| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | ARIA |
| Instrument Type | Automated |
| Reservoir Capacity | 2 mL & 15 mL (8 positions) + 100 mL rinse reservoir |
| Flow Rate Range | 40 µL/min to 1 mL/min (water, typical) |
| Pressure Supply | Up to 2 bar |
| Capillary ID/OD | 250 µm / 1.59 mm, FEP material |
| Software | Windows 7 or later |
| Compliance | Designed for GLP-compliant live-cell imaging workflows, compatible with FDA 21 CFR Part 11–ready data logging when integrated with validated software environments |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | Fluigent-Droplet |
| Flow Rate Range | 1.5 µL/min to 5 mL/min (selectable) |
| Maximum Pressure | 0–7 bar |
| Compliance | CE-marked, RoHS-compliant |
| Pump Type | Precision Pneumatic Pressure Controller (FLOW-EZ series) |
| Sensor Integration | Real-time mass flow monitoring with ±1% full-scale accuracy |
| Chip Interface | Standardized PDMS/glass/silicon microfluidic chip mounting via modular夹具 (chip holder) |
| Control Architecture | Standalone or PC-synchronized via Fluigent’s MAESFLO™ software |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fluigent-EISP |
| Pricing | Contact for Quotation |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | Fluigent-perfusion |
| Automation Level | Fully Automated |
| Reservoir Capacity | mL-scale |
| Flow Rate Range | nL/min to mL/min |
| Flow Velocity Range | nL/min to mL/min |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | Flow Unit |
| Flow Range Options | 7 nL/min to 5 mL/min |
| Accuracy | 5–20% MV (varies by range and flow rate) |
| Detection Limit | 3.7 nL/min (XS) to 3 µL/min (XL) |
| Max Pressure | 200 bar (XS/S), 100 bar (M), 12 bar (L), 5 bar (XL) |
| Channel ID | 25 µm to 1.8 mm |
| Construction | PEEK & Fused Silica |
| Compatible Media | Water, Isopropanol |
| Interface | Analog (0–5 V / 4–20 mA) & Digital (I²C, SPI) |
| Supported Platforms | FLOWBOARD (up to 8 units), Flow-EZ, AIO Software |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | FRP Flow Rate Platform (comprising FLOW UNIT sensor + FLOWBOARD controller) |
| Flow Range Options | 7 nL/min to 5 mL/min |
| Sensor Types | XS, S, M, L, XL |
| Communication Interface | USB |
| Max Channels per FLOWBOARD | 8 |
| Software | Fluigent AIO (All-in-One) v3.x |
| Compliance | CE-marked, RoHS-compliant, designed for GLP-compatible lab environments |
| Instrument Category | Microfluidic Chip System |
| Integration | Standalone or embedded in pressure-driven microfluidic control setups |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | MFCS-EX |
| Pressure Range (Positive) | 0–25, 0–69, 0–345, 0–1000, 0–7000 mbar |
| Pressure Range (Negative) | −25–0, −69–0, −345–0, −800–0 mbar |
| Pressure Resolution | 0.03% of full scale |
| Pressure Stability | < 0.1% FS |
| Channels | 1–8 configurable |
| System Response Time | < 40 ms |
| Settling Time | < 100 ms |
| Pressure Input Interface | 6 mm OD tubing |
| Compatible Gases | Non-corrosive, non-explosive (e.g., N₂, CO₂) |
| Power Supply | 24 V / 0.6 A |
| Power Consumption | 15 W |
| Operating Temperature | 5–40 °C |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | MFCS-EX Precision Pressure Controller |
| Pressure Range Options | 0–25 mbar, 0–69 mbar, 0–345 mbar, 0–1000 mbar, 0–7000 mbar, −25 to 0 mbar, −69 to 0 mbar, −345 to 0 mbar, −800 to 0 mbar |
| Pressure Resolution | 0.03% of full scale |
| Pressure Stability | < 0.1% FS |
| Number of Independent Channels | 8 |
| System Response Time | < 40 ms |
| Settling Time | < 100 ms |
| Pressure Input Interface | 6 mm OD tubing |
| Compatible Gases | Non-corrosive, non-explosive gases (e.g., N₂, CO₂) |
| Power Supply | 24 V DC, 0.6 A |
| Power Consumption | 15 W |
| Operating Temperature | 5–40 °C |
| Software Integration | Fluigent’s proprietary Flow Control Software (FCS) with real-time monitoring and scripting support |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | MFCS-EZ |
| Pressure Range (Positive) | 0–25, 0–69, 0–345, 0–1000, or 0–7000 mbar |
| Pressure Range (Negative) | −25 to 0, −69 to 0, −345 to 0, or −800 to 0 mbar |
| Pressure Resolution | 0.03% of full scale |
| Pressure Stability | <0.1% FS |
| Channels | 4 standard (1–8 configurable) |
| System Response Time | <40 ms |
| Settling Time | <100 ms |
| Pressure Input Interface | 6 mm OD tubing |
| Compatible Gases | Non-corrosive, non-explosive (e.g., N₂, CO₂) |
| Power Supply | 24 V / 0.6 A |
| Power Consumption | 15 W |
| Operating Temperature | 5–40 °C |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | MFCS-EZ |
| Instrument Type | Pressure-Driven Microfluidic Flow Controller |
| Flow Rate Range | 1 nL/min to 300 µL/min |
| Pressure Range | −800 mbar to +7 bar |
| Pressure Resolution | 0.03% of full scale |
| Pressure Stability | < 0.1% FS |
| Channel Count | 1–4 independently controllable channels |
| System Response Time | < 40 ms |
| Settling Time | < 100 ms |
| Pressure Input Interface | 6 mm OD tubing |
