Brookfield
Filter
Showing 121–148 of 148 results
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | Spiral Adapter |
| Viscosity Range (LV Series) | up to 100,000 cP |
| Viscosity Range (RV Series) | up to 1.1 MPa·s |
| Viscosity Range (HA Series) | up to 2.2 MPa·s |
| Viscosity Range (HB Series) | up to 9.0 MPa·s |
| Repeatability | ±2% |
| Compatibility | All Brookfield standard viscometers and rheometers (DVNext, DV2T, DV3T, CAP2000+, etc.) |
| Shear Sensitivity Analysis | Optional software-supported calculation |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Applicable Instrument Series | LV, RV, HA, HB |
| Shear Rate | 0.677 s⁻¹ per revolution |
| Viscosity Range (LV Series) | up to 100 k cP |
| Viscosity Range (RV Series) | up to 1.1 M cP |
| Viscosity Range (HA Series) | up to 2.2 M cP |
| Viscosity Range (HB Series) | up to 9.0 M cP |
| Unit Equivalence | 1 cP = 1 mPa·s |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | SSA |
| Sample Volume Range | 2–16 mL |
| Geometry | Cylindrical Couette-type |
| Compatible Instruments | All Brookfield DV-series viscometers and rheometers (DV-I+, DV-II+ Pro, DV-III+, DVNext, RST series) |
| Temperature Control | External water bath circulation via jacketed cup (−15 °C to 100 °C) |
| Optional RTD Integration | Yes (direct temperature readout on DV-I+/II+/III+ displays) |
| Disposable Cup Option | Aluminum single-use cup (SC4-13RD-100, pack of 100) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | SSA Small Sample Adapter |
| Sample Volume Range | 2.1–16.1 mL |
| Compatible Spindles | SC4-14, SC4-15, SC4-16, SC4-18, SC4-21, SC4-25Z, SC4-27(D), SC4-28, SC4-29, SC4-31, SC4-34 |
| Shear Rate Range | 0.22–1.32 s⁻¹ (spindle-dependent) |
| Compatible Instruments | DVNext, DV2T, DV3T, DV1, DV2, DV3, LV/ RV/ HA/ HB series digital viscometers and rheometers |
| Compliance | Designed for ASTM D2196, ISO 2555, USP <911>, and GLP-compliant viscosity testing workflows |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | SSA |
| Sample Volume | 2–16 mL |
| Temperature Control Range | –15 °C to 100 °C (with optional RTD probe) |
| Compatible Instruments | All Brookfield DV-series viscometers and RST/ARES rheometers |
| Minimum Measurable Viscosity | ≥1 cP (mPa·s) |
| Shear Rate Range | 0.25–2.2 s⁻¹ (dependent on spindle/chamber combination) |
| Spindle Types | SC4-series (e.g., SC4-14, SC4-15, SC4-21, SC4-27, SC4-28, SC4-29, SC4-31, SC4-34) |
| Sample Chamber Types | SC4-6R(P), SC4-7R(P), SC4-8R(P), SC4-13R(P), SC4-13RPY, SC4-13RD-100 |
| Optional Accessories | Water-jacketed mounting bracket, SC4 spindles, disposable aluminum chambers, RTD-integrated chambers, thermal insulation lid, extension hook assembly |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | TC Series |
| Instrument Type | Constant Temperature Bath |
| Circulation Function | Internal & External Circulation |
| Temperature Control Mode | Heating/Refrigeration Type |
| Bath Volume | 6–10 L |
| Temperature Range | −20 °C to 200 °C |
| Temperature Stability | ±0.01 °C |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Controller Options | AP (touchscreen), SD (LCD scroll), MX (basic LCD) |
| Bath Types | Refrigerated (TC-650/TC-550) and Tap-Water-Cooled (TC-250/TC-150) |
| Reservoir Capacity | 6 L (TC-150), 10 L (TC-250), 7 L (TC-550/TC-650) |
| Temperature Range | −20 °C to +200 °C (refrigerated models) |
