Generic
Filter
Showing 151–180 of 1025 results
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | CBS-B |
| Price | USD 1,350 (FOB Shanghai) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | centrotherm Activator150 |
| Instrument Type | High-Vacuum Rapid Thermal Annealing Furnace |
| Sample Size | 150 mm (6-inch) wafers |
| Operating Atmosphere | Ambient pressure or controlled vacuum/pressure |
| Maximum Ramp Rate | 150 K/s |
| Maximum Cool-down Rate | 150 K/s |
| Temperature Accuracy | ±1 °C |
| Temperature Uniformity | ≥95% across wafer surface |
| Max Process Temperature | 1850 °C |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Centrotherm c.RAPID 150 / RTP 150 |
| Instrument Type | High-Vacuum Rapid Thermal Annealing Furnace |
| Sample Size | 6-inch wafer or substrate |
| Operating Atmosphere | Ambient pressure or controlled vacuum (1–50 mbar) |
| Max. Ramp Rate | 150 K/s |
| Max. Cool-down Rate | 150 K/s |
| Temperature Accuracy | ±1 °C |
| Temperature Uniformity | ±0.5 °C across 6″ wafer |
| Max. Process Temperature | 1150 °C (unlimited dwell at ≤750 °C) |
| Heating System | 24 independently PWM-controlled lamp arrays |
| Cooling Water Requirement | 20 L/min |
| Exhaust Flow | 250 m³/h |
| Substrate Compatibility | Si, GaAs, SiC, GaN, Sapphire, graphite carriers |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Z61GP |
| Price Range | USD 13,500 – 40,500 |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | LM-8 |
| Pricing | Available Upon Request |
| Sample Size | 100 × 100 mm |
| Test Stations | 2–8 simultaneous samples |
| Turntable Center-to-Sample Center Distance | 195 mm |
| Rated Turntable Speed | 300 ± 10% rpm |
| Eccentricity | e = 22.5 mm |
| Fixture Internal Diameter | Ø83 mm |
| Fixture Internal Height | 25.5 mm |
| Effective Abraded Area per Sample | ≈54 mm² |
| Motor Power | 1.5 kW |
| Power Supply | 380 V ± 10%, 50 Hz ± 10%, 3-phase 4-wire |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | CheckitDirect |
| Pricing | Upon Request |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | CHEETAH HP100 |
| Price Range | USD 42,000 – 56,000 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative HPLC System |
| Flow Rate Range | 0.1–100.0 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ±1% |
| Maximum Pressure | 20 MPa |
| Wavelength Range | 200–400 nm / 800 nm (dual-channel) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±1 nm |
| Baseline Noise | ≤3 × 10⁻⁴ AU |
| Data Acquisition Frequency | 3 Hz |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | CHEETAH MP100 |
| Price Range | USD 14,000–28,000 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative HPLC |
| Flow Rate Range | 1–100 mL/min |
| Flow Accuracy | ±2% |
| Flow Precision (RSD) | ±2% |
| Maximum Operating Pressure | 200 psi |
| Wavelength Range | 200–400 nm (standard detector) |
| Wavelength Accuracy | ±1 nm |
| Baseline Noise | 3 × 10⁻⁴ AU |
| Data Acquisition Frequency | 3 Hz |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | DHX |
| Pricing | Upon Request |
| Tidal Volume Range | 1–50 mL / 1–150 mL / 1–300 mL / 1–500 mL (selectable) |
| Respiratory Rate | 1–199 breaths/min |
| I | E Ratio Options: 1:1, 1:2, 1:3, 2:1 |
| Power Supply | 220 V ±10%, 50 Hz |
| Dimensions (W×H×D) | 400 × 140 × 280 mm |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JP-2E |
| Pricing | Upon Request |
| Polarographic Sensitivity | <5×10⁻⁸ mol/L (Cd²⁺, Linear Sweep Voltammetry) |
| Polarographic Peak Resolution | <32 mV |
| Anti-Interference Capability (Pre-reduced Species) | >20,000:1 |
| Repeatability Error | <0.4% |
| Current Range | 15 nA–400 µA F.S., 23 programmable decades |
