Cubic
Filter
Showing 61–90 of 113 results
| Brand | Cubic |
|---|---|
| Model | JM-AM4302 |
| Detection Principle | Electrochemical |
| Gas Measured | CO |
| Range | 0–1000 ppm |
| Resolution | 1 ppm |
| Alarm Threshold | 220 ppm (adjustable) |
| Alarm Accuracy | ±40 ppm |
| Response Time | <60 s (diffusion mode) |
| Operating Temp. | −10°C to +50°C |
| Humidity Range | 0–90% RH |
| Power Supply | 3 VDC |
| Current Consumption | ≤1 mA |
| IP Rating | IP30 (per GB 23757) |
| Compliance | GB 15322.2–2019, UL 2034–2017, RoHS, China Fire Certification |
| Sensor Lifetime | 10 years |
| Dimensions | 84 × 84 × 33.5 mm |
| Weight | 260 g |
| Output Interface | UART serial (default) |
| Indication | Green (normal), Red (alarm), Yellow (fault or end-of-life) |
| Brand | Cubic |
|---|---|
| Model | JT-AM5301 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Target Gas | CH₄ |
| Range | 0–100% LEL |
| Accuracy | ±3% LEL |
| Alarm Threshold | 10% LEL |
| Response Time | <30 s (diffusion) |
| Operating Temp. | −10°C to +50°C |
| Humidity | 0–90% RH |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 3 W |
| IP Rating | IP30 (per GB 23757) |
| Compliance | GB 15322.2–2019, CCC Fire Certification (3CF) |
| Communication | NB-IoT (default), optional Wi-Fi or 4G |
| Sensor Lifetime | ≥10 years |
| Dimensions | 84 × 84 × 33.5 mm |
| Weight | 240 g |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MS-VOC |
| Pricing | Available Upon Request |
| Target Gases | Formaldehyde, Benzene, CO, H₂, Ethanol, NH₃, Cigarette Smoke |
| Preheat Time | 180 s |
| Operating Temperature | −10 °C to 50 °C |
| Storage Temperature | −20 °C to 60 °C |
| Response Time | ≤30 s |
| Rated Voltage | DC 5 V ±0.2 V |
| Output Interface | UART (5 V logic) or 0–3 V analog |
| Dimensions | 24 mm × 20 mm × 5 mm |
| Power Design | Constant-power operation |
| Calibration | Factory-calibrated |
| Stability | Long-term baseline stability |
| Power Consumption | Low-power operation |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MS-VOC-V4 |
| Pricing | Upon Request |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NOx/O₂ Dual-Gas Sensor |
| Voltage Range | 16–36 V DC |
| O₂ Measurement Range | 0–21% vol |
| NOx Measurement Range | 0–1500 ppm (NO + NO₂, λ > 1, NH₃-free environment) |
| NOx Accuracy | ±10 ppm (for [NOx] < 100 ppm) |
| Response Time (T₃₃–₆₆%) | NOx: 1200 ms (new generation), 1300 ms (legacy) |
| O₂ | 1000 ms (new), 1100 ms (legacy) |
| Fast Transient Response (T₁₀–₉₀%) | NOx: 100 ms |
| O₂ | 80 ms |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturing Type | OEM Sensor Component |
| Product Type | NOx Sensing Chip (HTCC-Based Electrochemical Platform) |
| Model | NOx Sensor Chip |
| Operating Principle | Potentiometric/Electrochemical Current Measurement |
| Measurement Range | 0–3076 ppm NOx |
| Operating Temperature | −40 °C to 1000 °C (exhaust-side) |
| Ambient Temperature Rating | −40 °C to 105 °C |
| Supply Voltage | 12 V / 24 V DC |
| CAN Interface | ISO 11898-2 compliant, 250 kbps baud rate |
| CAN Message Interval | 50 ms |
| Heater Power Consumption | Low-power integrated HTCC heater |
| Structural Design | Compact, high-vibration-resistant dual protective cap |
| Lifetime | Extended operational lifespan under cyclic thermal stress |
| Compliance | Designed for alignment with Euro VI, China VI, and EPA Tier 4 emission regulation monitoring requirements |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | OPC-6303DS |
| Instrument Type | Online |
| Flow Rate | 2.83 L/min |
| Detection Principle | Light Scattering |
| Particle Size Channels | 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm |
| Counting Efficiency | 50% @ 0.3 μm, 100% @ ≥0.5 μm (25±2°C, 50±10% RH) |