| Temperature Stability | ±0.01 °C (AP), ±0.04 °C (SD), ±0.07 °C (MX) |
| Pump Configuration | Variable-speed (AP), dual-speed (SD), single-speed (MX) |
| Max Flow Rate | 12–16 L/min |
| Internal Work Area (D×W×H, in) | 4.5×4.0×6.0 (TC-150) to 6.18×5.59×5.0 (TC-550/TC-650) |
| Compliance | Designed for integration with Brookfield rheometers (DV2T/DV3T/DVNext), cone-plate viscometers (Wells-Brookfield), R/S-CC & R/S-CPS rheometers, SSA, ULA, and DIN adapters |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | TC-150 |
| Temperature Range (MX) | Ambient +10°C to 135°C |
| Temperature Range (SD/AP) | Ambient +10°C to 150°C |
| Temperature Stability (MX) | ±0.07°C |
| Temperature Stability (SD) | ±0.04°C |
| Temperature Stability (AP) | ±0.01°C |
| Controller Options | MX (basic digital), SD (dual-speed pump, PC-controllable via Rheocalc), AP (touchscreen, programmable, multi-language UI, variable-speed pump) |
| Pump Type | Single-speed (MX), Dual-speed (SD), Variable-speed (AP) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | TC-250 |
| Temperature Range | –20 °C to +150 °C (depending on controller variant) |
| Temperature Stability | ±0.01 °C (AP), ±0.04 °C (SD), ±0.07 °C (MX) |
| Controller Options | AP (touchscreen, programmable, multi-language), SD (dual-speed pump, Rheocalc-compatible), MX (basic digital display, single-speed pump) |
| Pump Type | Variable-speed (AP), dual-speed (SD), fixed-speed (MX) |
| Software Integration | Compatible with Brookfield Rheocalc v3.0+ for remote programming and data logging |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | TC-550 |
| Temperature Range (MX) | –20 °C to +135 °C |
| Temperature Range (AP) | –20 °C to +200 °C |
| Temperature Range (SD) | –20 °C to +170 °C |
| Temperature Stability (MX) | ±0.07 °C |
| Temperature Stability (AP) | ±0.01 °C |
| Temperature Stability (SD) | ±0.04 °C |
| Control Interface | MX — large-character LCD |
| Pump Configuration | MX — single-speed pump |
| External Circulation | Yes |
| Max Internal Bath Volume Capacity | 600 mL (standard beaker compatibility) |
| Software Integration | Compatible with RheocalcT v3.0+ for remote parameter setting, real-time monitoring, and GLP-compliant data logging |
| Brand | Brookfield |
|---|---|
| Origin | Germany |
| Model | TC-650 |
| Temperature Range (TC-650AP) | –20 °C to +200 °C |
| Temperature Range (TC-650SD) | –20 °C to +170 °C |
| Temperature Range (TC-650MX) | –20 °C to +135 °C |
| Temperature Stability | ±0.01 °C (AP), ±0.04 °C (SD), ±0.07 °C (MX) |
| Bath Capacity | 7.0 L |
| Pump Flow Rate | 16 L/min (AP), 11 L/min (SD), 12 L/min (MX) |
| Pump Type | Adjustable-speed (AP), 2-stage (SD), 1-stage (MX) |
| Internal Dimensions (W×D×H) | 157 × 142 × 127 mm |
| External Dimensions (W×D×H) | 540 × 220 × 617 mm (AP/SD), 540 × 220 × 645 mm (MX) |
| Weight | 45 kg (AP/SD), 42 kg (MX) |
| Power Supply | Voltage and frequency specified at order |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | TC-650 |
| Temperature Range | –20 °C to +200 °C (depending on controller variant) |
| Temperature Stability | ±0.01 °C (AP), ±0.04 °C (SD), ±0.07 °C (MX) |
| Bath Capacity | 7 L |
| Max Vessel Size | 600 mL beaker compatible |
| Control Type | Microprocessor-based SD, AP, or MX digital controller |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Certifications | CE, UL-listed components |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | Thermosel |