| Compatible Gases | Non-corrosive, non-explosive (e.g., N₂, CO₂) |
| Power Supply | 24 V DC, 0.6 A |
| Power Consumption | 15 W |
| Operating Temperature | 5–40 °C |
| Software Integration | Real-time pressure & flow feedback loop with optional integrated flow sensor |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | NIFS |
| Liquid Mass Flow Accuracy | ±5% of measured value |
| Flow Range | 100 µL/min to 10 mL/min |
| Minimum Detectable Flow Increment | 5 µL |
| Response Time (Reading) | ~10 s |
| Calibration Time (if required) | 10–30 s |
| Contactless Operation | Yes |
| Bidirectional Flow Monitoring | Yes |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | OEM Precision Pressure Controller |
| Pressure Range Options | 0–25 mbar, 0–69 mbar, 0–345 mbar, 0–1000 mbar, 0–7000 mbar, −25–0 mbar, −69–0 mbar, −345–0 mbar, −800–0 mbar |
| Pressure Resolution | 0.03% of full scale |
| Pressure Stability | <0.1% FS |
| Number of Channels | 1–8 (independently configurable) |
| System Response Time | <40 ms |
| Settling Time | <100 ms |
| Pressure Input Interface | 6 mm OD tubing |
| Compatible Gases | Non-corrosive, non-explosive gases (e.g., N₂, CO₂) |
| Power Supply | 24 V DC, 0.6 A |
| Power Consumption | 15 W |
| Operating Temperature | 5–40 °C |
| Software Integration | Fully programmable via Fluigent’s MAESFLO™ and AFM software suites |
| Compliance | Designed for integration into ISO 13485–aligned instrumentation |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | OMI |
| Instrument Type | Fully Automated, Battery-Powered |
| Reservoir Capacity | 4 × 4 mL |
| Device Height | 6 cm |
| Footprint | < 12 cm × 8 cm |
| Weight | < 800 g |
| Flow Rate Range | 0.1–100 µL/min (adjustable per channel) |
| Flow Control Precision | ±2% CV |
| Operating Environment | Standard CO₂ incubator (37 °C, 5% CO₂) |
| Power | Rechargeable Li-ion battery (2 h continuous operation) |
| Connectivity | Wi-Fi & Bluetooth 5.0 |
| Control Interface | Web-based dashboard & tablet app |
| Data Storage | Encrypted cloud sync with local backup |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | P-OEM |
| Pressure Range | −800 mbar to +7000 mbar |
| Resolution | 0.03% of full scale |
| Stability | < 0.1% FS |
| Channels | 1–8 configurable |
| Response Time | < 40 ms |
| Settling Time | < 100 ms |
| Input Interface | 6 mm OD tubing |
| Compatible Gases | Non-corrosive, non-explosive (e.g., N₂, CO₂) |
| Power Supply | 24 V / 0.6 A |
| Power Consumption | 15 W |
| Operating Temperature | 5–40 °C |
| Software Support | AIO, MAT, SDK (C/C++, MATLAB, Python, LabVIEW, Java, VB) |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | P-OEM-ULTRA |
| Pressure Range | 0–2000 mbar |
| Pressure Resolution | 600 µbar |
| Pressure Stability | < 0.1% |
| Channels | 4 |
| System Response Time | < 60 ms |
| Stabilization Time | < 100 ms |
| Pressure Input Interface | 6 mm OD |
| Compatible Gases | Non-corrosive, non-explosive (e.g., N₂, CO₂) |
| Power Supply | 220 V / 50 Hz |
| Power Consumption | 18 W |
| Operating Temperature | 5–40 °C |
| Dimensions (L×W×H) | 220 × 100 × 177 mm |
| Software Support | AIO, MAT, SDK (C/C++, MATLAB, Python, LabVIEW, Java, VB) |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | p-pump |
| Pump Type | Pressure-Driven Microfluidic Pump |
| Flow Rate Range | 7.5 nL/min – 5 mL/min |
| Rotational Speed | 1–100 rpm |
| Operating Pressure Range | −800 mbar to +7 bar (configurable ranges available) |
| Pressure Resolution | 0.03% of full scale |
| Pressure Stability | < 0.1% FS |
| Response Time | < 40 ms |
| Channels | 1–16 (modular) |
| Fluid Compatibility | Aqueous, organic, viscous, and particle-laden solutions |
| Compatible Gases | Air, N₂, CO₂, Ar |
| Power Supply | 24 V DC, 0.6 A |
| Power Consumption | 15 W |
| Operating Temperature | 5–40 °C |
| Compliance | CE, RoHS, compatible with GLP/GMP workflows via audit-trail-capable software integration |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | Push-Pull |
| Flow Rate Range | 1.5 µL/min – 5 mL/min |
| Pressure Range | −800 mbar to +1000 mbar |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | PX |
| Pressure Ranges | 0–1000 mbar |
| Stability (Std. Dev.) | ±0.06% of full scale |
| Operating Temperature | 4–37 °C |
| Storage Temperature | 0–50 °C |
| Dimensions | 82.4 × 25.7 × 67.9 mm |
| Weight | 192 g |
| Power Supply | 24 VDC |
| Max. Power | 2 W |
| Max. Current | 80 mA |
| Interfaces | RS232, USB |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Fluigent-PLGA |
| Chip Type | Raydrop™ |
| Chip Material | Fluorinated Ethylene Propylene (FEP) with Integrated Glass Viewing Window |
| Detection Limit | Sub-micron droplet resolution via high-speed digital microscopy |
| Channel Dimensions | 1–50 µm (standard Raydrop chip configurations) |
| Target Analyte | Poly(lactic-co-glycolic acid) (PLGA) micro/nanoparticles |
| Solvent Compatibility | Ethyl acetate, dichloromethane, acetonitrile, and other low-surface-tension organic solvents |