| Accuracy Compliance | JJF 1190 |
| Power Supply | DC 12–24 V |
| Operating Temp. | 0–45°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Display | 3.5-inch color LCD |
| Communication Interfaces | RS485 (standard), RJ45 Ethernet (standard), 4–20 mA output (standard), MQTT/TCP/IP support |
| Data Update Interval | 1 s |
| Warm-up Time | ≤8 s |
| IP Rating | IP44 |
| Lifetime | ≥3 years |
| Optional | Visual/audible alarm module (LED strobe + 110 dB siren) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | OPC-6303M |
| Instrument Type | Online |
| Detection Principle | Optical Scattering |
| Particle Size Range | 0.3–10 μm |
| Counting Efficiency | 50% at 0.3 μm, 100% ≥0.5 μm (per TSI 9306 reference, 25±2°C, 50±10% RH) |
| Warm-up Time | ≤8 s |
| Data Update Interval | 1 s |
| Operating Temperature | 0–45°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Temp/Humidity | −20–60°C / 0–95% RH (non-condensing) |
| Power Supply | DC 12 V |
| Avg. Current Draw | ≤1 A |
| Flow Rates | 2.83 L/min (Class 10,000 cleanroom), 28.3 L/min (Class 1,000 cleanroom) |
| Output Channels | 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm (pcs/L) |
| Compliance | JJF 1190 |
| Standard Interface | RS485 |
| Optional Interfaces | RJ45 Ethernet, 4–20 mA analog output |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | OPC-6510 |
| Flow Rate | 28.3 L/min |
| Flow Accuracy | Compliant with JJF-1190 |
| Timing Accuracy | Compliant with JJF-1190 |
| Size Distribution Accuracy | Compliant with JJF-1190 |
| Indication Error | Compliant with JJF-1190 |
| Detection Principle | Light Scattering |
| Channel Count | 6 (0.3, 0.5, 1.0, 2.5, 5.0, 10.0 µm) |
| Counting Efficiency | 50% at 0.3 µm |
| Measurement Range | 0–1,000,000 particles per 28.3 L |
| Warm-up Time | ≤8 s |
| Data Update Interval | 1 s |
| Operating Temp. | 0–45°C |
| Operating RH | 0–95% non-condensing |
| Storage Temp./RH | −20–60°C / 0–95% non-condensing |
| Power Supply | DC 24 V |
| Avg. Current Draw | ≤3 A |
| Communication | RS485 (standard), RJ45 (optional) |
| Service Life | ≥3 years |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | OPC-6510DS |
| Instrument Type | Online Particle Counter |
| Flow Rate | 28.3 L/min |
| Channel Sizes | 0.3 µm, 0.5 µm, 1.0 µm, 5.0 µm, 10.0 µm |
| Counting Efficiency | 50% at 0.3 µm |
| Measurement Range | 0–1,000,000 pcs/28.3 L |
| Accuracy Compliance | JJF 1190–2008 |
| Display | 3.5-inch color TFT screen |
| Power Supply | DC 24.0 V ±15%, ≤3 A avg. |
| Communication Interfaces | RS485 (standard), RJ45 Ethernet (standard) |
| Protocol Support | TCP/IP, MQTT |
| Unit Options | pcs/28.3 L or pcs/m³ |
| Operating Temp. | 0–45°C |
| RH | 0–95% non-condensing |
| Storage | −20–60°C, 0–95% RH non-condensing |
| Warm-up Time | ≤8 s |
| Data Update Interval | 1 s |
| Sampling Probe | Isokinetic probe with Ø10 mm internal diameter tubing (≤3 m length) |
| Duty Cycle | Configurable (default: 2 min active / 28 min sleep) |
| Lifetime | ≥3 years |
| Calibration Standard | JJF 1190–2008 |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | OPC-6511DS |
| Instrument Type | Handheld |
| Flow Rate | 28.3 L/min |
| Counting Channels | 0.3 µm, 0.5 µm, 1.0 µm, 5.0 µm, 10.0 µm |
| Counting Efficiency | 50% @ 0.3 µm, 100% @ ≥0.5 µm (25±2°C, 50±10% RH) |
| Measurement Range | 0–1,000,000 pcs/28.3 L |
| Display | 7-inch color TFT LCD |
| Power Supply | DC 24.0 V ±15% |
| Battery Standby Duration | >5 h (2 min active / 28 min sleep cycle) |
| Communication Interfaces | RS485 (standard), RJ45 Ethernet (standard) |
| Compliance | JJF 1190–2008 |
| Warm-up Time | ≤8 s |
| Data Refresh Interval | 1 s |
