FPI (Fortune Photonics Instrumentation)
Filter
Showing all 11 results
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | BFA-3000 |
| Application Mode | Portable & Online Dual-Mode |
| Depth Rating | Up to 200 m submersible |
| Measurement Principle | In vivo chlorophyll a fluorescence excitation with multi-wavelength LED array |
| Compliance | Designed for field-deployable water quality monitoring per ISO 10260, ASTM D3731, and EPA Method 445.0 (Chlorophyll a by in vivo fluorescence) |
| Data Output | Real-time spectral fluorescence response, taxonomic group quantification (e.g., Cyanobacteria, Diatoms, Green Algae, Cryptophytes), Chl-a concentration (µg/L), and vertical profile logging |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Country of Origin | China |
| Model | BPM-200 |
| Measurement Principle | Beta-Ray Attenuation Method (β-ray) |
| Safety Rating | Explosion-Proof (Class I, Division 1, Group A–D compliant per UL 1203 / IEC 60079-0) |
| Sampling Flow Rate | 16.7 L/min (standardized per ISO 10473 and EPA PM2.5 Reference Method EQPM-0805-190) |
| Particle Size Cuts | TSP, PM₁₀, PM₂.₅ (interchangeable impactors) |
| Compliance | Meets technical requirements of HJ 653–2013 (China), EN 12341:2014, and compatible with US EPA Federal Equivalent Method (FEM) framework for continuous ambient PM monitoring |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS-2000 D |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measured Parameters | SO₂, NOₓ (NO + NO₂), O₂, H₂O (wet-basis) |
| Analytical Methods | Ultraviolet Fluorescence (SO₂), Chemiluminescence (NOₓ), Capacitive Humidity Sensing (H₂O), Zirconia Electrochemical Cell (O₂) |
| System Architecture | Dilution-extractive sampling with integrated calibration, data acquisition, and communication modules |
| Compliance Framework | Designed to support compliance with GB/T 16157, HJ 75–2017, HJ 76–2017, and compatible with EPA Method 6C / 7E / 3A / 4 for reference equivalence |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | GC955-615/815 |
| Detection Principle | Gas Chromatography with Dual FID/PID Detection |
| Instrument Type | Online Continuous Analyzer |
| Configuration | Modular VOC Monitoring System |
| Detection Range | 0–300 ppb (user-selectable) |
| Detection Limit | 0.4 µg/m³ (trans-2-butene) |
| Repeatability | <3% RSD at 10 ppb (trans-2-butene) |
| Analysis Cycle | 30 minutes |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–95% RH |
| Power Supply | 220 VAC ±10% |
| Carrier Gas Flow Control | MFC (0–10 mL/min) |
| Preconcentrator Thermal Desorption Time | <10 s |
| Calibration | 5-point manual + automated sensitivity verification |
| Data Interface | Analog (4–20 mA) and digital (RS-485, Modbus TCP) compliant |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Ambient Air VOCs & Hydrocarbon Monitoring System |
| Measurement Principle | Dual-Channel GC-FID with Valve-Switched Cut-and-Backflush Separation |
| Detection Method | Flame Ionization Detection (FID) |
| Analyte Specificity | CH₄ and Total NMHC (C₂–C₁₂ hydrocarbons) |
| Carrier Gas | High-Purity Nitrogen or Helium |
| Hydrogen Fuel Gas | Ultra-High-Purity H₂ (99.999%) |
| Air for Combustion | Clean, Oil-Free Compressed Air |
| Flow Control | Electronic Pressure Control (EPC) and Electronic Flow Control (EFC) for Carrier, H₂, and Air |
| Safety Protocol | Auto-H₂-Shutoff upon Flame-Out Detection |
| Sample Introduction | Integrated Diaphragm Vacuum Pump with 1/8" PTFE-Lined Sampling Line |
| Quantitation Mode | External Standard Calibration with Certified Gas Mixtures |
| Data Output | RS485, Modbus TCP, 4–20 mA Analog Outputs |
| Environmental Operating Range | 5–40 °C, 20–90 % RH (non-condensing) |
| Power Supply | 220 VAC ±10 %, 50/60 Hz, 800 W Max |
| Enclosure Rating | IP54 Industrial Cabinet |
| Compliance | Meets CNEMC Guideline HJ 1012–2018, ASTM D6348–20, ISO 12010:2012 (for FID-based hydrocarbon analysis), GLP-Ready Data Logging |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Online Continuous Emission Monitor |
| Detection Principle | Dual-Detector Gas Chromatography (GC-PID/GC-FID) |
| Sample Introduction | Stepper Motor-Driven Piston Sampling System with Temperature/Pressure Compensation |
| Preconcentration | Integrated Tenax TA or Cryo-Focused Trap with Thermal Desorption |
| Separation Architecture | Two-Dimensional GC (2D-GC) with Primary Pre-Separation Column and Analytical Capillary Column |
| Detector Configuration | Photoionization Detector (PID) + Flame Ionization Detector (FID) |
| Data Acquisition & Control | Embedded Industrial PC with Real-Time OS |
| Communication Interfaces | Ethernet, RS-232 (COM), USB, 4–20 mA Analog Output, Digital I/O |
| Compliance Support | Designed for EPA TO-15 / TO-17 alignment, compatible with ISO 8573-6 (hydrocarbon analysis in ambient air), supports audit-ready data logging per GLP/GMP principles |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | PAN |
| Pricing | Available Upon Request |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Model | WCS-3000 |
| Power Supply | 220 V AC |
| Operating Temperature | 5–45 °C |
| Relative Humidity | 0–95 % RH (non-condensing) |
| Enclosure Rating | IP65 |
| Impact Resistance | IK08 |
| Display | 7" TFT LCD touchscreen (800 × 480 resolution, LED backlight, 154 × 86 mm visible area) |
| Communication | RS485, Modbus RTU protocol |
| Data Storage | ≥1 year local history (timestamped, non-volatile) |
| Dimensions | 235 × 185 × 117 mm (W × H × D) |
| Housing Material | Flame-retardant polycarbonate (UL94-V0 certified) |
| Analog Outputs | None |
| Relay Outputs | None |
| Digital I/O | RS485 only |
| Expandable Probes | Optional integration of phycocyanin (blue-green algae), chlorophyll-a, and UV-absorbance-based COD estimation sensors |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Mars-400 Plus |
| Instrument Type | Portable GC-MS |
| Mass Range | 15–550 amu |
| Mass Resolution | Unit mass resolution |
| Detection Limit | < ppb (for selected VOCs/SVOCs) |
| Maximum Scan Rate | 10,000 amu/s |
| Sensitivity | Optimized for trace-level detection in field conditions |
| Weight | 17 kg |
| Power Supply | Integrated rechargeable battery pack |
| Carrier Gas | Built-in helium or hydrogen micro-gas cylinder (optional) |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Model | OMA-3010 |
| Measurement Principle | UV Absorption Spectrophotometry (220–360 nm) |
| Detection Range | 0–1 ppm and 0–10 ppm (auto-switching dual-range) |
| Detection Limit | <50 ppb Cl₂ |
| Sample Gas Temperature | –10 to 60 °C |
| Sample Pressure | 0.05–0.3 MPa (gauge) |
| Corrosion Resistance | Hastelloy C-276 wetted parts, PTFE/PFA-lined flow path |
| Output Interface | 4–20 mA, RS485, Modbus TCP |
| Compliance | CE, RoHS, ISO 9001 certified |
| Enclosure Rating | IP65 |
| Operating Environment | Indoor/Outdoor (with shelter), –20 to +50 °C ambient |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | ProGC Series |
| Pricing | Available Upon Request |