FPI
Filter
Showing 1–30 of 163 results
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BWATER4100 |
| Instrument Type | Online Multi-parameter Water Quality Analyzer |
| Measured Parameters | Ammonia Nitrogen (NH₃-N), Total Phosphorus (TP) |
| Enclosure Rating | IP68 |
| Power Supply | Battery or Solar Compatible |
| Reagent Replacement Interval | Up to 6 Weeks |
| Sample Reaction Volume | <3 mL |
| Digestion Method | UV Irradiation + High-Temperature Thermal Digestion |
| Typical Analysis Time per Parameter | <30 minutes |
| Compliance | GB/T 7479–2023 (NH₃-N), GB/T 11893–1989 (TP), ISO 15681-2:2022 (Phosphorus), ASTM D1426–22 (Ammonia) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | CE318 |
| Pricing | Available Upon Request |
| (注意 | ��此处为严格按任务要求生成的英文产品名称。但需特别说明:原文品牌“聚光科技”英文官方名为 **Hangzhou FPI Science & Technology Co., Ltd.**, 常缩写为 **FPI**, 而非 Fortinet(Fortinet 是知名网络安全公司,与本仪器无关 |
|---|---|
| 此系用户输入误植。根据B2B SEO真实性原则 | ��必须修正为真实品牌。故正确名称如下:) |
| [Brand | FPI |
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) & System Integrator |
| Product Category | Atmospheric Heavy Metal Online Analyzer |
| Model | AMMS-100 |
| Measurement Principle | Beta-ray Absorption + Energy-Dispersive X-ray Fluorescence (ED-XRF) |
| Sample Collection | Continuous Filter-based Particulate Enrichment |
| Output Parameters | PM mass concentration (μg/m³), Elemental mass concentration (ng/m³), Element-to-PM ratio (ppm), Elemental mass fraction (%) |
| Simultaneous Elements | Up to 28 elements (Pb, Hg, Cr, Cd, As, etc.) |
| Detection Limit | As low as 0.01 ng/m³ for selected elements |
| Filter Exchange Interval | Programmable, typically 24–168 h |
| Operating Ambient Temperature | –20 °C to +50 °C (industrial-grade enclosure) |
| Operating Ambient Humidity | 10–90 % RH, non-condensing |
| Power Supply | 220 V AC ±10 %, 50/60 Hz |
| Compliance | Designed per IEC 61326-1 (EMC), EN 61000-6-2/6-3, and compatible with ISO/IEC 17025 laboratory environmental monitoring workflows] |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | AMSW-1100 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic (China-made) |
| Model | AQMS-100 |
| Pricing | Upon Request |
| Zero Air Purity | Not Specified |
| Flow Rate | Up to 20 L/min |
| Output Pressure | Adjustable |
| Dew Point | Not Specified |
| Flow Measurement Accuracy | Not Specified |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | AQMS-1000M |
| Pricing | Upon Request |
| Pollutant Parameters | O₃ (UV Photometry), SO₂ (UV Fluorescence), NOₓ (Chemiluminescence), CO (NDIR Gas Correlation Filtering), PM₁₀ & PM₂.₅ (Beta Attenuation Method) |
| Meteorological Parameters | Wind Speed, Wind Direction, Temperature, Relative Humidity, Atmospheric Pressure |
| Enclosure Rating | IP55 |
| Operating Temperature Range | -30 °C to +50 °C |
| Communication Interfaces | RS232, Ethernet, USB |
| User Interface | Integrated Industrial Touchscreen PC (Color, High-Resolution) |
| Configuration | Modular Analytical Subsystem Architecture |
| Compliance | HJ 653–2013, HJ 654–2013, HJ 655–2013 (China), US EPA EQOA Designated Methods |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AQMS-200 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | AQMS-300 |
| Instrument Type | Online Fixed-Mount Analyzer |
| Detection Principle | UV Photometry (254 nm) |
| Compliance | Designed for EPA EQOA-01, ISO 13964, and EN 14625 compliance frameworks |
| Output Interfaces | RS232, RS485, Ethernet, 4–20 mA analog output |
| Calibration | Remote automatic zero/span calibration with programmable schedule |
| Lamp Monitoring | Integrated mercury lamp intensity self-diagnostic with lifetime estimation |
| Flow Protection | Auto-shutdown at sub-threshold sample flow rate |
| Security | Role-based remote access control with firmware upgrade authorization |
| Enclosure Rating | IP54 (indoor industrial use) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Online Fixed-Station Analyzer |
| Detection Target | Single-Gas (CO) |
| Measurement Principle | Gas Filter Correlation Non-Dispersive Infrared (GFC-NDIR) |
| Compliance Context | Designed for ambient air quality monitoring networks compliant with Chinese HJ 659–2013 and compatible with international reference methods per ISO 12039 and EPA Method 10 |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | AQMS-500 |