| Operating Temperature | 0–45°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −20–60°C, 0–95% RH (non-condensing) |
| Sampling Probe | Isokinetic, external tube ID φ10 mm, max length 3 m |
| Lifetime | ≥3 years |
| Unit Options | pcs/28.3 L or pcs/m³ (switchable) |
| Protocol Support | TCP/IP, MQTT |
| Calibration Support | Standard source coefficient correction |
| Language Interface | English / Chinese toggle |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | OPM-6303M |
| Measurement Principle | Optical Light Scattering |
| Safety Rating | Non-Explosion-Proof |
| Measurement Range | 0–30 mg/m³ |
| PM₁.₀/PM₂.₅ Accuracy | ±10 µg/m³ (≤100 µg/m³), ±10% of reading (100–1000 µg/m³) |
| PM₁₀ Accuracy | ±15 µg/m³ (≤100 µg/m³), ±15% of reading (100–1000 µg/m³) |
| TSP Accuracy | ±20 µg/m³ (≤100 µg/m³), ±20% of reading (100–1000 µg/m³) |
| Warm-up Time | ≤8 s |
| Data Update Interval | 1 s |
| Operating Temperature | −30 to +70 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Storage Temperature | −40 to +85 °C |
| Power Supply | DC 12 V |
| Average Current Draw | ≤4.5 A |
| Communication Interface | RS485 |
| Sampling Flow Rate | 1 L/min (standard, customizable) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Oxygen Sensor Chip |
| Measurement Range | 0.98–1.02 (λ unit) |
| Operating Temperature | −40 °C to 1000 °C |
| Ambient Temperature Range | −40 °C to 105 °C |
| Supply Voltage | 12 V DC |
| Startup Time | ≤15 s to operational temperature (vs. >30 s for conventional thimble-type) |
| Heater Power Consumption | <12 W (typical at cold start) |
| Sensor Architecture | Multilayer ceramic planar element with integrated micro-heater and dual protective guard tubes |
| Aging Resistance | <±0.005 λ drift after 100,000 km simulated exhaust exposure (ISO 22738-compliant test cycle) |
| Poisoning Resistance | Validated against Pb, Si, P, and oil ash contaminants per SAE J1679 |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | PM1006 |
| Detection Principle | Optical Scattering (Infrared LED + Photodiode) |
| Measurement Range | 0–1000 µg/m³ |
| Accuracy | ±20 µg/m³ or ±20% of reading (at 25°C ±2°C, 50% ±10% RH, calibrated against TSI AM510/8530 reference) |
| Warm-up Time | ≤8 s |
| Operating Temperature | −20°C to +75°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Temperature | −40°C to +85°C |
| Supply Voltage | DC 5.0 V ±0.2 V (ripple <50 mV) |
| Operating Current | ≤30 mA |
| Output Interfaces | UART TTL (logic level 4.5 V), PWM (4.5 V) |
| Dimensions | 46.2 × 34.1 × 18 mm (W×H×D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | PM1007 |
| Detection Principle | Optical Light Scattering (Nephelometry) |
| Measurement Range | 0–5 mg/m³ |
| Accuracy | ±30 µg/m³ or ±30% of reading (at 25±2 °C, 50%±10% RH) |
| Warm-up Time | 8 s |
| Operating Temperature | −20 °C to +75 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −40 °C to +85 °C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 5 V ±0.2 V (ripple <100 mV) |
| Operating Current | ≤30 mA |
| Output Interfaces | UART (4.5 V logic level), PWM (4.5 V logic level) |
| Dimensions | 66.8 × 38.8 × 21.6 mm (W×H×D) |
| Expected Service Life | ≥5 years |
| Electromagnetic Shielding | Integrated |
| Particle Size Sensitivity | 0.3–10 µm |
| Application Domain | Commercial Kitchen Exhaust Monitoring, Fume Hood Compliance Verification, Local Emission Control Systems |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PM1009 |
| Pricing | Available Upon Request |
| Detection Principle | Optical Transmission (Opposed-Beam) |
| Warm-up Time | 1 s |
| Operating Temperature | −10 °C to +60 °C |
| Operating Humidity | ≤95% RH (non-condensing) |
| Storage Temperature | −20 °C to +80 °C |
| Supply Voltage | DC 5.0 V ± 0.25 V (Ripple < 50 mV) |
