BenAng
Filter
Showing all 4 results
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BA-ZW-A |
| Price | USD 4,750 (FOB Shanghai) |
| Temperature Range | Ambient +20°C to +70°C |
| Temperature Uniformity | ±0.5°C |
| Humidity Range | Up to 95% RH |
| Chamber Dimensions (W×D×H) | 1170 mm × 450 mm × 500 mm |
| UV Lamp Wavelength | 280–315 nm (UV-B) |
| Sample-to-Lamp Distance | 90–100 mm |
| Heating & Humidification | Electric Steam Generator |
| Control System | Imported Digital Touch Panel Controller |
| Compliance | GB/T 5170.9–2017 |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Model | BA-5-13B |
| Instrument Type | Box-Type Muffle Furnace |
| Max Temperature | 1300 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 5000 W |
| Ramp Time to 1000 °C | 12 min |
| Heating Method | Resistance Wire (Kanthal® A1 Alloy) |
| Internal Chamber Dimensions | 400 × 400 × 400 mm |
| Insulation | 50 mm High-Purity Alumina-Silica Ceramic Fiber |
| Thermocouple Type | K-Type (NiCr–NiSi) |
| Control System | PID Digital Controller |
| Voltage | AC 220 V, 50/60 Hz |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.1 ppm |
| Moisture Content Range | 0.00001% (0.1 ppm) to 100% |
| Measurement Accuracy | ±0.1 ppm |
| Minimum Dispensing Volume | 0.5 µL |
| Titration Control Precision | ±0.1 mV |
| Repeatability | ≤0.0002% RSD |
| Linearity Correlation Coefficient | ≥0.9999 |
| Power Consumption | <50 W |
| Operating Voltage | AC 220 V ±10%, 50 Hz |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤85% RH (non-condensing) |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RD-15D |
| Price | USD 1,220 (est.) |
| Purified Water Grade | ASTM Type III / ISO 3696 Grade 3 |
| Resistivity | 13–16 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | < 3 ppb |
| Microbial Count | < 1 CFU/mL |
| Endotoxin | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| RO Recovery Rate | >99% |
| Conductivity | 0.063–0.077 µS/cm |
| Flow Rate | 15 L/h (RO + DI), 1.5 L/min (peak, with pressurized storage tank) |
| Feed Water Requirements | Municipal tap water, TDS < 150 ppm, 1–40 °C, pressure 69–100 kPa (10–14.5 psi) |
| System Configuration | PF + AC + RO + DI + UV (254 nm & 185 nm) + UF |
| Dimensions (H×W×D) | 42 × 41 × 22 cm |
| Weight | 12–20 kg |