| Polarization Potential Range | ±4000 mV, minimum step: 2 mV |
| Scan Rate | 50–1600 mV/s |
| Scan Amplitude | 50–1600 mV |
| Scan Period | 2–22 s |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Weight | 15 kg |
| Interface | USB 2.0 for PC connectivity |
| Software Modes | Linear Sweep Voltammetry, Stripping Voltammetry (Anodic/Cathodic), Cyclic Voltammetry (Anodic/Cathodic), First/Second Derivative Voltammetry |
| Quantitative Methods | Calibration Curve (Linear & Quadratic Regression), Standard Addition, Standard Comparison |
| Electrode Compatibility | Glassy Carbon Electrode (GCE) interface with full Dropping Mercury Electrode (DME) functional equivalence |
| Data Export | Native CSV/Excel-compatible output, curve annotation, overlay, and statistical post-processing |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CYW-600S |
| Price | USD 3,500 (FOB) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CI-203 |
| Pricing | Upon Request |
| Origin | Taiwan |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | PH30P |
| Price Range | USD 140–420 |
| pH Range | 0.00–13.00 |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 + 1 LSD |
| Temperature Range | 0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Electrode | Replaceable CS1930P Piercing-Type pH Sensor (316L stainless steel shaft) |
| Display | Backlit 20×30 mm multi-line LCD |
| Battery | 1×1.5 V AAA (>500 h life) |
| Auto-off | 5 min |
| Dimensions | 185×40×48 mm |
| Weight | 95 g |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | C76688 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CLYC |
| Price Range | USD 14,000 – 42,000 |
| Detection Limit | Bq/L |
| Stability | ±5% (over 24 h, 23°C) |
| Energy Resolution | <5.0% FWHM at 662 keV (¹³⁷Cs) |
| Origin | Hubei, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | CMI830 |
| Pricing | Upon Request |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | CMI830 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Easy-Load |
| Pricing | Available Upon Request |
| Flow Rate | 0.01–1700 mL/min (with L/S 24 tubing) |
| Speed Range | 1.6–600 rpm |
| Speed Resolution | 0.1 rpm (≤100 rpm), 1 rpm (>100 rpm) |
| Motor | 1/10 HP, brushless DC with soft-start and back-EMF regulation |
| Accuracy | ±2% of set speed |
| Enclosure Rating | IP23 |
| Power Supply | 115 VAC (NEMA 5-15P) or 230 VAC (IEC 320 C14) |
| Cable Length | 1.8 m |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | COM3400W |
| Pricing | Available Upon Request |
| Temperature Range | -20 °C to +130 °C |
|---|---|
| Humidity Range | 40–98% RH |
| Temperature Uniformity | ±2 °C (unloaded) |
| Temperature Fluctuation | ±0.5 °C (unloaded) |
| Humidity Fluctuation | ±2% RH |
| Heating Rate | -20 °C to +120 °C ≤ 60 min |
| Cooling Rate | Ambient to -20 °C ≤ 45 min (unloaded) |
| Vibration Force (Sine) | 2.94 kN (300 kgf) |
| Frequency Range | 5–2000 Hz |
| Max Acceleration | 980 m/s² (100 g) |
| Max Velocity | 1.1 m/s |
| Max Displacement | 25 mm p-p |
| Moving Mass | 2.7 kg |
| Payload Capacity | 120 kg |
| Table Diameter | 150 mm |
| Vibration Axis | Vertical (Z-axis) |
| Test Duration Setting | 0–999 h |
| Compliance | GB/T 2423.1, GB/T 2423.3, GB/T 2423.4, IEC 60068-2-1 (Cold), IEC 60068-2-3 (Damp Heat), IEC 60068-2-30 (Cyclic Damp Heat) |
| Key | Temperature Range: −60 °C to +150 °C |
|---|---|
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Deviation | ≤ ±2 °C |
| Ramp Rate | 0.7–1.0 °C/min |
| Time Setting Range | 0–9999 h |
| Refrigeration System | Two-stage cascade mechanical compression |
| Refrigerant | HFC-R404A / HFC-R23 |
| Cooling Method | Water-cooled |
