| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | AFS-8900 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Peristaltic Pump |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| Detection Mode | Hydride Generation – Cold Vapor Atomic Fluorescence Spectrometry (HG-CV-AFS) |
| Automation Features | Onboard Calibration Curve Generation, Auto-dilution, Full Measurement Automation |
| Lamp System | High-Performance Encoded Hollow Cathode Lamps with Lifetime Monitoring |
| Atomizer | Shielded Low-Temperature Quartz Furnace Atomizer |
| Gas-Liquid Separator | Sealed Two-Stage Separation Unit |
| Gas Control | Array-Structured Argon Flow System with Flow Optimization Module |
| Software Platform | Windows 7/8/10/XP Compatible AFS Control Suite with Audit Trail & Data Export to Excel |
| Compliance Ready | Designed for GLP/GMP environments |
| Upgrade Interfaces | 预留形态分析、Hg/Cd电热蒸发接口 |
| Safety & Diagnostics | Real-time Argon-Hydrogen Flame Monitoring Window, Power Isolation Architecture, Self-Check & Fault Alert Protocol |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AFS-9530 |
| Price Range | USD 42,000 – 56,000 |
| Instrument Type | Single-Channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| RSD | <1.0% (typical for As at 1 µg/L) |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits (3σ) | As, Hg, Se < 0.01 µg/L |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-made) |
| Model | AFS-9560 |
| Price Range | USD 56,000 – 70,000 (FOB Beijing) |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| RSD | <1.0% (for As at 1 µg/L, n=11) |
| Linear Dynamic Range | >3 orders of magnitude (typical for hydride-generating elements) |
| Detection Limits | Sub-pg/mL level (e.g., As: 0.01 ng/L |
| Hg | 0.001 ng/L |
| Se | 0.03 ng/L, per ISO 17294-2 and GB/T 223.74–2021) |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AFS-9600 |
| Price Range | USD 42,000 – 56,000 |
| Instrument Type | Single-Channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Peristaltic Pump |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au |
| RSD | <1.0% (for As at 1 µg/L) |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | Sub-pg/mL level for As, Hg, Se (e.g., As ≤ 0.01 µg/L, Hg ≤ 0.001 µg/L, Se ≤ 0.03 µg/L) |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | AFS-9710 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Sequential Injection Pump |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| Sample Tray Capacity | 69 × 25 mL / 134 × 15 mL / 183 × 10 mL coordinate-style autosampler |
| Valving Technology | Clamp-tube valve (≥500,000 cycles lifetime) |
| Atomizer | Shielded low-temperature quartz furnace atomizer |
| Gas–Liquid Separator | Closed-loop dual-stage cyclonic separator |
| Lamp System | Encoded hollow-cathode lamps with auto-identification and life monitoring |
| Gas Control | Array-structured argon flow system with intelligent gas-saving module |
| Software Platform | Windows XP/7/8/10 compatible |
| Compliance Features | Built-in self-diagnostic routines, real-time flame status monitoring via observation window, GLP/GMP-ready audit trail logging (via optional software module), 21 CFR Part 11 compliance achievable with validated configuration |
| Upgrade Options | LC-AFS hyphenation interface for elemental speciation (e.g., As(III)/As(V), methylmercury), electrothermal evaporation (ETV) modules for Hg/Cd, automated dilution and calibration curve generation |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | AFS-9770 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Integrated Sequential Injection with Peristaltic Pump |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| Optical Configuration | Fixed Four-Channel Short-Focal-Length Lens System |
| Atomizer | Argon-Hydrogen Flame Shielded Quartz Furnace with Dual-Zone Independent Temperature Control (Room Temp–450 °C) |
