Dynamica
Filter
Showing all 14 results
| Brand | Dynamica |
|---|---|
| Origin | Australia |
| Model | DB20R |
| Optical Design | Dual-beam |
| Detector Type | Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.0 nm |
| Stray Light | ≤0.05% (at 220 nm with NaI, 340 nm with NaNO₂) |
| Wavelength Accuracy | ±0.3 nm |
| Absorbance Range | –3.0 to +3.0 A |
| Transmittance Range | 0–300% T |
| Concentration Range | 0.000–9.999 units |
| Scan Speeds | 10–3600 nm/min (8 selectable rates) |
| Baseline Stability | 0.0003 A/hr (500 nm, 2 h) |
| Noise Level | 0.0003 A (500 nm, RMS) |
| Light Sources | Deuterium Lamp + Tungsten-Halogen Lamp |
| Automatic Lamp Switching | 325–370 nm |
| Interface | PC-controlled (no built-in display) |
| Dimensions (W×D×H) | 505 × 705 × 225 mm |
| Net Weight | 29 kg |
| Power Supply | 110–220 V AC, 50/60 Hz |
| Brand | Dynamica |
|---|---|
| Origin | Australia |
| Model | DNAmaster |
| Optical Design | Single-beam |
| Light Source | Long-life xenon lamp |
| Detector | CCD array |
| Wavelength Range | 200–900 nm |
| Absorbance Range | 0–4.0 OD |
| Wavelength Accuracy | ±1 nm |
| Slit Width | 4 nm |
| Noise | ~0.005 OD (RMS) |
| Drift | ~0.005 OD |
| Photometric Accuracy | ±0.01 OD |
| Photometric Repeatability | ±0.005 OD |
| Stray Light | 0.5% T |
| Minimum Sample Volume | 0.5 µL |
| DNA Detection Limit | 20 ng/µL |
| Data Storage | Internal memory or SD card |
| Power Supply | 110–240 V, 50/60 Hz |
| Energy-saving Mode | Yes |
| Startup Audio Selection | 7 options |
| Brand | Dynamica |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DynaCell190i |
| Price Range | USD 7,800–10,000 (FOB) |
| Instrument Type | Air-jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | Ambient +5°C to 50°C, ±0.1°C (at setpoint) |
| Temperature Uniformity | ±0.3°C at 37°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol., ±0.1% (full scale) |
| Humidity Control Range & Accuracy | 20–95% RH, ±3% RH (measured at 37°C, 5% CO₂) |
| Chamber Capacity | 190 L |
| External Dimensions (W×D×H) | 720 × 694.5 × 890 mm |
| Standard Configuration | Dual-stage HEPA filtration (0.3 µm, ≥99.97% efficiency), Dual sterilization protocol (180°C dry-heat bake-out, 90°C moist-heat cycle) |
| Brand | Dynamica |
|---|---|
| Model | EHS-530 |
| Cabinet Class | Class II, Type A2 |
| Construction Material | 304 Stainless Steel Interior (One-Piece Seamless Welded) |
| External Dimensions (L×W×H) | 1950 × 750 × 2100 mm |
| Internal Work Area Dimensions (L×W×H) | 1862 × 574 × 628 mm |
| HEPA/ULPA Filtration Efficiency | ≥99.9995% @ 0.12 µm |
| Airflow System | Recirculating (70% re-circulated, 30% exhausted via dedicated duct or thimble connection) |
| Motor Type | Brushless DC ECM Motor with Variable Speed Control |
| Control Interface | DynaAir Color Touchscreen Controller with Real-Time Airflow Monitoring |
| Sensor | High-Sensitivity Thermal Anemometer for Inflow & Downflow Velocity Detection |
| Compliance | EN 12469:2000, NSF/ANSI 49-2022, ISO 14644-1 Class 5 (ISO Class 5 Equivalent), GLP-Ready Configuration |
| Brand | Dynamica |
|---|---|
| Origin | Australia |
| Model | DB-30 |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1–5.0 nm (6 selectable slits) |
| Stray Light | ≤0.01%T (220 nm NaI, 340 nm NaNO₂) |
| Wavelength Accuracy | ±0.3 nm |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs, NIST 900D) |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs, NIST 930D) |
| Baseline Flatness | ±0.001 Abs (200–850 nm) |
| Baseline Stability | 0.0004 Abs/hr (500 nm, after 2 hr) |
| Noise Level | ±0.0003 Abs (500 nm) |