| Control Interface | Color touchscreen + PLC (OYO or TIME) |
| Construction | A3 steel exterior with powder coating |
| Viewing Window | Multi-layer tempered glass with conductive film |
| Cable Port | Ø50 mm (left side) |
| Humidification | Built-in water tank with booster pump |
| Air Circulation | Forced convection via extended-shaft stainless steel centrifugal blower (bottom inlet / top outlet) |
| Sealing | Dual-layer high-tensile high-temp silicone gasket |
| Vibration Integration | Optional electrodynamic or servo-hydraulic shaker system (user-specified) |
| Key | Temperature Range: -20°C to +130°C |
|---|---|
| Humidity Range | 40–98% RH |
| Temperature Uniformity | ±2°C (unloaded) |
| Temperature Stability | ±0.5°C (unloaded) |
| Humidity Stability | ±2% RH |
| Temperature Deviation | ≤±2°C |
| Humidity Deviation | ≤±2°C |
| Heating Rate | -20°C to +120°C ≤60 min |
| Cooling Rate | Ambient to -20°C ≤45 min (unloaded) |
| Time Setting Range | 0–999 h |
| Vibration Frequency Range | 5–2000 Hz |
| Max Acceleration | 980 m/s² (100 g) |
| Max Velocity | 1.1 m/s |
| Max Displacement | 25 mm p-p |
| Dynamic Load Capacity | 120 kg |
| Moving Mass | 2.7 kg |
| Table Diameter | 150 mm |
| Vibration Axis | Vertical (Z-axis) |
| Excitation Force | 300 kN (300 kgf) |
| Noise Level | Low |
| Power Efficiency | 60% reduction vs. conventional designs |
| Key | Temperature Range: −70 °C to +150 °C |
|---|---|
| Humidity Range | 20–98% RH |
| Temp. Uniformity | ≤ ±2.0 °C |
| Temp. Stability | ≤ ±0.5 °C |
| Humidity Stability | +2/−3% RH |
| Cooling Rate (unloaded) | 0.7–1.0 °C/min |
| Heating Rate (unloaded) | 1.0–3.0 °C/min |
| Vibration Type | Electromagnetic Shaker |
| Frequency Range | 2–500 Hz |
| Displacement Amplitude | 0–5 mm |
| Acceleration Range | 0–20 g |
| Compliance | GB/T 2423.1, GB/T 2423.2, GB/T 2423.3, GB/T 2423.10, GB/T 2423.48, GB/T 2423.49, GB 10586, GB 10589, GB 10592, GB 11158, GB/T 5170.2, GB/T 5170.5 |
| Key Features | Platform Size: 1000 × 1000 mm |
|---|---|
| Chamber Dimensions (W×D×H) | 1100 × 1200 × 650 mm |
| Weight | ~350 kg |
| Power Supply | AC 220 V, Single-Phase, 15 A |
| Drive Mechanism | Motor-Cam Actuation |
| Max. Amplitude | 25.4 mm (1 in) |
| Rotational Speed Range | 120–300 rpm |
| Frequency Range | 2.00–5.00 Hz |
| Test Duration | Up to 80 min per cycle |
| Cycle Count | Up to 14,500 cycles per run |
| Operating Ambient | 23 °C ± 5 °C, RH < 80 % (non-condensing) |
| Sound Pressure Level | <74 dB(A) at 5 Hz |
| 台面材质 translated as Top Plate Material | 19-mm (3/4″) Structural Plywood |
| Display | Dual independent digital displays for simultaneous frequency and rpm readout |
| Control Modes | Timer-based and counter-based operation |
| Vibration Modes | Vertical-only, Horizontal-only, Dual-axis synchronous, Dual-axis alternating |
| Compliance | ISTA 3A, ISTA 3B, ASTM D999, ASTM D4169, ASTM D3580 |
| Key Specifications | Temperature Range: -40°C to +130°C |
|---|---|
| Humidity Range | 40–98% RH |
| Temp. Uniformity | ±2°C (unloaded) |
| Temp. Stability | ±0.5°C (unloaded) |
| Humidity Stability | ±2% RH |
| Heating Rate | ≤60 min (-20°C → +120°C) |
| Cooling Rate | ≤45 min (ambient → -20°C, unloaded) |
| Vibration Force | 2.94 kN (300 kgf) |
| Frequency Range | 5–2000 Hz |
| Max. Acceleration | 980 m/s² (100 g) |
| Max. Velocity | 1.1 m/s |
| Max. Displacement | 25 mm p-p |
| Table Diameter | 150 mm |
| Vibration Axis | Vertical (Z-axis only) |
| Payload Capacity | 120 kg |
| Control Timer | 0–999 h |
| Compliance Standards | ASTM D999, ASTM D3580, ISTA 2A/3A, EN 60068-2-6 & -2-78, ANSI/UL 60950, ISO 16750-3 |
| Temperature Range | -20 °C to 150 °C |
