| Origin | Australia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DT85 Series 2 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vantage Pro 2 |
| Instrument Type | Portable Weather Station |
| Wind Speed Range | 1–67 m/s, Accuracy: ±5% |
| Barometric Pressure Range | 880–1080 hPa, Accuracy: ±1.0 hPa, Resolution: 0.1 hPa |
| Wind Direction Range | 0–360°, Accuracy: ±7°, Resolution: 1° |
| Air Temperature Range | −40 to +65 °C, Accuracy: ±0.5 °C, Resolution: 0.1 °C |
| Relative Humidity Range | 0–100%, Accuracy: ±3%, Resolution: 1% |
| Rainfall Range (Daily) | 0–9999 mm, Accuracy: ±4%, Resolution: 0.2 mm |
| Solar Radiation Range | 0–1800 W/m², Spectral Response: 300–1100 nm, Accuracy: ±5%, Resolution: 1 W/m² |
| UV Radiation Range | 0–199 MEDs, Spectral Response: 290–390 nm, Accuracy: ±5%, Resolution: 0.1 MEDs |
| Soil Temperature Range | −40 to +65 °C, Accuracy: ±0.5 °C, Resolution: 1 °C |
| Leaf Wetness Range | 0–15 units, Accuracy: ±0.5, Resolution: 1 unit |
| Soil Moisture Range | 0–200 cb, Resolution: 1 cb |
| Dew Point Range | −76 to +54 °C, Accuracy: ±1.5 °C, Resolution: 1 °C |
| ET Calculation | Daily/Monthly/Annual, Resolution: 0.1 mm, Accuracy: ±5% |
| Operating Temperature (Console) | −40 to +70 °C |
| Memory Capacity | 128 KB non-volatile |
| Sampling Intervals | 1, 5, 10, 15, 30, 60, or 120 minutes |
| Wireless Transmission Range | Up to 300 m (line-of-sight), typical 60–120 m (obstructed) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | Daxluot-4S |
| Price | USD 6,500 (FOB Shanghai) |
| Ultrasonic Output Power | 2000 W (adjustable) |
| Operating Frequency | 20 kHz |
| Sample Capacity | 4 × 300 mL vessels |
| Pulse Mode | 0.1–99.9 s on/off adjustable |
| Timer Range | 0–99 h 59 min 59 s |
| Temperature Monitoring & Overheat Protection | Ambient to 90 °C |
| Control Interface | 4.3-inch TFT capacitive touchscreen |
| Data Storage | 20 programmable protocols with user password protection |
| Power Supply | AC 220 V ±5%, 50 Hz (110 V option available) |
| Communication Interface | Optional RS-232 or USB-to-PC connectivity |
| Probe Material | Grade 5 titanium alloy (Ti-6Al-4V), corrosion-resistant, USP Class VI compliant |
| Amplitude Stability | Closed-loop amplitude regulation under variable load conditions |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DB-10C |
| Price | Upon Request |
| Heating Set Range | +25 °C to +42 °C |
| Temperature Control Range | Ambient +5 °C to +42 °C |
| Stability | ±0.1 °C |
| Uniformity | ±0.3 °C |
| Resolution | 0.1 °C |
| Display | Dual-line LCD |
| Heating Time (RT → 42 °C) | ≤15 min |
| Capacity | 10 × 10-mm-path cuvettes |
| Timer Range | 1–96 h |
| Power Supply | 12 V DC, 1 A |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Model | DB-2 |
| Price | USD 110 (FOB) |
| Construction | 304 Stainless Steel Top Plate |
| Temperature Range | Ambient to 300 °C |
| Working Surface Dimensions | 300 mm × 200 mm |
| Heating Power | 800 W |
| Control Type | Digital PID Controller with LED Display |
| Temperature Stability | ±2 °C at 250 °C (typical, load-dependent) |
| Surface Flatness | ≤0.1 mm/m |
| Electrical Supply | 220–240 V AC, 50/60 Hz |
| Safety Features | Over-temperature cut-off, thermal fuse, non-slip rubber feet |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Model | DB-3B |
| Price | USD 180 (excl. VAT & shipping) |
| Surface Material | 304 Stainless Steel |
| Temperature Range | Ambient to 300 °C |
| Working Area | 400 × 300 mm |
| Heating Power | 1500 W |
| Display | LED Digital Thermoregulator |
| Control Accuracy | ±2 °C (typical, at steady state) |