| Scan Speeds | 1–2,000 nm/min (8 selectable rates) |
| Light Sources | Tungsten-halogen & Deuterium lamps with automatic switching (325–370 nm) |
| Detector | Photomultiplier tube (PMT) |
| Control OS | Windows XP or Windows 7 Pro |
| Dimensions | 710 × 630 × 268 mm (W×D×H) |
| Net Weight | 50 kg |
| Power | 110–220 V AC, 50/60 Hz, 300 VA |
| Brand | Dynamica |
|---|---|
| Model | HALO MPR-96 |
| Origin | Switzerland |
| Wavelength Range | 400–750 nm (MPR-96UV: 340–750 nm) |
| Absorbance Range | 0–4.0 OD |
| Resolution | 0.001 OD |
| Stability | ±0.001 OD (after 15 min warm-up) |
| Accuracy | ±1.0% ±0.01 OD (405 nm, 0.000–2.500 OD) |
| Repeatability | ±0.5% ±0.005 OD (405 nm, 0.000–2.500 OD) |
| Linearity | ±1.0% (405 nm, 0.000–2.500 OD) |
| Filter Positions | 5 (4 fixed + 1 user-selectable, 400–750 nm) |
| Read Time | ≤10 s (single wavelength, 96-well) |
| Plate Formats | 96-well flat, U-bottom, V-bottom |
| Optical Channels | 8 measurement + 1 reference |
| Detector | Silicon photodiode |
| Light Source | Tungsten-halogen lamp |
| Display | Backlit LCD, 320×240 px |
| Incubation (optional) | Ambient +4°C to +50°C, ±0.5°C accuracy |
| Dimensions (W×D×H) | 290×425×200 mm |
| Weight | 15 kg (net), 20 kg (gross) |
| Power | 110–220 V auto-switching, 50/60 Hz, 50 W (standby), 100 W (operational) |
| Brand | Dynamica |
|---|---|
| Model | NU-437-400S / NU-437-600S |
| Type | Class II A2 Biological Safety Cabinet |
| External Dimensions (W×D×H) | 1972 × 835 × 1600 mm (NU-437-600S) / 1362 × 835 × 1600 mm (NU-437-400S) |
| Internal Work Area (W×D×H) | 1788 × 597 × 724 mm (NU-437-600S) / 1178 × 597 × 724 mm (NU-437-400S) |
| Inflow Velocity | 0.53 m/s |
| Downflow Velocity | 0.30 m/s |
| HEPA Filtration Efficiency | ≥99.999% for particles 0.1–0.3 µm (H14 grade) |
| Airflow Configuration | 30% exhaust, 70% recirculation |
| Construction | 16-gauge 304 stainless steel, fully welded double-wall chamber |
| Pressure Integrity | Withstands 500 Pa static pressure test |
| Compliance | YY 0569–2011 (China), aligned with NSF/ANSI 49 and EN 12469 principles |
| Brand | Dynamica |
|---|---|
| Origin | Germany |
| Model | V30R |
| Instrument Type | Benchtop High-Speed Refrigerated Centrifuge |
| Speed Range | 200–30,000 rpm (10 rpm increments) |
| Max RCF | 66,410 × g |
| Max Capacity | 6 × 250 mL |
| Temperature Range | −20 °C to +40 °C (1 °C increment) |
| Temperature Accuracy | ±1 °C |
| Acceleration/Deceleration Steps | 10/10 |
| Noise Level | <60 dB(A) |
| Dimensions (L×D×H) | 715 × 510 × 420 mm |
| Net Weight | 91 kg |
| Power Supply | 230 V, 50/60 Hz |
| Drive System | Brushless Induction Motor |
| Control System | Microprocessor-Based |
| Rotor Auto-Recognition | Yes (with overspeed protection) |
| Imbalance Detection | Yes |
| Timer Range | 30 s – 99 h 59 min + HOLD |
| Speed/RCF Conversion | Yes |
| Programmable Methods | 99 |
| Display | LCD |
| Brand | Dynamica |
|---|---|
| Model | VELOCITY 14/14R Pro |
| Type | Refrigerated Benchtop Centrifuge |
| Max Speed | 14,000 rpm |
| Max RCF | 21,780 × g |
| Max Capacity | 6 × 50 mL |
| Temperature Range | –20 °C to +40 °C |
| Acceleration/Deceleration | 9-step programmable |
| Unbalance Detection | Non-contact electronic |
| Rotor Recognition | Automatic |
| Drive | Brushless Induction Motor |
| Noise Level | <58 dB(A) (14R), <53 dB(A) (V14) |
| Dimensions (W×D×H) | 560 × 500 × 380 mm (14R), 340 × 490 × 380 mm (V14) |
| Net Weight | 60 kg (14R), 40 kg (V14) |
| Power Supply | AC 220 V, 50/60 Hz, 10 A (14R), 8 A (V14) |
| Brand | Dynamica |
|---|---|
| Origin | Shanghai, China |
| Model | Velocity 17/17R Pro |
