| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HAIDA HD-D014 Liquid Rewet Tester |
| Pricing | Upon Request |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HAIDA HD-D018 Nonwoven Tensile Strength Tester |
| Pricing | Upon Request |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HAIDA HD-D020 Hydrostatic Pressure Tester |
| Pricing | Upon Request |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HAIDA HD-D021 Air Permeability Tester |
| Pricing | Available Upon Request |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HD-D022 Flushability Tester |
| Pricing | Upon Request |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HAIDA HD-D113-2 Luggage Mileage Life Testing Machine |
| Price | Upon Request |
| Test Speed (Method B) | 0.1–3 km/h (adjustable) |
| Intermittent Cycle | 10 min pause per 2 km |
| Bump Plate Material | Aluminum Alloy |
| Bump Plate Hardness | HB (40 ± 5) |
| Bump Plate Length | (300 ± 2) mm |
| Conveyor Belt Circumference | (5500 ± 25) mm |
| Conveyor Belt Width | (700 ± 5) mm |
| Hook Height Adjustment Range | 450–700 mm (from conveyor surface to hook center) |
| Control System | PLC-based |
| Display Interface | Touchscreen HMI |
| Data Export | USB port |
| Sample Size Compatibility | Suitcases: 16–33 inches |
| Travel Bags | 20–50 L |
| Overall Dimensions (L×W×H) | Approx. 2700 × 1350 × 1800 mm |
| Weight | Approx. 750 kg |
| Power Supply | 1-phase AC 220 V |
| Rated Power | ~950 W |
| Compliant Standard | QB/T 2920–2018 (Method B) |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HAIDA HD-D114-2 Luggage Oscillatory Impact Tester |
| Test Speed | 10–30 cycles per minute (c.p.m.) |
| Control System | PLC-based with Touchscreen HMI |
| Display | 7-inch TFT color touchscreen |
| Data Output | USB flash drive export (CSV/Excel-compatible) |
| Load Capacity | ≤50 kg |
| Stroke Adjustment Range | 50–150 mm (digitally settable via touchscreen) |
| Oscillation Mechanism | Precision-calibrated helical compression spring (17.54 ± 0.88 N/mm) |
| Impact Mass | 8.1 ± 0.2 kg |
| Sample Dimensions (Max) | 700 × 700 × 1200 mm (L×W×H) |
| Overall Dimensions | 1300 × 1200 × 3300 mm (L×W×H) |
| Weight | ~390 kg |
| Air Supply Requirement | ≥0.6 MPa |
| Power Supply | 1-phase, 220 V / 50 Hz |
| Power Consumption | ~200 W |
| Compliant Standard | QB/T 2922–2018 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HAIDA HD-D126 Zipper Reciprocating Durability Tester |
| Pricing | Upon Request |
| Reciprocating Stroke | 75 mm |
| Cycle Rate | 30 cycles/min |
| Horizontal Clamp Width | 25 mm |
| Closed-Zipper Angle α | 60° |
| Open-Zipper Angle α | 30° |
| Fixed Clamp Orientation Angle β | 10° |
| Counter Display | LCD, Max Count 99,999,999 |
| Dimensions (L×W×H) | 660 × 325 × 573 mm |
| Weight | 61.5 kg |
| Power Supply | 1-phase 220 V, 50 Hz |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HD-D128-1 |
| Pricing | Upon Request |
| Brand | Haida International |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Environmental Test Chamber |
| Model | HD-E702-1000B40/60 |
| Temperature Range | −60 °C to +150 °C |
| Temperature Uniformity | ≤2 °C |