| Operating Current | < 60 mA |
| Output Signal | PWM (3.3 V logic level) |
| Response Time | < 200 ms |
| Dimensions (PCBA only) | 43 mm × 25 mm × 5 mm (W × H × D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PM2008 |
| Pricing | Available Upon Request |
| Detection Principle | Laser Light Scattering |
| PM2.5 Measurement Range | 0–1000 µg/m³ |
| Accuracy | ±10 µg/m³ or ±10% of reading (at 25°C ±2°C, 50% RH ±10%, calibrated against TSI AM510/8530 reference instrument) |
| Operating Temperature | −10°C to +50°C |
| Storage Temperature | −20°C to +60°C |
| Housing Material | Full Metal Enclosure (EMI-Shielded) |
| Dimensions (PM2008) | 47.8 mm (W) × 36.8 mm (H) × 11.7 mm (D) |
| Airflow Configuration | Co-planar inlet/outlet on wide face (PM2008/PM2008M) |
| Output Interfaces | UART, PWM, I²C |
| Thickness | ≤12.1 mm |
| Particle Recognition | Intelligent Source Discrimination Algorithm (Cubic Proprietary) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | PM2008MSE |
| Detection Principle | Optical Scattering (Laser Nephelometry) |
| Measurement Range | 0–1000 µg/m³ (PM1.0, PM2.5, PM10) |
| Resolution | 0.3 µm |
| Accuracy (PM2.5) | ±10 µg/m³ (≤100 µg/m³), ±10% of reading (>100 µg/m³) |
| Accuracy (PM10) | ±20 µg/m³ (≤100 µg/m³), ±20% of reading (>100 µg/m³) |
| Data Update Interval | 1 s |
| Warm-up Time | ≤8 s |
| Operating Temperature | −10 to +50 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −20 to +60 °C, 0–95% RH |
| Supply Voltage | DC 5 V ±0.1 V (ripple <50 mV) |
| Operating Current | ≤100 mA |
| Standby Current | ≤200 µA |
| Interface | UART (3.3 V logic), I²C (3.3 V logic) |
| Dimensions | 48 × 40 × 12 mm (W × H × D) |
| Shielding | Full-metal EMI enclosure |
| Design | Ultra-thin profile (12 mm height) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PM2009 |
| Pricing | Available Upon Request |
| Detection Principle | Laser Light Scattering |
| PM2.5 Range | 0–1000 μg/m³ (extendable to PM1.0 and PM10) |
| Warm-up Time | ≤8 s |
| Data Update Interval | 1 s |
| Accuracy | ±10 μg/m³ or ±10% of reading (at 25°C±2°C, 50%±10% RH |
| Operating Temperature | −10°C to +60°C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Storage Conditions | −30°C to +70°C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 5.0 V ±0.1 V (ripple <100 mV) |
| Operating Current | ≤100 mA |
| Standby Current | <25 mA |
| Output Interfaces | UART TTL (3.3 V / 5 V logic), I²C (reserved), PWM (reserved) |
| Dimensions | 50 × 38 × 21 mm (W × H × D) |
| Enclosure | Metal-shielded housing |
| Structural Feature | Integrated self-cleaning mechanism with co-located inlet/outlet airflow path |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PM2012 |
| Pricing | Upon Request |
| Detection Principle | Laser Light Scattering |
| PM2.5 Range | 0–1000 µg/m³ (extendable to PM1.0 & PM10) |
| Warm-up Time | ≤8 s |
| Data Update Interval | 1 s |
| Accuracy | ±10 µg/m³ or ±10% of reading (at 25°C±2°C, 50%±10% RH |
| Operating Temp. | −10°C to +60°C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Storage Temp. | −30°C to +70°C |
| Storage Humidity | 0–95% RH (non-condensing) |
| Supply Voltage | DC 5 V ±0.5 V (ripple <50 mV) |
| Operating Current | ≤100 mA |
| Standby Current | ≤200 µA |
| Output Interfaces | UART TTL (3.3 V / 5 V logic), I²C (3.3 V) |
| Dimensions | 38 mm × 35 mm × 12 mm (W×H×D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PM2105 |
| Pricing | Available Upon Request |
| Detection Principle | Laser Light Scattering |
| PM2.5 Range | 0–1000 µg/m³ |
| Warm-up Time | ≤8 s |
| Data Update Interval | 1 s |
| Accuracy | ±15 µg/m³ or ±15% of reading (at 25°C ±2°C, 50% RH ±10%, referenced to TSI AM510/8530) |
