| Measurement Range | 0.0–4.0 mg/m³ |
|---|---|
| Accuracy | ±10% |
| Sampling Cycle | < 1 min |
| Operating Voltage | 220 VAC |
| Power Consumption | 8 W |
| Operating Temperature | –25°C to +75°C |
| Operating Humidity | 5%–95% RH |
| Probe Dimensions | φ45 × 10 mm |
| Data Logger Dimensions | φ45 × 270 mm |
| Startup Time | ~20 s (network-dependent) |
| Controlled Load Rating | 2 kW / 250 V / 10 A per channel |
| Overcurrent Protection | Auto-disconnect after 6 s at threshold exceedance |
| Communication Interfaces | RS485 (sensor), Analog Inputs (status), TCP/IP, CDMA/GPRS/2G, WiFi, LoRa, NB-IoT |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | BCNX-YY08 |
| Price Range | USD 0.14–714 (FOB) |
| Detection Principle | Multi-Parameter Integrated Sensing (Optical Scattering + Semiconductor/PID for NMHC + Dedicated Oil Mist Transduction) |
| Mobility | Fixed Online Installation |
| Application Domain | Commercial Food Service Establishments (Restaurants, Canteens, Street Food Hubs) |
| Oil Mist Measurement Range | 0–30,000 µg/m³ |
| Accuracy | ±10% of reading (vs. reference gravimetric method) |
| Zero Drift | ≤±0.5 mg/m³ over 1 h |
| Relative Error vs. Reference Method | ≤±20% (per HJ 629–2011 & DB11/1488–2018) |
| Linearity Error | ≤10% |
| Insulation Resistance | ≥20 MΩ |
| Withstand Voltage | No arcing or dielectric breakdown at rated test voltage |
| Sampling Cycle | 60 s |
| Operating Voltage | 220 VAC ±10% |
| Power Consumption | 8 W |
| Operating Temperature | 0–70 °C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Probe Dimensions | Ø24 × 248 mm (installation bore: Ø25–26 mm) |
| PM Measurement | Optical scattering principle |
| Resolution | 1 µg/m³ |
| Range | 0–20 mg/m³ (configurable variants: 0–10 mg/m³ or 0–2000 mg/m³) |
| NMHC Measurement | Dual-mode selectable — Metal Oxide Semiconductor (MOS) or Photoionization Detector (PID) |
| Range | 0–30 ppm or 0–1000 ppm |
| Resolution | 0.1 ppm (PID), 1 ppm (MOS) |
| Control Outputs | 4-channel dry-contact relay interface for fan/purifier status monitoring and remote switching |
| Overcurrent Protection | Automatic cut-off after 6 s if load current exceeds threshold |
| Data Reporting Interval | User-configurable (1–3600 s) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | BCNX-YY08 |
| Price Range | USD 0.14–714 (FOB) |
| Detection Principle | Multi-Parameter Integrated Sensing (Optical Scattering + Semiconductor/PID for NMHC + Dedicated Oil Mist Transduction) |
| Mobility | Fixed Online Installation |
| Application Domain | Commercial Food Service Establishments (Restaurants, Canteens, Street Food Hubs) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | Custom Model 11 |
| Pricing | Upon Request |
| Measurement Principle | Infrared Light Scattering |
| Range | 0–5 mg/L |
| Resolution | 0.01 mg/L |
| Adjustable Alarm Threshold | 0.9–2.5 mg/L |
| Communication Interface | RS485 |
| Power Supply | 24 VDC |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | PM1007 |
| Detection Principle | Optical Light Scattering (Nephelometry) |
| Measurement Range | 0–5 mg/m³ |
| Accuracy | ±30 µg/m³ or ±30% of reading (at 25±2 °C, 50%±10% RH) |
| Warm-up Time | 8 s |
| Operating Temperature | −20 °C to +75 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −40 °C to +85 °C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 5 V ±0.2 V (ripple <100 mV) |
| Operating Current | ≤30 mA |
| Output Interfaces | UART (4.5 V logic level), PWM (4.5 V logic level) |
| Dimensions | 66.8 × 38.8 × 21.6 mm (W×H×D) |
| Expected Service Life | ≥5 years |
| Electromagnetic Shielding | Integrated |
| Particle Size Sensitivity | 0.3–10 µm |