| Temperature Deviation | ±0.5 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 20–98% RH |
| Humidity Deviation | ±2% RH |
| Humidity Fluctuation | ±2% RH |
| Humidity Uniformity | ±3% RH |
| Heating Rate | ≥3 °C/min (−60 °C to +150 °C, average) |
| Cooling Rate | ≥1 °C/min (+150 °C to −60 °C, average) |
| Internal Dimensions | 1000 mm × 1000 mm × 1000 mm (W×H×D) |
| External Dimensions | 1540 mm × 2110 mm × 1380 mm (W×H×D) |
| Net Weight | 405–435 kg |
| Power Supply | 3-phase, 380 V AC |
| Rated Power | 14–16 kW |
| Refrigerant | R404A / R23 (eco-friendly, non-ozone-depleting) |
| Compressor | Dual hermetic scroll compressors (Tecumseh/France Tecumseh equivalent) |
| Control System | Taiwan UYI 7-inch color touchscreen PID controller with 1200-segment programmability |
| Data Logging | Built-in 2GB SD card |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HD-E702-1000K Deep Blue |
| Instrument Type | Benchtop |
| Temperature Range | −60 °C to +150 °C |
| Humidity Range | 20 %RH to 98 %RH |
| Temperature Deviation | ≤ ±0.5 °C |
| Temperature Uniformity | ≤ 2 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Deviation | ±2 %RH |
| Humidity Uniformity | ±3 %RH |
| Humidity Fluctuation | ±2 %RH |
| Heating Rate | ≥ 3 °C/min (−60 °C → +150 °C, average) |
| Cooling Rate | ≥ 1 °C/min (+150 °C → −60 °C, average) |
| Internal Dimensions | 1000 mm × 1000 mm × 1000 mm (W×H×D) |
| External Dimensions | 1280 mm × 2080 mm × 1900 mm (W×H×D) |
| Net Weight | 458 kg |
| Power Supply | 3-phase, 380 V AC |
| Rated Power | 16 kW |
| Brand | Haida International |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Environmental Test Chamber |
| Temperature Range | −60 °C to +150 °C |
| Temperature Uniformity | ≤2 °C |
| Temperature Deviation | ±0.5 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 20–98% RH |
| Humidity Deviation | ±2% RH |
| Humidity Fluctuation | ±2% RH |
| Humidity Uniformity | ±3% RH |
| Heating Rate (−60 °C → +150 °C) | ≥3 °C/min (average) |
| Cooling Rate (+150 °C → −60 °C) | ≥1 °C/min (average) |
| Internal Dimensions | 1000 mm × 1000 mm × 1000 mm (W×H×D) |
| External Dimensions | 1280 mm × 2080 mm × 1900 mm (W×H×D) |
| Net Weight | 458 kg |
| Power Supply | 3-phase, 380 V AC |
| Rated Power | 16 kW |
| Refrigeration System | Dual-stage mechanical refrigeration with two imported Tecumseh (France) hermetic compressors (3 HP each), R404a/R23 eco-friendly refrigerants |
| Control System | Taiwan UYI 7-inch color touchscreen programmable controller with PID + Fuzzy logic algorithm, 1200-segment capacity, 120 program groups, data logging via SD card (2 GB standard), USB export, RS-232/485 interface |
| Compliance | GB/T 2423.1–2008, GB/T 2423.2–2008, GB/T 2423.3–2008 (IEC 60068-2-3), GB/T 2423.22–2008, GJB 150.3A–2009, GJB 150.4A–2009, GB/T 10589–2008, GB/T 2424.5–2006 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HD-E702-1000K40/60 Programmable Temperature and Humidity Environmental Test Chamber |
| Instrument Type | Benchtop (Freestanding) |
| Temperature Range | −60 °C to +150 °C |
| Temperature Uniformity | ≤2 °C |
| Temperature Deviation | ±0.5 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 20–98% RH |
| Humidity Deviation | ±2% RH |