|---|---|
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Deviation | ≤ ±2 °C |
| Ramp Rate | 0.7–1.0 °C/min |
| Test Duration Setting | 0–9999 hours |
| Sinusoidal Force Capacity | 2.94 kN (300 kgf) |
| Frequency Range | 5–500 Hz |
| Maximum Acceleration | 980 m/s² (100 g) |
| Maximum Velocity | 1.1 m/s |
| Maximum Displacement | 25 mm peak-to-peak |
| Moving Mass | 2.7 kg |
| Maximum Payload | 120 kg |
| Table Surface Dimensions | 150 mm × 150 mm |
| Vibration Axis | Vertical (Z-axis only) |
| Power Supply | AC 380 V ±10%, 50 Hz, 3-phase 5-wire |
| Key | Temperature Range: -70°C to +150°C |
|---|---|
| Humidity Range | 5–98% RH (standard: 20–98% RH) |
| Temperature Resolution & Uniformity | ±0.1°C / ±2.0°C |
| Humidity Resolution & Uniformity | ±0.1% RH / ±3.0% RH |
| Temperature Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.5% RH |
| Heating Rate | ~4.0°C/min |
| Cooling Rate | ~1.0°C/min |
| Construction | Interior & Exterior – SUS304 stainless steel |
| Insulation | High-density polyurethane foam (chlorinated ethyl carbamate-based, high-temp resistant) |
| Refrigeration System | Air-cooled |
| Safety Protections | Fuseless circuit breaker, compressor overload protection, refrigerant HP/LP cut-off, over-temperature/over-humidity safeguards, fuse, fault alarm system, low-water warning |
| Controller | Touchscreen LCD with bilingual (EN/CN) interface, 100 programmable profiles × 1000 segments × 999 cycles, max segment duration: 99h 59m, screen lock function, real-time curve display, RS-232/RS-485 interface for PC-based programming and remote monitoring |
| Structural Features | A3 carbon steel outer shell with powder coating, SUS304 mirror-finish inner chamber, double-layer high-tensile silicone gasket seal, anti-rebound door handle, multi-layer laminated tempered glass viewport with conductive ITO film, Ø50 mm cable port (left side), removable vibration table mounted on precision linear rails, low-noise Sanyo Denki blower with multi-wing centrifugal impeller, epoxy-silicone hybrid sealing between shaker table and chamber base |
| Key | Temperature Range Options: -20°C to 150°C |
|---|---|
| Humidity Range | 20–98% RH |
| Temperature Uniformity | ≤ ±0.5°C |
| Temperature Stability | ≤ ±2°C |
| Humidity Deviation | +2 / –3% RH |
| Heating Rate (–20°C → 100°C) | ~35 min |
| Cooling Rate (25°C → –40°C) | ~50 min |
| Vibration System | Electrodynamic Shaker (OK-ES), Sinusoidal/Random/Shock Control, Vertical Magnesium Alloy Table (VT0404), Accelerometer (BW), DA-6 Power Amplifier, Excitation Supply, RS232 & USB Data Interface |
| Optional Add-ons | LN2V Liquid Nitrogen Rapid Cooling Unit, LHC Low-Humidity Sensor with Regenerative Desiccant Dryer |
| Compliance | Designed for IEC 60068-2, MIL-STD-810, ASTM D4332, ISO 16750-4, and GLP/GMP-aligned test documentation workflows |
| Key | Temperature Range: -20°C to +130°C |
|---|---|
| Temperature Uniformity | ±2°C (unloaded) |
| Temperature Fluctuation | ±0.5°C (unloaded) |
| Humidity Range | 40–98% RH |
| Humidity Fluctuation | ±2% RH |
| Temperature Deviation | ≤±2°C |
| Humidity Deviation | ≤±2% RH |
| Heating Rate | -20°C to +120°C ≤ 60 min (unloaded) |
| Cooling Rate | Ambient to -20°C ≤ 45 min (unloaded) |
| Vibration Force (Sine) | 2.94 kN (300 kgf) |
| Frequency Range | 5–2000 Hz |
| Max Acceleration | 980 m/s² (100 g) |
| Max Velocity | 1.1 m/s |
| Max Displacement | 25 mm p-p |
| Moving Mass | 2.7 kg |
| Payload Capacity | 120 kg |
| Table Diameter | 150 mm |
| Vibration Axis | Vertical (Z-axis) |
| Timer Range | 0–999 h |
| Compliance | GB/T 2423.1, GB/T 2423.3, GB/T 2423.4, IEC 60068-2-1, IEC 60068-2-3, IEC 60068-2-30 |