| Application Domain | Commercial Kitchen Exhaust Monitoring, Fume Hood Compliance Verification, Local Emission Control Systems |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | PM3009BP |
| Detection Principle | Optical Scattering with Intelligent Particle Recognition Algorithm |
| Mounting Type | Online Fixed Installation |
| Measurement Range | 0–5000 µg/m³ (extended capability up to 50,000 µg/m³) |
| Accuracy | ±15 µg/m³ at ≤100 µg/m³ |
| Sample Flow Requirement | Compatible with external pump (3–9 L/min) |
| Operating Temperature | −20°C to +60°C |
| Storage Temperature | −30°C to +70°C |
| Power Supply | DC 5 V ±0.1 V |
| Max Current Draw | ≤1 A |
| Communication Interfaces | UART, I²C |
| Dimensions | 80.3 mm (W) × 80 mm (H) × 28.3 mm (D) |
| Key Features | Sidestream Sampling Architecture, Integrated Water Mist Removal, Lens Auto-Cleaning Mechanism, Real-Time Particulate Concentration Output, Source-Aware Particle Discrimination |
| Brand | Eranntex |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MIC-500S-C3H₈ |
| Detection Principle | Electrochemical (configurable for Catalytic Combustion, NDIR, PID, Thermal Conductivity per gas type) |
| Mounting Type | Fixed Online Installation |
| Output | 4–20 mA (3-/4-wire), RS485 Modbus RTU, Relay Outputs (2× SPDT), Optional Wireless (GPRS/WiFi/433 MHz), Ethernet, or Cloud Integration |
| Certifications | Exd IIC T6 Gb (CNEx17.3959), GB15322.1–2019, GB3836.1–2010, GB3836.2–2010, CPA Type Approval |
| IP Rating | IP65 |
| Operating Temperature | −40 °C to +70 °C |
| Humidity Range | 10–95% RH (non-condensing) |
| Display | 1.7″ color LCD (optional remote display via MIC2000 controller) |
| Power Supply | 12–36 VDC (24 VDC nominal, ≥1 A) |
| Dimensions (L×H×W) | 238×210×90 mm (with beacon) / 238×152×90 mm (without beacon) |
| Weight | 1.8 kg |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHK-2500 |
| Portability | Portable |
| Detection Principle | Electrochemical & Light Scattering Hybrid Sensing (Compliant with HJ 2526–2012) |
| Application Scope | Universal for Food Service Emission Monitoring |
| Standards Compliance | HJ 2526–2012, GB 18483–2001, DB11/1488, SZDB/Z 254–2017, GB/T 16157–1996 |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHK-2500B |
| Price Range | USD 7,000 – 21,000 (FOB) |
| Detection Principle | Laser Light Scattering (Compliant with DB13/T 5530–2022) |
| Portability | Handheld, Field-Deployable |
| Application Scope | Commercial Kitchen Emission Monitoring, Environmental Compliance Auditing, Municipal Enforcement, Research & Education |
| Brand | Spectra Invent |
|---|---|
| Origin | Zhejiang, China |
| Model | OIL-560 |
| Portability | Portable |
| Detection Principle | Infrared Spectrophotometry (Triple-Wavelength Absorption at 2930 cm⁻¹, 2960 cm⁻¹, 3030 cm⁻¹) |
| Sample Processing Capacity | 12-position automated extraction |
| Interface | 10-inch Windows-based touch display |
| Compliance | Designed for EPA Method 202 / HJ 637-2018 / ISO 12103-1 (adapted) |
| Application Scope | Stationary source emission monitoring, kitchen exhaust, metalworking fluid mist, food processing fumes |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | OL1050 |
| Detection Principle | Infrared Absorption (FTIR-compatible broadband IR photometry) |
| Instrument Class | Laboratory-Based Fixed-Position Analyzer |
| Primary Application Sector | Petrochemical Industry |
| Compliance Basis | Designed to support EPA Method 27 / ISO 12103-1 alignment for airborne oil aerosol quantification |
| Measurement Range | Configurable via auto-dilution (standard range: 0.1–100 mg/m³, extendable to 500 mg/m³ with intelligent over-range dilution) |
| Sample Introduction | Filter Cartridge (glass fiber or quartz) or Sleeve-Type Sampling Probe |