| Humidity Fluctuation | ±2% RH |
| Humidity Uniformity | ±3% RH |
| Heating Rate | ≥3 °C/min (−60 °C → +150 °C, average) |
| Cooling Rate | ≥1 °C/min (150 °C → −60 °C, average) |
| Internal Chamber Dimensions | 1000 mm × 1000 mm × 1000 mm (W×H×D) |
| External Dimensions | 1280 mm × 2080 mm × 1900 mm (W×H×D) |
| Net Weight | 458 kg |
| Power Supply | 3-phase, 380 V AC |
| Rated Power | 16 kW |
| Refrigerant | R404A / R23 (eco-friendly) |
| Controller | Taiwan UYI 7-inch color touchscreen PID programmable controller with USB data export, RS232/RS485 interface, and SD card logging |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HD-E702-1000K60 |
| Instrument Type | Benchtop |
| Temperature Range | −60 °C to +150 °C |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Fluctuation | ±1 °C (high-temp), ±2 °C (low-temp) |
| Humidity Range | 20–98% RH |
| Humidity Uniformity | ±3% RH |
| Humidity Fluctuation | ±3% RH |
| Heating Rate | 1.0–3.0 °C/min |
| Internal Chamber Dimensions | 1000 mm × 1000 mm × 1000 mm (W×H×D) |
| Control Resolution | 0.01 °C / 0.1% RH |
| Compliance | GB/T 2423.1–2008, GB/T 2423.2–2008, GB/T 2423.3–2008, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-3, GJB 150.3A–2009, GJB 150.4A–2009 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HD-E702-100B60 |
| Instrument Type | Benchtop Chamber |
| Temperature Range | −60 °C to +150 °C |
| Temperature Uniformity | ≤2 °C |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Resolution | 0.01 °C |
| Humidity Range | 20–98% RH |
| Humidity Uniformity | ±3% RH |
| Humidity Fluctuation | ±2% RH |
| Humidity Resolution | 0.1% RH |
| Humidity Deviation | ±2% RH |
| Heating Rate | ≥3 °C/min (−60 °C to +150 °C, average) |
| Cooling Rate | ≥1 °C/min (+150 °C to −60 °C, average) |
| Internal Dimensions | 400 mm × 500 mm × 500 mm (W×H×D) |
| External Dimensions | 940 mm × 1400 mm × 1080 mm (W×H×D) |
| Net Weight | 163 kg |
| Power Supply | Single-phase 220 V AC, 11 A, 6.5 kW |
| Refrigeration System | Dual-stage mechanical refrigeration with R404A/R23 blend |
| Controller | 7-inch TFT color touchscreen with programmable PID logic, 120 programs / 1200 segments, USB data export, RS232/RS485 interface |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Environmental Test Chamber |
| Temperature Range | −60 °C to +150 °C |
| Temperature Uniformity | ≤2 °C |
| Temperature Deviation | ±0.5 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 20–98% RH |
| Humidity Deviation | ±2% RH |
| Humidity Fluctuation | ±2% RH |
| Humidity Uniformity | ±3% RH |
| Heating Rate | ≥3 °C/min (−60 °C to +150 °C, average) |
| Cooling Rate | ≥1 °C/min (+150 °C to −60 °C, average) |
| Internal Dimensions | 400 mm × 500 mm × 500 mm (W×H×D) |
| Net Volume | 100 L |
| Refrigerant | R404a / R23 (dual-circuit system) |
| Control System | Taiwan UYI 7-inch color touchscreen PID controller with 1200-segment programmability |
| Compliance | GB/T 2423.1–2008, GB/T 2423.2–2008, GB/T 2423.3–2008 (IEC 60068-2-3), GJB 150.3A–2009, GJB 150.4A–2009 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HD-E702-150K40/60 |
| Instrument Type | Benchtop Environmental Chamber |
