Edinburgh Instruments
Filter
Showing all 18 results
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrumentation |
| Model | Boxed Gascard |
| Operating Voltage Range | 7–30 V DC |
| Communication Interface | RS232 (optional) |
| Onboard Pressure Compensation Range | 800–1150 mbar |
| Infrared Source | Field-replaceable |
| Temperature Compensation | Wide-range, integrated |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model Series | FIR-295, FIR-395, FIRL100 |
| Core Technology | CO₂-laser-pumped molecular gas laser |
| Wavelength Range | 40 µm – 1.22 mm (0.25–7.5 THz) |
| Output Power | ≥150 mW (PL5-pumped), ≥500 mW (PL6-pumped) at selected lines (e.g., 118.8 µm, 184.3 µm) |
| Construction | Invar-stabilized resonator frame, hollow metallic waveguide, dichroic output coupler |
| Cooling | Integrated water-cooling system |
| Vacuum Level | High-vacuum operation (<10⁻⁵ mbar) |
| Compliance | Designed for laboratory-based THz research under ISO/IEC 17025-aligned environments |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | FLS1000 |
| Dispersion Element | Grating Monochromator |
| Instrument Type | Steady-State and Time-Resolved Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 0–30 nm |
| Optical Resolution | 0.05 nm |
| Sensitivity | 35,000:1 (RMS method) |
| Wavelength Accuracy | ±0.2 nm |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Model | FLS1000 |
| Spectral Range | 185 nm – 5500 nm |
| Lifetime Range | 10 ps – 10 s |
| Sensitivity (RMS) | >35,000:1 |
| Monochromator Focal Length | 325 mm |
| Grating Configuration | Interchangeable triple-grating turret (single- or dual-monochromator options) |
| Software | FluOracle® v4.x (supports ASTM E275, ISO 11698, USP <1031>, GLP-compliant audit trail & 21 CFR Part 11 optional modules) |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | FS5 v2 |
| Dispersion Element | Grating |
| Instrument Type | Steady-State and Time-Resolved Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 0–30 nm |
| Optical Resolution | 0.01 nm |
| Sensitivity | 4000:1 (Signal-to-Noise Ratio) |
| Wavelength Accuracy | ±0.5 nm |
| Excitation Sources | Xenon Arc Lamp, Pulsed Laser Diodes (e.g., 375 nm, 405 nm, 445 nm, 485 nm, 635 nm), Optional OPO/UV Laser Systems |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Gascard NG |
| Operating Range | 0–5000 ppm to 0–100% (gas-dependent) |
| Pressure Compensation | 800–1150 mbar |
| Supply Voltage | 7–30 V DC |
| Communication Interface | RS232 |
| Light Source | Field-replaceable infrared source |
| Display Support | 4-bit and 128 × 64 pixel graphical LCD via expansion port |
| Target Gases | CO, CO₂, CH₄, N₂O (customizable) |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Guardian NG |
| Price Range | USD 3,800 – 5,100 (FOB UK) |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Guardian Plus |
| Detection Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Measurable Gases | CO₂ (0–3000 ppm to 0–100% vol), CH₄ (0–5% to 0–100% vol) |
| Output Options | 4–20 mA, RS-232/RS-485, Modbus RTU/TCP |
| Enclosure Rating | IP65 |
| Operating Temperature | –10 °C to +50 °C |
| Power Supply | 24 VDC ±10% |
| Compliance | CE, UKCA, RoHS, EMC Directive 2014/30/EU |
| Calibration | Factory-calibrated with optional user-accessible zero/span adjustment |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | IR5 |
| Instrument Type | Benchtop Laboratory FTIR Spectrometer |
| Wavenumber Range | 350–8000 cm⁻¹ |
| Spectral Resolution | 0.01 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 20,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector) |
| Wavenumber Accuracy | ±0.5 cm⁻¹ |
| Detector Options | Standard DTGS |
| Software Platform | Miracle™ v5.x |
| Optional Module | FT-PL (Fourier Transform Photoluminescence) with Integrated Laser Excitation Source |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LifeSpec II |
