–3-point automatic calibration (standard points: 0.02, 10.0, 1000 NTU) |
| Calibration Accuracy | ±0.02 NTU at 0.02 NTU point |
| Data Output | RS232C interface |
| GLP Compliance | Date/time stamping, calibration expiry alerts, audit-ready data logging |
| Enclosure | ABS plastic housing |
| Power Supply | UL/CSA-certified 12 VDC regulated adapter |
| Dimensions (instrument) | 25.4 × 23.7 × 12.1 cm |
| Weight (instrument) | 1550 g |
| Packaging Dimensions | 35.5 × 31.5 × 25 cm |
| Gross Weight | 2380 g |
| Brand | GALVANIC |
|---|---|
| Origin | USA |
| Model | Monitek-MoniTurb |
| Type | Online Turbidimeter |
| Measurement Range | 0–500 NTU |
| Resolution | 0.1 NTU |
| Operating Temperature | −10°C to 50°C |
| Accuracy | ±1% |
| Protection Rating | IP65 / NEMA 4X |
| Hazardous Area Certification | ATEX Ex d IIC/T6 |
| Light Source | Gas-filled lamp (380–1100 nm), ~2-year lifetime |
| Flow Cell Material | Stainless steel (optional Ti, PTFE) |
| Viewing Window | Sapphire (optional borosilicate, acrylic) |
| Seals | FKM (optional FFKM, EPDM, silicone) |
| Process Connections | DIN, ANSI, NPT |
| Scattering Angles | 12° forward scatter and 90° side scatter |
| Data Logging Capacity | 8,000 entries |
| Communication | RS-232C / RS-485 (Modbus RTU) |
| Programmable Units | NTU, JTU, AU, EBC, ppm, g/L, %TS, Hazen, ASTM, Saybolt |
| Cleaning | CIP-compatible, optional spray nozzle |
| Calibration/Maintenance Interval | Up to 24 months (application-dependent) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Online Installation |
| Model | PM 820 2T |
| Measurement Principle | Infrared 90° Nephelometric Scattering (EN ISO 7027 Compliant) |
| Temperature Compensation Range | –10 to 130 °C (manual/automatic, NTC30k or PT1000 sensor support) |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language Support | English & Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS) |
| Digital Communication | RS485 Modbus RTU |
| Cleaning Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC, hysteresis configurable) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mount, pipe-mount, panel-mount |
| Dimensions (H×W×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM 8202T |
| Product Type | Online |
| Operating Temperature | −10 °C to +70 °C |
| Storage Temperature | −20 °C to +70 °C |
| Display | Backlit Graphic LCD |
| Communication | RS485 Modbus RTU |
| Analog Outputs | 2 × Isolated 4–20 mA (≤500 Ω, 0.1% FS) |
| Alarm Outputs | 2 × SPDT Relays (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable Interval (0.1–1000 h) & Duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall, Pipe, Panel |
| Dimensions | 144 × 144 × 108 mm |
| Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Temperature Compensation | −10 °C to +130 °C (NTC30K or PT1000 sensor input) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or Optional 24 VDC |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | PM8202 |
| Configuration | Online Fixed-Mount System |
| Measurement Range | 0.0–50.0 g/L |
| Resolution | 0.01 g/L |
| Operating Ambient Temperature | 0–60 °C |
| Accuracy | ±3% of full scale |
| Sensor Type | BSens 550 |
| Optical Principle | 90° Infrared Light Scattering |
| Sensor Housing Material | Stainless Steel |
| Cable Length | 7 m (standard) |
| Max. Process Pressure | 5 bar |
| Sensor IP Rating | IP68 |
| Controller IP Rating | IP65 |
| Display | Dot-matrix LCD with bilingual (English/Chinese) menu |
| Power Supply | 90–260 VAC, 50/60 Hz |
| Analog Outputs | Two isolated 4–20 mA outputs (sludge concentration & temperature), load ≤600 Ω |