| Temperature Range | Up to 300°C |
| Controller Type | Programmable (1–10 setpoints) |
| Compatible Instruments | DV2T, DV3T, and select Brookfield digital viscometers/rheometers |
| Required Accessories | DVP-141 cable (for basic operation) |
| Included Components | SC4-series spindle (user-specified), alignment stand, insulated heating furnace with safety guard and thermal cap, 1 reusable sample cup, 5 disposable sample cups (HT-2DB-100 optional), 18" instrument stand, sampling tool, RTD temperature probe |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | Thermosel |
| Temperature Range | Up to 300 °C |
| Control Mode | Programmable (1–10 setpoints) |
| Compatibility | DV Series, DVNext, and Rheometers with analog/RS-232 interface |
| Sample Volume | 7–13 mL (depending on spindle & cup configuration) |
| Output Signal | 0–4 VDC (chart recorder), RS-232 (digital communication) |
| Spindle Support | SC4 series (e.g., SC4-18, SC4-27, SC4-29), HT-DIN-81, and other Brookfield geometry spindles |
| Shear Rate Range | 0.25–116.8 s⁻¹ (dependent on spindle, speed, and geometry) |
| Reusable Vessel | Stainless steel sample holder included |
| Disposable Cups | Aluminum single-use cups (e.g., SC4-27D-100 pack available) |
| Optional Accessories | SC4-DSY adapter, HT-106 cable (for RheocalcT QC), DVP-141 cable (for DVNext integration) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | THERMOSEL |
| Pricing | Available Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Instrument |
| Model | TT-100 |
| Price Range | USD 14,000 – 70,000 |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ULA |
| Pricing | Available Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ULA |
| Pricing | Available Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | ULA |
| Viscosity Range (with compatible viscometers) | 1.0–2,000 cP (mPa·s) |
| Compatible Instruments | LVT, DV-I/II/III/Next series (LV, RV, HA, HB spindles) |
| Sample Volume | 16 mL |
| Geometry | Cylindrical cup-and-rotor system |
| Material | Stainless steel (cup, rotor, mounting hardware) |
| Optional Disposable Component | Low-density polyethylene (LDPE) bottom cap |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Type | Newtonian Calibration Fluids |
| Variants | General-Purpose Silicone Oil Standards, High-Temperature Silicone Oil Standards, Hydrocarbon (Mineral Oil / Polybutene) Standards, CAP-Series Spindle-Specific Standards, KU-2 Krebs Units Standards, RST/RheoStress Coaxial & Cone Standards |
| Viscosity Range | 5–360,000 cP (mPa·s) at 25.0°C |
| Accuracy | ±1% of nominal viscosity |
| Temperature Stability | ≤±0.5% per °C (silicone oils) |
| Certified Traceability | NIST-traceable calibration documentation available upon request |
| Packaging | 600 mL glass or 1000 mL HDPE bottles |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | VTE |
| Instrument Type | In-line Viscometer |
| Viscosity Range | 10–10,000 cP |
| Output Signal | 4–20 mA (linear) |
| Accuracy | ±1% of full scale |
| Control Relay | 3 A solenoid-type |
| Enclosure Rating | NEMA 1 |
| Operating Environment | Ambient temperature |
| Compliance | Designed for continuous industrial process monitoring |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Online Viscometer |
| Model | VTE-250 |
| Viscosity Range | 1–10,000 cP |
| Measurement Principle | Rotational (Coaxial Cylinder, Couette Flow) |
| Display | Digital LCD with Keypad Interface |