| Wavelength Dispersion Element | Dual Grating Monochromator |
| Spectral Bandpass (Slit) | 0–60 nm |
| Optical Resolution | 0.01 nm |
| Sensitivity (Signal-to-Noise Ratio) | 6000:1 |
| Wavelength Accuracy | ±0.1 nm |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LP980 |
| Pricing | Available Upon Request |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Mini-Tau |
| Spectral Dispersion | Interference Filter-Based |
| Instrument Type | Steady-State and Time-Resolved Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 0–60 nm |
| Spectral Resolution | 50 nm |
| Signal-to-Noise Ratio | 3000:1 |
| Wavelength Accuracy | ±5 nm |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MTL-3 |
| Configuration | Sealed-off Gas Laser System |
| Pulse Width | Nanosecond-scale |
| Wavelength Range | 9.2–10.8 µm (60 discrete lines) |
| Repetition Rate | 1–100 Hz (standard), up to 2000 Hz (custom high-rep-rate variants) |
| Output Energy | Up to 150 mJ (multi-mode), TEM₀₀ option available |
| Max Custom Energy | 3.5 J (large-aperture TEA configuration) |
| Tuning Mechanism | Intracavity grating |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Gas Laser System |
| Model | MTL-5 |
| Output Wavelength Range (Tunable) | 9.2–10.8 µm |
| Fixed Wavelength Output | 10.6 µm (multimode) |
| Tunable Single-Line Output | >60 spectral lines |
| Pulse Width (typ.) | 50 ns |
| Repetition Rate | Up to 100 Hz |
| Max. Pulse Energy (fixed, multimode) | 150 mJ |
| Max. Pulse Energy (tunable, single-line) | 50 mJ |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Model | PL2 / PL3 / PL5 / PL6 |
| Laser Type | Gas Laser (CO₂ / CO) |
| Wavelength Range | CO₂: 9.1–10.9 µm |
| CO | 5.2–6.0 µm |
| Output Power (Flowing) | up to 180 W (PL6), 1 W (PL3) |
| Output Power (Sealed) | up to 30 W (PL2/PL3), 10 W (PL5) |
| Spectral Lines | 60–90 lines |
| Beam Quality (M²) | 1.25–1.5 |
| Beam Diameter | 4.8–11 mm |
| Divergence | 2.6–6.5 mrad |
| Polarization | Vertical or Horizontal |
| Power Stability | ±1% to ±2% (rms, 8-hr) |
| Frequency Stability | 200–500 kHz/sec (free-running) |
| Tuning Mechanism | Diffraction Grating + Piezoelectric Cavity Length Control |
| Linewidth (SLM) | <100 kHz (typ., with active stabilization) |
| Pulse Option (PL5) | Q-switched, 150 ns, 1 kHz, 2 kW peak power |
| Construction | Invar-based rigid frame for thermal & mechanical stability |
| Operating Mode | Continuous-wave (CW) and Q-switched (PL5 only) |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model Range | PL2-S, PL2-M, PL3, PL5, PL6 |
| Output Wavelength Ranges | 5.2–6.0 µm (CO mode), 9.1–10.9 µm (CO₂ mode) |
| Output Power | Up to 180 W CW (PL6), up to 2 kW peak (PL5 Q-switched) |
| Tuning Mechanism | Precision diffraction grating + piezoelectric cavity length control |
| Beam Polarization | Linear, fixed orientation |
| Spectral Linewidth | < 100 MHz (typical, free-running) |
| Pulse Operation | Available on PL5 (200 ns pulse width, 1 kHz repetition rate) |
| Number of Accessible Rotational-Vibrational Lines | > 80 (PL5), > 90 (PL6), with > 60 lines ≥ 120 W (PL6) |
| Mechanical Construction | Invar-based rigid monolithic frame |
| Compliance | CE-marked, RoHS-compliant, designed for ISO/IEC 17025-aligned laboratory environments |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | RM5 |
| Instrument Type | Confocal Raman Microspectrometer |
| Spectral Range | 50–15000 cm⁻¹ |
| Spectral Resolution | ≥1 cm⁻¹ (FWHM) |
| Spatial Resolution | Down to 1 µm |
| Low-Wavenumber Cutoff | <50 cm⁻¹ |
| Spectral Reproducibility | ≤0.02 cm⁻¹ |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | RMS1000 |
| Spectral Range | 50–30000 cm⁻¹ |
| Spectral Resolution | ≤0.1 cm⁻¹ (FWHM) at ≥800 mm focal length |
| Spatial Resolution | XY ≤ 0.5 µm, Z ≤ 1 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.02 cm⁻¹ |