| Temperature Range | −60 °C to +150 °C |
| Temperature Uniformity | ≤2 °C |
| Temperature Deviation | ±0.5 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 20–98% RH |
| Humidity Deviation | ±3% RH |
| Humidity Fluctuation | ±2% RH |
| Heating Rate | ≥3 °C/min (−60 °C → +150 °C, average) |
| Cooling Rate | ≥1 °C/min (+150 °C → −60 °C, average) |
| Interior Dimensions | 500 mm × 600 mm × 500 mm (W×H×D) |
| Net Weight | 208 kg |
| Power Supply | Single-phase 220 V AC, 11 A, 7 kW |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HD-E702-225B60 |
| Instrument Type | Benchtop Environmental Chamber |
| Temperature Range | −60 °C to +150 °C |
| Temperature Uniformity | ≤2 °C |
| Temperature Deviation | ±0.5 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 20–98% RH |
| Humidity Deviation | ±2% RH |
| Humidity Fluctuation | ±2% RH |
| Humidity Uniformity | ±3% RH |
| Heating Rate (−60 °C → +150 °C) | ≥3 °C/min (average) |
| Cooling Rate (+150 °C → −60 °C) | ≥1 °C/min (average) |
| Internal Dimensions (W×H×D) | 500 mm × 750 mm × 600 mm |
| Net Weight | 240 kg |
| Power Supply | 3-phase, 380 V AC |
| Rated Power | 9 kW |
| Brand | Haida International |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Environmental Test Chamber |
| Model | HD-E702-225K40/60 |
| Temperature Range | −60 °C to +150 °C |
| Temperature Uniformity | ≤2 °C |
| Temperature Deviation | ±0.5 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 20–98% RH |
| Humidity Deviation | ±2% RH |
| Humidity Fluctuation | ±2% RH |
| Humidity Uniformity | ±3% RH |
| Heating Rate | ≥3 °C/min (−60 °C to +150 °C, average) |
| Cooling Rate | ≥1 °C/min (150 °C to −60 °C, average) |
| Internal Dimensions | 500 mm × 750 mm × 600 mm (W×H×D) |
| External Dimensions | 780 mm × 1680 mm × 1520 mm (W×H×D) |
| Net Weight | 255 kg |
| Power Supply | 3-phase, 380 V AC |
| Rated Power | 9 kW |
| Refrigerant | R404a / R23 (dual-circuit system) |
| Control System | 7-inch color touchscreen controller with PID + Fuzzy logic algorithm |
| Data Logging | Built-in 2GB SD card, USB export, RS232/RS485 interface |
| Compliance | GB/T 2423.1–2008, GB/T 2423.2–2008, GB/T 2423.3–2008, GB/T 2423.22–2008, GJB 150.3A–2009, GJB 150.4A–2009 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Environmental Chamber |
| Model | HD-E702-225K40/60 |
| Temperature Range | −60 °C to +150 °C |
| Temperature Uniformity | ≤2 °C |
| Temperature Deviation | ±0.5 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 20–98% RH |
| Humidity Deviation | ±2% RH |
| Humidity Fluctuation | ±2% RH |
| Humidity Uniformity | ±3% RH |
| Heating Rate | ≥3 °C/min (−60 °C to +150 °C, average) |
| Cooling Rate | ≥1 °C/min (+150 °C to −60 °C, average) |
| Internal Dimensions (W×H×D) | 500 mm × 750 mm × 600 mm |
| External Dimensions (W×H×D) | 780 mm × 1680 mm × 1520 mm |
| Net Weight | 255 kg |
| Power Supply | 3-phase, 380 V AC |
| Rated Power | 9 kW |
| Rated Current | 14 A |
| Refrigerant | R404a / R23 (dual-circuit) |
| Compressor | Dual 3 HP hermetic compressors (Tecumseh/France) |