| Operating Temperature | −10°C to +50°C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Storage Conditions | −30°C to +60°C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 5.0 V ±0.1 V (ripple <50 mV) |
| Operating Current | ≤100 mA |
| Standby Current | <20 mA |
| Output Interfaces | UART TTL (3.3 V), I²C (3.3 V / 5 V compatible), PWM (reserved) |
| Dimensions | 42 × 35 × 23.7 mm (W × H × D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PM2107 |
| Pricing | Available Upon Request |
| Operating Principle | Laser Light Scattering |
| Measurement Range | 0–1000 µg/m³ |
| Accuracy | ±15 µg/m³ or ±15% of reading |
| Detection Principle | Laser Scattering |
| PM2.5 Range | 0–1000 µg/m³ |
| Power-On Stabilization Time | ≤8 s |
| Data Update Interval | 1 s |
| Environmental Conditions (Calibration) | 25°C ±2°C, 50% RH ±10%, referenced to TSI AM510/8530 |
| Operating Temperature | −10°C to +50°C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Storage Temperature | −30°C to +60°C |
| Storage Humidity | 0–95% RH (non-condensing) |
| Supply Voltage | DC 5.0 V ±0.1 V, ripple <50 mV |
| Operating Current | ≤100 mA |
| Standby Current | <20 mA |
| Output Interfaces | UART TTL (3.3 V logic), PWM (default 5 V, 3.3 V configurable) |
| Dimensions | 58.7 mm (W) × 45 mm (H) × 13.9 mm (D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PM3003Q |
| Price | USD 630 (FOB) |
| Operating Principle | Laser Light Scattering |
| Safety Rating | Non-Explosive Atmosphere Rated |
| Measurement Range | 0–50 mg/m³ (max display: 1000 mg/m³) |
| Accuracy | ±200 µg/m³ for 0–1 mg/m³ |
| Detection Principle | Optical Scattering |
| Recommended Sample Flow Rate | 2 L/min |
| Data Update Interval | 1 s |
| Operating Temperature | 30–70 °C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Storage Temperature | −40–85 °C |
| Storage Humidity | 0–95% RH (non-condensing) |
| Supply Voltage | DC 5 V ± 0.2 V (ripple < 100 mV) |
| Average Current Consumption | <150 mA |
| Standby Current | <25 mA |
| Interface | UART (TTL 3.3 V logic level) |
| Dimensions | 90.8 × 60.2 × 37.6 mm (W × H × D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | PM3003S |
| Measurement Principle | Laser Light Scattering (90° Detection Geometry) |
| Safety Rating | Explosion-Proof (Ex ib IIB T4 Gb) |
| Measurement Range | 0–1000 µg/m³ |
| Accuracy | PM1.0: ±10 µg/m³ or ±10% of reading |
| PM2.5 | ±10 µg/m³ or ±10% of reading |
| PM10 | ±15 µg/m³ or ±15% of reading |
| TSP | ±20 µg/m³ or ±20% of reading |
| Sampling Flow Rate | 1.0 L/min (pump-assisted) |
| Data Refresh Interval | 1 s |
| Operating Temperature | −30 °C to +70 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Power Supply | DC 5.0 V ±0.1 V (ripple <50 mV) |
| Current Consumption | <150 mA (operational), <25 mA (standby) |
| Output Interfaces | Analog voltage (0–5 V or 0–10 V configurable), UART TTL (3.3 V logic level) |
| Dimensions | 82 × 40.2 × 26.3 mm (W × H × D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | PM3003SN |
| Detection Principle | Laser Light Scattering |
| Particle Size Channels | 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 µm |
| Counting Range | 0–10,000,000 pcs/L (equivalent to 0–283,000,000 pcs/ft³) |
| Counting Efficiency | 50% at 0.3 µm |
| Warm-up Time | ≤8 s |
| Data Update Interval | 1 s |
| Operating Temperature | −30°C to +70°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Temperature | −40°C to +85°C |
| Supply Voltage | DC 5.0 V ±0.1 V (ripple <50 mV) |
| Operating Current | <150 mA |
| Standby Current | <25 mA |
| Communication Interfaces | UART-TTL (3.3 V / 5 V), I²C (3.3 V / 5 V), RS-485 |
| Dimensions | 82 × 40.2 × 26.3 mm (W × H × D) |
