| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LB8110 Plus |
| Instrument Type | Quaternary Pump (Note: “Six-solvent pump” in source is inconsistent with “quaternary” specification |
| Price Range | USD 7,000 – 14,000 (converted at ~¥7.2/USD) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LB8131 |
| Price Range | USD 2,800 – 7,000 |
| Temperature Control | Active Cooling & Heating via Thermoelectric (Peltier) Module |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LB8170 |
| Instrument Type | Differential Refractometer Detector (RID) |
| Wavelength Range | 190–900 nm |
| Detection Method | Dual-Beam |
| Light Source | Deuterium Lamp |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SFC-24 |
| Price Range | USD 2,800 – 7,000 |
| Pump Type | Single-Channel High-Pressure Pump |
| Operating Modes | Constant Flow & Constant Pressure |
| Temperature Control | Peltier-based Active Cooling System |
| Communication Interface | RS-232 |
| Remote Control | Start/Stop via TTL or Dry Contact |
| Pressure Monitoring | Real-time Digital Readout with Setpoint Adjustment |
| Compliance | Designed for SFC Method Development per ASTM D7042 & ISO 16063 |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | Image Analysis V3.0 |
| Price Range | USD 0–70 (Training-Only Engagement) |
| Training Experience | 15+ Years |
| Instrument Type | Software-Based Image Analysis Platform |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Lanbo AS |
| Instrument Type | Liquid Chromatography Autosampler |
| Compliance | Designed for ASTM D4790, USP <621>, and ISO 17025-accredited laboratories |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Lanbo |
| Instrument Type | Liquid Chromatography Autosampler |
| Sample Capacity | 120 vials (3 trays), 105 vials under refrigeration |
| Injection Precision | <0.1% RSD @ 5 µL and @ 10 µL |
| Injection Volume Range | 0.1–100 µL (standard 250 µL loop) |
| Sample Temperature Control | Peltier-based cooling/heating, 0–60 °C in 1 °C increments |
| Vial Mixing/Heating | Pneumatic vortex mixer + heater per vial, 1 °C resolution |
| Dilution Accuracy | <1.0% RSD for 1:1000 dilution (10 µL → 1 mL) |
| Dispensing Accuracy | <0.2% RSD when adding 1 mL solvent externally |
| Method Storage | Protected memory file system |
| Communication Interface | RS-232 |
| Operating Environment | 10–40 °C, 5–95% RH (non-condensing) |
| Dimensions | 14.5" H × 16" W × 19.5" D |
| Weight | 35.2 lbs (base unit) |
| Power Supply | 220 V, 50/60 Hz |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | BioMonitor |
| Instrument Type | Online BOD Analyzer |
| Measurement Principle | Dissolved Oxygen (DO)-Based Respirometric Method |
| Measurement Range | 1–50 mg/L and 1–200,000 mg/L BOD |
| Detection Limit | 1 mg/L |
| Accuracy | ±2% of reading within both ranges |
| Sample Interval | 3–4 minutes per measurement |
| Repeatability | ±2% RSD |
| Key Specifications | Temperature Range: -40°C to +130°C |
|---|---|
| Humidity Range | 20–98% RH |
| Temperature Uniformity | ±2°C |
| Humidity Uniformity | ±3.0% RH |
| Temperature Fluctuation | ±0.5°C |
| Humidity Fluctuation | ±2.5% RH |
| Heating Rate (air) | ~2.5°C/min (no-load, nonlinear) |
| Cooling Rate (air) | ~1.0°C/min (no-load, nonlinear) |
| Internal Chamber Dimensions (W×D×H) | 3000 × 1000 × 2000 mm |
| External Dimensions (W×D×H) | 3800 × 1300 × 2450 mm |
| Door Opening | 1000 × 1900 mm (outward-swinging) |
| Observation Windows | Front (300 × 450 mm), Left Side (500 × 450 mm) |
| Power Supply | 380 V ±10%, 50/60 Hz |