| Control System | 7-inch color touchscreen PID controller with programmable logic, 120 programs × 99 segments (1200 total segments), USB data export, RS232/RS485 interface, SD card logging (2 GB standard) |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Model | HD-E703-100 |
| High-Temperature Range | RT to 170 °C |
| Low-Temperature Range | −75 °C to RT |
| Thermal Shock Range | 60–150 °C (hot) / −10 to −65 °C (cold) |
| Temperature Stability | ±0.3 °C, ±2% RH |
| Heating Rate | 2 °C/min |
| Cooling Rate | 0.5–1.2 °C/min |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HAIDA HD-E703-50 Programmable Three-Zone Thermal Shock Test Chamber |
| High-Temperature Range | RT to 170 °C |
| Low-Temperature Range | −75 °C to RT |
| Thermal Shock Range | 60 °C to 150 °C / 170 °C (high) |
| Temperature Stability | ±2 °C |
| Heating Rate | 5–10 °C/min |
| Cooling Rate | 1–2 °C/min |
| Brand | Haida International |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Haida HD-E704 UV-Exposure & Thermal Aging Test Chamber |
| Internal Chamber Dimensions | 500 × 500 × 600 mm (L×W×H) |
| Temperature Range | Ambient to 200 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Control Accuracy | ±3 °C |
| Temperature Uniformity | ±2 °C at 100 °C |
| Test Duration Range | 0–999 h (power-fail memory function) |
| Turntable Diameter | ∅350 mm |
| Turntable Speed | 3 ±1 rpm |
| UV Source | 300 W UV lamp (E27 base) |
| Heating Method | Forced-air convection |
| Interior Material | SUS304 brushed stainless steel |
| Exterior Finish | High-durability baked enamel coating |
| Safety Protection | Short-circuit protection circuitry |
| Specimen Size Requirement | ≥30 × 10 mm |
| Overall Dimensions | Approx. 930 × 650 × 1350 mm (L×W×H) |
| Weight | Approx. 150 kg |
| Power Supply | 1-phase AC 220 V |
| Total Power Consumption | ~2.8 kW |
| Compliant Standards | HG/T 3689–2014 (Sections 3.1, 4.1, 6.1, 7.1) |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HAIDA HD-E705 Walk-in Temperature and Humidity Environmental Test Chamber |
| Temperature Range | -70°C to +80°C (three standard configurations: T-model: -20°C to +80°C |
| F-model | -40°C to +80°C |
| S-model | -70°C to +80°C) |
| Humidity Range | 20–98% RH |
| Temperature Deviation | ±1.5°C |
| Temperature Uniformity | ≤2°C |
| Temperature Fluctuation | ±0.5°C |
| Humidity Deviation | ±2% RH |
| Humidity Uniformity | ≤3% RH |
| Humidity Fluctuation | ±2% RH |
| Ramp Rates (empty load) | +25°C → +80°C ≤35 min |
| Internal Chamber Volume Options | 4 m³, 8 m³, 10 m³, 15 m³, 20 m³, 25 m³, 30 m³, 40 m³ (custom volumes available) |
| Construction | Modular prefabricated panels with SUS304 stainless steel interior and color-coated galvanized steel exterior |
| Insulation | 100 mm rigid polyurethane foam (thermal conductivity ≤0.022 W/m·K) |
| Door | Dual-opening, 1500 mm × 2200 mm clear aperture, reinforced hinges, Japanese locking mechanism with anti-jamming function |
| Viewing Windows | Two 300 mm × 450 mm conductive anti-fog tempered glass windows with ITO coating |
| Test Port | One Φ100 mm port (position customizable) |
| Control System | TEMI2700 7.5″ color TFT touchscreen controller (SAMWON, Korea), supporting multi-segment programmable profiles (max 120 programs, 1200 segments), RS-232/RS-485 interface, SD card data logging (2 GB standard, upgradable to 4 GB), Ethernet-ready for remote monitoring and synchronized multi-chamber control |