| Detection System | R7154 Photomultiplier Tube (PMT), Japan |
| Auto-sampler Capacity | 180-position Rotary Tray |
| Software Compliance | Audit Trail, User Permission Management, Data Traceability per FDA 21 CFR Part 11 & GLP Requirements |
| Gas Control | Triple-Channel Digital Mass Flow Controller (Carrier, Shield, Auxiliary Ar) |
| Safety Systems | Real-time Leak, Pressure, Flame, Temperature, and Ambient Hazard Gas Monitoring |
| Exhaust Treatment | Integrated Hydride Trap for Toxic Effluent Capture |
| Brand | Haiguang Instrument |
|---|---|
| Type | Flame AAS |
| Background Correction | Zeeman-effect |
| Optical System | Single-beam with quasi-dual-channel reference |
| Monochromator | Concave grating |
| Detector | Photomultiplier tube (PMT) |
| Slit Width Options | 0.2, 0.4, 1.0, 2.0 nm |
| Magnetic Field | 1 T DC transverse configuration |
| Cooling | Water-cooled magnet assembly |
| Safety | Interlock and flashback arrestor systems |
| Software Platform | Windows 7/8-based control and data processing suite |
| Measurement Modes | Atomic absorption, Zeeman background correction, flame emission |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | GGX-600 |
| Instrument Type | Flame AAS |
| Monochromator | Echelle grating |
| Optical System | Double-beam |
| Detector | Photomultiplier tube (PMT) |
| Background Correction | Deuterium lamp background correction |
| Spectral Bandwidth | 0.2, 0.4, 1.0, 2.0 nm (auto-switchable) |
| Wavelength Range | 190–900 nm |
| Burner Head | Titanium alloy, 3D adjustable |
| Nebulizer | High-efficiency concentric glass nebulizer with impact bead |
| Spray Chamber | Corrosion-resistant treated mixed-type chamber |
| Safety Features | Gas cutoff interlock, flame-out protection, power failure auto-shutdown |
| Software Platform | Windows 7/8/XP compatible AAS control and data analysis suite |
| Compliance | GB 5009.x series, HJ 491-2019, HJ 757-2015, GB/T 17141-1997 |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | GGX-610 |
| Instrument Type | Flame AAS |
| Monochromator | Concave Grating |
| Optical System | Single-beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Spectral Bandwidth | 0.2 / 0.4 / 1.0 / 2.0 nm (motorized switching) |
| Wavelength Range | 190–900 nm |
| Flame Emission Capability | Yes (for K, Na, Li) |
| Safety Features | Automatic gas cutoff, flame failure interlock, flashback arrestor |
| Housing Material | Corrosion-resistant all-plastic enclosure |
| Software Platform | Windows 7/8/XP-compatible proprietary AAS control and data analysis suite |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | GGX-810 |
| Instrument Type | Flame AAS |
| Monochromator | Plane grating (1800 lines/mm) |
| Optical System | Single-beam |
| Detector | Photomultiplier tube (PMT) |
| Background Correction | Deuterium lamp (D₂) method |
| Burner Head | Titanium alloy |
| Atomization System | Full-plastic nebulizer chamber + high-efficiency glass concentric nebulizer |
| Safety Features | Water seal detection, waste liquid level monitoring, gas pressure monitoring, flame sensor, automatic gas cutoff on flameout, anti-flashback protection |
| Graphite Furnace Option | Longitudinal heating |
| Temp. range | ambient to 3000 °C |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | GGX-820 |
| Instrument Type | Graphite Furnace AAS |
| Optical System | Single-beam |
| Monochromator | Plane grating (1800 lines/mm) |
| Focal Length | 270 mm |
| Background Correction | Deuterium (D₂) Lamp |
| Detector | Photomultiplier Tube (PMT) |
| Atomizer | Integrated Flame/GF system (flame mode optional per GGX-830 reference) |
| Graphite Furnace Heating | Longitudinal |
| Temperature Range | Ambient to 3000 °C |
| Temperature Control Accuracy | ≤0.5% at 2000 °C |
| Maximum Ramp Rate | ≥2000 °C/s |
| Autosampler | 52-position, programmable matrix modifier addition, sample delivery precision ≤±0.5% |