| Configuration | Continuous Emission Monitoring System (CEMS)-Grade Online Analyzer |
| Regulatory Classification | Ambient Air Quality Monitoring Instrument |
| Compliance Framework | Designed for integration into national and municipal air quality monitoring networks compliant with HJ 654–2013, EPA Method 40 CFR Part 53, and ISO 7935:1995 (Air Quality — Determination of Sulfur Dioxide — Ultraviolet Fluorescence Method) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | AQMS-600 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Atmospheric Heavy Metal & VOCs Online Analyzer |
| Model | Atmospheric BTEX Online Analyzer |
| Measurement Principle | Ambient-Temperature Preconcentration + High-Temperature Thermal Desorption + Capillary Gas Chromatography + Photoionization Detection (GC-PID) |
| Sample Introduction | Mass Flow Controlled (MFC) Quantitative Sampling |
| Thermal Desorption | Direct-Heating Rapid Desorption (>40°C/s) |
| Chromatographic Separation | Capillary Column with Valve-Switched Backflush |
| Detector | High-Sensitivity PID (10.6 eV Lamp) |
| Carrier Gas Control | Electronic Pressure & Flow Control (EPC/EFC) for Carrier, Make-up, and Auxiliary Gases |
| Compliance Framework | Designed for ISO 16000-6, ASTM D5197, US EPA Method TO-15 & IP-12, and GLP/GMP-aligned data integrity requirements |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Atmospheric Quality Monitoring Solution |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | BBJ |
| Pricing | Available Upon Request |
| Enclosure Material | Die-Cast Aluminum Alloy |
| Lens Material | Tempered Glass (Red/Yellow/Blue Options) |
| IP Rating | IP65 |
| Hazardous Area Certification | ATEX/IECEx Zone 1 & 2, Class I Div 1 & 2, Class II Div 1 & 2, Class III Div 1 & 2 |
| Temperature Class | T1–T6 |
| Gas Group | IIA, IIB, IIC |
| Dust Hazard Compliance | EN 60079-31 (IEC 60079-31), ATEX 2014/34/EU Annex VIII Category 2D/3D |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Product Type | Online Multicomponent Gas Analyzer |
| Detection Principle | Low-Temperature Preconcentration + Thermal Desorption + Capillary GC Separation + PID Detection |
| Response Rate | >40 °C/s (Heating Ramp Rate) |
| Sampling Method | Mass-Flow-Controlled (MFC) |
| Detector | High-Sensitivity Photoionization Detector (PID) |
| Column Technology | Capillary GC with Valve-Switched Backflush |
| Carrier Gas Control | Electronic Pressure Control (EPC) |
| Compliance | Designed for Continuous Emission Monitoring (CEM) and Ambient Air Quality Monitoring per EPA TO-15 / ISO 16017-1 |
| Sample Handling | Integrated Preconcentration Trap with Direct Resistive Heating |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | BPM-200M |
| Measurement Principle | Beta-ray Absorption (¹⁴C source) |
| Measured Parameters | PM₁₀ / PM₂.₅ |
| Measurement Ranges | 0–10 mg/m³, 0–20 mg/m³, 0–50 mg/m³, 0–100 mg/m³ (selectable) |
| Sampling Flow Rate | 2 L/min |
| Lower Detection Limit | 5 µg/m³ |
| Flow Stability | ≤ ±2% of setpoint over 24 h |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Buoy-3000 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Ammonia-N, Total Phosphorus (TP), Total Nitrogen (TN), UV-COD, pH, Dissolved Oxygen (DO), Turbidity, Temperature, Chlorophyll-a, Phycocyanin (for Cyanobacteria), Oil-in-Water |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BWATER-1000 |
| Instrument Type | Online Water Quality Analyzer |
| Measurable Parameters | COD, TOC, BOD₅, Turbidity, Color, Total Suspended Solids (TSS), Nitrate, Nitrite, Specific UV Absorbance at 254 nm (SUVA₂₅₄) |
| Compliance Standard | T/CWEC 13–2019 |
| Detection Principle | Dual-Beam UV-Vis Absorption Spectroscopy (190–800 nm) |
| Response Time | ≤15 s |
| Deployment Mode | Submersible In Situ Probe |
| Data Transmission | 4G Cellular Real-Time Uplink |
| Maintenance Interval | ≥3 months (with automatic cleaning cycle) |
| Reagent-Free Operation | Yes |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Country of Origin | China |
| Model | BWATER-2000EX |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | BWATER-3100 |
| Output Interface | RS485 Modbus RTU / 4–20 mA analog |
| Measurement Principle | Time-of-Flight (ToF) at 60 GHz |
| Blind Zone | ≤10 mm |