| Extraction Solvent | Tetrachloroethylene (C₂Cl₄) |
| Extraction Method | High-Efficiency Ultrasonic Assisted Extraction |
| Phase Separation | Automatic Density-Based Liquid-Liquid Separation (C₂Cl₄/H₂O) |
| Calibration Modes | Certified Reference Material (CRM)-based calibration, Multi-Point Standard Curve, Single-Point Rapid Calibration |
| Reagent Handling | Fully Automated Dispensing, Recovery, and Activated Carbon–Filtered Exhaust Management |
| Data Interface | Embedded Touchscreen PC + Remote Web API & Mobile App (iOS/Android) |
| Software Compliance | Audit-trail enabled, 21 CFR Part 11–ready data logging (user authentication, electronic signature, change history) |
| Brand | Online Instrument |
|---|---|
| Model | OL1056 |
| Origin | Shanghai, China |
| Portability | Portable |
| Application Field | Food Service Industry (Commercial Kitchen Exhaust Monitoring) |
| Compliance Basis | HJ 646–2013, HJ 647–2013, HJ 1077–2019 (Chinese EPA Standards for Oil Fume Emission Monitoring) |
| Sample Handling | Fully Automated Reagent Dispensing, Dual-Stage Ultrasonic Extraction, Cuvette Cleaning, Volumetric Finalization, Photometric Quantification at 530 nm |
| Data Output | Excel, PDF, LIMS-Compatible Export |
| Remote Operation | Web-Based Dashboard & Mobile App Support |
| Enclosure Material | Reinforced Engineering Thermoplastic (IP54 Rated) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YWT-2024 |
| Pricing | Upon Request |
| Detection Principle | Light Scattering (Multi-Path Compensated) |
| Portability | Portable |
| Application Scope | Marine Engineering, Hydraulic Systems, Engine Rooms, and Industrial Enclosures |
| Target Aerosol Size Range | 1–10 µm |
| Measurement Range | 0–5 mg/L |
| Resolution | 0.01 mg/L |
| Output Interface | RS485 |
| Power Supply | 24 VDC |
| Ingress Protection Rating | IP56 |
| Operating Temperature | 0–70 °C |
| Compliance | IACS Unified Requirement UR67 (Oil Mist Detection in Main Engine Crankcases) |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TH-502 |
| Price Range | USD 3,500 – 5,600 |
| Measurement Principle | Split-stream opacimetric (non-transmissivity) optical method |
| Operating Temperature | 80 ± 1 °C (measurement chamber) |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Data Interface | Bluetooth 4.0 (host-to-mobile), optional GPRS module |
| Output Units | Opacity (%) and Light Absorption Coefficient (k, m⁻¹) |
| Compliance Standards | GB 3847–2018, GB 36886–2018, HJ/T 395–2007 |
| Calibration | Auto-zero and auto-span via single-button initiation |
| Sample Interface | Direct exhaust coupling via probe and flexible sampling line |
| Display & Storage | Real-time visualization and logging via Android/iOS app |
| Printing | Bluetooth thermal printer support |
| Environmental Protection | Dual air curtain optical protection system |
| Warm-up Time | ≤5 min to operational temperature |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-7000 |
| Compliance | GB 18483–2001, Q/WTH 30–2017 |
| Measurement Principle | Laser Light Scattering (for oil fume particulate mass concentration), Electrochemical Sensing (for Non-Methane Hydrocarbons, NMHC) |
| Display | 7-inch Color TFT Touchscreen (Chinese UI) |
| Data Storage | Up to 45,000 records |
| Communication Interfaces | RS232, RS485, Ethernet, GPRS/DTU |
| Environmental Operating Range | 0–40 °C with Internal Thermostatic Control |
| Explosion-Proof Enclosure | IP65-rated Industrial Housing |
| Flow Measurement | Integrated S-type Pitot Tube (factory-calibrated in proprietary wind tunnel) |
| Sensor Lifetime | >2 years (typical field service life under routine maintenance) |
| Power Input | AC 220 V ±10%, 50 Hz |
| Dimensions | 420 × 320 × 180 mm |
| Weight | ~8.5 kg |