| Safety Systems | Flame failure cutoff, gas pressure monitoring, liquid level sensing, water seal detection, anti-flashback design, automatic gas shutoff |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | GGX-830 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane grating (1800 lines/mm) |
| Optical System | Single-beam |
| Detector | Photomultiplier tube (PMT) |
| Background Correction | Deuterium (D₂) lamp |
| Burner Head | Titanium alloy |
| Graphite Furnace | Longitudinal heating, temperature range: ambient to 3000 °C, temperature control accuracy ≤0.5% at 2000 °C, ramp rate ≥2000 °C/s |
| Autosampler | 52-position graphite furnace autosampler with automated calibration curve generation, matrix modifier addition capability, and sample delivery precision ≤±0.5% |
| Safety Systems | Flame monitoring, gas pressure sensing, water seal detection, waste liquid level detection, anti-flashback protection, automatic fuel cutoff upon flameout |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | GGX-900 |
| Instrument Type | Flame AAS |
| Monochromator | Concave Grating |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Spectral Bandwidth | 0.2 / 0.4 / 1.0 / 2.0 nm (motorized switching) |
| Wavelength Range | 190–900 nm |
| Flame Atomization System | Titanium Alloy Burner, Corrosion-Resistant Hybrid Nebulizer Chamber, High-Efficiency Glass Concentric Nebulizer with Impact Bead |
| Safety Features | Gas/Air Interlock, Automatic Flame-Out Cutoff, Over-Temperature Alarm for Magnet Assembly, Water-Cooled Permanent Magnet |
| Software Platform | Windows 7/8/XP Compatible AAS Control & Data Analysis Suite with ASTM/ISO/GLP-Compliant Audit Trail, Excel Export, Multi-Mode Quantitation (Absorption, Background-Subtracted Absorption, Pure Background, Emission) |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGA-100 |
| Instrument Type | Online Mercury Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Sample Introduction | Solid/Liquid/Gas Direct Injection |
| Analysis Time | <5 min per sample |
| Sample Capacity | 40-position Autosampler |
| Reagent Consumption | Zero chemical reagents required |
| Temperature-Controlled Flow Path | Yes |
| Gold Amalgamation Trap | Nano-coated Au-Hg trap integrated |
| Catalyst System | Dual-stage composite catalyst |
| Exhaust Treatment | Integrated catalytic oxidation + activated carbon adsorption |
| Compliance Framework | Designed for GLP-compliant laboratories |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGA-E30 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical Design | Czerny-Turner with 270 mm focal length and 1800 lines/mm grating |
| Slit Widths | 6 auto-switchable positions |
| Light Source | 8-lamp rotating turret with simultaneous preheating |
| Lamp Recognition | Automatic identification of hollow cathode lamps (HCL), self-reversal lamps, and high-performance lamps |
| Background Correction | D₂ lamp and self-absorption methods across full wavelength range (190–900 nm) |
| Atomization Modes | Flame (triple-gas flow control with safety interlock) and electrothermal graphite furnace (integrated power supply) |
| Autosampler | 84-position sliding-type flame/graphite furnace integrated autosampler |
| Software Functions | Auto-alignment, auto-peak search, auto-slit selection, startup diagnostics, and analytical condition recommendation |
| Optional Accessories | Hydride generation system for As, Hg, Se, Sb, Bi, etc. |
| Compliance | Fully supports GB, HJ, and ISO 8288, ISO 11170, ASTM D5059, USP <730>, FDA 21 CFR Part 11 (audit trail enabled) |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGA-E50 |
| Instrument Type | Flame–Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Safety Features | Over-Temperature Alarm, Low Gas Pressure Alert, Graphite Tube Break/Loose Clamp Detection |