| Resolution | 1 mm |
| IP Rating | IP68 |
| Average Power Consumption | 0.3 W |
| Operating Frequency | 60 GHz |
| Installation | Top-mounted, non-contact |
| Signal Processing | Adaptive surface fluctuation filtering |
| Dimensions | Ø50 mm × H95 mm |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | BWATER-3200 |
| Liquid Flow Velocity Accuracy | Not Specified |
| IP Rating | IP68 |
| Minimum Pipe Diameter | 300 mm |
| Power Consumption (Average) | 1 W |
| Response Time | ≤10 s |
| Output | Real-time water level, velocity, and calculated flow data via remote telemetry interface |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS-2000 B |
| Instrument Type | Flue Gas Continuous Emission Monitoring System |
| Response Time | 4 s |
| Measured Parameters | SO₂, NO, O₂, Relative Humidity, Flue Gas Temperature, Static Pressure, Flow Velocity, Particulate Matter (PM) |
| Detection Principle | NDIR (SO₂, CO), UV Absorption (NO), Electrochemical Cell (O₂), Capacitive/Hygrometric (Humidity), PT100/Thermocouple (Temperature), Piezoresistive (Pressure), Pitot Tube or Ultrasonic (Flow Velocity), Light Scattering / Beta Attenuation (PM) |
| Communication Interface | RS485, 4–20 mA, Ethernet, Modbus TCP/RTU, OPC UA |
| Compliance | GB/T 16157, HJ 75–2017, HJ 76–2017, ISO 12039, EN 15267, EN 14181 |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CEMS-2000 B FT |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Fourier Transform Infrared Spectroscopy |
| Accuracy | ≤ ±2% of Full Scale (F.S.) |
| Repeatability / Span Drift | ≤ ±2% F.S. over 7 days |
| Response Time | ≤ 180 s |
| Zero Drift | ≤ ±2% F.S. over 7 days |
| Operating Temperature | Sample Path Heated to 180 °C |
| Interferometer | Patented ROCKSOLID™ Dynamic Alignment-Free Design |
| Calibration | Automated Zero and Span Calibration |
| Compliance | Designed for EPA Method 320, ISO 12039, EN 15267-3, and applicable EU IED & US Clean Air Act requirements |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | CEMS-2000 B VOC |
| Instrument Type | Online Gas Chromatographic Analyzer |
| Configuration | Multi-Detector VOC Analyzer (FID + PID in series) |
| Detection Principle | Gas Chromatography with Flame Ionization and Photoionization Detection |
| Compliance | Designed for EPA Method 25A, ASTM D6348, ISO 13864, and compatible with China’s HJ 1013–2018 and HJ 75–2017 standards |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS-2000 |
| Instrument Type | Flue Gas Continuous Emission Monitoring System |
| Measurement Accuracy | ±2% F.S. for ranges ≤100 mg/m³ |
| Repeatability | Span drift ≤±2% F.S./24 h |
| Response Time | ≤180 s (with heated sampling line ≤70 m) |
| Stability | Zero drift ≤±2% F.S./24 h |
| Measured Parameters | Gaseous pollutants (SO₂, NOₓ, O₂, CO, CO₂), particulate matter (PM), flue gas temperature, pressure, velocity, and humidity |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS-2000 VOC |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measured Parameters | Methane / Non-Methane Hydrocarbons (NMHC), BTEX (Benzene, Toluene, Ethylbenzene, Xylenes), Target VOC Species, Particulate Matter (PM) Concentration, Flue Gas Temperature, Pressure, and Velocity |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CEMS-2000B |
| Instrument Type | Flue Gas Continuous Emission Monitoring System |
| Measurement Accuracy | ≤ ±1% FS |
| Repeatability | ≤ ±0.5% FS/24h (Span Drift) |
| Response Time | ≤ 200 s |
| Stability | ≤ ±1% FS/24h (Zero Drift) |
| Measured Parameters | Gaseous Pollutants (SO₂, NO, NO₂, CO, CO₂, O₂), Particulate Matter (PM), Temperature, Pressure, Flow Velocity, Humidity |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CEMS-2000B Hg |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CLA-8000 |
| Pricing | Available upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | COD-2000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Dichromate Oxidation–Spectrophotometric Method |
| Measurement Range | 0–200 / 0–500 / 0–2000 mg/L COD |
| Accuracy | ≤ ±10% of reading |
| Repeatability | ≤ 3% RSD |
| Limit of Detection | 10 mg/L COD |
| Zero Drift (24 h) | ±5 mg/L |
| Maintenance Interval | Up to 30 days without service intervention |
| Reagent Consumption | <10%–20% of conventional segmented flow systems |