| Total Power Consumption | ~30 kVA |
| Refrigeration Method | Mechanical compression + water-cooled condenser |
| Humidification System | Stainless-steel steam generator with integrated deionized water purification |
| Dehumidification Method | Surface cooling via refrigerated coil |
| Air Circulation | Extended-shaft centrifugal blower with external motor drive |
| Heating System | Nickel-chromium alloy resistive heaters with PID + SSR control |
| Cooling System | High-efficiency plate-type air-to-refrigerant heat exchanger |
| Sensor Location | At air outlet of HVAC unit |
| Compliance | GB/T 5170.2 (temperature testing), GB/T 5170.5 (humidity testing) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LARRY-USB3648 |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LBC-2 |
| Instrument Type | Benchtop |
| Integration | Fully Integrated |
| Laser Power | 10 mW |
| Laser Wavelength (Standard) | 532 nm |
| Spatial Resolution | 10 µm |
| Scan Area | 50 mm × 50 mm |
| Current Measurement Range | 10 fA – 20 mA |
| XY Stage Travel | ±25 mm (0.01 mm minimum step) |
| Laser Stability | ±5% / h |
| Laser Class | Class 2 (IEC 60825-1) |
| Operating System | Windows 7 (32-bit) |
| Dimensions (W×D×H) | 750 mm × 270 mm × 650 mm (excl. electrometer, stage controller, and PC) |
| Key | Wavelength: 355 nm |
|---|---|
| Repetition Rate (External Trigger Mode) | 200–2000 Hz (200 Hz nominal) |
| Pulse Energy | 20 ±10% mJ @ 200 Hz |
| Pulse Width | 5 ±2 ns (≤7 ns and ≥3 ns @ 200 Hz) |
| Beam Divergence | 3.4 ±0.5 mrad |
| Operating Temperature | 15–35 °C (RH <80%) |
| Manufacturer Origin | Russia |
| Compliance | CE, RoHS, IEC 60825-1:2014 Class 4 Laser Product |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | F01 |
| Price Range | USD 1,350 – 4,050 (based on exchange rate & configuration) |
| Component Category | Optical Safety Element |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XT 150 |
| Pricing | Upon Request |
| Origin | Fujian, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | LawLink |
| Pricing | Available Upon Request |
| Origin | Fujian, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Lawlink System |
| Price Range | USD 70,000 – 140,000 |
| Origin | Fujian, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | LawLink |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | LD-5C |
| Price | ¥27,800 |
| Sampling Method | Real-time Laser Scattering with Optional Filter-Based Gravimetric Validation |
| Particle Size Selectivity | PM₁₀ / PM₅ / PM₂.₅ via Interchangeable Impactors |
| Concentration Range | LD-5C(L): 0.01–100 mg/m³ |
| LD-5C(H) | 0.001–10 mg/m³ |
| Detection Limit | LD-5C(L): 0.1 mg/m³ |
| LD-5C(H) | 0.001 mg/m³ |
| Display | Backlit LCD with Chinese Character Menu |
| Data Storage | 99 Cyclic Records |
| Sampling Duration | Configurable from 0.1 min to user-defined intervals (1–9999 s) |
| Communication Interfaces | RS232 Serial Port, Thermal Printer Output, 0–1 V Analog Output, Digital TTL-Level Output |
| Power Supply | Rechargeable Ni-MH Battery (8 h continuous operation), AC/DC Adapter Included |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | LDZX-50FAS |
| Price | USD 860 (FOB Shanghai) |
| Chamber Volume | 50 L |
| Power Supply | 220 V AC, 50 Hz |
| Heating Power | 3.5 kW |
| Sterilization Chamber Dimensions | Φ350 × 520 mm |
| Net Weight | 75 kg |
| Overall Dimensions | 600 × 580 × 1100 mm |
| Operating Pressure Range | 0.145–0.165 MPa (auto-pressure release) |
| Temperature Range | 116–127 °C (adjustable) |
