| Brand | Flash Spectrum (Shanghai Flash Spectrum Biotech Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-2000Prime |
| Flow Rate Range | 0.01–50 mL/min |
| Pressure Range | 0–1 MPa (145 psi) |
| UV Wavelength Range | 190–850 nm |
| Path Length | 2 mm |
| Conductivity Range | 1 µS/cm – 999.9 mS/cm |
| pH Range | 0–14 |
| pH Accuracy | ±0.01 pH unit with temperature compensation |
| Fraction Capacity | 120 tubes (15–18 mm diameter) |
| Solvent Compatibility | Aqueous biological buffers up to 10 cP viscosity |
| Gradient Formation | Programmable dual-pump high-precision mixing |
| Detection Modes | UV absorbance, conductivity, pH (optional), real-time peak tracking |
| Brand | Flash Spectrum (Shanghai Flash Spectrum Biotech Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-3000Pro |
| Pump Flow Range | 0.01–50 mL/min (optional 0.01–100 mL/min) |
| Max Pressure | 27 MPa (270 bar) at ≤25 mL/min |
| UV Detection Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Optical Path Lengths | 2 mm (standard), 5 mm & 10 mm (optional) |
| Conductivity Range | 0–999.9 mS/cm |
| Conductivity Detector | High-precision, dual-electrode design |
| pH Detector (optional) | Temperature-compensated, accuracy优于进口同类产品 |
| Gradient Formation | Precision high-pressure binary gradient mixing |
| Detection Channels | Quad-wavelength simultaneous detection |
| Column Compatibility | Single-column configuration (1-position), optional 6-port column switching valve (5 columns + bypass) |
| Fraction Collector | X-Y matrix format, 96-position rack support (18 × 150 mm tubes or 15 mL conical tubes), programmable peak-, volume-, or manual-triggered collection |
| System Fluidics | Bio-inert PEEK and titanium components, pressure-rated to 27 MPa |
| Software | ClearFirst-3000 Series Workstation (Windows-based, GLP-compliant audit trail, user management, method library, instrument self-diagnosis) |
| Brand | Flash Spectrum (Shanghai Flash Spectrum Biotech Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SuPerMax 3000AL |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Spectral Scan |
| Curve Fitting | Linear regression |
| Detection Technologies | UV-Vis Absorbance, Chemiluminescence |
| Wavelength Range | 190–1000 nm (monochromator-based) |
| Absorbance Range | 0–4 OD (96-well, 450 nm) |
| Absorbance Linearity | 0–4 OD (±2% at 450 nm, 96-well) |
| Wavelength Scanning Speed | 6 sec per wavelength (kinetic mode) |
| Chemiluminescence Sensitivity | <7 amol ATP/well (flash-type ATP assay), dynamic range >7 decades |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | <0.2 nm |
| Temperature Control | Ambient +2°C to 65°C |
| Plate Types | 96-well and 384-well microplates |
| Detection Detectors | Photodiode (absorbance), Photon-counting PMT (chemiluminescence) |
| Light Source | Xenon flash lamp |
| Plate Agitation | Linear, orbital, and circular shaking (adjustable amplitude) |
| Data Interface | USB 2.0 |
| Optional Modules | Dual-channel liquid dispenser (10–1000 µL), audit trail module, incubation shaker (MF-10) |