| Digital Interface | RS485 Modbus RTU |
| Alarm Outputs | Two programmable relay outputs (5 A / 250 VAC), adjustable hysteresis |
| Cleaning Interval Setting | Field-configurable (1–999 hours) |
| Mounting | Wall-mounted enclosure |
| Enclosure Dimensions | 144 × 144 × 108 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM8202T |
| Product Type | Online |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Temperature Compensation Range | -10 to 130 °C (NTC30K/PT1000) |
| Display | Backlit Graphic LCD |
| Language Support | English & Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS) |
| Communication | RS485 Modbus RTU |
| Cleaning Output | Adjustable interval (0.1–1000 h), duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC) |
| Mounting Options | Wall-mounted, pipe-mounted, panel-mounted |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Prosan 8200 |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.0001 NTU (adjustable) |
| Operating Temperature | 1–50 °C |
| Accuracy | ±2% of reading or ±0.02 NTU (≤40 NTU) |
| Response Time | 5–500 s (adjustable) |
| Light Source | 850 nm LED (7-year lifetime) |
| Display | Backlit multi-line LCD |
| Sample Pressure | 1–200 psi (integrated pressure regulator preset to 15 psi) |
| Output Signals | Isolated 4–20 mA and/or RS-485 with MODBUS RTU protocol |
| Alarm Outputs | Two programmable Hi/Lo relay outputs (250 VAC) |
| Enclosure Rating | IP66 |
| Dimensions | 35 × 30 × 30 cm |
| Weight | 2.5 kg |
| Brand | GreenPrima |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | In-line |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.0001 NTU |
| Operating Temperature | 0–50 °C |
| Accuracy | ±0.02 NTU (for values <40 NTU) or ±2% of reading (for values <40 NTU) |
| Light Source | White LED (7-year lifetime) |
| Output | 4–20 mA isolated analog output and RS-485/Modbus RTU |
| Enclosure Rating | IP66 / NEMA 4X |
| Wetted Materials | 316 Stainless Steel |
| Power Supply | 100–240 VAC, 47–63 Hz, 80 VA |
| Max. Process Pressure | 200 psi (integrated pressure regulator) |
| Response Time | 5–500 s (full range) |
| Display | Backlit multi-line LCD with menu-driven interface |
| Compliance | EPA Method 180.1 and ISO 7027 |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Prosan 8200 |
| Measurement Principle | 90° Nephelometric Scattering |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.0001 NTU (adjustable) |
| Accuracy | ±2% of reading or ±0.02 NTU (≤40 NTU) |
| Response Time | 5–500 s (adjustable) |
| Light Source | 850 nm LED (7-year lifetime) |
| Sample Pressure Range | 1–200 psi (integrated pressure regulator, factory-set to 15 psi) |
| Operating Temperature | 1–50 °C |
| Display | Backlit multi-line LCD |
| Output Signals | Isolated 4–20 mA and/or RS-485 (MODBUS RTU protocol) |
| Alarm Outputs | Two independent Hi/Lo relay outputs (250 VAC) |
| Enclosure Rating | IP66 |
| Dimensions | 35 × 30 × 30 cm |
| Weight | 2.5 kg |
| Installation | Wall-mount |
| Brand | GreenPrima |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Prosan 8200 |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.0001 NTU (adjustable) |
| Operating Temperature | 1–50 °C |
| Accuracy | ±2% of reading or ±0.02 NTU (≤40 NTU) |
| Response Time | 5–500 s (adjustable) |
| Light Source | 850 nm LED (7-year lifetime) |
| Display | Backlit multi-line LCD |
| Sample Pressure | 1–200 psi (integrated pressure regulator, factory-set to 15 psi) |
| Output Signals | Isolated 4–20 mA and/or RS-485 with MODBUS RTU protocol |
| Enclosure Rating | IP66 |
| Dimensions | 35 × 30 × 30 cm |