| Sensor Type | Embedded Pt100 RTD |
| Over-Temperature Protection | Yes (auto-cut-off at 320 °C) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DC-0504B |
| Pricing | Available Upon Request |
| Origin | Taiwan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China Market) |
| Model | DCG-R |
| Price Range | USD 420–1,400 |
| Instrument Type | Electric Stirrer |
| Max. Mixing Volume | 20 L |
| Speed Range | 200–3000 rpm |
| Temperature Resistance | Ambient to 340 °C (housing & shaft assembly) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DDB-2 / DDB-3 |
| Portability | Handheld |
| Conductivity Range | 1 µS to 100 mS (5 auto-ranging decades) |
| Accuracy | ±1.5% FS |
| Temperature Compensation Error | <±2% |
| Stability | ±0.1% FS ±1 digit/hour |
| Weight | 380 g (incl. batteries) |
| Dimensions | 180 × 100 × 40 mm |
| Power | Two AA (1.5 V) batteries |
| Operating Temp | 0–45 °C |
| RH Limit | ≤85% |
| DDB-3 Additional Function | Integrated Temperature Measurement (–10 to 100 °C, resolution 0.1 °C) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DDS-307 |
| Pricing | Available Upon Request |
| Display | 3.5-digit LED |
| Temperature Compensation | Manual, 15.0–35.0 °C |
| Temp. Coefficient | 2 %/°C |
| Output Signal | 0–10 mV DC |
| Electrode Compatibility | DJS-1C platinized platinum electrode (standard), optional Ti alloy electrode (K = 0.01 cm⁻¹) |
| Measurement Range | 0.00 μS/cm to 100 mS/cm |
| Accuracy | ±0.5% FS |
| Stability | (±0.33% FS ±1 digit)/3 h |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Dimensions (W×D×H) | 290 × 210 × 95 mm |
| Weight | 1.5 kg |
| Enclosure Code | WXS-A000-1 |
| Electrode Constant Calibration Support | K = 0.01, 0.1, 1.0, 10.0 cm⁻¹ |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DDS-307A |
| Price | USD 230 (FOB Shanghai) |
| Accuracy Class | 1.0 |
| Conductivity Range | 0–1.999 μS/cm, 2.0–19.99 μS/cm, 20.0–199.9 μS/cm, 200–1999 μS/cm, 2.0–19.99 mS/cm, 20.0–199.9 mS/cm |
| Temperature Range | –5 to 105 °C |
| Conductivity Accuracy | ±1.0% FS |
| Temperature Accuracy | ±0.5 °C |
| Temp. Compensation | 0–100 °C, Coefficient 2.0%/°C |
| Electrode Constants Supported | 0.01, 0.1, 1.0, 10.0 cm⁻¹ |
| Display | Backlit LCD, Multi-parameter |
| Auto Functions | Auto-ranging, Auto-calibration, Auto-temperature compensation |
| Measurement Modes | Conductivity, Resistivity, TDS, Temperature |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DDS-5000 |
| Pricing | Available Upon Request |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Deasphaltop |
| Pricing | Available Upon Request |
| Key | Origin: USA |
|---|---|
| Manufacturer | Deben Ltd. |
| Distributor | Optosky Co., Ltd. |
| Type | Imported |
| Model | MICROTEST |
| Load Capacity Options | 200 N, 300 N, 2000 N, 5000 N |
| Strain Rate Range | 5 µm/min – 6 mm/min |
| Force Sensor Resolution | Down to 2 N |
| Bending Configurations | Horizontal 3-point & 4-point |
| EBSD-Compatible Versions | MICROTEST2000ES/EW, MICROTEST5000S/W |
| Thermal Options | RT, Heated (EH2000/H5000), Water-Cooled (MICROTEST2000W/5000W) |
| Software | Real-time stress–strain plotting with threshold-triggered acquisition and synchronized image–data capture |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OMD-24 / OMD-15 |
| Instrument Type | Online |
| Measurement Principle | Fluorescence-based Optical Detection (IMO MEPC.107(49)-compliant) |
| Measurement Range | 0–30 ppm (trending up to 50 ppm), IMO-compliant range: 0–15 ppm |
| Detection Limit | < 2% of full scale |
| Accuracy | ±1% FS |
| Resolution | 0.1 ppm |
| Measurement Frequency | User-adjustable |