| Time Setting Range | 0–70 min |
| Safety Features | Low-water cutoff protection, self-sealing gasket, dual-scale Class II pressure gauge, status indicator lights |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LE509 |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | LED-LightBar-COB |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CV5030 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DM2500 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RM2265 |
| Pricing | Available Upon Request |
| Conductivity Range | 0.0 µS/cm to 200 mS/cm |
|---|---|
| Temperature Range | −10.0 to 120.0 °C |
| Accuracy | ±2.0% FS (instrument) |
| Resolution | 0.001 µS/cm (selectable: 0.001 / 0.01 / 0.1 / 1 µS/cm) |
| Dimensions | 166 × 166 × 110 mm |
| Weight | 2 kg |
| IP Rating | IP65 |
| Output | Isolated 4–20 mA DC & RS-485 |
| Sensor Cable Length | 10 m (standard) |
| Auto-Temperature Compensation | −10 to 120 °C |
| Electrode Compatibility | 2-electrode and 4-electrode conductivity cells |
| Data Storage Capacity | 2000 records |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer | Los Gatos Research |
| Type | Imported |
| Model | 908-0004-9002 (Standard Range), 908-0004-9003 (Extended Range) |
| Power Supply | 115/230 VAC, 50/60 Hz |
| Average Power Consumption | 30 W |
| Standby Power | 10 W |
| Max Power | 300 W |
| Dimensions (Std) | 26.7 cm H × 48.3 cm W × 43.2 cm D |
| Weight (Std) | 27 kg |
| Dimensions (Ext) | 26.7 cm H × 48.3 cm W × 58.4 cm D |
| Weight (Ext) | 29 kg |
| H₂O Vapor Range (Std) | 3000–30,000 ppm |
| H₂O Vapor Range (Ext) | 500–30,000 ppm |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | LH-270 |
| Pricing | Available Upon Request |
| Dust Sampling Flow Rate | 10–100 L/min (0.1 L/min resolution, ±2% accuracy) |
| Sampling Duration | 00:00–99:59 h:min (1 min resolution, ±1 s deviation within 20 min) |
| Sampling Cycles | 0–99 programmable |
| Pre-sampler Temperature | −30 to 99 °C (0.1 °C resolution, ±1.0 °C accuracy) |
| Pre-sampler Pressure | −30 to 0 kPa (0.01 kPa resolution, ±2.5% accuracy) |
| Ambient Atmospheric Pressure | 50–130 kPa (0.01 kPa resolution, ±500 Pa accuracy) |
| Built-in Heater Range | 15–30 °C (0.1 °C resolution, ±2.0 °C accuracy) |
| Load Capacity | ≥20 kPa at 50 L/min (flow stability ≤2% over 6 h) |
| Inlet Cut-point | Da₅₀ = (100 ± 1) µm, geometric standard deviation δg = 1.5 |
| Inlet Velocity | 0.3 m/s |
| Effective Filter Diameter | Φ80 mm |
| Inlet Thread | M27×1.5 |
| Inlet Width Tolerance | ≤±2.0% |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LH-3S |
| Instrument Type | Portable |
| Measurement Ranges | 0–100 mg/L and 0–200 mg/L (user-selectable) |
| Limit of Detection | 0.1 mg/L |
| Response Time | ≤1 s |
| Zero Drift | ±0.1 mg/L (24 h) |
| Resolution | 0.1 mg/L |
| Principle | Dual-Wavelength UV Absorption (254 nm & 365 nm) |
| Dimensions | 120 × 260 × 206 mm |
| Temperature Range | –40 °C to +150 °C (optional down to –120 °C) |
|---|---|
| Humidity Range | 30–98% RH (optional 5–98% RH) |
| Temperature Resolution | 0.01 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Deviation | ≤ ±2 °C |
| Humidity Resolution | 0.1% RH |
| Humidity Deviation | ≤ ±2.5% RH |
| Cooling Rate | 0.7–1.0 °C/min |
| Heating Rate | 2.0–3.0 °C/min |
| Control System | TEMI880 Color LCD Touchscreen Programmable Controller |
| Power Supply | 380 V ±5%, 50 Hz, 3P+N+G (220 V optional) |
| Interior Material | SUS304 Stainless Steel |
| Exterior Material | SUS304 Stainless Steel or A3 Steel with Electrostatic Powder Coating |