JENSPRIMA
Filter
Showing all 7 results
| Brand | JENSPRIMA |
|---|---|
| Origin | Shanghai, China |
| Model | innoCon 6500C |
| Conductivity Range | 0.00–20.00 / 200.0 / 2000 µS/cm, 0.00–20.00 / 200.0 / 2000 mS/cm |
| Resistivity Range | 0.00–20.00 MΩ·cm |
| TDS Range | 0.00 ppm–200.0 ppt |
| Resolution | 0.01/0.1/1 µS/cm, 0.1/1 mS/cm, 0.01 MΩ·cm, 0.01/0.1/1 ppm, 0.1 ppt |
| Accuracy | ±1% FS |
| Temperature Sensor | Pt1000 |
| Temp. Compensation | Automatic (with ±10.0 °C offset adjustment) or Manual |
| Operating Temp. | −10.0 to +60.0 °C |
| Humidity | 10–90% RH (non-condensing) |
| Display | Backlit LCD (44×65 mm), yellow backlight |
| Power Supply | 90–260 VAC, 50/60 Hz |
| Outputs | Two isolated 4–20 mA analog outputs (configurable, max. 600 Ω load) |
| Relay Outputs | Two independent SPST relays (Hi/Lo alarm, hysteresis adjustable |
| Enclosure Rating | IP54 |
| Mounting | Panel mount (cutout: 92×92 mm) |
| Dimensions | 96×96×130 mm |
| Weight | 0.45 kg |
| Brand | JENSPRIMA |
|---|---|
| Origin | Shanghai, China |
| Model | innoCon 6500CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor |
| Measured Parameters | Free Chlorine, Chlorine Dioxide, Ozone (multi-parameter) |
| Range | 0.000–2.000 ppm and 0.00–20.00 ppm |
| Accuracy | ±2% F.S. |
| Resolution | 0.001 ppm / 0.01 ppm |
| Detection Limit | 0.001 ppm |
| Temperature Compensation | Automatic (Pt1000 sensor, ±10.0 °C offset adjustable) or Manual |
| Operating Temperature | –10.0 to +60.0 °C |
| Relative Humidity | 10–90% RH (non-condensing) |
| Display | Backlit LCD (44 × 65 mm, yellow backlight) |
| Power Supply | 90–260 VAC, 50/60 Hz |
| Output Signals | Two isolated 4–20 mA outputs (configurable, max. 600 Ω), RS485 Modbus RTU |
| Relay Outputs | Two SPDT relays (5 A / 250 VAC, 5 A / 30 VDC), independently configurable Hi/Lo alarm with hysteresis |
| Enclosure Rating | IP54 |
| Mounting | Panel-mount (DIN 43700, cutout 92 × 92 mm) |
| Dimensions | 96 × 96 × 130 mm |
| Weight | 0.45 kg |
| Housing Material | Flame-retardant plastic |
| Brand | JENSPRIMA |
|---|---|
| Origin | Shanghai, China |
| Model | innoCon 6800T |
| Product Type | Online Analyzer |
| Turbidity Range | 0.0–4.0 / 40.0 / 400.0 / 1000.0 NTU |
| SS Range | 0.0–10.0 / 100.0 / 1000.0 / 2000.0 mg/L |
| Resolution | 0.1 NTU, 0.1 mg/L |
| Operating Temperature | 0–60 °C |
| Accuracy | ±2% of full scale |
| Output | Dual 4–20 mA (turbidity & temperature), RS485 Modbus RTU |
| Enclosure Rating | IP65/NEMA 4X |
| Sensor Protection Rating | IP68 |
| Sensor Material | 316L stainless steel housing, custom optical glass |
| Sensor Dimensions | Ø42 mm × 210 mm L, 1" NPT male thread |
| Max Pressure | 4 bar |
| Cable Length | 10 m standard |
| Brand | JENSPRIMA |
|---|---|
| Origin | Shanghai, China |
| Model | innoMag 300-1 |
| Body Type | Integral or Remote (S/L) |
| Pipe Size Range | DN10–DN2000 |
| Flow Range | 0.2–30,000 m³/h |
| Accuracy | ±0.5% of reading |
| Repeatability | ±0.1% of reading |
| Minimum Conductivity | ≥5 µS/cm |
| Electrode Materials | 316L SS, Hastelloy C, Tantalum, Titanium, Platinum |
