Volatile Phenol Analyzer
Filter
Showing all 15 results
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | BG00750001 |
| Instrument Type | Online Volatile Phenol Analyzer |
| Output Interfaces | 4–20 mA, RS232/RS485, MODBUS RTU/TCP, Ethernet (optional) |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory-Based Volatile Phenol & Anionic Detergent Analyzer |
| Model | 3100 |
| Compliance Standards | GB/T 7494–1987, GB/T 5750.4–2006, HJ 503–2009 |
| Configuration | Fully Automated Benchtop System with Integrated Sample Handling, Extraction, Reaction, and Photometric Detection |
| Brand | ERUN |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | ERUN-ST7-B4 |
| Instrument Type | Laboratory Benchtop Volatile Phenol Analyzer |
| Measurement Principle | Spectrophotometry (4-Aminoantipyrine Method per ISO 6439 & HJ 503-2009) |
| Range | 0.2–10.00 mg/L |
| Accuracy | ±5% FS |
| Repeatability | ≤2% RSD |
| Baseline Drift | <0.002 Abs/30 min |
| Wavelength Selection | Auto-selectable (500 nm standard for phenol detection) |
| Optical System | Fixed-wavelength LED-based photometer with calibrated optical path |
| Light Intensity Control | 16-step adjustable intensity |
| Calibration Curve Options | Linear or Multi-point Nonlinear (up to 8 calibration points) |
| Data Storage | 100,000 records (timestamp, absorbance, transmittance, concentration, user ID, curve ID) |
| Display | 7-inch capacitive color touchscreen with on-screen operation guide |
| Connectivity | USB 2.0 host port for data export (CSV format), no network or cloud interface |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Environmental Requirements | Stable lab environment — no direct sunlight, minimal vibration, low EMI |
| Compliance | Designed to support compliance with ISO/IEC 17025 quality management systems |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | VAPODEST 200 |
| Instrument Type | Benchtop Volatile Phenol Distillation Unit |
| Water Consumption | ~5 L/min |
| Distillation Time | 2–4 min |
| Power Rating | 2200 W |
| Voltage/Frequency | 230 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 527 × 390 × 697 mm |
| Weight | 25 kg |
| Repeatability | ±1% |
| Detection Limit | 0.1 mg |
| Recovery Rate | ≥99.5% |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGCF-100 (Volatile Phenol Configuration) |
| Instrument Type | Benchtop Laboratory Continuous Flow Analyzer |
| Compliance | GB, HJ, EPA, ISO Standard Methods |
| Sample Throughput | Batch-mode Automated Analysis |
| Detection Principle | Air-Segmented Continuous Flow with On-line Distillation and Spectrophotometric Detection |
| Optical Detection | Full-spectrum CCD or Dual-beam Silicon Photodiode Detector |
| Reaction Coil | 2 mm ID Quartz Mixing Coil |
| On-line Pretreatment | Integrated Steam Distillation, Heating, Mixing, Dilution, and Auto-Cleaning |
| Automation Level | Fully Automated Including Auto-Sampling, Reagent Dispensing, Reaction Control, Data Acquisition, and System Flush |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGCF-200 Volatile Phenol |
| Instrument Type | Laboratory-Based Volatile Phenol Analyzer |
| Compliance | ASTM D3164, ISO 14402:1999, ISO 23913:2016, ISO 15681-2:2003, HJ 665–670/667–2013, CJT 141–2018, SL/T 788–2019, NY/T 1121.7–2014, NY/T 1228–2015 |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Volatile Phenol Analyzer |
| Model | GDYS-103SK |
| Detection Limit | 0.1 mg/L |
| Measurement Range | 0.0–5.0 mg/L |
| Accuracy | ±5% |
| Analysis Time | ≤10 minutes |
| Reagent Format | Single-use, pre-packaged test kit |
| Compliance | Designed for field-deployable water quality screening per standard colorimetric phenol detection protocols |
| Brand | Lianhua |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LH-T6VFA |
| Instrument Type | Benchtop VFA Analyzer for Laboratory Use |
| Measurement Principle | Esterification-Based Spectrophotometry |
| Brand | Lianhua Tech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LH-P3VFA |
| Instrument Type | Portable VFA Analyzer |
| Measurement Principle | Esterification-based Spectrophotometry |
| Analysis Time | ≤20 min per sample |
| Display Units | mg/L or mmol/L (auto-switchable) |
| Power Supply | Built-in rechargeable Li-ion battery (8 h field operation) |
| Interface | USB Type-C (data transfer & charging) |
| Optical System | Calibratable light source with enhanced stability and longevity |