| Type | Benchtop Refrigerated Centrifuge |
| Speed Range | Up to 17,000 rpm |
| Max RCF | 25,507 × g |
| Max Capacity | 6 × 50 mL |
| Temperature Range | –20 °C to +40 °C |
| Dimensions (W × D × H) | 560 × 500 × 380 mm |
| Rotor Compatibility | 16 interchangeable rotors (angle, fixed-angle, swing-out) |
| Safety Certifications | IEC 61010-1, EN 61326-1 |
| Compliance | GLP-ready, supports audit trails and user access control |
| Brand | Dynamica |
|---|---|
| Origin | Shanghai, China |
| Model | VELOCITY 18R |
| Instrument Type | Benchtop Centrifuge |
| Function | Refrigerated Centrifugation |
| Configuration | Horizontal Rotor System |
| Max. Capacity | 4 × 300 mL |
| Max. Speed | 18,000 rpm |
| Max. RCF | 30,318 × g |
| Dimensions (L×W×H) | 730 × 610 × 380 mm |
| Net Weight | 100 kg |
| Power Supply | AC 220 V, 50/60 Hz, 10 A |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±2 °C |
| Noise Level | <58 dB(A) |
| Acceleration | 9 levels |
| Deceleration | 10 levels |
| Rotor Recognition | Automatic, non-contact |
| Imbalance Detection | Non-contact electronic sensing |
| Speed Range | 300–18,000 rpm (100 rpm increments) |
| Speed Accuracy | ±20 rpm |
| Timer | 1 min – 99 h 59 min + Hold function |
| Memory | 9 programmable protocols |
| Drive | Brushless induction motor |
| Display | Backlit LCD panel |
| Pre-cool Function | Yes |
| Sample Temperature Monitoring | Real-time rotor-based temperature measurement |
| Brand | Dynamica |
|---|---|
| Model | Velocity 18R Plus |
| Type | Benchtop Refrigerated Centrifuge |
| Max Speed | 18,000 rpm |
| Max RCF | 30,318 × g |
| Max Capacity | 4 × 400 mL |
| Temperature Range | –20 °C to +40 °C |
| Dimensions (W×D×H) | 670 × 625 × 380 mm |
| Drive System | Brushless DC Motor |
| Rotor Recognition | Automatic RFID-based |
| Acceleration/Deceleration Profiles | 10 selectable rates |
| Timer Modes | Fixed time, ramp-to-speed, hold-at-speed |
| Compliance | ISO 13485 design principles, GLP-ready audit trail logging, FDA 21 CFR Part 11–compatible software options available |
| Brand | Dynamica |
|---|---|
| Origin | Shanghai, China |
| Model | Velocity15/15R Pro |
| Type | Benchtop Refrigerated Centrifuge |
| Max Speed | 15,000 rpm |
| Max RCF | 22,302 × g |
| Max Capacity | 50 mL (e.g., 10 × 5 mL conical tubes) |
| Temperature Range | −20 °C to +40 °C |
| Speed Increment | 100 rpm |
| Acceleration/Deceleration | 2-step selectable |
| Timer Range | 1–99 min |
| Noise Level | <53 dB(A) |
| Rotor Auto-ID | Yes |
| Rotor Compatibility | Fixed-angle rotors for 0.2 mL PCR tubes (32×), 2 mL microtubes (24×), 5 mL conical tubes (10×), and cryovials |
| Speed/RCF Conversion | Built-in |
| Display | Real-time progress bar, error code diagnostics |
| Control | Single-knob intuitive interface |
| Instant Spin Function | Yes |
| Brand | Dynamica |
|---|---|
| Origin | Australia |
| Model | XB-10 VIS-20 |
| Wavelength Range | 190–1000 nm (XB-10), 330–1000 nm (VIS-20) |
| Spectral Bandwidth | 5 nm (XB-10), 8 nm (VIS-20) |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | 1 nm |
| Photometric Accuracy | ±1% T |
| Photometric Repeatability | 0.50% T |
| Stray Light | <0.5% at 220 nm, 340 nm, and 360 nm |
| Noise | 0.004 A at 250 nm, 0 A |
| Absorbance Range | –0.3 to 1.999 A |
| Transmittance Range | 0–199.9% T |
| Concentration Range | –300 to 1999 (user-selectable resolution: 1, 0.1, 0.01, or 0.001) |
| Data Storage | SD card |
| Measurement Modes | Absorbance, Transmittance, Concentration, Multi-wavelength, Kinetic (Time Scan), Spectrum Scan |
| Peak Detection | Automatic peak/valley identification in spectral scans |