| Safety Systems | Dual-stage overtemperature protection, compressor high/low pressure cut-off, PT100-based real-time thermal monitoring, leak-tested refrigerant circuit (22 bar test pressure), R404A/R23 eco-friendly refrigerant blend |
| Compliance | GB/T 2423.1–2008 (Cold), GB/T 2423.2–2008 (Heat), GB/T 2423.3–2008 / IEC 60068-2-3 (Steady-state Damp Heat), GB/T 2423.4–2008 / IEC 60068-2-30 (Cyclic Damp Heat), GJB 150.3A–2009 / 150.4A–2009 / 150.9A–2009, GB/T 10586–2006, GB/T 10589–2008, GB/T 5170.18–2005 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HAIDA HD-E710 Rain Test Chamber |
| Temperature Range | 15–40 °C |
| Rainfall Intensity | 1.7 mm/min |
| Water Droplet Diameter | 0.5–4.5 mm (nozzle orifice: φ0.6 mm and φ0.33 mm) |
| Wind Speed Range | 5–20 m/s (adjustable |
| nominal test condition | 18 m/s at 45° droplet deflection) |
| Test Duration | 1–999,999 min (programmable) |
| Internal Chamber Dimensions | 2500 × 1500 × 1800 mm (D×W×H) |
| Turntable Diameter | φ1000 mm |
| Turntable Load Capacity | 100 kg |
| Turntable Speed | 1–3 rpm (adjustable) |
| Drip Area | 800 × 800 mm |
| Nozzle Spacing | 20 mm |
| Drip Height | 1000 mm |
| Airflow Cross-Section | 1000 × 1000 mm |
| Control System | Teelong PLC-based touchscreen controller with RS232/USB interface |
| Compliance | MIL-STD-810G Method 506.5 Procedure I, GJB150.8A-2009 Program I |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HAIDA HD-E711 Xenon Arc Weathering Test Chamber |
| Xenon Lamp Power | 5.4 kW (3 lamps, 1200 h service life) |
| Irradiance Control Range | 0.3–1.2 W/m² at 340 nm |
| Temperature Range | 0–80 °C |
| Humidity Range | 20–98 % RH (non-irradiated), 30–98 % RH (light cycle) |
| Black Panel Temperature | 85 ± 3 °C |
| Chamber Dimensions (W×D×H) | ≥600 × 500 × 750 mm |
| Spectral Range | 290–800 nm |
| Water Spray Pressure | 0.12–0.15 kPa |
| Spray Nozzle Diameter | Ø0.8 mm |
| Rainfall Duration | 1–9999 min (continuous or interval mode) |
| Spray Cycle | On/Off time adjustable from 0 to 99 h 59 min each |
| Sample-to-Arc Distance | 350–380 mm |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HAIDA HD-E711 Xenon Arc Weathering Test Chamber |
| Xenon Lamp Power | 7.5 kW (3 × 2.5 kW air-cooled long-arc lamps) |
| Lamp Lifetime | 1200 hours |
| Irradiance | 550 W/m² ±10 W/m² (290–2450 nm broadband spectrum) |
| Humidity Range | 50–90 %RH ±5 %RH |
| Internal Chamber Dimensions (W×D×H) | 750×600×600 mm |
| Black Panel Temperature Range | 40–90 °C ±3 °C |
| Water Spray Duration | 1–9999 min 59 sec adjustable |
| Spray Interval | 1–240 min adjustable |
| Effective Exposure Area | ≥3000 cm² |
| Sample Rack Size | 750×600 mm (1 pcs) |
| Distance from Arc Center to Specimen | 300 mm |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HD-E714 |
| Temperature Range | −40 °C to +100 °C |
| Refrigeration Method | Compressor-based Cooling |
| Explosion-Proof | Standard (Non-Explosion-Proof) |
| Temperature Uniformity | ≤2 °C |
| Temperature Stability | ±0.5 °C |
| Temperature Deviation | ±2 °C |
| Heating Rate | ≥1 °C/min |