| Repeatability | ±0.2% of Full Scale |
| Accuracy | ±1% of Full Scale |
| Output Signal | 4–20 mA (2-wire loop powered) |
| Control Output | Relay-rated up to 3 A, electromagnetic valve compatible |
| Power Supply | 115/230 VAC, 50/60 Hz, 100 W |
| Enclosure Rating | NEMA 1 |
| Max Flow Rate | 1 GPM (3.79 L/min) |
| Operating Pressure | Ambient (atmospheric) |
| Sample Chamber Material | Optional polymer (e.g., PTFE-lined or FDA-compliant thermoplastic) |
| Mounting | In-line or side-stream bypass configuration with universal bracket and quick-connect fittings |
| Cleaning | Tool-free chamber removal for CIP-compatible maintenance |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | WA-5A |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | 0.001 ng (1 pg) |
| Quantification Range | 0.001–1000 ng |
| Sample Matrix Compatibility | Ambient Air, Natural Gas, Shale Gas, LPG, LNG |
| Compliance Standards | ASTM D5954-98(2014)e1, ISO 6978-2:2005, ISO 20552, JLPGA-S-07 |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | WA-5F |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Fluorescence Spectrometry (CVAFS) |
| Detection Limit | 0.1 pg |
| Quantification Range | 0.001–1000 ng |
| Sample Matrix Compatibility | Ambient Air, Natural Gas, Shale Gas, LPG, LNG |
| Compliant Methods | UOP 1033-19, ASTM D6350-14, ISO 6978-2:2005, JLPGA-S-07, ISO 20552, USEPA IO-5 |
| Brand | Brookfield |
|---|---|
| Origin | Shanghai, China |
| Model | YXQ-LS-50A |
| Instrument Type | Vertical Steam Sterilizer |
| Maximum Temperature | 135 °C |
| Maximum Pressure | 0.25 MPa |
| Chamber Dimensions | Ø300 mm × 680 mm |
| External Dimensions | 525 mm × 440 mm × 1080 mm |
| Chamber Volume | 50 L |
| Power Rating | 2.7 kW |
| Voltage/Frequency | 220 V ±10%, 50 Hz ±2% |
| Operating Pressure Range | 0–0.22 MPa (working), 0–0.25 MPa (design) |
| Temperature Control Range | Ambient to 135 °C |
| Timer Range | 0–120 min |
| Exhaust Mode | Internal recirculating steam exhaust with 3 L gas collection bottle |
| Safety Features | Dual pressure interlock, self-sealing gasket, automatic cold air purge, low/high water level alarm, dry-run protection, overtemperature cutoff, pressure relief valve |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 631-X |
| Instrument Type | Portable |
| Target Gas | Hydrogen Sulfide (H₂S) |
| Response Time | 3–20 seconds |
| Measurement Accuracy | ±0.003 ppm |
| Measurement Range | 0.003 ppm to 50 ppm |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 651 |
| Instrument Type | Online Gas Monitor |
| Target Gas | Hydrogen Sulfide (H₂S) |
| Response Time | ≤60 s |
| Measurement Accuracy | ±0.005 ppm |
| Measurement Range | 3 ppb (0.003 ppm) to 50 ppm |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | J605 |
| Instrument Type | Portable Gas Analyzer |
| Target Gas | Hydrogen Sulfide (H₂S) |
| Response Time | 12–27 s (Survey Mode) |
| Measurement Accuracy | ±1 ppb at 5 ppb, ±3 ppb at 50 ppb, ±0.03 ppm at 0.5 ppm, ±0.3 ppm at 5.0 ppm |
| Measurement Range | 3 ppb (0.003 ppm) to 10 ppm |
| Resolution | 20 ppt (0.02 ppb) |
| Gas Flow Rate | 150 mL/min |
| Data Storage Capacity | 20,000 samples with timestamp and up to 80 location tags |
| Battery Life | 18 h (rechargeable NiMH), 3 h charge time |
| Operating Temperature | 0–40 °C, non-condensing, non-explosive environment |
| Certifications | TÜV 61010, CE, ISO 9001:2015 |