| Automated Functions | Self-Check at Startup, Automatic Slit Adjustment, Peak Search, Lamp Positioning |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HGCF-100 for Ammonia Nitrogen |
| Price Range | USD 28,000 – 35,000 |
| Instrument Type | Laboratory Benchtop |
| Measurement Principle | Air-Segmented Continuous Flow Analysis (CFA) with Distillation and Colorimetric Detection |
| Measurement Range | 0.01–5 mg/L NH₃–N |
| Accuracy | ±1% of reading |
| Detection Limit | ≤0.005 mg/L NH₃–N |
| Sample Throughput | 30 samples/hour |
| Batch Capacity | Unlimited (software-controlled queue) |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGCF-100 |
| Product Type | Continuous Flow Analyzer (CFA) |
| Air Segmentation Technology | Yes |
| Online Pretreatment Modules | Heating, Digestion, Distillation, Dialysis, Extraction, Deaeration |
| Detection Options | Full-spectrum CCD detector or high-sensitivity dual-beam silicon photodiode detector |
| Flow Cell Pathlength Options | 10 mm – 200 mm |
| Reaction Coil Material | Fused silica (2 mm ID) |
| Sample Introduction | Optional autosampler with automatic needle cleaning, programmable wash solution replacement, carbon fiber or borosilicate glass sampling probes |
| Compliance Standards | GB, HJ, EPA Methods (e.g., EPA 375.4, 450.1, 420.1), ISO 6878, ISO 11908, ISO 15681 |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HGCF-100 |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | Total Cyanide, Free Cyanide, Volatile Phenols, Anionic Surfactants (LAS), Ammonia-Nitrogen (NH₃-N), Orthophosphate, Total Phosphorus, Total Nitrogen, Sulfides, Hexavalent Chromium (Cr⁶⁺), Nitrate, Nitrite, Permanganate Index (CODₘₙ), Urea |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | HGCF-100 Cyanide |
| Price Range | USD 21,000 – 42,000 (FOB Beijing) |
| Instrument Type | Benchtop Laboratory Analyzer |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGCF-100 (Volatile Phenol Configuration) |
| Instrument Type | Benchtop Laboratory Continuous Flow Analyzer |
| Compliance | GB, HJ, EPA, ISO Standard Methods |
| Sample Throughput | Batch-mode Automated Analysis |
| Detection Principle | Air-Segmented Continuous Flow with On-line Distillation and Spectrophotometric Detection |
| Optical Detection | Full-spectrum CCD or Dual-beam Silicon Photodiode Detector |
| Reaction Coil | 2 mm ID Quartz Mixing Coil |
| On-line Pretreatment | Integrated Steam Distillation, Heating, Mixing, Dilution, and Auto-Cleaning |
| Automation Level | Fully Automated Including Auto-Sampling, Reagent Dispensing, Reaction Control, Data Acquisition, and System Flush |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGCF-200 / HGCF-210 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Parameters | Total Cyanide, Free Cyanide, Volatile Phenol, Anionic Detergents, Ammonia Nitrogen (NH₃-N), Orthophosphate, Total Phosphorus, Total Nitrogen, Sulfide, Hexavalent Chromium (Cr⁶⁺), Nitrate, Nitrite, Permanganate Index (CODₘₙ), Urea |
| Compliance Standards | HJ 665–2013, HJ 670–2013, HJ 667–2013, CJT 141–2018, SL/T 788–2019, NY/T 1121.7–2014, NY/T 1228–2015, ISO 14403:2012, ISO 14402:1999, ISO 23913:2016, ISO 15681-2:2003 |
| Optical Detection | Dual-beam silicon photodetector or full-spectrum CCD detector |
| Flow Cell Pathlength Options | 10 mm to 200 mm |
| Reaction Coil | 2 mm i.d. quartz mixing coil |
| Sample Introduction | Automated sampler with carbon fiber or borosilicate glass probe, auto-cleaning and wash solution auto-replacement |
| Online Pretreatment | Integrated heating, digestion, distillation, dialysis, extraction, degassing, dilution, and mixing modules |
| Light Source | Low-power LED with short stabilization time and >10,000 h lifetime |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGCF-200 Ammonia Nitrogen |
| Measurement Principle | Colorimetric Flow Analysis (Salicylate Method) |
| Measurement Range | 0.01–5 mg/L NH₃–N |
| Detection Limit | ≤0.005 mg/L NH₃–N |