| Linearity | ±2% FS |
| Power Supply | 24 V AC/DC ±10% |
| Power Consumption | < 10 VA |
| Sample Flow Rate | 0.1–4 L/min |
| Sample Temperature Range | +1 °C to +65 °C |
| Process Connection | R ¼" internal thread |
| Alarm Setpoints | Two independent, adjustable within 1–15 ppm (default: 15 ppm) |
| Alarm Delay (Point 1) | 1–540 s (default: 2 s) |
| Control Delay (Point 2) | 1–20 s (default: 10 s) |
| Relay Output | Passive, 3 A / 240 V AC/DC |
| Analog Output | 4–20 mA, max. load < 150 Ω |
| Display | Graphical LCD |
| Ambient Operating Temperature | +1 °C to +55 °C |
| Enclosure Rating | IP65 |
| Dimensions (Control Unit) | 185 × 210 × 65 mm (W×H×D) |
| Dimensions (Measurement Cell) | 140 × 160 × 65 mm (W×H×D) |
| Weight | 2.5 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Deep UV Bandpass Filter |
| Price Range | USD 140–420 |
| Component Category | Optical Element |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Definer220 |
| Pricing | Available Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PR2 |
| Pricing | Upon Request |
| Measurement Range | 0–0.4 m³·m⁻³ (0–40% vol) |
| Accuracy | ±0.04 m³·m⁻³ (0–40 °C, soil-specific calibration) |
| Salinity Tolerance | ≤600 mS·m⁻¹ (pore water EC) |
| Operating Temperature | −20 to +70 °C (guaranteed accuracy: 0–40 °C) |
| IP Rating | IP67 (sensor body), IP68 (M12 connector) |
| Response Time | <1 s |
| Power Supply | 5.5–15 V DC |
| Current Draw | <80 mA (PR2/4), <120 mA (PR2/6) |
| Output | 4 or 6 analog voltage channels (0–1 V = 0–0.6 m³·m⁻³) |
| Cable | Shielded 9-conductor, standard 2 m with M12 IP68 connector |
| Probe Material | Polycarbonate (25.4 mm OD) and stainless steel |
| Dimensions/Weight | PR2/4: 750 mm L × 25.4 mm Ø, 0.6 kg |
| PR2/6 | 1350 mm L × 25.4 mm Ø, 0.9 kg |
| Compatible Readout | HH2 Moisture Meter (resolution: 1 mV |
| memory | 1100 readings |
| battery life | ~6500 readings) or DL6/DL2e Data Loggers |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DELTA1111 |
| Quotation | Available upon Request |
| Test Standards | ISO 6925, CFR 1630/1631, BS 6307, BS 4790, GB/T 20394–2013, GB/T 11049–2008, GB/T 14768–2015 |
| Sample Size | 230 mm × 230 mm (8 specimens per test) |
| Heating Source | Hot Metal Nut Method & Hexamethylenetetramine (Urotropine) Pellet Method |
| Ignition | Automatic Pulse Ignition |
| Timing Range | Flame Application Time: 0–99 s/min |
| Flame Application & Withdrawal Interval | 1.0–999.9 s (digital preset) |
| Afterflame Time | 1.0–999.9 s (digital readout) |
| Repetition Cycles | 1–9999 (digital preset) |
| Test Chamber Dimensions | 300 mm × 300 mm × 300 mm (W×D×H) |
| Ventilation Hood Volume | 2 m³ with Auto-Exhaust & Explosion-Proof Lighting |
| Exhaust Duct Diameter | Ø110 mm |
| Control System | PLC + 7-inch HMI Touchscreen |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Stainless Steel Hot Plate | 230 mm × 230 mm × 6.5 ±0.5 mm, central aperture Ø205 mm |
| Desiccant | Color-Indicating Silica Gel GPE0038 |
| Safety Features | Interlocked Protective Door, Black Interior Finish, Observation Window with Integrated LED Illumination |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | DD-## |
| Pricing | Available Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DEN-1 |
| Pricing | Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | DDC100 |
| Regulatory Status | FDA-cleared & CE-marked Class IIa Medical Device |
| Imaging Mode | Non-contact, polarized cross-polarized digital dermatoscopy |
| Resolution | Up to 10 MP native sensor output |
| Illumination | Uniform LED ring with adjustable intensity |