| Cooling Rate | ≥1 °C/min |
| Internal Chamber Dimensions | 1000 mm × 1000 mm × 1000 mm (1 m³) |
| Pressure Range | 101.3 kPa (ambient) to 1 kPa |
| Pressure Control Accuracy | ±5% |
| Depressurization Time (101.3 kPa → 1 kPa) | ≤30 min |
| Power Supply | 380 V AC, 50 Hz, 3-phase 5-wire |
| Control Resolution | Temperature 0.1 °C, Pressure 0.01 Pa |
| Control Accuracy | Temperature ±0.5 °C, Pressure ±1.0 Pa |
| Vacuum System | Oil-free, Clean Scroll Vacuum Pump with Integrated Piezoresistive Pressure Transducer |
| Insulation | Multi-layer Composite Pressure-Rated Polyurethane + Ultra-fine Glass Fiber |
| Inner Chamber Material | SUS304 Stainless Steel |
| Door Seal | Dual-layer High-Temperature Silicone Rubber Gasket |
| Safety Protections | Over-temperature, over-current, compressor high-pressure, motor overheat, leakage, short-circuit, phase-loss, under/over-voltage, oil-level monitoring |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HD-E801 |
| Ozone Concentration Range | 50–1000 pphm |
| Ozone Control Accuracy | ±10 pphm (50–100 pphm), ±10% (100–1000 pphm) |
| Temperature Range | 20–60 °C |
| Temperature Uniformity | ±2 °C (empty chamber) |
| Temperature Stability | ±0.5 °C |
| Humidity Range | 30–98 %RH |
| Airflow Rate | 100 L/min |
| Internal Dimensions | 400 × 500 × 500 mm (D×W×H) |
| External Dimensions | 950 × 980 × 1650 mm (D×W×H) |
| Net Volume | 800 L |
| Dynamic Sample Rotation Speed | 2–10 rpm (adjustable) |
| Vertical Extension Frequency | 2–15 cycles/min |
| Extension Stroke | 20–100 mm (adjustable) |
| Refrigerant | R404a |
| Compressor | Hermetic French Tecumseh unit |
| Heating System | SUS304 U-shaped finned tubular heater (1500 W) |
| Humidification System | SUS304 U-shaped humidifier |
| Ozone Generator | Silent high-voltage corona discharge type |
| Ozone Sensor | Electrochemical sensor |
| Controller | TEMP880 high-precision color touchscreen PID controller with USB/RS232/RS485 interfaces |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 2951.5–1997 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HD-E802-2 |
| Humidity Range | Ambient to 70°C |
| UV Lamp Power | 40 W per lamp |
| Max Data Logging Duration | 60 days (at 1.5-min sampling interval) |
| Irradiation Temperature Range | Ambient to 70°C |
| UV Wavelength Range | 200–480 nm |
| Chamber Internal Dimensions (W×H×D) | 1300 × 1480 × 550 mm |
| Sample Rack Configuration | Tilted tower, 4 racks × 493 × 300 mm each |
| Sample Size per Rack | 75 × 150 mm (2 slots per rack) |
| Lamp Quantity | 8 fluorescent UV lamps (4 front + 4 rear) |
| Lamp Center-to-Center Spacing | 70 mm |
| Sample Surface-to-Lamp Distance | 50 ± 3 mm |
| Spray Nozzles | 8 (4 front + 4 rear), adjustable pressure 70–200 kPa |
| Lamp Length | 1220 mm |
| Lamp Lifetime | ≥1600 h |
| Temperature Resolution | 0.01°C |
| Temperature Uniformity | ±2°C |
| Temperature Fluctuation | ±1°C |
| Temperature Deviation | ±1°C |
| Control System | Q-TEST touchscreen PID controller with RS-232 interface |
| Compliance Standards | GB/T 23987–2009, ISO 11507:2007, GB/T 14522–2008, GB/T 16422.3–2014, ISO 4892-3:2006, ASTM G154, ASTM G153, IEC 61215:2005 (Clause 10.10) |