| Power Supply | 100–240 VAC |
| Weight | 2.5 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Prosan8200 |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.0001 NTU (adjustable) |
| Operating Ambient Temperature | 1–50 °C |
| Accuracy | ±2% of reading or ±0.02 NTU (≤40 NTU) |
| Response Time | 5–500 s (configurable) |
| Light Source | 850 nm LED (7-year lifetime) |
| Display | Backlit LCD, multi-line |
| Sample Pressure Range | 1–200 psi (integrated pressure regulator preset to 15 psi) |
| Output Signals | Isolated 4–20 mA and/or RS-485 (MODBUS RTU protocol) |
| Alarm Outputs | Two programmable Hi/Lo relay outputs (250 VAC) |
| Ingress Protection Rating | IP66 |
| Dimensions | 35 × 30 × 30 cm |
| Weight | 2.5 kg |
| Brand | GreenPrima |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Prosan8200 |
| Product Type | Online |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.0001 NTU (adjustable) |
| Operating Temperature | 1–50 °C |
| Accuracy | ±2% of reading or ±0.02 NTU (≤40 NTU) |
| Response Time | 5–500 s (adjustable) |
| Light Source | 850 nm LED (7-year lifetime) |
| Sample Pressure | 1–200 psi (integrated pressure regulator, factory-set to 15 psi) |
| Display | Backlit LCD, multi-line |
| Output Signals | Isolated 4–20 mA or RS-485 (MODBUS RTU protocol, optional) |
| Ingress Protection | IP66 |
| Dimensions | 35 × 30 × 30 cm |
| Weight | 2.5 kg |
| Power Supply | 100–240 VAC |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Prosan8200 |
| Configuration | Online / Flow-through |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.0001 NTU (user-adjustable) |
| Operating Ambient Temperature | 1–50 °C |
| Accuracy | ±2% of reading or ±0.02 NTU (≤40 NTU) |
| Response Time | 5–500 s (configurable) |
| Light Source | 850 nm LED (7-year rated lifetime) |
| Sample Pressure Range | 1–200 psi (internal pressure regulator preset to 15 psi) |
| Display | Backlit multi-line LCD |
| Output Signals | Isolated 4–20 mA analog output and/or RS-485 with MODBUS RTU protocol |
| Alarm Outputs | Two programmable Hi/Lo relay outputs (250 VAC) |
| Enclosure Rating | IP66 |
| Dimensions | 35 × 30 × 30 cm |
| Weight | 2.5 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Prosan8200 |
| Configuration | Online/In-line |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.0001 NTU (user-adjustable) |
| Operating Temperature | 1–50 °C |
| Accuracy | ±2% of reading or ±0.02 NTU (≤40 NTU) |
| Response Time | 5–500 s (configurable) |
| Light Source | 850 nm LED, rated lifetime ≥7 years |
| Sample Pressure | 1–200 psi (integrated pressure regulator, factory-set to 15 psi) |
| Display | Backlit multi-line LCD |
| Output Signals | Isolated 4–20 mA analog output |
| Alarm Outputs | Two independent Hi/Lo relay outputs (250 VAC) |
| Enclosure Rating | IP66 |
| Dimensions | 35 × 30 × 30 cm |
| Weight | 2.5 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Prosan8200 |
| Product Type | Inline / Online Turbidimeter |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.0001 NTU (adjustable) |
| Operating Temperature | 1–50 °C |
| Accuracy | ±2% of reading or ±0.02 NTU (≤40 NTU) |
| Response Time | 5–500 s (configurable) |
| Light Source | 850 nm LED (7-year lifetime) |
| Sample Pressure | 1–200 psi (integrated pressure regulator, factory-set to 15 psi) |
| Display | Backlit multi-line LCD |
| Output Signals | Isolated 4–20 mA and/or RS-485 (MODBUS RTU protocol) |
| Alarm Outputs | Two programmable Hi/Lo relay outputs (250 VAC) |
| Enclosure Rating | IP66 |
| Dimensions | 35 × 30 × 30 cm |
| Weight | 2.5 kg |