| Connectivity | USB 3.0 + HDMI real-time output |
| Software Compatibility | DermEngine, MoleMax Pro, and DICOM-compliant PACS systems |
| Power | Rechargeable lithium-ion battery (≥2.5 h continuous operation) |
| Certifications | ISO 13485, EN ISO 14971, IEC 62304 |
| Origin | New Zealand |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Designer Series |
| Instrument Type | High-Temperature Drying Oven |
| Temperature Range | +5°C to 260°C |
| Temperature Uniformity | ±2.5°C (at 105°C) |
| Temperature Stability | ±0.2°C |
| External Dimensions (W×D×H) | 550×530×550 mm |
| Internal Chamber Dimensions (W×D×H) | 400×360×420 mm |
| Power Supply | 230 V, 50 Hz |
| Safety Compliance | AS/NZS 3350, IEC 60335, CE Marked |
| Origin | Canada |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | DeskCAT |
| Quotation | Upon Request |
| Medical Device Registration Number | Not Applicable |
| Key | Temperature Range: –40 °C to +150 °C (standard) |
|---|---|
| Humidity Range | 30–98% RH (standard) |
| Temperature Resolution | 0.01 °C |
| Humidity Resolution | 0.1% RH |
| Temperature Uniformity | ±0.5 °C |
| Temperature Deviation | ≤±2 °C |
| Humidity Deviation | ≤±2.5% RH |
| Heating Rate | 2.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Control System | TEMI880 color LCD touchscreen programmable controller |
| Power Supply | 380 V ±5%, 50 Hz, 3P+N+G (customizable to 220 V) |
| Interior Material | SUS304 stainless steel |
| Exterior Material | SUS304 stainless steel or A3 steel with electrostatic powder coating |
| Origin | Poland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | DEWRanger DUO |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Dual-Ceramic Nanofilm Capacitive Sensor |
| Operating Temperature | −20 °C to +50 °C |
| Accuracy | ±2 °C |
| Repeatability | 0.5 °C |
| Dew Point Range | −100 °C to +20 °C |
| Flow Rate | 1–5 L/min |
| Gas Connection | 6 mm Push-to-Connect Fitting |
| Tubing | 6 mm PTFE |
| Max Operating Pressure | 3 MPa (Swagelok-compatible) |
| Display | Backlit LCD |
| Output | 4–20 mA Analog |
| Power Supply | Rechargeable Li-ion Battery |
| Enclosure | Yellow Polypropylene Housing |
| IP Rating | IP67 |
| Calibration Certificate | Traceable to NIST/PTB Standards |
| Dimensions (W×H×D) | 270 × 174 × 246 mm |
| Weight | 4.4 kg |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 61101 |
| Price Range | USD 11,000 – 13,800 (FOB) |
| Instrument Type | Online (Fixed-Installation) |
| Measurement Principle | Electrochemical Clark-type Polarographic Sensor |
| Measurement Range (Liquid) | 0.1 ppb – 200 ppm |
| Measurement Range (Gas) | 0.5 ppm(v/v) – 100% O₂ |
| Accuracy | ±1% of reading |
| Repeatability | ±0.05% of reading |
| Detection Limit | 2 ppb (liquid phase) |
| Power Supply | 85–230 VAC, 50/60 Hz |
| Power Consumption | ≤20 W |
| Operating Temperature | −5 °C to +50 °C |
| Enclosure Rating | Stainless Steel, IP65 / NEMA 4X |
| Weight | 3.0 kg |
| Dimensions | 230 mm × 180 mm × 75 mm |
| Display | Backlit LCD showing real-time DO concentration, temperature, timestamp, and membrane ID |
| Liquid Units | ppm, ppb, mg/L (resolution: 0.01 ppb) |
| Gas Units | % O₂, ppm(v/v), kPa (resolution: 0.01 ppm) |
| Membrane Kits | 82952, 82956, 82935 |
| Thermal Cut-off | Factory-set at +40 °C (adjustable via software) |
| Calibration | Single-point air calibration or direct zero/span calibration |
| Alarm Outputs | Dual configurable relay outputs (high/low or high/high |
| Communication | RS-232 and RS-485 (Modbus RTU protocol supported) |
| Sensor Compatibility | Dextens 51101 polarographic oxygen sensor |