| Lining Materials | PTFE (DN10–DN1000), Hard Rubber (DN50–DN2000) |
| Process Temperature | PTFE: –40 to +150°C |
| Rubber | –10 to +80°C |
| Ambient Temperature | –20 to +70°C |
| Output Signals | 4–20 mA (max. 750 Ω), Pulse/Frequency, Alarm Relay |
| Communication Protocols | MODBUS RTU (standard), HART (optional) |
| Power Supply | 85–260 VAC or 24 VDC |
| Brand | JENSPRIMA |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | InnoMag 320 |
| Pricing | Available Upon Request |
| Construction Type | Integral (S-type) or Remote (L-type) |
| Nominal Diameter Range | DN10–DN2000 |
| Flow Range | 0.2–30,000 m³/h |
| Accuracy | ±0.5% of reading |
| Repeatability | ±0.1% of reading |
| Display | Backlit LCD |
| Installation | Flanged (custom clamp-on option available) |
| Minimum Conductivity | ≥10 µS/cm |
| Electrode Materials | 316 Stainless Steel, Hastelloy C, Tantalum, Titanium |
| Lining Materials | PTFE (DN10–DN1000), Rubber (DN50–DN2000) |
| Housing Materials | Controller – Aluminum |
| Temperature Limits | PTFE Lining – –40 to +150 °C |
| Ambient Operating Temperature | –20 to +70 °C |
| Output Signals | 4–20 mA (max. 750 Ω), Pulse Output, Frequency Output |
| Communication Protocols | MODBUS RTU (standard), HART (optional) |
| Power Supply | 85–260 VAC or 24 VDC |
| Brand | JENSPRIMA |
|---|---|
| Origin | Shanghai, China |
| Model | innoMag300 |
| Nominal Diameter Range | DN10–DN2000 |
| Flow Range | 0.2–30,000 m³/h |
| Accuracy | ±0.5% of reading |
| Repeatability | ±0.1% of reading |
| Minimum Conductivity | ≥5 µS/cm |
| Electrode Materials | 316 Stainless Steel, Hastelloy C, Tantalum, Titanium |
| Lining Materials | PTFE (DN10–DN1000), Rubber (DN50–DN2000) |
| Lining Temperature Limits | PTFE: –40 to +150 °C |
| Rubber | –10 to +80 °C |
| Ambient Operating Temperature | –20 to +70 °C |
| Output Signals | 4–20 mA (max. 750 Ω), Pulse, Alarm |
| Communication Protocols | MODBUS RTU (standard), HART (optional) |
| Power Supply | 85–260 VAC or 24 VDC |
| Housing Material | Aluminum |
| Installation Types | Integral (S-type), Remote (L-type) |
| Bidirectional Flow Measurement | Yes |
| Pressure Loss | Negligible (no obstruction) |
| Brand | JENSPRIMA |
|---|---|
| Origin | Shanghai, China |
| Model | innoMag 300 |
| Measurement Range | 0.2–30,000 m³/h |
| Accuracy | ±0.5% of reading |
| Repeatability | ±0.1% of reading |
| Minimum Conductivity | ≥5 µS/cm |
| Electrode Materials | 316 Stainless Steel, Hastelloy C, Tantalum, Titanium |
| Lining Materials | PTFE (DN10–DN1000), Rubber (DN50–DN2000) |
| Temperature Limits | PTFE Lining –40 to +150 °C |
| Ambient Temperature | –20 to +70 °C |
| Output Signals | 4–20 mA (max. 750 Ω), Pulse, Alarm |
| Communication Protocols | MODBUS RTU (standard), HART (optional) |
| Power Supply | 85–260 VAC or 24 VDC |
| Display | Backlit LCD |
| Installation Types | Integral (S-type), Remote (L-type) |
| Pressure Loss | Negligible (no obstruction in flow path) |
| Bidirectional Flow Measurement | Yes |
| Pipe Size Range | DN10–DN2000 |