| Accuracy | ±1% of reading |
| Sample Throughput | 30 samples/hour |
| Batch Capacity | Unlimited |
| Optical Cell Material | Fused quartz |
| Light Source | Low-power LED |
| Detector | Full-spectrum CCD with built-in monochromator |
| Online Dilution Ratio | 1–5000× |
| Reaction Tubing ID | ≥2 mm |
| Compliance | HJ 665-2013, HJ 670-2013, HJ 667-2013, ISO 14403:2012, ISO 14402:1999, ISO 23913:2016, ISO 15681-2:2003 |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Instrument Type | Laboratory Benchtop CFA |
| Application | Total and Free Cyanide Determination in Water and Environmental Matrices |
| Compliance | ASTM D7511, ISO 14403:2012, HJ 484–2009, EPA Method 335.4 |
| Detection Principle | Segmented Flow Analysis (SFA) with Air Segmentation, On-line Distillation & UV Digestion |
| Optical System | LED-based Photometer with Quartz Flow Cell and Full-spectrum CCD Detector |
| Sample Throughput | Up to 60 samples/hour |
| Detection Limit | ≤0.2 µg/L CN⁻ (as applicable per ISO 14403) |
| Linear Dynamic Range | 0–1000 µg/L (adjustable via on-line dilution 1:1 to 1:5000) |
| Reagent Management | Integrated Smart Reagent Rack with Level Sensing & Leak Detection |
| Automation | Fully Automated Sample Introduction, Pre-treatment, Reaction, Separation, Detection & Data Reporting |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGCF-200 Volatile Phenol |
| Instrument Type | Laboratory-Based Volatile Phenol Analyzer |
| Compliance | ASTM D3164, ISO 14402:1999, ISO 23913:2016, ISO 15681-2:2003, HJ 665–670/667–2013, CJT 141–2018, SL/T 788–2019, NY/T 1121.7–2014, NY/T 1228–2015 |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HGCF-200 |
| Price Range | USD 70,000 – 100,000 (FOB China) |
| Instrument Type | Continuous Flow Analyzer (CFA) |
| Detection Principle | Segmented Flow Spectrophotometry with Air Segmentation |
| Optical Detection Options | Full-spectrum CCD detector or high-sensitivity dual-beam silicon photodiode detector |
| Flow Cell Pathlength Options | 10 mm to 200 mm |
| Reaction Coil Material | Fused silica (2 mm inner diameter) |
| Integrated Sample Pretreatment | On-line digestion, distillation (steam distillation/blow-out), dialysis, extraction, heating, mixing, dilution, degassing, and auto-cleaning |
| Compliance Standards | ASTM D3869, ISO 14402, ISO 14403, ISO 23913, ISO 15681-2, HJ 665–667, HJ 670, CJJ/T 141, SL/T 788, NY/T 1121.7, NY/T 1228 |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HGD Series |
| Price Range | USD 42,000 – 70,000 |
| Instrument Type | Graphite Block Digestion System |
| Automation Level | Fully Automated |
| Digestion Positions | Configurable up to 48 samples (standard configuration) |
| Temperature Range | Ambient to 220 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Heating Principle | Uniform graphite block conduction with PID-controlled dual-zone heating |
| Reagent Dispensing Channels | Up to 6 independent corrosion-resistant reagent lines (HNO₃, HCl, HF, H₂O₂, etc.) |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HGF-U |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Compliance | Fully aligned with 100+ national and industry standards for AFS analysis (e.g., GB, HJ, GBZ/T, SL) |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGF-V2 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Gravity-based |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits (As, Se, Pb, Bi, Sb, Te, Sn) | < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 50–450 °C |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-made) |
| Model | HGF-V3 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Liquid Disposal | Gravity-driven (Static) |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controllers (MFCs) |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Se, Pb, Bi, Sb, Te, Sn < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 50–450 °C |