| Brand | Bionavis |
|---|---|
| Origin | Finland |
| Model | MP-SPR Navi 200 OTSO |
| Sample Volume | 250 µL |
| Injection Volume | 50 µL |
| Analysis Time | 5–10 min |
| Temperature Control Range | 15–45 °C (ambient ±7 °C / +20 °C) |
| Brand | Bionavis |
|---|---|
| Origin | Finland |
| Model | MP-SPR Navi 210A VASA |
| Sample Volume | 250 µL |
| Injection Volume | 50 µL |
| Analysis Time | 5–10 min |
| Temperature Control Range | 15–45 °C (ambient ±7 °C / +20 °C) |
| Brand | Bionavis |
|---|---|
| Origin | Finland |
| Model | MP-SPR Navi 220A NAALI |
| Sample Volume | 250 µL |
| Injection Volume | 50 µL |
| Analysis Time | 5–10 min |
| Temperature Control Range | 15 °C–45 °C (ambient ±7 °C / +20 °C) |
| Angular Scan Range | 40°–78° |
| Angular Resolution | 0.001° |
| Laser Wavelengths | 670 nm (standard), optional dual-wavelength (670 nm + 785 nm) |
| Refractive Index Range | 1.00–1.40 (bulk), extendable for high-RI materials (e.g., diamond-like carbon, n ≈ 2.7) |
| Flow Rate | 1–1000 µL/min |
| Sensitivity | 1 µRIU (refractive index unit), 1 pg/mm² (protein surface coverage) |
| Kinetic Range | kₐ = 10³–10⁸ M⁻¹s⁻¹, k = 10⁻⁷–0.1 s⁻¹, K_D = 10⁻¹²–10⁻³ M |
| Detection Limit | <100 Da (liquid phase), H₂ (2 Da, gas phase) |
| Noise | Short-term ≤0.3 µRIU, Drift <1 µRIU/min |
| Flow Channels | 2 independent, switchable in series or parallel |
| Sensor Chip Compatibility | Au, Ag, Cu, Pt, SiO₂, Al₂O₃, TiO₂, CMD, Ni²⁺, custom functionalized surfaces |
| Flow Cell Options | PDMS (1 µL/channel), PEEK (SPR305-MS), electrochemical (SPR321-EC), gas-phase (SPR310-GS), fast-kinetics (SPR302-LS), or custom |
| Brand | Bionavis |
|---|---|
| Origin | Finland |
| Model | MP-SPR Navi 400 KONTIO |
| Sample Volume | 250 µL |
| Injection Volume | 50 µL |
| Analysis Time | 5–10 min |
| Temperature Control Range | 15–45 °C |
| Angular Measurement Range | 40–78° |
| Angular Resolution | 0.001° |
| Flow Rate | 10–400 µL/min |
| Laser Wavelengths | 670 nm (standard), optional dual-wavelength (670 nm + 785 nm) |
| Refractive Index Range | 1.00–1.40 (bulk), extendable for high-RI materials (e.g., diamond-like carbon, n ≈ 2.7) |
| Thickness Measurement Range | Å to µm (material-dependent) |
| Kinetic Constants | kₐ = 10³–10⁸ M⁻¹s⁻¹, k = 10⁻⁷–0.1 s⁻¹, K = 10⁻¹²–10⁻³ M |
| Sensitivity | 1 µRIU, 1 pg/mm² (protein coverage) |
| Minimum Detectable Mass | 2 Da (gas phase), <100 Da (liquid phase) |
| Short-term Noise | 0.3 µRIU, Baseline Drift: <1 µRIU/min |
| Flow Channels | 4 (PDMS microfluidic cell) |
| Detection Modes | Angle-scan (full SPR curve) and fixed-angle (kinetic mode, up to 1 ms sampling) |
| Brand | Bionavis |
|---|---|
| Origin | Finland |
| Model | MP-SPR Navi 410A KAURIS |
| Sample Volume | 250 µL |
| Injection Volume | 50 µL |
| Analysis Time | 5–10 min |
| Temperature Control Range | 15–45 °C (ambient ±7 °C / +20 °C) |
| Angular Measurement Range | 40–78° |
| Angular Resolution | 0.001° |
| Flow Rate | 1–1000 µL/min |
| Laser Wavelengths | 670 nm (standard), optional dual-wavelength (670 nm + 785 nm) |
| Refractive Index Range (bulk) | 1.00–1.40 (expandable with multi-wavelength) |
| Thickness Measurement Range | Å to µm (material-dependent) |
| Kinetic Constants | kₐ = 10³–10⁸ M⁻¹s⁻¹, kₑ = 10⁻⁷–0.1 s⁻¹, K<sub>D</sub> = 10⁻³–10⁻¹² M |
| Sensitivity | 1 µRIU |
| minimum detectable mass | <100 Da (liquid phase), 2 Da (gas phase) |
| Short-term Noise | 0.3 µRIU |
| Baseline Drift | <1 µRIU/min |
| Detection Channels | 4 independent flow channels |
| Auto-sampler Capacity | 7 samples |
| Software | MP-SPR Navi™ Control & Data Viewer, TraceDrawer™, LayerSolver™ (optional) |
| Brand | Bionavis |
|---|---|
| Origin | Finland |
| Model | MP-SPR Navi 420A ILVES |
| Sample Volume | 250 µL |
| Injection Volume | 50 µL |
| Analysis Time | 5–10 min |
| Temperature Control Range | 15–45 °C (ambient ±7 °C / +20 °C) |