| Brand | New Environmental Protection Industry in Qingdao |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | XY-600H |
| Instrument Type | Portable Volatile Phenol Analyzer |
| Detection Range | 0–12 mg/L |
| Detection Limit | 0.05 mg/L |
| Measurement Error | ≤±5% |
| Repeatability Error | ≤±3% |
| Wavelength Accuracy | ±1 nm |
| Optical Stability | ≤±0.001 A/20 min |
| Cuvette Type | Integrated Digestion–Colorimetric Tube |
| Wavelength Selection | Automatic by Parameter |
| Wavelength Calibration | Auto-calibration |
| Light Source | Dedicated Solid-state Cold Light Source |
| Displayed Data | Concentration, Transmittance (%), Absorbance (A) |
| Data Interface | USB |
| Printing | Built-in Thermal Printer |
| Data Storage | 100,000 Records, 120 Calibration Curves (including user-defined) |
| Display | 7-inch HD Color Touchscreen |
| Operating Environment | 5–45 °C, ≤50% RH (non-condensing) |
| Power Supply | DC 12 V / 2 A |
| AC Input | 100–240 V, 50–60 Hz |
| Dimensions | 350 × 220 × 130 mm |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | OL 2030N |
| Instrument Type | Laboratory-Grade Volatile Phenol & Anionic Surfactant Analyzer |
| Sample Capacity | Anionic Surfactant – up to 55 positions |
| Sample Introduction | Rotary Disk Autosampler |
| Fluid Handling | Precision Syringe + Peristaltic Pump Hybrid Delivery |
| Extraction Protocol | Programmable Multi-Stage Chloroform Extraction & Back-Extraction (compliant with GB 7494-1987, HJ 503-2009, GB/T 39302-2020, etc.) |
| Calibration | Fully Automated Standard Preparation, Multi-Point Curve Generation, and Auto-Dilution for High-Concentration Samples |
| Waste Management | Closed-Loop Waste Collection, Activated Carbon Exhaust Scrubbing |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | OL2020N |
| Instrument Type | Laboratory-Grade Volatile Phenol Analyzer |
| Sample Capacity | 10 / 22 / 25 positions (field-upgradable) |
| Automation Level | Fully Automated (distillation, reagent addition, liquid transfer, extraction, spectrophotometric measurement) |
| Calibration | Auto-standard preparation & multi-point calibration curve generation |
| Reagent Management | Real-time monitoring, low-reagent alert, closed-loop waste & fume collection |
| Data Interface | LIMS-compatible, remote monitoring via web browser or mobile application |
| Compliance | Designed per HJ 503–2009 and HJ 998–2018 (China EPA standards) |
| Safety Architecture | Fully enclosed operation with integrated fume absorption system |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OL2200N |
| Instrument Type | Laboratory-Based Volatile Phenol Analyzer |
| Sample Capacity | 45 positions (expandable upon customization) |
| Distillation Stations | 8 parallel |
| Automation Level | Fully Automated (XYZ robotic sampling, auto-calibration, auto-distillation, reagent addition, phase transfer, liquid-liquid extraction, spectrophotometric quantification) |
| Standard Preparation | Automated multi-point standard curve generation |
| Waste Handling | Closed-loop exhaust and waste liquid collection system |
| Reagent Monitoring | Real-time level sensing with low-reagent alert |
| Remote Access | Web-enabled instrument control and data retrieval via secure HTTPS interface |
| Compliance Framework | Designed to support ISO 6439, HJ 502–2009 (Chinese EPA method), and ASTM D1783–20 for phenolic compounds in water |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CHVP-301 |
| Instrument Type | Benchtop Volatile Phenol Analyzer |
| Measurement Range | 0.1–10 mg/L |
| Accuracy | ≤ ±5% FS |
| Repeatability | ≤ 3% RSD |
| Optical Drift | < 0.002 A over 20 min |
| Dimensions (W×D×H) | 266 × 200 × 130 mm |
| Weight | < 1 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤ 85% RH |
| Power Supply | AC 220 V ± 10%, 50 Hz ± 0.5 Hz |
| Housing Material | ABS with corrosion resistance |
| Brand | ShengAohua |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory-Grade Volatile Phenol Analyzer |
| Model | 6B-50HFF(V10) |
| Measurement Range | 0–3 mg/L |
| Accuracy | ≤ ±5% |
| Repeatability | ≤ ±5% |
| Analysis Time | 1 minute per sample |
| Preloaded Calibration Curves | 5 |
| Data Storage Capacity | 5,000,000 measurement records |
| Light Source | Cold LED with Narrow-Band Interference Filter (Lifetime ≥ 100,000 hours) |
| Display | Large LCD with Chinese GUI and Guided Menu Navigation |