| Compliance | JJF 1190–2008 (Calibration Specification for Airborne Particle Counters) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | PM3003SN |
| Detection Principle | Laser Light Scattering |
| Measurement Range | 0–10,000,000 pcs/L (1 pcs/L = 28.3 pcs/ft³) |
| Output Channels | 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10 µm |
| Counting Efficiency | 50% @ 0.3 µm |
| Warm-up Time | ≤8 s |
| Data Refresh Rate | 1 s |
| Operating Temperature | −30°C to +70°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Temperature | −40°C to +85°C |
| Supply Voltage | DC 5.0 V ±0.1 V (ripple <50 mV) |
| Operating Current | <150 mA |
| Standby Current | <25 mA |
| Signal Outputs | Analog raw signal |
| Dimensions | 82 × 40.2 × 26.3 mm (W×H×D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | PM3006S |
| Measurement Principle | Laser Light Scattering |
| Safety Rating | Non-Explosive |
| Measurement Range | 0–1000 µg/m³ (detection limit: 30 mg/m³) |
| Resolution | 1 µg/m³ |
| Accuracy | ±10 µg/m³ or ±10% (PM1.0/PM2.5), ±15 µg/m³ or ±15% (PM10), ±20 µg/m³ or ±20% (TSP) |
| Operating Temperature | −40 °C to +70 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Power Supply | DC 5.0 V ±0.1 V, ripple <50 mV |
| Current Consumption | ≤250 mA (operational), <20 mA (standby) |
| Output Interfaces | UART TTL (3.3 V / 5 V), I²C (3.3 V / 5 V) |
| Dimensions | 85 × 74 × 24.9 mm (W × H × D) |
| Warm-up Time | ≤8 s |
| Data Refresh Rate | 1 s |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | PM3009BP |
| Detection Principle | Optical Scattering with Intelligent Particle Recognition Algorithm |
| Mounting Type | Online Fixed Installation |
| Measurement Range | 0–5000 µg/m³ (extended capability up to 50,000 µg/m³) |
| Accuracy | ±15 µg/m³ at ≤100 µg/m³ |
| Sample Flow Requirement | Compatible with external pump (3–9 L/min) |
| Operating Temperature | −20°C to +60°C |
| Storage Temperature | −30°C to +70°C |
| Power Supply | DC 5 V ±0.1 V |
| Max Current Draw | ≤1 A |
| Communication Interfaces | UART, I²C |
| Dimensions | 80.3 mm (W) × 80 mm (H) × 28.3 mm (D) |
| Key Features | Sidestream Sampling Architecture, Integrated Water Mist Removal, Lens Auto-Cleaning Mechanism, Real-Time Particulate Concentration Output, Source-Aware Particle Discrimination |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PM5000S |
| Operating Principle | Light Scattering (Laser Nephelometry) |
| Safety Rating | Non-Explosive Atmosphere Rated |
| Measurement Channels | 0.3, 0.5, 1.0, 2.5, 5.0, and 10.0 µm |
| Calibration Compliance | JJF 1190–2008 “Calibration Specification for Airborne Particle Counters” |
| Output Format | Particle concentration in pcs/L per channel |
| Sampling Flow Rate | 2.83 L/min (standard) |
| Detection Efficiency | ≥50% at 0.3 µm |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PM5100 |
| Instrument Type | Online |
| Flow Range | High-Flow (28.3 L/min) |
| Flow Accuracy | Compliant with JJF 1190 |
| Timing Accuracy | Compliant with JJF 1190 |
| Counting Repeatability | ≤5% |
| Size Distribution Accuracy | Compliant with JJF 1190 |
| Indication Error | Compliant with JJF 1190 |
| Detection Principle | Optical Light Scattering |
| Detectable Particle Sizes | 0.3, 0.5, 1.0, 5.0, and 10.0 µm |
| Counting Efficiency | 50% at 0.3 µm |
| Maximum Allowable Concentration | 1,000,000 pcs/28.3 L @ 0.3 µm |
| Self-Cleaning Time | ≤5 min |
| Data Update Interval | 1 s |
| Operating Temperature | 0–40°C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Storage Conditions | −10–50°C, 5–95% RH (non-condensing) |
| Power Supply | DC 5 V ±0.2 V, Ripple <100 mV |
| Average Current Draw | <250 mA |
| Communication Interface | UART-TTL (3.3 V logic level) |
| Dimensions | 99.2 × 66 × 41.7 mm (W × H × D) |